background image

 

T H E R M O F I L M   A U S T R A L I A   P T Y   L T D           w w w . h e a t s t r i p . c o m . a u  

2 7   R o s a l i e   S t r e e t ,   S p r i n g v a l e   V I C   3 1 7 1   A u s t r a l i a    
P :   6 1 + 3   9 5 6 2   3 4 5 5     F :   6 1   + 3   9 5 4 8   3 9 7 9     h e a t s t r i p @ t h e r m o f i l m . c o m . a u  

 

 

 
 

E L E C T R I C   R A D I A N T   O U T D O O R   /   I N D O O R   H E A T E R  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
I N S T A L L A T I O N ,   O P E R A T I O N   &   M A I N T E N A N C E   M A N U A L  
 

IMPORTANT INSTRUCTIONS 
SAVE THESE INSTRUCTIONS 

Prior to installing and operating the heater, read these instructions carefully and 
retain for future reference. 

 

INTRODUCTION 

 
The HEATSTRIP product range offers an elegant solution for both indoor and outdoor 
heating requirements. 
 
Casing options include powder coat finish and stainless steel. (Stainless steel model is 
recommended in coastal areas.)  
 
All HEATSTRIP products have an IPX5 rating for protection against water ingress and are 
suitable for undercover outdoor installation. 

 
M O D E L   C O D E S  
 

model 

watts  rating  branch 

circuit 

dimensions 

weight 

THH1500US / THH1500US-SS 

1500 

120V 

15A 

33 ½ x 7 ¾ x 1 ¾  12.0lbs 

THH2400US / THH2400US-SS 

2400 

240V 

15A 

52 ½ x 7 ¾ x 1 ¾  17.0lbs 

THH3200US / THH3200US-SS 

3200 

240V 

20A 

69 ¾ x 7 ¾ x 1 ¾  22.0lbs 

 

MODEL CODE NOTES 

 
SS 

Denotes stainless steel casing. 

 

 

UL / CSA APPROVAL E321448 
 

Summary of Contents for THH1500VS

Page 1: ...nd retain for future reference INTRODUCTION The HEATSTRIP product range offers an elegant solution for both indoor and outdoor heating requirements Casing options include powder coat finish and stainless steel Stainless steel model is recommended in coastal areas All HEATSTRIP products have an IPX5 rating for protection against water ingress and are suitable for undercover outdoor installation MOD...

Page 2: ... heater is required to be fitted with an ON OFF isolation switch and can also be controlled via thermostat timer or dimmer type control A wall switch should be installed on fixed wire installations The heater should also be connected via an R C D Residual Current Device Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or...

Page 3: ...acent walls a minimum 4 100mm clearance from back of heater to any mounting surface and a minimum clearance of 39 1000mm or more from bottom of heater to any surface below The heater should have a minimum clearance of 12 300mm from the ceiling to the back of the heater when wall mounted at an angle The heater must not be mounted immediately below or in front of a socket outlet If installed in wet ...

Page 4: ...op and bottom brackets using the screws provided 4 Use the self tapping screws to lock the top and bottom brackets in either horizontal or angle mounting position INSTALLATION WIRING CONNECTION For supply connections use wires suitable for at least 90 C or equivalent Connect the earth active and neutral wires to the connector block in the junction box mounted on the heater Make sure the earth cabl...

Page 5: ...s t r i p c o m a u 2 7 R o s a l i e S t r e e t S p r i n g v a l e V I C 3 1 7 1 A u s t r a l i a P 6 1 3 9 5 6 2 3 4 5 5 F 6 1 3 9 5 4 8 3 9 7 9 h e a t s t r i p t h e r m o f i l m c o m a u 5 Options for connecting inch flexible conduit Wiring Assembly Earth ...

Page 6: ...cular salt in the air can cause rusting and staining of metal including stainless steel Even in city locations pollution in the air can contaminate surfaces and will affect the ability of the coatings and materials of the HEATSTRIP to resist rust and stains This applies to both the painted and stainless steel models As the HEATSTRIP has a protection rating for water ingress of IPX5 it can be safel...

Page 7: ...ctory or any other location authorised in writing by Thermofilm is the sole responsibility of the customer o Thermofilm does not participate in any site related costs or labour expenses incidental to replacement of parts repairing removing installing servicing transportation or handling of parts or complete products and assumes no liability on parts repaired or replaced without written authorisati...

Page 8: ...e transport company of the condition and have them noted on the freight documents If damage is discovered after unpacking demand immediate inspection by the transportation company and insist that a record of the damage is made on the freight documentation The Customer warrants to use the product in accordance with o Any instructions provided to it by Thermofilm from time to time o All government a...