background image

Copyright HT ITALIA 2021 

 

Release EN 1.00 - 17/05/2021 

ENGLISH 

Quick reference guide 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                         

 

Summary of Contents for THT60

Page 1: ... Copyright HT ITALIA 2021 Release EN 1 00 17 05 2021 ENGLISH Quick reference guide ...

Page 2: ...2 2 NOMENCLATURE 3 2 1 Instrument description 3 2 2 Description of function keys 6 2 2 1 Switching on the instrument 6 2 2 2 Switching off the instrument 6 2 2 3 Key 6 2 2 4 Key 7 2 2 5 T key Trigger 7 2 2 6 Key Menu OK 7 2 2 7 Key 7 3 TECHNICAL SPECIFICATIONS 8 3 1 Environment 9 3 1 1 Environmental conditions for use 9 ...

Page 3: ...en necessary Check that the battery is correctly inserted Check that the LCD display gives indications consistent with the function selected Do not direct the instrument at very high intensity radiation sources e g the sun in order to prevent damaging the IR sensor Prevent hits or strong vibrations in order to keep the instrument from damage When bringing the instrument from a cold to a hot enviro...

Page 4: ... the instrument s backside CAPTION 1 Audio Microphone USB micro SD and HDMI 2 LCD touch screen display 3 Lens associated with the IR sensor 4 Function key Image video gallery 5 Function key Laser Distance 6 Function key Menu OK 7 Function key ON OFF and Measuring Mode 8 Arrow keys 9 Trigger key T ...

Page 5: ...front side CAPTION 1 Built in white LED illuminator 2 Laser pointer 3 Laser pointer for distance measurement 4 Photo camera 5 Lens associated with the IR sensor 6 Slot for non slip strap insertion 7 Threaded hole for tripod insertion 8 Trigger key T 9 Rechargeable battery ...

Page 6: ...THT60n Quick reference guide EN 5 Fig 3 Description of the upper part of the instrument CAPTION 1 Slot for micro SD card insertion 2 Micro USB port 3 Headphone microphone input 4 HDMI video output ...

Page 7: ... Fig 4 Sequence upon switching on the instrument CAUTION The sound that accompanies the message IR Calibration is a necessary condition for the instrument s internal calibration Pressing the key allows switching on off the instrument The instrument also has an Auto Power Off function with selectable time 2 2 2 Switching off the instrument 1 Press and hold key for at least 4s to switch off the inst...

Page 8: ...display and automatically opens the section for saving the image Press the T key again to unfreeze the image on the display 2 2 6 Key Menu OK Pressing the key Menu OK allows displaying hiding the instrument s main menu The operation is always possible also by touching the display 2 2 7 Key Long pressing key allows switching on off the instrument With the instrument switched on by pressing key seve...

Page 9: ...ions according to environmental temperature reflected temperature distance relative humidity offset Advanced analyses fixed central cursor spots 3 lines 2 areas 3 Hot Cold cursors Face temp detection max 10 people at the same time distance 2m Inbuilt photo camera 5Mpxl FOV 59 Image modes IR Visible Fusion PiP Auto Fusion Laser distance measurement range 0 05m 30m accuracy 1 5mm Alarm conditions vi...

Page 10: ...0 F 158 F Allowable relative humidity 10 RH 90 RH Mechanical protection IP54 in compliance with IEC 529 Falling test 2m Shock 25G in compliance with IEC60068 2 29 Vibrations 2G in compliance with IEC60068 2 6 This instrument complies with Directive EMC 2014 35 EU This instrument satisfies the requirements of European Directive 2011 65 EU RoHS and 2012 19 EU WEEE ...

Reviews: