INSTRUCTION MANUAL – HYDRAULIC HAND PUMPS:  

Model Series: HP110, HP227-257, HP211-252D, HPX1500-2800

 

Hi-Force Limited – Prospect Way – Daventry – Northants NN11 8PL – United Kingdom 
Tel: +44(0) 1327 301000:  Fax: +44(0) 1327 706555: Website: www.hi-force.com  

 

NOTE:

 Spare parts sheets for these products are 

available from the Hi-Force website at: 

www.hi-force.com

 

or from your local regional Hi-Force Sales office 
or authorized local Hi-Force distributor. 
 

1.0

 

Inspection of the product upon receipt:

 

On receipt of the product, visually inspect the 
item for any evidence of shipping damage. 
Please note shipping damage is not covered 
by warranty. If shipping damage is found notify 
the carrier immediately and refrain from putting 
the product into service. The carrier is 
responsible for repair and replacement costs 
resulting from damage in transit shipment. 

2.0

 

Safety Precautions: 

 

Read  and  follow  all  the  instructions and  safety 
warnings carefully prior to use of the equipment. 
Failure  to  do  so  could  result  in  equipment 
damage or failure of the equipment or personal 
injury.  Hi-Force  will  not  be  held  responsible  for 
any  damage  to  the  equipment  or  personal 
injury resulting  from  unsafe  use  of  the  product, 
lack of maintenance or incorrect operation. If in 
doubt  on  the  correct  usage  of  any  Hi-Force 
equipment, contact your nearest Hi-Force office 
or  distributor.  If  the  operator  has  not  been 

trained  on  high  pressure  hydraulic  equipment 
and its safe use consult your local Hi-Force sales 
office  who  can  offer  you  training  courses  for 
operators. 

 

All operators should ensure that all necessary 
personal protective equipment as specified by 
their employer is worn when operating any 
hydraulic equipment. Safety shoes, safety 
glasses/ visor and protective gloves should be 
worn at all

 

times. All relevant risk assessments 

should be completed prior to use of the 
equipment 

Warning: 

All ancillary equipment to be 

used with these ranges of hydraulic 

manual pumps 

MUST

 be rated for use at the 

same operating pressure as the pump model to 
be used:- 
HP110 – 700bar (10,000psi) 
HP227 – HP257 – 700 bar (10,000psi) 
HP211, HP212, HP232, HP252–700 bar (10,000psi) 
HP232D, HP252D – 700 bar (10,000 psi) 
HP245 – HP245D – 700 bar (10,000 psi) 
HPX1500 – 1500 bar (21,755 psi) 
HPX2800 – 2800 bar (40,610 psi) 
 

Sufficient time should be allocated to 
planning your hydraulic system. Make 

sure that all the components are fit for the 
intended use.  
 

 Ensure there is sufficient oil capacity in 
the pump reservoir to fully operate the 

system to be used. 
 

DO NOT

 exceed the rated pressure of the 

pump or the rated capacity of the 

system to be used. Under no circumstances 
ever tamper with the internal safety relief valve 
of the pump. 
 

Keep hydraulic pumps away from flames 
and direct heat.  

Hydraulic  pumps  must  only  be  serviced  by  a 
qualified technician.  
To  protect  your  warranty,  only  use  Hi-Force’s 
hydraulic oil. 
Immediately  replace  any  worn  or  damaged 
parts using genuine Hi-Force parts only.  
The system operating pressure must not exceed 
the pressure rating of the lowest component in 
the  system.  Where  possible,  use  a  pressure 
gauge to monitor the system.  
Avoid  damaging  hydraulic  hose.  Always  route 
hoses  to  ensure  that  they  are  free  from  sharp 
bends and kinks. Using a bent or kinked hose will 
cause severe back-pressure and can also lead 
to the failure of the hose.  
 

Never

  lift  or  carry  any  hydraulic 

components  by  the  hose  or  hoses 

connected to them. 

Do not

 handle a pressurized hydraulic 

hose. Oil escaping under pressure from a 

ruptured hose can penetrate the skin and lead 
to a serious medical emergency and in certain 
cases death. Should this incident happen 
medical attention must be sought immediately. 