background image

KX15DQ

15m Digital PIR Detector

 

0845 6434 999 (UK). +44(0)1709 535 225

  

 [email protected]   

 

www.pyronix.com   

Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK  

 

       

RINS1039-8

E N G L I S H

(Diagram references)

Technical Specification

Warranty

Product Warning Information

This product is sold subject to our standard warranty conditions and is warranted 

against defects in workmanship for a period of five years.
For further warranty information visit: 

www.pyronix.com/warranty

For electrical products sold within the European Community. At the end of the 

electrical products life, it should not be disposed of with household waste. Please 

recycle where facilities exist. Check with your Local Authority or retailer for recycling 

advice in your country.  The declaration of conformity may be consulted at 

www.pyronix.com/product-compliance.php

This product is approved for use in the Residential, 

Commercial and Light Industrial Environments.

EOL

The KX15DD Printed Circuit Board

® 

D

C3

AUTO  HI

LOW AUTO

AUTO  HI

LOW AUTO

AUTO  HI

LOW AUTO

==

=

=

LOW

Model:  

KX15DQ

Colour:  

White

LED Colour:  

Blue

Casing:  

3mm ABS, 0.4mm HDPE in lens area

Detection Method:  

Digital Quad Signal Processing

PIR Sensitivity:  

Auto (Default), High, Low

Temperature Compensation:  

Digital

Detection Range:  

15m  (13m by EN50131-2-2 & INCERT criteria)

Detection Speed:  

0.3 - 3.0 m/s

Operating Voltage:  

9 - 16V DC 13.8V DC typical

Current Consumption:  

13mA @ 12V (Min),  16mA @12V (Max)

Relay Output:  

50mA 60V DC, 42 VAC (RMS)

Contact Resistance:  

< 10 ohms

Mounting Height:  

1.8 - 2.4m

Tamper Switch:  

12V  50mA

Storage Temperature:  

-40

o

C to  80

o

C

Certified Operating Temperature:  

-10

o

C to  40

o

C

Nominal Working Temperature:  

-30

o

C to  70

o

C

Accessories:  

Wall and Ceiling brackets

Emissions:  

EN55022 Class B

Immunity:  

EN50130-4

HIGH 

PCB

DEFAULT

PREDEFINITO

HIGH / 

LOW

 

B

START

f) Back 

Tamper

C

D

F

G

E

1

A

B

2

C

D

3

A

LED ON

LED OFF

1

A

B

C

Printed Circuit Board (PCB)
LED light pipe / diffuser
Lens

D

E

F

G

Lens holder
PCB screw
Captive nut

Casing screw

2
33
34

PCB configuration (Including PIR sensitivity)

Mounting Options

The 15m Volumetric Lens.                        Dimensions and Weight

EOL Resistor Headers: 

The KX15DQ has 2 sets of header pins (as shown). These 

headers are used to select the End of Line resistance for EOL wiring applications.  

NOTE: If EOL wiring is not used, leave the headers OFF. 

Remote LED Enable: 

This is used when the LED is disabled via the  LED ON/OFF 

link. To enable this feature the LED terminal needs to be connected to an output 

on the control panel. When the system is in walk test mode the output should 

be at 0v. For Pyronix panels the output would usually be programmed as 

‘Remote LED enable’.

Powering Up: 

When the detector is first powered up, it will run through a self-test 

routine (indicated by the flashing blue LED). Once the LED goes out the detector 

is ready to use.

35

36

37

38

39

A

B

C

D

E

N/C

 - Normally Closed Wiring 

(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)

PCX

 DEOL Wiring 

(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)

EURO

 DEOL Wiring 

(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)

Generic Control Panel (shows resistor locations)
2x Double End of Line Detectors to One Input 

(SEE CONTROL PANEL INSTRUCTIONS)

+

+

+

+

+

+

+

+

+

+

+

+

 P

IR

TAMPER

TAMPER

5K6, 4K7, 2K2, 1K

ALARM

6K8, 5K6, 

4K7, 2K2, 1K

A

B

B

C

3

AUTO

EN50131-2-2:2008              

EN50131-1:2006+A1:2009        

PD6662:2010

Security Grade (SG) 2
Environmental Class (EC) II

Summary of Contents for Pyronix KX15DQ

Page 1: ...fiedOperatingTemperature 10o Cto 40o C NominalWorkingTemperature 30o Cto 70o C Accessories WallandCeilingbrackets Emissions EN55022ClassB Immunity EN50130 4 HIGH PCB DEFAULT PREDEFINITO HIGH LOW B START f Back Tamper C D F G E 1 A B 2 C D 3 A LED ON LED OFF 1 A B C Printed Circuit Board PCB LED light pipe diffuser Lens D E F G Lens holder PCB screw Captive nut Casing screw 2 3 3 3 4 PCB configurat...

Page 2: ...OL INPUT 1 12V 0V 12V 0V ALARM TAMPER PCX EURO PCX ALARM CONTROL PANEL 6K8 5K6 4K7 2K2 1K 5K6 4K7 2K2 1K TAMPER ALARM ALARM TAMPER Control Panel Output 0v in walk test LED A A T T EOL INPUT 1 12V 0V EURO 4K7 PCX 1K PCX EURO LINK ALARM CONTROL PANEL 6K8 5K6 4K7 2K2 1K 5K6 4K7 2K2 1K TAMPER ALARM ALARM TAMPER Control Panel Output 0v in walk test LED 12V 0V ALARM ALARM TAMPER END ALARM CONTROL PANEL ...

Page 3: ...ELD RAADPLEEG DE INSTRUCTIES VOOR HET BEDIENINGSPANEEL Algemeen bedieningspaneel toont de weerstandslocaties 2x dubbele EOL detectors voor één input RAADPLEEG DE INSTRUCTIES VOOR HET BEDIENINGSPANEEL EN50131 2 2 2008 EN50131 1 2006 A1 2009 PD6662 2010 Classe de sécurité SG 2 Classe environnementale CE II F R A N Ç A I S Références des schémas Spécifications techniques Garantie Informations d avert...

Page 4: ...da pelo LED azul intermitente Quando o LED apagar o detetor está pronto para ser utilizado 3 5 3 6 3 7 3 8 3 9 A B C D E N F Cablagem normalmente fechada APENAS EXEMPLO VER AS INSTRUÇÕES DO PAINEL DE CONTROLO Cablagem de fim de linha duplo DEOL PCX APENAS EXEMPLO VER AS INSTRUÇÕES DO PAINEL DE CONTROLO Cablagem de fim de linha duplo DEOL EURO APENAS EXEMPLO VER AS INSTRUÇÕES DO PAINEL DE CONTROLO ...

Reviews: