background image

CSB 229

1

HUGHES NETWORK SYSTEMS

* * * PES CUSTOMER SERVICE BULLETIN * * *

SUBJECT: 

PES 5000 Version 3

CSB NUMBER: 

229

CSB ISSUE DATE: 

05/11/2000

SUBMITTED BY: 

N. Tender/C. Harris/M. Furtaw

APPROVED BY:

Bayne Just

CHANGE TO BE IMPLEMENTED BY:

AUTHORIZED HUGHES REPRESENTATIVE

x

CUSTOMER

p

DOCUMENTATION AFFECTED:  

none

CATEGORY:

HARDWARE 

x

FIRMWARE 

p

SOFTWARE 

p

OTHER 

p

EFFECTIVE DATE:

5/11/2000

IMPLEMENT:

x

IMMEDIATELY

p

NEXT SERVICE CALL

p

OTHER

COMMENTS:

REMOVED MATERIAL DISPOSITION

SHIP TO

N/A

ATTENTION

N/A

COMMENTS

N/A

Summary of Contents for PES 5000

Page 1: ...der C Harris M Furtaw APPROVED BY Bayne Just CHANGE TO BE IMPLEMENTED BY AUTHORIZED HUGHES REPRESENTATIVE x CUSTOMER p DOCUMENTATION AFFECTED none CATEGORY HARDWARE x FIRMWARE p SOFTWARE p OTHER p EFFECTIVE DATE 5 11 2000 IMPLEMENT x IMMEDIATELY p NEXT SERVICE CALL p OTHER COMMENTS REMOVED MATERIAL DISPOSITION SHIP TO N A ATTENTION N A COMMENTS N A ...

Page 2: ...S 5000 version 3 in AUTO COM mode page 15 PES 5000 version 3 Replaceable Parts page 15 Multicolor STATUS LED page 16 Acronyms Abbreviations page 16 99W0383FSB fh8 14 75 12 3 Figure 1 PES 5000 version 3 also sometimes called Okemo Improved Installation Strategy HNS has received significant field feedback that installation cost and complexity should be reduced The new PES 5000 version 3 has incorpor...

Page 3: ...ration will happen in three phases 99W0424 FH8 PORT 3 VOICE PORT 4 PORT 2 PORT 1 LAN TX RX MAINTENANCE TVRO OUT IFL This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation INPUT 100 240v 3A...

Page 4: ... 0001 202 4 Type I Plenum Ku band PES 5000 75 to 479 1010809 0001 362 6 Type III Plenum Ku band PES 5000 30 to 142 1010810 0001 220 4 Type I Nonplenum Ku band PES 5000 105 to 679 1010812 0001 412 6 Type III Nonplenum Figure 3 IFL Cable Connection Phase 1 for PES 5000 Version 3 00W0064 fh8 Male F to Female N Adapter 9003769 0035 Right Angle N Adapter 9006299 0001 NOTE The appearance of your Right A...

Page 5: ...r PES 5000 Version 3 EIA 232 provides two EIA 232 ports 3000066 0002 Yes Yes EIA 232 provides two EIA 232 ports 3000066 0001 Yes No RS 422 485 provides two RS 422 485 ports 1012327 0001 Yes Yes V 35 PLC provides two V 35 ports 1013130 0001 Yes Yes Modem Backup Fail Safe PLC Provides one RS 232 port A and one metallically connected backup port B for use during space link failure 3000206 0001 Yes No...

Page 6: ...wer supply chassis At this point you may choose to prop the cover front panel assembly up to provide access Or you may choose to disconnect the ribbon cable and completely remove the cover front panel assembly 99W0430 fh8 HERE HERE A Remove screw from bottom B Apply downward pressure C Slide cover front panel assembly forward approximately two inches BOTTOM VIEW B Apply downward pressure Figure 5 ...

Page 7: ...CSB 229 7 C Slide cover front panel forward D Tilt cover front panel up 99W0432 FH8 Figure 6 Slide Cover Front Panel Assembly Forward and Tilt Up ...

