1 Overview

These Honeywell Rack Mount CCTV power supplies will provide 12 VDC power distributed via 16 circuits for powering 
CCTV cameras and other video equipment.  Each circuit will be fuse protected at 3.0A, or PTC protected at 2.5A.  Fuses 
are accessible directly through the front panel by removing six screws.

2 Specifications

Input:  
– HPR12DC416UL & HPR13DC416CBUL - 117V, 60Hz, 1A.
– HPR12DC616UL & HPR12DC616CBUL - 117V, 60Hz, 2A.
– HPR12DC616CE & HPR12DC616CBCE - 230V, 50/60Hz, 1A.

Output:
– HPR12DC416UL & HPR12DC416CBUL - 4A @ 12VDC.
– HPR12DC616UL & HPR12DC616CBUL - 6A @ 12VDC.
– HPR12DC616CE & HPR12DC616CBCE - 6A @ 12VDC.

16 outputs.

Maximum current rating:
– HPR12DC416UL:  any output, 3A; total supply, 4A @ 12VDC.
– HPR12DC416CBUL:  any output, 2.5A; total supply, 4A @ 12VDC.
– HPR12DC616UL:  any output, 3A; total supply, 6A @ 12VDC (8A for operations below 100°F, 38°C)*.
– HPR12DC616CBUL:  any output, 2.5A; total supply, 6A @ 12VDC (8A for operations below 100°F, 38°C)*.
– HPR12DC616CE:  any output, 3A; total supply, 6A @ 12VDC (8A for operations below 100°F, 38°C)*.
– HPR12DC616CBCE:  any output, 2.5A; total supply, 6A @ 12VDC (8A for operations below 100°F, 38°C)*.

* Outputs 1 to 8 provide 3A @ 12VDC (4A operation below 100°F, 38°C) and outputs 9 to 16 provide 3A @ 

12VDC (4A operation below 100°F, 38°C).

16 power limited outputs.

Surge and transient protection.

Transformer has built-in thermal protection.

Indicator Lights:
– Input Power Indicator (1 red):  Illuminated power switch/circuit breaker.
– Output Power LEDs (16 green):  ON indicates that DC is present at the related output circuit.

Overload Protection:
– Input power switch has built-in circuit breaker.
– AC line fuse (5 x 20mm glass).
– Individual output circuits have a glass fuse (5 x 20mm) or resettable PTCs.

– NOTE: To reset a PTC that has experienced an overload or short circuit, switch power off for 5 minutes to allow 

the PTC to reset itself.

Factory installed three-conductor AC line cord with North American NEMA 5-15 plug (117V supplies) or European 
Schuko Type, CEE 7/7 plug (230V supplies).

2U rack chassis for use in standard EIA 19” rack.

Continued on next page...

Summary of Contents for HPR12DC416UL

Page 1: ... 6A 12VDC 8A for operations below 100 F 38 C HPR12DC616CBUL any output 2 5A total supply 6A 12VDC 8A for operations below 100 F 38 C HPR12DC616CE any output 3A total supply 6A 12VDC 8A for operations below 100 F 38 C HPR12DC616CBCE any output 2 5A total supply 6A 12VDC 8A for operations below 100 F 38 C Outputs 1 to 8 provide 3A 12VDC 4A operation below 100 F 38 C and outputs 9 to 16 provide 3A 12...

Page 2: ... has a blown fuse or tripped PTC the corresponding LED will not illuminate 9 Upon completion of wiring secure terminal blocks by tightening screws on flanges 4 Troubleshooting 1 If the red power indicator on the power switch is not illumated Verify that power is present at receptacle Verify that the unit is plugged into the power receptacle Verify that the power switch is in the ON RESET position ...

Page 3: ...set to ON Set power switch on back of unit to the OFF position and unplug power cord from receptacle Remove field wiring to affected circuits and check for shorts and overloads Replace field wiring after resolving any shorts and or overloads Replace blown fuse on HPR12DC616UL HPR12DC416UL HPR12DC616CE as follows Remove the six screws holding front panel and remove front panel It is not necessary t...

Page 4: ...4 HPR12DC416UL CB HPR12DC616UL CB Installation Document P N 52995 A 5 31 06 Figure 1 Power Supply with Front Panel Removed 52995bd1 wmf Continued on next page ...

Page 5: ...ER TO PRODUCT INSTALLATION DOCUMENT PN 52___ INPUT 117VAC 60Hz 6A OUTPUT 24 VAC 25A OR 28VAC 21 4A COMMERCIAL CLOSED CIRCUIT TELEVISION EQUIPMENT XXXX 8 N P 7 N P 6 N P 5 N P 4 N P 3 N P 2 N P 1 N P 16 N P 15 N P 14 N P 13 N P 12 N P 11 N P 10 N P 9 N P VERIFY OUTPUT VOLTAGE BEFORE CONNECTING DEVICES Circuit 1 Common Common Common Circuit 2 Circuit 3 Power ON OFF Switch Circuit Breaker Field Wirin...

Page 6: ...stallation Document P N 52995 A 5 31 06 For additional information Visit our website at http www honeywellpower com Contact Technical Support at 1 877 HPP POWR E mail us at hpp_techserv honeywell com Figure 3 Dimensions hprdimensions wmf ...

Reviews: