background image

EcoAdvance Compact

EcoAdvance Compact

 

Save this manual with the interface unit

Art.nr

. 54324 - R

ev

. A - 13.02.2020       Chang

es and misprin

ts r

ese

rv

ed

INSTALLATION & USER MANUAL

Summary of Contents for EcoAdvance Compact

Page 1: ...EcoAdvance Compact EcoAdvance Compact Save this manual with the interface unit Art nr 54324 Rev A 13 02 2020 Changes and misprints reserved INSTALLATION USER MANUAL ...

Page 2: ...Electric drill Manual processing Abbreviations DHW Domestic hot water C Temperature in degrees Celsius CH Central heating system Hz Unit for frequency 1 second pH Acidity g kg Unit for weight in grams Pa kPa Unit for pressure in Pascal mm Unit for distance in millimeter Wh kWh Unit for energy in watt hours Unit for length in inch W kW Unit for power in watt VAC Unit for alternating voltage in Volt...

Page 3: ...ns 6 Maintenance and inspection 7 Technische specificaties 8 Heat exchanger 40 plates 9 Delivery range 11 Additional items required 11 Dimensions 11 Installation 12 Room thermostat optional 16 Commisioning 17 Cover sealing 18 Errors end user 19 Errors installer 20 Guarantee 21 EC Declaration of conformity 23 ...

Page 4: ... 9 LED indication 10 Temperature sensor district heating network 11 CH control valve 12 Temperature sensor district heating network supply 13 Nipple for temperature sensor for heat meter 14 Flow sensor domestic water 15 Spool piece for heat meter 16 Differential pressure regulator 8 9 10 11 16 1 2 3 4 13 12 15 14 5 6 7 A B C D E F A Primary supply B Primary return C Domestic Hot Water D Domestic C...

Page 5: ...pply Domestic cold water District heating network supply CH return Spool piece L 110mm Electronic control unit 2 13 7 6 5 10 12 15 14 16 11 9 Connection thermostat ON OFF Service cable District heating network return Optional Domestic hot water ...

Page 6: ...reen quickly approx twice per second Interface unit in CH position there is heat demand and the CH control valve is open Interface unit without room thermostat connection cable or priority switching Flashing green slowly approx once per second Interface unit in rest or CH position OPERATION Central heating system The interface unit is fitted with a differential pressure regulator that keeps the di...

Page 7: ...a power outage during hot water tapping or in a situation where there is no heat demand from the connected room thermostat the CH control valve remains in the closed position This can result in the cooling of the CH installation Installation conditions With the installation of the interface units account must be taken of the current and applicable Buildings Regulations safety requirements for CH i...

Page 8: ...he heat supply for domestic water and CH The jacket can be cleaned with a damp cloth Under no circumstances use solvents for example cleaning spirit methylated spirits etc Note The interface unit contains electrical components 24 V direct current These components are not splashproof and must be kept dry at all times DURING ABSENCE OR HOLIDAYS Do not pull the plug out of the plug socket During long...

Page 9: ...estic hot water Central Heating supply Central Heating return Heatmeter in supply Temperature sensor heatmeter Electrical power supply Electrical power consumption per year kWh Height mm Width mm Depth mm Weight kg 3 Type on off thermostats with potential free contacts or Honeywell round on off T87G2014 thermostat with powerstealing 16 50 25 Dimensions 475 300 246 1 Performance HIU is dependent on...

Page 10: ...r temperature 55 C old domestic water temperature 10 C Domestic water flow litres minute Pressure drop tapping side kPa Pressure drop tapping side Power kW Power kW Pressure drop tapping side over interface unit Power kW Domestic water flow litres minute District heating network 65 C District heating network 70 C District heating network 80 C Power kW District heating network return temperature Di...

Page 11: ...Pressure drop district heating network kPa Power kW Domestic water flow litres minute District heating network flow litres minute Power kW 0 10 20 30 40 50 60 70 80 0 0 2 5 5 0 7 5 10 0 12 5 15 0 17 5 20 0 0 2 4 6 8 10 12 14 16 18 20 District heating network 65 C District heating network 70 C District heating network 80 C Power kW District heating network 65 C District heating network 70 C Distric...

Page 12: ... 80 40 40 300 250 75 100 75 HSF EcoAdvance Compact 15 Leveromvang Maatvoering 1x 230 V 14 22 24 30 mm Torx 25 220 195 140 80 175 75 25 40 300 250 485 495 Benodigdheden 170 65 65 60 80 80 40 40 300 250 75 100 75 HSF EcoAdvance Compact 15 Leveromvang Maatvoering 1x 230 V 14 22 24 30 mm Torx 25 220 195 140 80 175 75 25 40 300 250 485 495 170 65 65 60 80 80 40 40 300 250 75 100 75 Additional items req...

Page 13: ...rict heating supply 3 Domestic cold water 4 Domestic hot water 5 CH supply 6 CH return HSF EcoAdvance Compact 16 Installatie 1 2 1 2 1 Warmtedistributienet aanvoer 2 Warmtedistributienet retour 3 Warm tapwater 4 Koud tapwater 5 CV aanvoer 6 CV retour 6x 1 2 3 2 1 3 5 4 6 3 1 2 ...

Page 14: ...13 EcoAdvance Compact 3 4 1 2 30 mm 6x 2 1 6x ...

Page 15: ...nce Compact 5 mm 30 mm 3 24 mm 22 mm 1 14 mm Option 1 22 mm 2 Option 2 Note Spool piece must be removed and replaced by heat meter or steel spool piece Art Nº 44452 Contact your supplier 3 3 1 2 option 1 option 2 ...

Page 16: ...15 EcoAdvance Compact 1 2 2 option 1 Connection M10 x 1 BN option 2 Connection BN 30 mm 2 1 6 ...

Page 17: ...move the conductor only when a thermostat is used 2 Connect the room thermostat cable with an isolated conductor to the room thermostat sold separately CAUTION The unit can optionally be connected to a room thermostat For eligable types of thermostats see chapter Technical data 1 1 2 ...

Page 18: ... C should now be flashing green 6 Gradually open the district heating network supply D and check the unit for leaks 7 Gradually open the district heating network return E and check for leaks 8 Gradually open the CH supply F 9 Deaerate the system Start at the lowest and end at the highest radiator or bleed point 10 Gradually open the CH return G 11 Check there is heat in the system 12 Gradually ope...

Page 19: ...18 EcoAdvance Compact Cover sealing 2 torx 25 1 2 1 ...

Page 20: ...cal position If not open the valves 2 Check whether the plug of the appliance is inserted in the plug socket 230 V If not insert the plug in the plug socket 3 Check whether the radiator valves are open If not open the radiator valves 4 Set your thermostat higher than the ambient temperature 5 Problem solved If not contact your heat supplier Domestic water does not heat up 1 Check whether the valve...

Page 21: ...acket closed Open all valves on the pre fix bracket Strainer is blocked Clean all strainers Differential pressure district heating network too low Check differential pressure Supply temperature district heating network too low Check supply temperature Adaptor not in wall socket Place adaptor in wall socket Adaptor cable connector not in proper position Push the connection firmly into place Defecti...

Page 22: ...stem Electronic DHW system Model EcoAdvance Compact 5 Manufacturer HSF B V 6 Address Marketing 23 Duiven The Netherlands 7 This equipment or protective system and any acceptable variation thereto is specified in the schedule to this declaration and the documents therein referred to 8 The examination and test results are recorded in Technical file no 281A Compliance with the Essential Requirements ...

Page 23: ...22 EcoAdvance Compact ...

Page 24: ...23 EcoAdvance Compact ...

Page 25: ...24 EcoAdvance Compact ...

Page 26: ...25 EcoAdvance Compact ...

Page 27: ...26 EcoAdvance Compact ...

Page 28: ...27 EcoAdvance Compact ...

Reviews: