background image

Quick Installation Guide 

MI-600N/MI-700N/MI-800N                  AP040265      REV1.1                                                                                                                                                                           

1

  / 

2

 

 

 

1. 

Accessories 

 

Item 

Description 

AC End Cable (Female), 2m 12AWG Cable 

M8*25 screws 

DC Extension Cable, 1m 

AC Female End Cap, IP67 

*Note: All  accessories  above  are  not  included  in  the  package,  and  need  to  be  purchased 

separately.  Please  contact  our  sales  representative  for  the  price.  (M8  screws  need  to  be 

prepared by installer-self.) 

 

2. 

Installation Steps 

Please make sure the microinverter is installed under the required environment. 

(Please refer to product user manual for more details.)   

Step 1. Fix Microinverter on the Rail 

A)  Mark the approximate center of each panel on the frame. 

B)  Fix the screw on the rail. 

C)  Hang  the microinverter on  the  screw (shown  as  picture  below),  and  tighten  the screw. 

The silver cover side of the microinverter should be facing the panel. 

 

*Note:  Please  install  the  microinverter  at  least  50cm  above  the  ground/roof  for  better 

communication with Hoymiles DTU. 

Step 2. Connect AC Cables of Microinverter 

A)  Plug  the  AC  connector  of  the  first  microinverter  with  the  connector  of  the  second 

microinverter, to form a continuous AC branch circuit. 

 

*Note: The length of AC cable on microinverter is around 2.06m. If the distance between two 

microinverters is more than 2.04m, please use the AC extension cable between two inverters 

(As picture indicated below). 

 

B)  Install  the  AC  end  cap  on  the  open  AC  connector  of  the  last  microinverter  in  the  AC 

branch circuit. 

 

Step 3. Connect AC End Cable 

A)    Make the AC end cable. 

1. Take the AC port apart into 3 parts:

 

 

Reviews: