background image

ma_hsi150_gsm110_125_160_varia_k2_varia_200108

Hauff-Technik GmbH & Co. KG

Robert-Bosch-Straße 9
89568 Hermaringen, GERMANY

Tel. +49 7322 1333-0
Fax +49 7322 1333-999

offi ce

@hauff-technik.de

www.hauff-technik.de

Art. Nr

.:

50

90

03

20

93

 

Rev

.: 01/2020-01-08

Vor Beginn der Montage Anweisung lesen und gut aufbewahren!

Read the instructions prior to installation and keep them in a safe place!

Lire les instructions avant le montage et bien les conserver!

Voor het begin van de montage de handleiding lezen en goed bewaren!

Przed rozpoczęciem montażu przeczytaj instrukcję obsługi i przechowuj ją w odpowiednim miejscu!

www.hauff-technik.de

Immer. Sicher. Dicht.

Immer. Sicher. Dicht.

2

Art. Nr.: 5090032093 

Rev.: 01/2020-01-08

HSI150 1x1 GSM110/125/160 Varia 

(HSI150 1x1 K2 Varia)

Montageanleitung - 

HSI150 1x1 GSM110/125/160 Varia (HSI150 

1x1 K2 Varia). 

Kabeldurchführung mit variabler Längeneinstel-

lung. 

DE

Installation instructions - 

HSI150 1x1 GSM110/125/160 Varia 

(HSI150 1x1 K2 Varia). 

Cable entry with adjustable length setting.

EN

Notice de montage - 

HSI150 1x1 GSM110/125/160 Varia (HSI150 

1x1 K2 Varia). 

Passe-câbles à réglage en longueur variable.

FR

Montagehandleiding - 

HSI150 1x1 GSM110/125/160 Varia (HSI150 

1x1 K2 Varia).

 Kabeldoorgang met variabele lengte-instelling.

NL

Instrukcja montażu - 

HSI150 1x1 GSM110/125/160 Varia (HSI150 

1x1 K2 Varia). 

Przepust kablowy ze zmiennym ustawieniem 

długości.

PL

+49 7322 

13

3

3

-0

HSI150 1x1 GSM160 Varia

+49 7322 

13

3

3

-0

HSI150 1x1 K2 Varia

2

1

2

3

4

5

8

6

7

6

6

5

1

+49 

7322

 1

33

3

-0

1

2

3

4

5

13
12

11

9

8

10

8

7

6

6

3

1

4

1

2

3

5

1

2

7

1

8

4

2

3

1

Summary of Contents for HSI150 1x1 GSM110 Varia

Page 1: ...032093 Rev 01 2020 01 08 HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Montageanleitung HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Kabeldurchführung mit variabler Längeneinstel lung DE Installation instructions HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Cable entry with adjustable length setting EN Notice de montage HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Passe ...

Page 2: ...032093 Rev 01 2020 01 08 HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Montageanleitung HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Kabeldurchführung mit variabler Längeneinstel lung DE Installation instructions HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Cable entry with adjustable length setting EN Notice de montage HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Passe ...

Page 3: ...1 2020 01 08 Art Nr 5090032093 Rev 01 2020 01 08 33 4 3 EN Notizen Notes Remarques Opmerkingen Notatki HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia 13 14 9 1 11 1 1 2 15 1 2 16 2 1 17 18 10 2 1 12 1 2 3 ...

Page 4: ...1 2020 01 08 Art Nr 5090032093 Rev 01 2020 01 08 33 4 3 EN Notizen Notes Remarques Opmerkingen Notatki HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia 13 14 9 1 11 1 1 2 15 1 2 16 2 1 17 18 10 2 1 12 1 2 3 ...

Page 5: ...ontage kann zu Sachschäden führen Bei den Betonierarbeiten sind die jeweiligen länderspezifischen Normen und Regelwerke zu beachten Dies gilt insbesondere bei wasserundurchläs sigen Betonbauteilen nach EN206 1 Elementbauweise oder Arbeiten mit selbstverdichtendem Beton Bei Betonwänden in Doppelelement Bauweise ist darauf zu achten dass die Position aller Dreistegdichtungen vollflächig und innerhalb...

Page 6: ...ormwork spacers ties between packages The spacer HSI AH 40 must be used in the case of block assembly of pipe connections Øa 160 mm as well as for optimised compaction of the concrete and later the compaction of the cable duct trench enlargement of dimension between centre lines from 210 mm to 250 mm Do not open the closing cover of the cable entry until immediately before laying the cables Note i...

Page 7: ...re entreprise Le monteur doit porter l équipement de protection adéquat Monter uniquement des pièces en parfait état Il convient d observer les avertissements conseils et re commandations suivants avant de procéder au montage du passe câbles HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 FR K2 Varia AVERTISSEMENT Un montage non conforme peut entraîner un risque de blessure Un montage non conforme peut...

Page 8: ...0 systeemdeksels en HRD150 160 drukdichtingen Let op de correcte inbouwrichting De HSI150 1x1 K2 Varia is een in lengte verstelbare kabeldoorvoer om vlak in NL betonwanden te storten Eventuele lengteaanpassingen ter plaatse van 200 575 mm met 4 basistypen voor alle soorten stortbeton en geschikt voor elementen bouw Tweezijdig aansluitbaar zijn HSI150systeemdeksels en HRD drukdichtingen resp het KE...

Page 9: ...w budynkach w których materiały budowlane odpowiadają bieżącemu stanowi techniki Nie ponosimy odpowiedzialności za jakiekolwiek inne wykorzystanie lub zastosowanie wykraczające poza ten zakres chyba że po konsultacji z nami zostanie to wyraźnie potwierdzone na piśmie Warunki gwarancji zostały zawarte w naszych ogólnych warunkach handlowych Nie ponosimy odpowiedzialności wynikającej z odstępstw od ...

Page 10: ...zymana przesyłka jest kompletna oraz czy nie została uszkodzona w trakcie transportu W przypadku stwierdzenia widocznych uszkodzeń transportowych Nie przyjmować przesyłki lub przyjąć ją warunkowo Opisać uszkodzenia transportowe na dokumentach logistycznych lub na dokumentacji dostawy spedytora Należy natychmiast reklamować wszelkie zaobserwowane uszkodzenia i braki Roszczenia wynikające z powstani...

Page 11: ...chreibung Beschreibung Kabeldurchführung HSI150 1x1 GSM110 125 160 Varia siehe Abb 1 5 Montage vorbereiten 1 Kabeldurchführung auf eine Ebene stellen und an hand der Skala auf die gewünschte Länge bzw auf den gewünschten Schalungsabstand Wandstärke einstellen siehe Abb 3 1 Impressum 11 2 Symbolerklärung 11 3 Benötigtes Werkzeug und Hilfsmittel 11 4 Beschreibung 11 5 Montage vorbereiten 11 6 Montag...

Page 12: ...0 Zubehör zu verwenden Dadurch wird bei geplanten Kabelschutzrohrtrassen und Rohren mit einem Außendurchmesser von 160 mm Anschluss über KES M150 R160 bzw bei HSI150 1x1 K2 Varia HSI150 M168 WR KES M150 D oder HSI150 D160 GSM eine höhere Verdichtungsqualität des Schutzrohrgrabens und die saubere Einhaltung der Schutzrohr mindestabstände 50 mm erreicht Sofern keine Abstandhalter HSI AH40 einge setz...

Page 13: ...e 2 Einschlagdeckel HSI150 GSM160 Varia Anschließend Schalung schließen siehe Abb 10 Zwischen Dreistegdichtungen und Armie rungseisen ist ein Abstand von mind 5 cm zu berücksichtigen Der Rödeldraht darf dabei nicht an den Dreistegdichtungen befestigt werden 2 Die Einstecktiefe siehe Tabelle 3 am Kabelschutz rohr markieren siehe Abb 15 Die Gummisteckmuffe innen mit Gleitmittel GMT einstreichen und ...

Page 14: ...5 365 470 mm 250 mm 210 mm HSI150 1x1 GSM125 Varia 470 575 Ø125 470 575 mm 250 mm 210 mm HSI150 1x1 GSM160 Varia 260 320 Ø160 260 320 mm 250 mm HSI150 1x1 GSM160 Varia 320 425 Ø160 320 425 mm 250 mm HSI150 1x1 GSM160 Varia 425 530 Ø160 425 530 mm 250 mm HSI150 1x1 GSM160 Varia 530 635 Ø160 530 635 mm 250 mm Typ Varia Geeignet für Wandstärke HSI150 K2 Varia 200 260 200 260 mm HSI150 K2 Varia 260 36...

Page 15: ...25 160 Varia see Fig 1 5 Preparing for installation 1 Place the cable entry on the level and set to the desired length or the desired shuttering space wall thickness using the scale see Fig 3 1 Publishing notes 15 2 Explanation of symbols 15 3 Tools and aids required 15 4 Description 15 5 Preparing for installation 15 6 Installation 16 7 Preparing for installation of the pipe connection work stage...

Page 16: ...40 are not used for example Legend for Fig 7 1 HSI AH40 for pipe connection Da 160 mm Legend for Fig 8 1 Block assembly with spacer and connection of a pipe Øa 160 mm e g via HSI150 GSM160 Varia 2 Centre distance 250 mm 3 Water barrier spacing dimensions 65 mm 4 Cable duct spacing dimensions 90 mm 6 Installation 1 Nail the wall insert to the wood shuttering using the nail holes provided in the clo...

Page 17: ...ed Avoid overloading the filled pipeline trench during construction e g driving over it with heavy construction machinery or vehicles Legend for Fig 15 1 Insertion depth 2 Outside of building Sawn off sharp pipe ends must be chamfered all round with a sanding or chamfering tool at an angle of approx 15 20 to a length of 5 10 mm and deburred before insertion into the plug in socket see Fig 16 Legend...

Page 18: ...HSI150 1x1 GSM125 Varia 260 365 Ø125 260 365 mm 250 mm 210 mm HSI150 1x1 GSM125 Varia 365 470 Ø125 365 470 mm 250 mm 210 mm HSI150 1x1 GSM125 Varia 470 575 Ø125 470 575 mm 250 mm 210 mm HSI150 1x1 GSM160 Varia 260 320 Ø160 260 320 mm 250 mm HSI150 1x1 GSM160 Varia 320 425 Ø160 320 425 mm 250 mm HSI150 1x1 GSM160 Varia 425 530 Ø160 425 530 mm 250 mm HSI150 1x1 GSM160 Varia 530 635 Ø160 530 635 mm 2...

Page 19: ...âble sur un niveau et à l aide des graduations régler à la longueur souhaitée ou selon l écart de coffrage épaisseur de mur souhaité voir fig 3 1 Mentions légales 19 2 Signification des symboles 19 3 Outils et instruments nécessaires 19 4 Description 19 5 Préparer le montage 19 6 Montage 20 7 Préparation de montage du raccordement de tube étapes de travail 1 et 2 uniquement pour HSI150 GSM110 125 ...

Page 20: ...révu un tracé de gaines passe câbles et tuyaux d un diamètre interne de 160 mm raccordement par le système KES M150 R160 ou pour le passe câbles HSI150 1x1 K2 Varia HSI150 M168 WR KES M150 D ou HSI150 D160 GSM une meilleure qualité de compac tage de la tranchée de la gaine de protection et un respect précis des écarts minimaux entre les gaines de protection 50 mm Si aucun écarteur HSI AH40 n est u...

Page 21: ...ferrail le Les liens à boucles en métal ne doivent tou tefois pas être fixés aux joints à trois nervures 2 Marquer la profondeur d enfichage voir tableau 3 sur la gaine passe câble voir fig 15 Enduire l intérieur du manchon emboîtable en caoutchouc avec du lubrifiant GMT et pousser la gaine passe câble jusqu au marquage dans le manchon emboîtable En raison des coefficients de dilatation relativement...

Page 22: ...1 GSM110 Varia 470 575 Ø110 470 575 mm 250 mm 210 mm HSI150 1x1 GSM125 Varia 200 260 Ø125 200 260 mm 250 mm 210 mm HSI150 1x1 GSM125 Varia 260 365 Ø125 260 365 mm 250 mm 210 mm HSI150 1x1 GSM125 Varia 365 470 Ø125 365 470 mm 250 mm 210 mm HSI150 1x1 GSM125 Varia 470 575 Ø125 470 575 mm 250 mm 210 mm HSI150 1x1 GSM160 Varia 260 320 Ø160 260 320 mm 250 mm HSI150 1x1 GSM160 Varia 320 425 Ø160 320 425...

Page 23: ...SI150 1x1 GSM110 125 160 Varia zie afb 1 5 Montage voorbereiden 1 Kabeldoorvoer op een vlakke ondergrond plaatsen en met behulp van de schaalverdeling op de gewenste lengte of bekistingsafstand wanddikte instellen zie afb 3 1 Impressum 23 2 Toelichting op de symbolen 23 3 Benodigd gereedschap en hulpmiddelen 23 4 Omschrijving 23 5 Montage voorbereiden 23 6 Montage 24 7 Voorbereiding voor montage v...

Page 24: ...e minimale afstand van de mantelbuizen 50 mm exact aangehouden Met de afstandhouder HSI AH40 de dichtpakkingen HSI150 via het frame insteeksysteem tot pakketten Als er geen afstandhouders HSI AH40 worden gebruikt bijv uit plaatsgebrek dan is extra zorgvuldigheid vereist bij het beton storten en later bij het verdichten van de mantelbuissleu ven om schade door een slechte betonverdich ting maar ook...