Page 8: ...at the PLC in position Push the PLC down until the plastic on pins stops it When properly positioned the bottom of the PLC is approximately one inch above the motherboard HUGHES OKEMO MOTHER BOARD 99w0427 fh8 PLC CUT CORNER STANDOFF POST RIBBON CABLE to FRONT PANEL RED or non gray STRIPE Figure 7 Data Port PLC Orientation in PES 5000 Version 3 STEP 5 Replace the PES 5000 version 3 chassis cover fr...

Page 9: ...TATUS LED has a steady green glow showing that the unit is receiving a signal from the Hub that transmit is enabled and that user traffic is enabled the PC indication is BLANK BLANK followed by a blinking dot the IF indication is BLANK BLANK followed by a blinking dot the received signal strength relative to noise is maximized by refined antenna aiming and is greater than 5 dB should be 9 dB or gr...

Page 10: ...MEASURES COULD SEVERELY DAMAGE ROMs AS WELL AS CIRCUIT CARDS Remove power from the unit Remove the chassis cover front panel as described in steps 1 thru 3 on page 5 and as shown in figure 5 and 6 STEP 3 Note the location of the ROM as shown in figure 9 For the plastic leadless chip carrier PLCC integrated circuit use an appropriate extraction tool such as Methode stock number CT2012 which HNS sup...

Page 11: ...NOLOGY PLCC EXTRACTION TOOL 99w0428 fh8 HUGHES OKEMO MOTHER BOARD EXTRACTION TONGS SIDE VIEW THUMB POSITION AREA FINGER POSITION AREA U534 SLOT FOR EXTRACTION TONG PLCC ROM CUT CORNER BEVELED EDGE SLOT FOR EXTRACTION TONG U534 1028 608 E 980A Figure 9 Mother Board ROM Location and Identification ...

Page 12: ...ber DIAG Mode NN SS Pass 0001 Where NN is the test number in table 5 and SS is the sub test number in table 10 Diagnose mode progresses thru the tests in the order listed in table 5 When DIAGNOSE mode starts the status LED figure 8 on page 9 stops glowing Within approximately four minutes the diagnose mode test should complete successfully as indicated by changes in the LCD display The unit return...

Page 13: ...ed BPSK w noise 32 04 BER 128K unencoded BPSK w noise 32 08 BER 128K unencoded QPSK w noise 32 09 BER 512K encoded QPSK w o noise 32 10 BER 512K encoded QPSK w noise 32 12 BER 512K unencoded QPSK w noise 40 01 5 Volt Test 40 02 ODU PWR Test 40 03 18 RF Test 40 04 18v Rail Test 40 05 12 Volt Test 40 06 12 Volt Test 40 07 OSC TUNE Sigma Delta Test 40 08 TX Coarse VCO Voltage Test 40 09 TX Fine VCO V...

Page 14: ... process for PES 5000 version 3 The PC display 5 J lasts for approximately 3 to 4 seconds and signifies that Hub has disaster recovery software and that inroute 32 has been properly entered as F7FF Refer to CSB 219 for additional information regarding site commissioning with disaster recovery software at the Hub Install Hardware Configure Remote Parameters Set dialog ranging initial timing offset ...

Page 15: ...walkie talkies or via cellular phone After the antenna pointing voltage has been minimized below 5 0 volts the on site personnel would simultaneously press the left arrow up arrow and SELECT keys again This action will cause the remote to begin ranging at the next opportunity could be a significant delay as many remotes will be attempting to range The PC display will be 3 something dot during rang...

Page 16: ... Operation Acronyms and Abbreviations AFU Address filter unit AGC Automatic gain control BER Bit error rate BIST Built In Self Test DAC Digital to Analog converter DMAC Direct Memory Access Controller DRO Disaster Recovery EIA Electronic Industries Association EMI Electro Magnetic Interference ESD Electro Static Discharge HNS Hughes Network Systems IC Integrated Circuit IDU Indoor Unit IF Function...

Page 17: ...CSB 229 17 ...