background image

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

D

D

E

B

E

A

C

E

P/N 0381957C

Merchandisers

®

Note: Changed items have been underlined.

Item

Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

9W

Fan Assembly

(1)

0047000

Fan Motor, Evaporator 

0435961

Fan Blade

embossing toward motor

B.

0411744

Standard Non-adjustable

(2)

Defrost Thermostat

C.

0137880

Optional Adjustable 

(3)

Refrigeration Thermostat

Item

Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D.

0376409

Ballast, Electronic

2 lamps

(4)

D.

0376410

Ballast, Electronic

3 lamps

(4)

D.

0376411

Ballast, Electronic

4 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

D5LR

Data Sheet Set

P/N  0381957C

NSF

®

Certified

May, 2003

Summary of Contents for IMPACT D5LR

Page 1: ... Evaporator 0435961 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0376409 Ballast Electronic 2 lamps 4 D 0376410 Ballast Electronic 3 lamps 4 D 0376411 Ballast Electronic 4 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures D5LR Data Sheet S...

Page 2: ...upport and center support 40 5 8 1032 40 5 8 1032 Distance between edges of center supports NA 44 1118 Stub up area between front skid rail and splashguard 7 178 7 178 Electrical Service Electrical Field Wiring connection point B RH End of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back of case to center of knockout 35 3 8 899 35 3 8 899 Length of electrical raceway 34 5 8 878 34...

Page 3: ...F 19 22 Btu hr ft D5LR D5LRE LIT UNLIT SHELVES Parallel 1645 1570 Conventional 1740 1670 HUSSMANN PEG SHELVES DELI ONLY Parallel 1765 1690 Conventional 1860 1790 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA Frequency Hrs 6 6 Defrost Water lb ft day 10 50 15 based on case configuration and product loading OFFTIME D5LR D5LRE Temp Term F 48 48 Failsafe ...

Page 4: ...gy Efficient Fans 120V 60Hz 1 72 2 48 With Export Fans 230V 50Hz 1 72 2 48 Maximum Over Current Protection 120V 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA Gas Defrost Heaters 208V NA NA NA NA Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Row Rail 1 02 1 54 118 170 2 Rows Canopy 1 02 1 54 118 170 2 Rows Can...

Page 5: ...ghted Shelves Note 8 Foot merchandiser has two columns of four shelves and 12 Foot merchandiser has three columns of four shelves Shelf Harness Shelf Light Circuits BL G R 5 Connector BL G R 5 Connector BL G R 5 Connector BL G R 5 Connector R R BL BL Y Y Y Y Y Y G G G G G BL BL G 4 B W G W G B Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V N...

Page 6: ... models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch...

Page 7: ...oors Fully Closed Double walled telescoping doors slide both left and right NOTE Consult Cooler Close off Kit for instructions on connecting the merchandiser to the cooler Rear View of 8 Foot Dairy Merchandiser 23 3 4 37 3 4 67 1 2 79 1 2 84 1 4 Rear Coil Grills Impact D5LR Dairy Delicatessen ...

Page 8: ...o the cooler Rear View of 12 Foot Dairy Merchandiser 23 3 4 130 1 4 37 3 4 67 1 2 79 1 2 23 3 4 D o o r s F u l l y O p e n e d D o o r s F u l l y C l o s e d Double walled telescoping doors slide both left and right D o o r s F u l l y O p e n e d R e a r C o i l G r i l l R e a r C o i l G r i l l R e a r C o i l G r i l l Impact D5LR Dairy Delicatessen ...