Page 25: ... 2 De insteekdiepte zie tabel 3 op de mantelbuis mar keren zie afb 15 De rubber insteekmof binnen insmeren met glijmid del GMT en de mantelbuis tot aan de markering in de rubber insteekmof schuiven Vanwege de relatief hoge uitzettingscoëf ficiënt van thermoplastische kunststoffen moet ook rekening worden gehouden met de uitzetting in de lengterichting van buizen bij hoge temperaturen De sleuf boven...

Page 26: ... 260 mm 250 mm 210 mm HSI150 1x1 GSM125 Varia 260 365 Ø125 260 365 mm 250 mm 210 mm HSI150 1x1 GSM125 Varia 365 470 Ø125 365 470 mm 250 mm 210 mm HSI150 1x1 GSM125 Varia 470 575 Ø125 470 575 mm 250 mm 210 mm HSI150 1x1 GSM160 Varia 260 320 Ø160 260 320 mm 250 mm HSI150 1x1 GSM160 Varia 320 425 Ø160 320 425 mm 250 mm HSI150 1x1 GSM160 Varia 425 530 Ø160 425 530 mm 250 mm HSI150 1x1 GSM160 Varia 530...

Page 27: ...zędzia i środki pomocnicze 27 4 Opis 27 5 Przygotowanie montażu 27 6 Montaż 28 7 Przygotowanie do montażu złącza rurowego czynności robocze 1 i 2 tylko w przypadku produktu HSI150 GSM110 125 160 Varia 29 8 Przygotowanie do montażu pokrywy systemowej uszczelnienia systemu 30 Opis Przepust kablowy HSI150 K2 Varia patrz ilustr 2 Legenda dotycząca ilustracji 2 1 Rura przedłużająca z podziałką np 260 3...

Page 28: ...ablowych HSI150 1x1 GSM110 125 Varia zalecamy stosowanie elementów dystansowych HSI AH40 akce soria Pozwoli to na zapewnienie lepszej jakości zagęszczania wykopu rury osłonowej w planowanych ciągach rur ochronnych o średnicy zewnętrznej 160 mm Dodatkową zaletą jest zapewnienie minimalnej odległości Jeśli np ze względu na miejsce nie jest stoso wany element dystansowy HSI AH40 podczas betonowania a...

Page 29: ...y uszczelnieniami trójrowkowymi a zbrojeniem konieczne jest zachowanie odległości wynoszącej przynajmniej 5 cm Drut karbowany nie może być zamocowany do uszczelnienia trójrowkowego 7 Przygotowanie do montażu złącza rurowego czynności robocze 1 i 2 tylko w przypadku produktu HSI150 GSM110 125 160 Varia 1 Po betonowaniu i przed podłączeniem rury osłonowej należy z wtykowej mufy gumowej usunąć pokryw...

Page 30: ...wiedniej instrukcji montażu pokrywy systemowej uszczelnienia systemo wego Oznaczenie dotyczy przyłączy rur osłonowych Do grubości ścian Rozstaw osi z elementem dystansowym bez elementu dystansowego HSI150 1x1 GSM110 Varia 200 260 Ø110 200 260 mm 250 mm 210 mm HSI150 1x1 GSM110 Varia 260 365 Ø110 260 365 mm 250 mm 210 mm HSI150 1x1 GSM110 Varia 365 470 Ø110 365 470 mm 250 mm 210 mm HSI150 1x1 GSM11...

Page 31: ... Podłączenia rury osłonowej Głębokość wciskania Ø110 60 mm Ø125 60 mm Ø160 70 mm Tabela 3 Typ Varia Do grubości ścian HSI150 K2 Varia 200 260 200 260 mm HSI150 K2 Varia 260 365 260 365 mm HSI150 K2 Varia 365 470 365 470 mm HSI150 K2 Varia 470 575 470 575 mm Tabela 2 Telefon działuserwisowego 4973221333 0 Zastrzega siê prawo do wprowadzania zmian ...

Page 32: ...32 Art Nr 5090032093 Rev 01 2020 01 08 EN Notizen Notes Remarques Opmerkingen Notatki ...

Page 33: ...1 2020 01 08 Art Nr 5090032093 Rev 01 2020 01 08 33 4 3 EN Notizen Notes Remarques Opmerkingen Notatki HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia 13 14 9 1 11 1 1 2 15 1 2 16 2 1 17 18 10 2 1 12 1 2 3 ...

Page 34: ...032093 Rev 01 2020 01 08 HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Montageanleitung HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Kabeldurchführung mit variabler Längeneinstel lung DE Installation instructions HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Cable entry with adjustable length setting EN Notice de montage HSI150 1x1 GSM110 125 160 Varia HSI150 1x1 K2 Varia Passe ...

Reviews: