manualshive.com logo in svg
background image

Tema1.0_L19_IM_1.0_EN 

Pagina 1 di 24 

  

TKL19

  

(RTUL19)

 

 

 

 

 

 

 

Installation Manual 

Содержание Temaline TKL19

Страница 1: ...Tema1 0_L19_IM_1 0_EN Pagina 1 di 24 TKL19 RTUL19 Installation Manual ...

Страница 2: ...ly Cable 12VDC 9 1 5 3 Input Cable 1 Door Contact 10 1 5 4 Input Cable 2 Button 11 1 5 5 Output Cable Relay 1 Door Open 12 1 5 6 Output Cable Relay 2 Signal Light 15 1 6 Mounting the Device on the Wall Bracket 17 1 7 Identification Using the Service Pin 18 1 8 Identification Using the Neuron ID 19 2 1 TemaKey TKL19 RTU L19 code 1500154xx 20 2 1 1 Supplied Parts 21 2 1 2 Optional Parts 21 2 2 Recyc...

Страница 3: ... Wa al ll l S Se et t U Up p f fo or r t th he e C Ca ab bl le e T Tr ra ay ys s The cables must 1 Protrude from the wall 2 Come out at 120cm from ground see Figure 1 advised cable tray cables 120 cm Floor Figure 1 Wall Set Up for the Cable Trays Version 1 0 EN ...

Страница 4: ...e device is equipped with 2 non removable cables of 2m length Two pole twisted unpolarized cable dedicated to the LON line connection LON a 0 325 mm2 white LON b 0 325 mm2 orange Ten pole cable providing the following signals 12VDC 0 34 mm2 red GND 0 34 mm2 black INPUT 1 0 22 mm2 green white INPUT 2 0 22 mm2 gray green RELAY 2 contact C 0 22 mm2 brown RELAY 2 contact NC 0 22 mm2 white RELAY 2 cont...

Страница 5: ...nds and the signal light Figure 2 Position and dimensions of the non removable cables 4 20 cm 2 meters Shunt Box Cable 12VDC Cable LON Cable IN 1 Cable IN 2 Cable OUT 1 Cable OUT 2 RTUL19 Figure 3 Shunt Box 15 60 cm 7 20 cm 6 10 cm 2 metri 8 00 cm 2 pole LON cable 4 mm diameter 10 pole cable 8 6mm diameter ...

Страница 6: ...e Extension m based on cable capacitance AWG mm2 Ohm Km 50nF Km 100nF K m 200nF K m 500nF K m 1uF Km 12 3 3 5 7 2676 1892 1338 846 598 14 2 8 8 2153 1523 1077 681 482 16 1 3 14 1707 1207 854 540 382 18 0 9 21 1394 986 697 441 312 20 0 6 34 1096 775 548 346 245 22 0 35 52 886 626 443 280 198 24 0 2 85 693 490 346 219 155 Table 1 Length Capacitance of LONWORKS 1 Cables The FTT10A Echelon v1 2 User s...

Страница 7: ...he holes make the holes for the two bolts that will go into the wall to hold the bracket the bolts are included in the installation kit 2 Make sure that the cable tray bathces with the hole for the passage of the cables 3 Screw in the bolts Figure 4 Wall Bracket Front View and Side View Hole for Cables Hole for inserting bolt and screw to press against the anti removal anti open tamper Holes for w...

Страница 8: ...Page 8 of 24 1 1 5 5 C Ca ab bl le e C Co on nn ne ec ct ti io on ns s 1 5 1 LON Cable Figure 5 LON 1 Cable Connection 6 10 cm 2 meters LON A LON B Note connection not polarized ...

Страница 9: ...Page 9 of 24 1 5 2 Power Supply Cable 12VDC 6 10 cm 2 meters 12VDC red GND black Figure 6 Power Supply Connection ...

Страница 10: ...balanced input 1 is dedicated to door status control the balancing resistances must be positioned near the clean sensor contact White Yellow magnetic door contact NC CONTACT Figure 7 Connection for Balanced Input 1 Door Contact GND black IN1 green white ...

Страница 11: ...ed input 2 is dedicated to status control of the Open button the balancing resistances must be positioned near the clean contact of the button White Yellow button contact NO CONTACT Figure 8 Connection for Balanced Input 2 Button GND IN2 green gray ...

Страница 12: ...provided or an equivalent in parallel to the coil of the electrical locking device to increase the life of the relay inside the RTU see Figure 9 Inductive load with alternating current In this case it is mandatory to use the MOV 75VAC which is provided or an equivalante in parallel to the coil of the electrical locking device to increase the life of the relay inside the RTU see Figure 10 Life assu...

Страница 13: ...uppressor Relay 1 Figure 9 Connection for Output Relay 1 NO Door Open DC Voltage VEXT_Vac1 VEXT _Vac2 Bobina elettroserratura relè di ripetizione Mov75Vac Soppressore di transienti Rele 1 Figure 10 Connection for Output Relay 1 NO Door Open AC Voltage Green C Yellow NC Gray NO Green C Yellow NC Gray NO ...

Страница 14: ...e equipped with transient suppressors as can be seen in Figures 9 and 10 It is also suggested to use a transient suppressor on the load in order to prolong the life of the external relay VEXT_relay VEXT _relay coil for repeater relay Transient Suppressor Vext AC Mov75Vac Vext DC diodo 1N4004 Relay 1 Mov75Vac Transient Suppressor Vac Vac C NC NO coil for electrical locking device repeater Figure 11...

Страница 15: ...llel to the coil for the electrical locking device in order to increase the life of the relay inside the RTU see Figure 12 Inductive load with alternating current In this case it is mandatory to use a repeater relay and the MOV 75VAC in parallel to the coil for the electrical locking device in order to increase the life of the relay inside the RTU see Figure 13 Life assuming the relay is activated...

Страница 16: ...ad AC DC Voltage VEXT_relay VEXT _relay coil for repeater relay Transient Suppressor Vext AC Mov75Vac Vext DC diodo 1N4004 Relay 2 Mov x Vac Transient Suppressor Vac_lamp Vac_lamp C NC NO Figure 13 Connection for Output Relay 2 NO Inductive Load Repeater Relay Brown C White NC Blue NO Brown C White NC Blue NO ...

Страница 17: ... D De ev vi ic ce e o on n t th he e W Wa al ll l B Br ra ac ck ke et t Figure 14 Mounting 1 The RTUL19 is positioned atop the wall bracket protrusion 2 The back part is aligned with the wall by rotating 3 The RTUL19 is mounted onto the bracket using screws ...

Страница 18: ...ted in Figure 15 to call the service pin The signal is linked to the yellow service LED at the center which will blink throughout the operation 2 The TemaServer will send a wink command in response to the service pin which lights the yellow LED and the buzzer three times This allows you to verify that communications are operational to and from the TemaServer 3 Check to see that the service LED is ...

Страница 19: ...he kit must be applied by the installer on the appropriate identification sheet You also must indicate the location of the terminal in the appropriate box see example in Table 3 Description of Location Entrance to Offices First Floor Stairway E Description of TemaServer Panel2 Entrance First Floor Stairway E RTUL19 Table 3 Example of Compiled Identification Sheet ...

Страница 20: ...ed Green Yellow Buzzer 1 Inputs 2 balanced inputs with 4 statuses normal alarm cut short Output Relay 1 Electrical Locking Device Command Contacts C NC NO see page 12 Output Relay 2 Lamp Command Contacts C NC NO see page 15 Antenna proxy 125KHz for HID cards reading distance 0 to 40 mm MD 15W internal controller LONWORKS 2 Connection Free Topology type connected with unshielded double twisted pair...

Страница 21: ...esistances for input balancing 2 White resistances 2 Yellow resistances Fisher bolts for wall mounting 2 S4 type screws Fisher bolt for tamper 1 S4 type screws 1N4004 Diode 2 MOV 75Vrms 2 2 1 2 Optional Parts TORX TX10 Screwdriver Code 1500108AA ...

Страница 22: ... devices in vigor from 13 August 2005 Honeywell engages when requested by the customer to the collection treatment recovery and proper disposal of all devices produced All users within the European Union are hereby informed of the requirement for the proper elimination of the product as regulated by laws rules and local procedures ...

Страница 23: ...Page 23 of 24 Notes ...

Страница 24: ...Page 24 of 24 Figure 16 Temakey TKL19 ...

Отзывы: