background image

1

HOLDPEAK 

4201

 

INSTRUCTION

 

MANUAL

 

We

 

thank

 

you

 

very

 

much

 

for

 

your

 

purchasing

 

our

 

POCKET

 

PERSONAL

 

DIGITAL

 

MULTIMETER.

 

This

 

model

 

is

 

a

 

most

 

reliable,

 

high-precision

 

instrument,

 

designed

 

by

 

our

 

excellent

 

technology.

Before

 

you

 

use

 

your

 

new

 

instrument,please

 

read

 

this

 

Operators

 

Manual

 

completely

 

and

 

familiarize

 

yourself

 

Thoroughly

 

with

 

all

 

functions

 

and

 

connections.With

 

proper

 

use

 

and

 

care

 

your

 

Digital

 

Multimeter

 

will

 

give

 

you

 

years

 

of

 

satisfactory

 

service.

SAFETY RULES

*Alwavs check to make sure that the function switch is set
to the proper position.
*When making measurements,CAUTION as dangerous
voltages may be present in normally safe areas.
*Always disconnect the circuit under test prior to attaching
test leads,as voltages may be present in capacitors even
when the main power is disconnected.
*To avoid electrical shock,use CAUTION when working
above 60V DC or25V AC rms.Such voltages pose a shock
hazard.
*Make sure all power(AC or DC)is disconnected
(OFF)when making resistance(OHMS)measurements.
*Never make measurements with the battery cover of
battery case OFF.
*Never fail to keep the maximum tolerable input.
*The POCKET PERSONAL DMM is designed for low
voltage applications.The measurement should be limited to
the circuit under 450V(AC/DC)
*Never use this meter if it is WET,DAMP or has
condensation on it or the probes.
*When making measurements MAKE SURE your hands
NEVER touch anything except the plastic part of the
probes.

SPECIFICATIONS

Measuring method.............................Dual integration mode
Display...............3-

¾

digit LCD max reading of approx4000

Range................................................................Auto ranging
Polarity.........................Automatic no indication for positive
polarity,minus(-)sign for negative polarity
Overrange

indication........."OL"mark

indication(Except

AC/DC 450V ranges)
Sampling.............................2 times/s low battery indication
"

"mark is displayed when the battery voltage drops

below operating voltage
Auto power off..................The meter is powered off 15
minute later after the last operation was made to bring back
display,please turn the function switch to the off.
Operational temperature...................0~40

℃,

80%RH(max.)

Storage temperature........................20~60

,70%RH(max.)

Power consumption............................................6mW(TYP)
Size..............................................54(W)*108(H)*12(D)mm
Weight.................Approx 110g(included batteries and case)
Accessores...............Batteries,LR-44(1.55V)......................2

Hard cover case.................................1
Instruction manual.............................1

MEASUREMENT

 

RANGES

Note/Accuracy

 

specified

 

for

 

temperature

 

range

 

of

 

18

°C

~28

 

(80%RH

 

max)

DESCRIPTION OF PANEL

Function switch........
Switch for changing the measurement function.
(Ω/

)for resistance,continuity check.

(VOLT)for voltage measurement
(OFF)for power OFF
Display........
3-

¾

digit liquid crystal display from to approx.4000 count

with decimal point,annunciators display.
Test leads......
Red test lead for plus (+) poiarity.Black test lead for minus
(-) polarity.

DCV

Range

Resolution

Accuracy

input

resistance

Max.Input

400mV

100uV

±1.3%rdg±2dgt

>100MΩ

Max,input:

250V DC

or250V AC rms

on 400mV

range;450V DC

or 450VAC rms

on all other

ranges.

4V

1mV

10MΩ

40V

10mV

400V

100mV

450V

1V

ACV

(50/60HZ)

Range

Resolution

Accuracy

input

resistance

4V

1mV

±2.3%rdg±5dgt

10MΩ

40V

10mv

400V

100mV

450V

1V

OHM

Range

Resolution

Accuracy

Test current Input protection

400Ω

100mΩ

±2.0%rdg±5dgt

<0.7mA

250V rms

4KΩ

±2.0%rdg±2dgt

<0.13mA

40KΩ

10Ω

<13A

400KΩ

100Ω

<1.3A

4MΩ

1KΩ

±6.0%rdg±2dgt

<0.13A

40MΩ

10KΩ

±10%rdg±5dgt

Continuity

Check

Range

Resolution

Continuity beeper Test current Input protection

400Ω

100mΩ

<approx,50Ω

<0.7mA

250V rms

Reviews: