background image

™ 

IMAGETEAM™ 2020/5620

Cordless System

System Manual

Summary of Contents for IMAGETEAM 2020

Page 1: ... IMAGETEAM 2020 5620 Cordless System System Manual ...

Page 2: ...rein nor for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Hand Held Products 2004 2005 Hand Held Products Inc Al...

Page 3: ...evice pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications If this equipment does cause harmful interference...

Page 4: ...RF exposure guidelines for body worn operation do not use accessories that contain metallic components and ensure that the device is at least 15mm 0 6 inches from the body Canadian Compliance This Class B digital apparatus compiles with Canadian ICES 003 Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference ...

Page 5: ...e Federal Communications Commission FCC Bluetooth Radio Device R TTE Compliance Statement These devices are in conformity with all essential requirements of the R TTE Directive 1999 5 EC This equipment has been assessed to the following standards This product is marked with in accordance with the product requirements specified in the R TTE Directive 1999 5 EC The equipment is intended for use thro...

Page 6: ...tement TÜV or GS marked to EN60950 and EN60825 1 C Tick Statement Conforms to AS NZS 3548 C Tick number N10410 Mexico Patents Please refer to the IT5620 packaging for patent information Solids and Water Protection The IT5620 has a rating of IP41 immunity of foreign particles and dripping water Certified ...

Page 7: ...Required Safety Labels IT5620 ...

Page 8: ...g g 0 0 D G D Q D F Q V W F X G R U 3 G O H G Q D 1 V O O D V H O H W D H Q D N 6 D Q L K Q L H G D 0 J Q L G Q H 3 V W Q H W D 3 Q J L H U R G Q D 6 8 7 5 2 6 6 M O C D L E H D N A H W W W IT2020 ...

Page 9: ... Changing Scanner Name Serially 1 8 Changing Scanner Name via Bar Codes 1 9 Scanner Report 1 10 Application Work Groups 1 10 Application Work Group Selection 1 11 Resetting the Standard Product Default Settings Current Application Work Group 1 12 Resetting the Standard Product Default Settings All Application Work Groups 1 12 Using the Scanner with Bluetooth Devices 1 13 Changing Bluetooth PIN Cod...

Page 10: ...lation Plug Play 1 22 IBM 4683 Ports 5B 9B and 17 Interface 1 23 Connecting the Base with USB 1 24 IBM SurePos 1 25 USB PC or Macintosh Keyboard 1 25 USB HID 1 26 USB Com Port Emulation 1 26 Connecting the Base with Serial Wedge 1 27 Chapter 2 Terminal Interfaces Terminal ID 2 1 Supported Terminals 2 2 Keyboard Country 2 4 Keyboard Style 2 5 Keyboard Modifiers 2 6 Connecting the Base with RS 232 S...

Page 11: ...Beeper Volume Good Read 3 1 Beeper Pitch Good Read 3 2 Beeper Duration Good Read 3 2 LED Good Read 3 2 Number of Beeps Good Read 3 3 Good Read Delay 3 3 User Specified Good Read Delay 3 3 Scanner Trigger Modes 3 4 Manual Serial Trigger Low Power 3 4 Automatic Trigger 3 5 Presentation Mode 3 5 Hands Free Time Out 3 6 Reread Delay 3 6 User Specified Reread Delay 3 6 Centering Window 3 7 Output Seque...

Page 12: ...er Delay 4 5 User Specified Intercharacter Delay 4 5 Interfunction Delay 4 6 Intermessage Delay 4 6 Chapter 5 Data Formatting Data Format Editor Introduction 5 1 To Add a Data Format 5 1 Other Programming Selections 5 2 Data Format Editor Commands 5 2 Data Format Editor 5 4 Data Formatter 5 5 Alternate Data Formats 5 5 Chapter 6 Symbologies Introduction 6 1 All Symbologies 6 1 Message Length 6 2 C...

Page 13: ... 2 of 5 Message Length 6 12 IATA Code 2 of 5 Message Length 6 13 Matrix 2 of 5 6 13 Matrix 2 of 5 Message Length 6 14 Code 11 6 14 Check Digits Required 6 14 Code 11 Message Length 6 15 Code 128 6 15 ISBT 128 Concatenation 6 16 Code 128 Message Length 6 16 Code 128 Code Page 6 16 Code 128 Function Code Transmit 6 17 Telepen 6 17 Telepen Output 6 17 Telepen Message Length 6 18 UPC A 6 18 UPC A Chec...

Page 14: ...nslate 6 25 EAN JAN 8 6 25 EAN JAN 8 Check Digit 6 25 EAN JAN 8 Addenda 6 26 EAN JAN 8 Addenda Required 6 26 EAN JAN 8 Addenda Separator 6 26 MSI 6 27 MSI Check Character 6 27 MSI Message Length 6 28 Plessey Code 6 28 Plessey Message Length 6 28 RSS Limited 6 29 RSS Expanded 6 30 RSS Expanded Message Length 6 30 EAN UCC Emulation 6 30 China Post Code 6 31 Korea Post Code 6 32 Korea Post Message Le...

Page 15: ... Settings Current Application Work Group 8 2 Resetting the Standard Product Default Settings All Application Work Groups 8 3 Temporary Visual Menu 2003 Configuration 8 3 Chapter 9 Visual Menu 2003 Visual Menu 2003 Introduction 9 1 Installing Visual Menu 2003 from the Web 9 1 Chapter 10 Serial Programming Commands Conventions 10 1 Menu Command Syntax 10 1 Query Commands 10 2 Concatenation of Multip...

Page 16: ...aintenance Maintenance 12 1 Cleaning the Scanner s Window 12 1 Inspecting Cords and Connectors 12 1 Replacing the IT2020 Interface Cable 12 2 Troubleshooting Base 12 2 Chapter 13 Customer Support Product Service and Repair 13 1 Online Product Service and Repair Assistance 13 2 Technical Assistance 13 2 Online Technical Assistance 13 2 Limited Warranty 13 2 Appendix A Symbology Chart A 1 ASCII Conv...

Page 17: ...bility an advanced two way spread spectrum radio Bluetooth wireless technology a wide range of interfaces keyboard wedge wand emulation RS 232 terminals USB and legacy decoders visible and audible feedback for confirmation of a successful decode a rechargeable battery designed to operate through a whole work day The cordless system can be programmed for many communication parameters and input outp...

Page 18: ...ered is present Save the shipping container for later storage or shipping Check for damage during shipment Report damage immediately to the carrier who delivered the carton Models Models Description 2020 5A Base Keyboard wedge TTL level 232 TTL level 232 serial wedge IBM 4683 wand emulation USB keyboard USB HID USB retail IBM SurePOS 2020 CB Base with charger only no host interfaces 5620SR0C0 Cord...

Page 19: ...dless scanner by a rechargeable battery that is integrated in the scanner handle Each scanner is shipped with a battery See Product Specifications beginning on page 11 1 Charging Information The battery is designed to charge while the scanner is positioned in the cordless base unit Refer to IT2020 LED Sequences and Their Meaning on page 1 15 for an interpretation of the Charge Status indicators Pl...

Page 20: ...mes it will eventually be depleted Replace it after the battery is unable to hold an adequate charge If you are not sure if the battery or charger is working properly send it to Hand Held Products or an authorized Hand Held Products service center for inspection Proper Disposal of the Battery When the battery has reached the end of its useful life the battery should be disposed of by a qualified r...

Page 21: ...t power source only The chart below describes each selection by condition Using a slow charge rate draws less current power from the input power source when the battery is mostly discharged Scan the appropriate bar code for your application Default Automatic Condition 1 Condition 2 Condition 3 Automatic Fast Charge Slow Charge No Charge Full Charge Rate Fast Charge Fast Charge No Charge Low Charge...

Page 22: ... cordless system is set up correctly scan one of the sample bar codes in the back of this manual If the scanner provides a single good read beep and the green LED lights the scanner has successfully linked to the base If you receive a triple error beep and the red LED lights the scanner has not linked to the base Scanner Modes The IT5620 is capable of working in single scanner mode multiple scanne...

Page 23: ...nner by scanning the Unlink Scanner bar code See Scanner Modes on page 1 6 Open Link Mode Single Scanner When newly shipped or defaulted to factory settings the base and scanner are not linked By placing an scanner into the base they establish a link Placing a different scanner into the base establishes a new link and the old scanner is unlinked Each time an scanner is placed into the base it beco...

Page 24: ...anners linked to one base so that you will be able to control the scanner receiving imaging commands sent from the base The default name for an IT5620 is IT5620 If you have more than one IT5620 linked to a base the first scanner that is linked to the base receives commands addressed using this name Changing Scanner Name Serially If you wish to change the name you may change it via a serial command...

Page 25: ... code below with the first scanner scan the 1 bar code on the Programming Chart inside the back cover of this manual and scan Save Then scan the Reset bar code and wait for the scanner to re link to the base before scanning the next bar code Repeat that process for scanner number 2 3 4 etc If you want to assign an alphabetic name to the scanner create a Code 128 bar code containing BT_NAMname foll...

Page 26: ...rk group and may program each scanner independently Visual Menu 2003 page 9 1 makes it easy for you to program your system for use with multiple scanners and multiple work groups The scanner keeps a copy of the menu settings it is using Whenever the scanner is connected or reconnected to a base the scanner is updated with the latest settings from the base for its work group The scanner also receiv...

Page 27: ...This programming selection allows you to assign an scanner to a work group by scanning the bar code below You may then program the settings e g beeper volume prefix suffix data formatter that your application requires Group 0 Group 1 Group 2 Group 4 Group 6 Group 3 Group 5 ...

Page 28: ... to Base on page 1 6 for additional information Note If your scanner is in multiple scanner mode and you scan either the current or all application group default bar code you will hear up to 30 seconds of beeping while all scanners are re linked from the base and the settings are defaulted to settings The default interface is keyboard wedge and the default scanner mode is single scanner locked lin...

Page 29: ...ode Some devices require a PIN code as part of the Bluetooth security features Your scanner s default PIN is 1234 which you may need to enter the first time you connect to your PDA or PC The PIN code must be numeric and between 1 and 16 characters To change the PIN scan the bar code below and then scan the appropriate numeric bar codes from the Programming Chart inside the back cover of this manua...

Page 30: ... fit your application Data Accumulation Mode Scan the bar codes below to turn data accumulation batch mode on and off If data accumulation mode is on bar code data is stored when the scanner is out of range of the base and transmitted once the scanner is back in range Beeper and LED Sequences and Their Meaning The IT5620 contains LEDs on the top of the unit to indicate its power up communication a...

Page 31: ...al Operation Red Flash None Battery low Green Flash 1 beep Successful communication or linking Red blinking 3 beeps Failed communication Menu Operation Green Flash 2 beeps Successful menu change Red blinking 3 beeps Unsuccessful menu change System Condition System Status Indicator Red LED Power On System Idle LED is on Power On Diagnostic Error Blink LED for long duration pulsing indefinitely Rece...

Page 32: ...ds according to the Charge Status Indicator table above The base can be powered by the Host parasitic power mode If the base is in parasitic power mode without the 9VDC power source the base will still function but will not charge the battery RF Radio Frequency Module Operation The cordless system uses a state of the art two way Bluetooth radio to transmit and receive data between the scanner and ...

Page 33: ...d software automatically detects the imager and links it to the base depending on the selected link mode Scanner Is Out of Range The cordless scanner is in communication with its base even when it is not transmitting bar code data Whenever the scanner can t communicate with the base for a few seconds it is out of range If the scanner is out of range and you scan a bar code the scanner issues a tri...

Page 34: ...or the base indicates that the data sent was received by the host The cordless scanner recognizes data acknowledgement ACK from the base unit If it cannot be determined that the data has been properly sent to the base the scanner issues an error indication You must then check to see if the scanned data was received by the host system Connecting the Base When Powered by Host Keyboard Wedge A base c...

Page 35: ...yboard wedge interface See Keyboard Wedge Connection on page 1 21 6 Verify the base operation by scanning a bar code from the Sample Symbols in the back of this manual Note Without using the 9 volt external power supply the base only uses enough power from the host to operate the interface The scanner s battery is not charged when in this mode Using the 9 volt external power supply allows the scan...

Page 36: ...e aiming line on the symbol Resetting the Standard Product Defaults If you aren t sure what programming options are in your scanner or you ve changed some options and want the factory settings restored scan the Standard Product Default Settings bar code below The Menu Commands starting on page 10 6 lists the factory default settings for each of the commands indicated by an asterisk on the programm...

Page 37: ... allows operation of the scanner in parallel with the integral keyboard The following Laptop Direct Connect bar code selects terminal ID 03 programs a carriage return CR suffix and turns on Emulate External Keyboard page 2 5 RS 232 The RS 232 Interface bar code is used when connecting to the serial port of a PC or terminal The following RS 232 Interface bar code also programs a carriage return CR ...

Page 38: ...converts all other symbologies to Code 39 The Wand Emulation Plug Play Code 39 Format bar code below sets the terminal ID to 61 The Wand Emulation Plug Play Same Code Format bar code sets the terminal ID to 64 These Plug Play bar codes also set the Transmission Rate to 25 inches per second Output Polarity to black high and Idle State to high If you want to change the terminal ID only without chang...

Page 39: ...s the following suffixes for each symbology Suffixes programmed for Code 128 with IBM 4683 Port 5B IBM 4683 Port 9B HHBCR 1 and IBM 4683 Port 17 Interfaces Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR 2 Interface Symbology Suffix EAN 8 0C EAN 13 16 UPC A 0D UPC E 0A Code 39 00 0A 0B Interleaved 2 of 5 00 0D 0B Code 128 00 0A 0B Code 128 00 18 0B IBM 4683 Port 5B Interface IBM 4683 P...

Page 40: ...tion by scanning a bar code from the Sample Symbols in the back of this manual For additional USB programming and technical information refer to Hand Held Products USB Application Note available at www handheld com Note Without using the 9 volt external power supply the base only uses enough power from the host to operate the interface The scanner s battery is not charged when in this mode Using t...

Page 41: ...ng suffixes for each symbology USB PC or Macintosh Keyboard Scan one of the following codes to program the IT5620 for USB PC Keyboard or USB Macintosh Keyboard Scanning these codes adds a CR and LF along with selecting the terminal ID USB PC Keyboard 124 USB Macintosh Keyboard 125 Symbology Suffix EAN 8 0C EAN 13 16 UPC A 0D UPC E 0A Code 39 00 0A 0B Interleaved 2 of 5 00 0D 0B Code 128 00 18 0B I...

Page 42: ...s PC you will need to download a driver from the Hand Held Products website www handheld com The driver will use the next available Com Port number Apple Macintosh computers recognize the scanner as a USB CDC class device and automatically uses a class driver Scanning the code below changes the terminal ID to 130 Note No extra configuration e g baud rate is necessary CTS RTS Emulation ACK NAK Mode...

Page 43: ...existing serial cable from the computer 3 Connect the appropriate interface cable to the base Note For the base to work properly you must have the correct cable for your type of computer 4 Plug the serial connector into the serial port on your computer Tighten the two screws to secure the connector to the port 5 Plug the other serial connector into the other device connection and tighten the two s...

Page 44: ...al wedge terminal ID use the serial terminal ID 050 and follow the instructions on page 2 1 Make sure that all of the communication parameters match on all of the connected devices Choosing Both sends scanned data to P1 and P2 Default P1 P1 P2 Both P1 and P2 ...

Page 45: ...your terminal ID Scan Save to save your selection For example an IBM AT terminal has a Terminal ID of 003 You would scan the Terminal ID bar code then 0 0 3 from the Programming Chart inside the back cover of this manual then Save If you make an error while scanning the digits before scanning Save scan the Discard code on the Programming Chart scan the Terminal ID bar code scan the digits and the ...

Page 46: ...2 3488 008 IBM 122 key 3180 024 IBM 122 key 3180 data entry keyboard 114 IBM DOS V 106 key PC Workstation 102 IBM SurePOS USB Hand Held Scanner 128 IBM SurePOS USB Tabletop Scanner 129 IBM Thinkpad 360 CSE 340 750 097 IBM Thinkpad 106 IBM Thinkpad 365 755CV 003 I O 122 key 2676D 2677C 2677D 008 ITT 9271 007 Lee Data IIS 007 NEC 98XX Series 103 Olivetti M19 M200 001 Olivetti M240 M250 M290 M380 P50...

Page 47: ...terfaces rather than scanning the terminal ID listed in this table Telex 122 key 078 078A 79 80 191 196 1191 1192 1471 1472 1476 1477 1482 1483 046 USB PC Keyboard 124 USB Mac Keyboard 125 USB Com Port 130 USB HIDPOS 131 Wand Emulation Code 39 Format 061 Wand Emulation Same Code Format 064 Supported Terminals Continued Terminal Model s Terminal ID ...

Page 48: ...ry code below to program the keyboard for your country As a general rule the following characters are supported but need special care for countries other than the United States United States Denmark France Germany Austria Great Britain Italy Norway Spain Switzerland Belgium Finland ...

Page 49: ...f Caps Lock is used when you normally have the Caps Lock key on Shift Lock is used when you normally have the Shift Lock key on not common to U S keyboards Automatic Caps Lock is used if you change the Caps Lock key on and off The software tracks and reflects if you have Caps Lock on or off AT and PS 2 only This selection can only be used with systems that have an LED which notes the Caps Lock sta...

Page 50: ...ASCII Mode On The scanner sends key combinations for ASCII control characters for values 00 1F Refer to Keyboard Function Relationships page 7 1 for CTRL ASCII Values Default Off Turbo Mode The scanner sends characters to a terminal faster If the terminal drops characters do not use Turbo Mode Default Off Numeric Keypad Mode Sends numeric characters as if entered from a numeric keypad Default Off ...

Page 51: ...te interface cable to the base Note For the base to work properly you must have the correct cable for your type of terminal computer 3 Plug the serial connector into the serial port on your computer Tighten the two screws to secure the connector to the port 4 Plug the power supply barrel connector to the base and plug the power supply into the AC source 5 Once the base has been fully connected pow...

Page 52: ...232 interface bar code programs the scanner for an RS 232 interface at 115 200 baud parity none 8 data bits 1 stop bit and adds a suffix of a CR LF RS 232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the scanner Default 115 200 RS 232 Interface 300 2400 600 1200 4800 38400 9600 19200 115 200 57 600...

Page 53: ...a bits For applications which require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for validity Default None 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 2 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity None 8 Dat...

Page 54: ... indicators emitted from the source scanner Turning the Host ACK selection on configures the cordless system scanners to respond to commands from the host system The following criteria must be met for the Host ACK to work correctly The cordless system must be configured for Host Port RS 232 Terminal ID 000 RTS CTS is defaulted off You must enable it if the host system requires it Host ACK must be ...

Page 55: ... The scanner reads a code and sends data to the base host system No audible or visual indication is emitted until you receive an escape command The scanner read illumination goes out upon a successful read Scanner is suspended until 1 a valid escape string is received from the host system via the base or 2 the scanner times out Once condition 1 or 2 above has been met the scanner is ready to scan ...

Page 56: ...Illuminate green LED for two seconds followed by at least 500 mSecs dark time when multiple blinks ESC 3 Illuminate green LED for five seconds followed by at least 500 mSecs dark time when multiple blinks ESC 4 One beep at low volume ESC 5 One beep at medium volume ESC 6 One beep at high volume ESC 7 Indicate as successful decode and communication to host ESC 8 Indicate as unsuccessful decode and ...

Page 57: ...to changing the terminal ID Please refer to Wand Emulation Plug Play on page 1 22 for further information In Wand Emulation mode the imager decodes the bar code then sends data in the same format as a wand imager The Code 39 Format converts all symbologies to Code 39 The Same Code Format transmits UPC EAN Code 128 and Interleaved 2 of 5 without any changes but converts all other symbologies to Cod...

Page 58: ...rate is limited by the terminal s ability to receive data without dropping characters Default 25 inches second Wand Emulation Polarity The Polarity can be sent as standard with black bars high or reversed with white bars high Default Black High 10 80 25 40 120 150 200 Black High White High ...

Page 59: ...set the scanner s idle state to match the idle state for the device to which the scanner is connected Default Idle High Wand Emulation Data Block Size This transmits the data in smaller blocks to prevent buffer overflow Default 40 Wand Emulation Delay Between Blocks This sets the delay time between data blocks Default 50ms Idle High Idle Low 20 80 40 60 5ms 500ms 50ms 150ms ...

Page 60: ...ned on a computed check character is added at the end of the entire message The check character is the character which when Exclusive OR d with every preceding character of the message yields a result of 0x00 00H Default Off Wand Emulation Overall Checksum Off Wand Emulation Overall Checksum On ...

Page 61: ...esponse to a good read Turning this option off only turns off the beeper response to a good read indication All error and menu beeps are still audible Default On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read Default Medium Beeper Good Read On Beeper Good Read Off High Medium Off Low ...

Page 62: ...ood read Default Medium Beeper Duration Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal LED Good Read The LED indicator can be programmed On or Off in response to a good read Default On Low 1600 Hz Medium 3250 Hz High 4200 Hz Normal Beep Short Beep LED Good Read On LED Good Read Off ...

Page 63: ...eps scan the bar code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default One Good Read Delay This sets the minimum amount of time before the scanner can read another bar code Default 0 ms No Delay User Specified Good Read Delay If you want to set your own length for the good read delay scan the bar code below then se...

Page 64: ...al Trigger Mode Use this selection to set a time out in milliseconds of the scanner s trigger when using serial commands to trigger the scanner Once the scanner has timed out you can activate the scanner either by pressing the trigger or using a serial trigger command After scanning the Read Time Out bar code set the time out duration from 0 300 000 milliseconds by scanning digits on the Programmi...

Page 65: ...r down mode pull the trigger to power the unit back up There will be a set of power up beeps and a delay of up to a few seconds for the radio to join The scanner will then be ready to use Automatic Trigger The scanner scans continuously at full power with illumination fully on Presentation Mode The LEDs are off until a bar code is presented to the scanner Then the LEDs turn on automatically to rea...

Page 66: ...de back cover and Save Default 5 000 ms Reread Delay This sets the time period before the scanner can read the same bar code a second time Setting a reread delay protects against accidental rereads of the same bar code Longer delays are effective in minimizing accidental rereads at POS point of sale Use shorter delays in applications where repetitive bar code scanning is required Default Medium Re...

Page 67: ...de must be within the window to be decoded or output by the scanner To change the left or right edge of the centering window scan Centering On then scan one of the following bar codes Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual Scan Save Default Centering 40 for Left 60 for Right The figure below illustrates the percentage range...

Page 68: ...whatever order your application requires regardless of the order in which the bar codes are scanned Reading the Default Sequence symbol programs the scanner to the Universal values shown below These are the defaults Be certain you want to delete or clear all formats before you read the Default Sequence symbol Note To make Output Sequence Editor selections you ll need to know the code I D code leng...

Page 69: ...this manual to read the alphanumeric combination that represents the ASCII characters 99 is the Universal num ber indicating all characters 5 End Output Sequence Editor Scan F F to enter an Output Sequence for an additional symbology or Save to save your entries Other Programming Selections Discard This exits without saving any Output Sequence changes Output Sequence Editor Require Output Sequence...

Page 70: ...put Code 39 1st Code 128 2nd and Code 93 3rd as shown below Note Code 93 must be enabled to use this example You would set up the sequence editor with the following command line SEQBLK62999941FF6A999942FF69999943FF The breakdown of the command line is shown below SEQBLKsequence editor start command 62 code identifier for Code 39 9999 code length that must match for Code 39 9999 all lengths Require...

Page 71: ... formatted characters as part of the length If you use the example on page 3 10 but assume a CR suffix and specific code lengths you would use the following command line SEQBLK62001241FF6A001342FF69001243FF The breakdown of the command line is shown below SEQBLK sequence editor start command 62 code identifier for Code 39 0012 A Code 39 sample length 11 plus CR suffix 1 12 41 start character match...

Page 72: ...n the scanner sends an NR to the host if you pull and release the trigger without reading a code e g bad bar code If No Read is turned Off the NR will not be sent to the host If you want a different notation than NR for example Error or Bad Code you can edit the output message using the Data Formatter page 5 5 The hex code for the No Read symbol is 9C Video Reverse Video Reverse is used to allow t...

Page 73: ...Points to Keep In Mind It is not necessary to build a message string The selections in this chapter are only used if you wish to alter the default settings Default prefix None Default suffix None A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the ASCII Conversion Chart Code Page 1252 on page A 2 plus Code I D and AIM I D You c...

Page 74: ...uffix character Step 7 To add the Code I D scan 5 C 8 0 To add AIM I D scan 5 C 8 1 To add a backslash scan 5 C 5 C Note To add a backslash as in Step 7 you must scan 5C twice once to create the leading backslash and then to create the backslash itself Step 8 Scan Save to exit and save or scan Discard to exit without saving Repeat Steps 1 6 to add a prefix or suffix for another symbology Example A...

Page 75: ...digit Hex value from the Symbology Chart included in the Appendix A for the symbology from which you want to clear the pre fix or suffix Step 3 Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual or scan 9 9 for all symbologies Your change is automatically saved To Add a Carriage Return Suffix to all Symbologies Scan the following bar code if you wish to add ...

Page 76: ...anner is in keyboard wedge mode the scan code is converted to a key code before it is transmitted Default Enable Intercharacter Interfunction and Intermessage Delays Some terminals drop information characters if data comes through too quickly Intercharacter interfunction and intermessage delays slow the transmission of data increasing data integrity Each delay is composed of a 5 millisecond step Y...

Page 77: ...ion User Specified Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed after the transmission of a particular character of scanned data Scan the Delay Length bar code below then scan the number of milliseconds and the SAVE bar code using the Programming Chart inside the back cover of this manual Next scan the Character to Trigger Delay bar code then the 2 digit hex...

Page 78: ...gramming Chart inside the back cover of this manual Intermessage Delay An intermessage delay of up to 495 milliseconds may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan the number of milliseconds and the SAVE bar code using the Programming Chart inside the back cover of this manual To remove this delay scan the Intermessage Delay bar code then set th...

Page 79: ...ctual Length 6 Universal Term ID Actual Code ID Universal Length 7 Universal Term ID Universal Code ID Actual Length 8 Universal Term ID Universal Code ID Universal Length If you have changed data format settings and wish to clear all formats and return to the factory defaults scan the Default Data Format code on page 5 4 To Add a Data Format Step 1 Scan the Enter Data Format symbol page 5 4 Step ...

Page 80: ... you are clearing an alternate format scan 1 2 or 3 depending on the alternate format you are clearing Scan the Terminal Type refer to the Supported Terminals Chart on page 2 2 Code I D refer to the Symbology Chart on page A 1 and the bar code data length for the specific data format that you want to delete All other formats remain unaffected Save from the Programming Chart inside the back cover o...

Page 81: ...ter Syntax F8xx xx stands for the hex value for an ASCII code see ASCII Conversion Chart Code Page 1252 on page A 2 F9 Search back for xx character from current cursor position leaving cursor pointing to xx character Syntax F9xx xx stands for the hex value for an ASCII code see ASCII Conversion Chart Code Page 1252 on page A 2 E6 Search ahead for the first non xx character from the current cursor ...

Page 82: ...FE Compare character in current cursor position to the character xx If char acters are equal increment cursor If characters are not equal no format match Syntax FExx xx stands for the hex value for an ASCII code see ASCII Conversion Chart Code Page 1252 on page A 2 EC Check to make sure there is an ASCII number at the current cursor position If character is not numeric format is aborted Syntax EC ...

Page 83: ...le shot capability to scan one bar code using a different data format than your primary format When data formats are programmed see page 5 1 you must input whether you are programming the primary format or an alternate format numbered 1 2 or 3 An alternate format is initiated by scanning one of the 3 alternate format bar codes below The scanner will scan the next bar code formatting the data with ...

Page 84: ...5 6 IMAGETEAM 2020 5620 System Manual ...

Page 85: ...gies On code If on the other hand you want to decode only a particular symbology scan All Symbologies Off followed by the On symbol for that particular symbology All Symbologies IATA Code 2 of 5 China Post Interleaved 2 of 5 Codabar Korea Post Codablock F Matrix 2 of 5 Code 2 of 5 Coupon Code Code 11 MSI Code 16K Plessey Code Code 39 PosiCode Code 32 Pharmaceutical PARAF RSS 14 Code 49 Telepen Cod...

Page 86: ...lps reduce the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes included in the explanation of the symbology then scan the digit value of the messag...

Page 87: ...check characters are created using different modulos You can program the scanner to read only Codabar bar codes with Modulo 16 check characters Default No Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate and Transmit the scanner will only read Codabar bar codes printed with a ch...

Page 88: ...er looks for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two messages are concatenated into one with the D characters omitted Default On Select Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters No Check Character ...

Page 89: ...nimum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Code 39 Default All Code 39 Settings Code 39 Code 39 Start Stop Characters Start Stop characters identify the leading and trailing ends of the bar code You may either transmit or not transmit Start Stop characters Default Don t Transmit Minimum Message Length Maximum Message Length On Off Transmit Don t Transmit ...

Page 90: ...r with the scanned data When Check Character is set to Validate and Transmit the scanner only reads Code 39 bar codes printed with a check character and will transmit this character at the end of the scanned data Default No Check Character Code 39 Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum ...

Page 91: ... with a space excluding the start and stop symbols and does not immediately transmit the data The scanner stores the data in the order in which the bar codes are read deleting the first space from each The scanner transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space Default Off Code 32 Pharmaceutical PARAF Code 32 Pharmaceutical is a form of ...

Page 92: ...ign and period respectively Character pairs P through Y decode as 0 through 9 NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D T T d D t T ENQ E NAK U E 5 5 E E U U e E u U ACK F SYN V F 6 6 F F V V f F v V BEL G ETB W G 7 7 G G W W g G w W BS H CAN X H 8 8 H H X X h H x X HT I EM Y I 9 ...

Page 93: ... the case scan the bar code below select the code page with which the bar codes were created from the chart Code Page Mapping of Printed Bar Codes on page A 4 and scan the value and the SAVE bar code from the Programming Chart inside the back cover of this manual The data characters should then appear properly Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings Interleaved 2 of 5 Check Digi...

Page 94: ...anner only reads Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Validate but Don t Tran...

Page 95: ...ata received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created from the chart Code Page Mapping of Printed Bar Codes on page A 4 and scan the value and the SAVE bar co...

Page 96: ...Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 IATA Code 2 of 5 Default All Code IATA 2 of 5 Settings On Off Minimum Message Length Maximum Message Length ...

Page 97: ...the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Matrix 2 of 5 Default All Matrix 2 of 5 Settings Matrix 2 of 5 On Off Minimum Message Length Maximum Message Length On Off ...

Page 98: ...2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 11 Default All Code 11 Settings Code 11 Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes Default Two Check Digits Minimum Message Length Maximum Message Length On Off One Check Digit Two Check Digits ...

Page 99: ...n the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 128 Default All Code 128 Settings Code 128 Minimum Message Length Maximum Message Length On Off ...

Page 100: ...ult Off Code 128 Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Code 128 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code bei...

Page 101: ...n Default All Telepen Settings Telepen Telepen Output Using AIM Telepen Output the scanner reads symbols with start stop pattern 1 and decodes them as standard full ASCII start stop pattern 1 When Original Telepen Output is selected the scanner reads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output Fun...

Page 102: ...6 2 for additional information Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 UPC A Default All UPC A Settings UPC A UPC A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On Minimum Message Length Maximum Message Length On Off On Off ...

Page 103: ...not transmit it Default On UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda UPC A Addenda Required When Addenda Required is set to on the scanner will only read UPC A bar codes that have addenda Default Not Required Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required R...

Page 104: ...space between the data from the bar code and the data from the addenda When turned off there is no space Default On UPC A EAN 13 with Extended Coupon Code Use the following codes to enable or disable UPC A and EAN 13 with Extended Coupon Code Default On UPC E Default All UPC E Settings Off On On Off ...

Page 105: ... number system use the UPC E1 selection Default On UPC E0 and Off UPC E1 UPC E0 and UPC E1 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off UPC E0 and UPC E1 Addenda Required When Addenda Required is set to on the scanner will only read UPC E bar codes that have addenda Default Not Required UPC E0 On UPC E0 Off UPC E1 On UPC E1 Off Off On Not Required Required ...

Page 106: ...urned off there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On UPC E0 Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On Off On Off On Off On ...

Page 107: ...f for both 2 Digit and 5 Digit Addenda EAN JAN 13 Default All EAN JAN Settings EAN JAN 13 EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On On Off Off On ...

Page 108: ...d When Addenda Required is set to on the scanner will only read EAN JAN 13 bar codes that have addenda Default Not Required EAN JAN 13 Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Requi...

Page 109: ...ge 6 20 ISBN Translate This selection causes EAN 13 Bookland symbols to be translated into their equivalent ISBN number format Default Off EAN JAN 8 Default All EAN JAN 8 Settings EAN JAN 8 EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On Off On On Off Off On ...

Page 110: ...d When Addenda Required is set to on the scanner will only read EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Require...

Page 111: ...n Check Character is set to Validate and Transmit the scanner will only read MSI bar codes printed with the specified type check character and will transmit this character at the end of the scanned data When Check Character is set to Validate but Don t Transmit the unit will only read MSI bar codes printed with the specified type check character but will not transmit the check character with the s...

Page 112: ...8 Minimum Default 4 Maximum Default 48 Plessey Code Default All Plessey Code Settings Plessey Code Plessey Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Minimum Message Length Maximum Message Length On Off Minimum Message Length Maximum Message...

Page 113: ...IMAGETEAM 2020 5620 System Manual 6 29 RSS 14 Default All RSS 14 Settings RSS 14 RSS Limited Default All RSS Limited Settings RSS Limited On Off On Off ...

Page 114: ...aximum lengths 4 74 Minimum Default 4 Maximum Default 74 EAN UCC Emulation The imager can automatically format the output from any EAN UCC data carrier to emulate what would be encoded in an equivalent UCC EAN 128 or RSS Composite symbol EAN UCC data carriers include UPC A and UPC E EAN 13 and EAN 8 ITF 14 UCC EAN 128 and EAN UCC RSS and Composites If UCC EAN 128 Emulation is selected the AIM Symb...

Page 115: ...gnize one data carrier type Default EAN UCC Emulation Off China Post Code Default All China Post Code Settings China Post Code China Post Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 RSS Emulation 128 Emulation EAN UCC Emulation Off On Off Min...

Page 116: ...de Korea Post Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 PosiCode Default All PosiCode Settings On Off Minimum Message Length Maximum Message Length ...

Page 117: ...ge Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 On Off A and B On No Limited A and B and Limited A On Limited B Off A and B and Limited B On Limited A Off Minimum Message Length Maximum Message Length ...

Page 118: ...codes Trioptic Code must be off Codablock F Default All Codablock F Settings Codablock F Codablock F Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 On Off On Off Minimum Message Length Maximum Message Length ...

Page 119: ...K Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 0 160 Minimum Default 1 Maximum Default 160 Code 49 Default All Code 49 Settings On Off Minimum Message Length Maximum Message Length ...

Page 120: ... Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 81 Minimum Default 1 Maximum Default 81 On Off Minimum Message Length Maximum Message Length ...

Page 121: ...als that can be used with the scanner Refer to page 2 6 enable Control ASCII mode Function Code HEX ASCII Value Full ASCII CTRL NUL 00 2 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS 1E 6 US 1F ...

Page 122: ... CTRL column 6 apply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany à 6 Italy 6 Switzerland 6 United Kingdom 6 Denmark 8 9 6 Norway 8 9 6 Spain 6 ...

Page 123: ...r CR Enter New Line BS 08 Reserved Reserved F16 HT 09 Tab Tab F17 LF 0A Reserved Reserved F18 VT 0B Tab Tab Tab Field Forward FF 0C Delete Delete Delete CR 0D CR Enter CR Enter Field Exit New Line SO 0E Insert Insert Insert SI 0F Escape Escape F19 DLE 10 F11 Reserved Error Reset DC1 11 Home Home Home DC2 12 Print Print F20 DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Backfield ...

Page 124: ...d LF 0A F18 Reserved VT 0B Tab Field Forward Field Forward FF 0C Delete Delete CR 0D Field Exit New Line SO 0E Insert Insert SI 0F Clear Erase DLE 10 Error Reset Error Reset DC1 11 Home Reserved DC2 12 Print Print DC3 13 Back Space Back Space DC4 14 Back Tab Back Field NAK 15 F19 Reserved SYN 16 F1 PF1 ETB 17 F2 PF2 CAN 18 F3 PF3 EM 19 F4 PF4 SUB 1A F5 PF5 ESC 1B F6 PF6 FS 1C F7 PF7 GS 1D F8 PF8 R...

Page 125: ... N A N A BEL 07 New Line New Line New Line BS 08 N A N A N A HT 09 Tab Tab Tab LF 0A N A N A N A VT 0B Tab Tab Tab FF 0C N A N A Delete CR 0D New Line New Line New Line SO 0E N A N A Insert SI 0F Escape Escape Escape DLE 10 F11 F11 F11 DC1 11 Insert Insert Home DC2 12 F13 F13 Print DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Back Tab NAK 15 F12 F12 F12 SYN 16 F1 F1 F1 ETB 17 F...

Page 126: ...ke EOT 04 ALT break ENQ 05 CNTRL make ACK 06 CNTRL break BEL 07 RETURN BS 08 APPLE make HT 09 TAB LF 0A APPLE break VT 0B TAB FF 0C Del CR 0D RETURN SO 0E Ins Help SI 0F ESC DLE 10 F11 DC1 11 Home DC2 12 Prnt Scrn DC3 13 BACKSPACE DC4 14 LSHIFT TAB NAK 15 F12 SYN 16 F1 ETB 17 F2 CAN 18 F3 EM 19 F4 SUB 1A F5 ESC 1B F6 FS 1C F7 GS 1D F8 RS 1E F9 US 1F F10 DEL 7F BACKSPACE ...

Page 127: ...e removed when the unit is reset For instructions on how to reset your scanner refer to Reset Scanner page 8 1 Reset Scanner Scanning the following bar code clears temporary settings in the scanner and returns scanner to normal operation Scanning this bar code also causes the scanner to re link with the base Show Software Revision Scan the bar code below to output the current software revision uni...

Page 128: ...n the bar code below to determine the address of the base you are using Resetting the Standard Product Default Settings Current Application Work Group If you aren t sure what programming options are in your scanner or you ve changed some options and want the standard product default settings restored scan the Standard Product Default Settings Current Application Group bar code below The Menu Comma...

Page 129: ...figure the scanner for Visual Menu 2003 settings Refer to Visual Menu 2003 on page 9 1for additional information about Visual Menu 2003 After using Visual Menu scan the Reset Scanner bar code on page 8 1 Note If you have a unit capable of keyboard wedge mode scan the bar code below and the unit will communicate in RS 232 mode allowing it to work with Visual Menu 2003 To convert the scanner back to...

Page 130: ...8 4 IMAGETEAM 2020 5620 System Manual ...

Page 131: ... port and an RS 232 cable to connect the port to the device A power supply which plugs into the IT2020 5A is also required Note IT5620 IT2020 5A works only with Visual Menu 2003 version 4 2 or later Visual Menu 2003 Operations The Visual Menu 2003 program performs the following operations Displays all configuration data and saves the information to a file on your PC Configures the device to meet y...

Page 132: ...ystem Manual 6 Double click on the Visual Menu 2003 exe file Follow the screen prompts to install the Visual Menu 2003 program 7 To start Visual Menu 2003 from the Start Menu click on Programs Visual Menu 2003 Visual Menu 2003 ...

Page 133: ...indows that appear on the screen Menu Command Syntax Menu commands have the following syntax spaces have been used for clarity only Prefix Name Tag SubTag Data SubTag Data Tag SubTag Data Storage Prefix Three ASCII characters SYN M CR ASCII 22 77 13 Name To send information to the scanner with the base connected to host IT5620 The default factory setting for an IT5620 scanner is IT5620 This settin...

Page 134: ...ues for the setting s The de vice s response uses a dash to indicate a continuous range of values A pipe separates items in a list of non continuous val ues Name Field Usage Optional This command returns the query information from the scanner Tag Field Usage When a query is used in place of a Tag field the query applies to the entire set of commands available for the particular storage table indic...

Page 135: ...ubTag combination e g an entry for a minimum message length of 100 when the field will only accept 2 characters When responding the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks the period exclamation point comma or semicolon in the command Examples of Query Commands In the following examples a bracketed notation depicts a ...

Page 136: ...to 60 characters and the Default setting DFT has no value Trigger Commands You can activate and deactivate the scanner with serial trigger commands First the scanner must be put in Manual Serial Trigger Mode either by scanning the Manual Serial Trigger Mode bar code page 3 4 or by sending the Manual Serial Menu Command page 10 10 Once the scanner is in serial trigger mode the trigger is activated ...

Page 137: ... to Base on page 1 6 for additional information Note If your scanner is in multiple scanner mode and you scan either the current or all application group default bar code you will hear up to 30 seconds of beeping while all scanners are re linked from the base and the settings are defaulted to settings The default interface is keyboard wedge and the default scanner mode is single scanner locked lin...

Page 138: ...8 Imager Name Imager Name BT_NAM 1 9 Imager Report Imager Report RPT_SCN 1 10 Application Work Group Selections Group 0 GRPSEL0 1 11 Group 1 GRPSEL1 1 11 Group 2 GRPSEL2 1 11 Group 3 GRPSEL3 1 11 Group 4 GRPSEL4 1 11 Group 5 GRPSEL5 1 11 Group 6 GRPSEL6 1 11 Standard Product Defaults Current Application Work Group Default Current Work Group DEFALT 1 12 Standard Product Defaults All Application Wor...

Page 139: ...in KBDCTY7 2 4 Italy KBDCTY5 2 4 Norway KBDCTY9 2 4 Spain KBDCTY10 2 4 Switzerland KBDCTY6 2 4 Keyboard Style Regular KBDSTY0 2 5 Caps Lock KBDSTY1 2 5 Shift Lock KBDSTY2 2 5 Automatic Caps Lock KBDSTY6 2 5 Emulate External Keyboard KBDSTY5 2 6 Keyboard Modifiers Control ASCII Off KBDCAS0 2 6 Control ASCII On KBDCAS1 2 6 Turbo Mode Off KBDTMD0 2 6 Turbo Mode On KBDTMD1 2 6 Numeric Keypad Off KBDNP...

Page 140: ... Stop Parity Odd 232WRD6 2 9 7 Data 2 Stop Parity Even 232WRD4 2 9 7 Data 2 Stop Parity None 232WRD1 2 9 7 Data 2 Stop Parity Odd 232WRD7 2 9 8 Data 1 Stop Parity Even 232WRD5 2 9 8 Data 1 Stop Parity None 232WRD2 2 9 8 Data 1 Stop Parity Odd 232WRD8 2 9 RS 232 Handshaking RTS CTS Off 232CTS0 2 10 RTS CTS On 232CTS2 2 10 XON XOFF Off 232XON0 2 10 XON XOFF On 232XON1 2 10 ACK NAK Off 232ACK0 2 10 A...

Page 141: ...1 2 15 60 WNDBLK2 2 15 80 WNDBLK3 2 15 Wand Emulation Delay Between Blocks 5ms WNDDLY0 2 15 50ms WNDDLY1 2 15 150ms WNDDLY2 2 15 500ms WNDDLY3 2 15 Wand Emulation Overall Checksum Off WNDCHK0 2 16 On WNDCHK1 2 16 Output Selections Beeper Good Read Off BEPBEP0 3 1 On BEPBEP1 3 1 Beeper Volume Good Read Off BEPLVL0 3 1 Low BEPLVL1 3 1 Medium BEPLVL2 3 1 High BEPLVL3 3 1 Beeper Pitch Good Read Freque...

Page 142: ...LYGRD 3 3 Trigger Mode Manual Trigger TRGMOD0 3 4 Read Time Out 0 300 000 ms 300 000 TRGSTO 3 4 Scanner Power Time Out Timer 0 7200 seconds 3600 BT_LPT0 3 5 BT_LPT200 3 5 BT_LPT400 3 5 BT_LPT900 3 5 BT_LPT3600 3 5 BT_LPT7200 3 5 Automatic Trigger TRGMOD1 3 5 Presentation Mode TRGMOD3 3 5 Hands Free Time Out 0 300 000 seconds 5000 TRGPTO 3 6 Reread Delay Short 500 ms DLYRRD500 3 6 Medium 750 ms DLY...

Page 143: ...D0 3 12 Video Reverse On VIDREV1 3 12 Off VIDREV0 3 12 Prefix Suffix Selections Add CR Suffix to All Symbologies VSUFCR 4 3 Prefix Add Prefix PREBK2 4 3 Clear One Prefix PRECL2 4 3 Clear All Prefixes PRECA2 4 3 Suffix Add Suffix SUFBK2 4 4 Clear One Suffix SUFCL2 4 4 Clear All Suffixes SUFCA2 4 4 Function Code Transmit Enable RMVFNC0 4 4 Disable RMVFNC1 4 4 Intercharacter Delay DLYCHR 4 5 User Spe...

Page 144: ... All Symbologies On ALLENA1 6 1 Codabar Default All Codabar Settings CBRDFT 6 3 Codabar Off CBRENA0 6 3 On CBRENA1 6 3 Codabar Start Stop Char Don t Transmit CBRSSX0 6 3 Transmit CBRSSX1 6 3 Codabar Check Char No Check Char CBRCK20 6 4 Validate But Don t Transmit CBRCK21 6 4 Validate and Transmit CBRCK22 6 4 Codabar Concatenation Off CBRCCT0 6 4 On CBRCCT1 6 4 Require CBRCCT2 6 4 Codabar Message L...

Page 145: ...f 5 Default All Interleaved 2 of 5 Settings I25DFT 6 9 Interleaved 2 of 5 Off I25ENA0 6 9 On I25ENA1 6 9 Interleaved 2 of 5 Check Digit No Check Char I25CK20 6 10 Validate But Don t Transmit I25CK21 6 10 Validate and Transmit I25CK22 6 10 Interleaved 2 of 5 Message Length Minimum 2 80 4 I25MIN 6 10 Maximum 2 80 80 I25MAX 6 10 Code 93 Default All Code 93 Settings C93DFT 6 11 Code 93 Off C93ENA0 6 1...

Page 146: ...um 1 80 80 X25MAX 6 14 Code 11 Default All Code 11 Settings C11DFT 6 14 Code 11 Off C11ENA0 6 14 On C11ENA1 6 14 Code 11 Check Digits Required 1 Check Digit C11CK20 6 14 2 Check Digits C11CK21 6 14 Code 11 Message Length Minimum 1 80 4 C11MIN 6 15 Maximum 1 80 80 C11MAX 6 15 Code 128 Default All Code 128 Settings 128DFT 6 15 Code 128 Off 128ENA0 6 16 On 128ENA1 6 15 ISBT Concatenation On ISBENA1 6...

Page 147: ...8 On UPAENA1 6 18 UPC A Check Digit Off UPACKX0 6 18 On UPACKX1 6 18 UPC A Number System Off UPANSX0 6 19 On UPANSX1 6 19 UPC A 2 Digit Addenda Off UPAAD20 6 19 On UPAAD21 6 19 UPC A 5 Digit Addenda Off UPAAD50 6 19 On UPAAD51 6 19 UPC A Addenda Required Not Required UPAARQ0 6 19 Required UPAARQ1 6 19 UPC A Addenda Separator Off UPAADS0 6 20 On UPAADS1 6 20 UPC E Default All UPC E Settings UPEDFT ...

Page 148: ...EAN JAN 13 Off E13ENA0 6 23 On E13ENA1 6 23 EAN JAN 13 Check Digit Off E13CKX0 6 23 On E13CKX1 6 23 EAN JAN 13 2 Digit Addenda Off E13AD20 6 24 On E13AD21 6 24 EAN JAN 13 5 Digit Addenda Off E13AD50 6 24 On E13AD51 6 24 EAN JAN 13 Addenda Required Not Required E13ARQ0 6 24 Required E13ARQ1 6 24 EAN JAN 13 Addenda Separator Off E13ADS0 6 24 On E13ADS1 6 24 ISBN Translate Off E13ISB0 6 25 On E13ISB1...

Page 149: ... Don t Transmit MSICHK0 6 27 Validate Type 10 and Transmit MSICHK1 6 27 MSI Message Length Minimum 4 48 4 MSIMIN 6 28 Maximum 4 48 48 MSIMAX 6 28 Plessey Code Default All Plessey Settings PLSDFT 6 28 Plessey Code Off PLSENA0 6 28 On PLSENA1 6 28 Plessey Message Length Minimum 4 48 4 PLSMIN 6 28 Maximum 4 48 48 PLSMAX 6 28 RSS 14 Default All RSS 14 Settings RSSDFT 6 29 RSS 14 Off RSSENA0 6 29 On RS...

Page 150: ...de Default All Korea Post Code Settings KPCDFT 6 32 Korea Post Code Off KPCENA0 6 32 On KPCENA1 6 32 Korea Post Code Msg Length Minimum 2 80 4 KPCMIN 6 32 Maximum 2 80 48 KPCMAX 6 32 PosiCode Default All PosiCode Settings POSDFT 6 32 PosiCode Off POSENA0 6 33 On POSENA1 6 33 A and B On POSLIM0 6 33 A and B and Limited A On POSLIM1 6 33 A and B and Limited B On POSLIM2 6 33 PosiCode Msg Length Mini...

Page 151: ...ings 16KDFT 6 35 Code 16K Off 16KENA0 6 35 On 16KENA1 6 35 Code 16K Minimum 0 160 1 16KMIN 6 35 Maximum 0 160 160 16KMAX 6 35 Code 49 Default All Code 49 Settings C49DFT 6 35 Code 49 Off C49ENA0 6 36 On C49ENA1 6 36 Code 49 Minimum 1 81 1 C49MIN 6 36 Maximum 1 81 81 C49MAX 6 36 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 152: ...10 20 IMAGETEAM 2020 5620 System Manual ...

Page 153: ... 65 degrees Horizontal Velocity 2 inches 5 cm per second Scan Contrast 20 minimum Battery Lithium Ion 3 6 Volt 1600 mAHr minimum Battery Capacity Standby Heavy Usage 1 scan per second 20 hours 12 hours Storage 5 loss per month Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Battery Charge 41 F to 104 F 5 C to 40 C Storage 40 F to 140 F 40 C to 60 C Humidity Up to 95 non condensing Mechanica...

Page 154: ...00mA will not charge 9 Volt DC Barrel 100 750mA 12 volt Host 100 150mA Charge Rate 41 F to 104 F 5 C to 40 C 9 Volt DC Barrel external power Maximum 4 hours full charge for fully discharged battery Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Battery Charge 41 F to 104 F 5 C to 40 C Storage 40 F to 140 F 40 C to 60 C Humidity Up to 95 non condensing Mechanical Drop Operational after 50 d...

Page 155: ...inimum Far Field no ambient lighting 13 mil 100 UPC 1 in 2 5 cm 24 in 61 cm 7 5 mil Code 39 4 in 10 cm 14 in 36 cm 10 mil Code 39 2 in 5 cm 18 in 46 cm 13 mil Code 39 1 in 2 5 cm 24 in 61 cm 15 mil Code 39 1 in 2 5 cm 28 in 71 cm 20 mil Code 39 1 in 2 5 cm 36 in 91 cm 55 mil Code 39 2 5 in 7 cm 44 in 112 cm ...

Page 156: ... Cable Pinouts Keyboard Wedge 10 Pin RJ41 Modular Plug connects to the base 1 2 Cord shield 3 Tied to supply power 4 Supply ground 5 Terminal clock 6 Terminal data 7 Supply power input Refer to tables on page 11 2 8 Keyboard data 9 Keyboard clock 10 ...

Page 157: ...s to the base 1 2 Cord shield 3 Prog 1 Tied to supply power for primary cable 4 Supply ground 5 6 Bar code data output 7 Supply power input Refer to tables on page 11 2 8 9 10 Bar code data output Supply power input 9 Pin Type D Female connects to your terminal Supply ground Cord shield 1 2 3 4 5 6 7 8 9 ...

Page 158: ...Modular Plug connects to the base 1 2 Cord shield 3 Prog 1 Tied to supply power for primary cable 4 Supply ground 5 Receive data Serial data to scanner 6 Transmit data Serial data from scanner 7 Supply power input Refer to tables on page 11 2 8 Request to send data 9 Clear to send data 10 ...

Page 159: ...IMAGETEAM 2020 5620 System Manual 11 7 Standard Cable Pinouts USB 10 Pin Modular Plug connects to the base 1 2 Data 3 Tied to supply power 4 Supply ground 5 6 7 5 volt supply power input 8 9 10 Data ...

Page 160: ...11 8 IMAGETEAM 2020 5620 System Manual ...

Page 161: ...ent solution is used rinse with a clean lens tissue dampened with water only The base and scanner s housing may also be cleaned the same way Inspecting Cords and Connectors Inspect the base s interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector may interfere with scanner operation Contact your Hand Held Products distributor for information about c...

Page 162: ...g the IT5620 Battery 1 Remove the screw on the end cap 2 Remove the battery from the handle 3 Insert battery 4 Replace end cap and screw Troubleshooting Base Note Please visit the Services and Support section of our website www handheld com to check for the latest software for both the imager and the base If your base is not functioning properly review the following troubleshooting guidelines to t...

Page 163: ... to which the scanner connects Is the bar code displayed but not entered into the application The bar code is displayed on the host device correctly but you still have to press a key to enter it the Enter Return key or the Tab key for example You need to program a suffix Programming a suffix enables the scanner to output the bar code data plus the key you need such as CR to enter the data into you...

Page 164: ...scanner still can t read the sample bar codes scan All Symbologies on page 6 1 If you aren t sure what programming options have been set in the base or if you want the factory default settings restored scan Resetting the Standard Product Default Settings Current Application Work Group on page 10 5 Troubleshooting the Cordless System The scanner must be linked to the base for the system to work pro...

Page 165: ...ucts Corporate Offices Telephone 800 782 4263 Option 3 Fax 704 566 6015 E mail naservice handheld com America Latina Hand Held Products America Latina Teléfono 239 263 7600 Fax 239 263 9689 E mail laservice handheld com Brazil Hand Held Products Brazil Telephone 55 21 2176 0250 Fax 55 21 2176 0249 E mail suporte handheld com Europe Middle East and Africa Hand Held Products Europe Telephone 31 0 40...

Page 166: ...m Online Technical Assistance You can also access technical assistance online at www handheld com Limited Warranty Hand Held Products Inc Hand Held Products warrants its products to be free from defects in materials and workmanship and to conform to Hand Held Products published specifications applicable to the products purchased at the time of shipment This warranty does not cover any Hand Held Pr...

Page 167: ... TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT IN NO EVENT SHALL HAND HELD PRODUCTS BE LIABLE FOR INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES AND IN NO EVENT SHALL ANY LIABILITY OF HAND HELD PRODUCTS ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CONTRACT WARRANTY TORT OR OTHERWISE EXCEED THE ACTUAL AMOUNT PAID TO HAND HELD PRODUC...

Page 168: ...13 4 IMAGETEAM 2020 5620 System Manual ...

Page 169: ...ex ID China Post Q X0 51 Korea Post X0 3F Codabar a Fm 61 Matrix 2 of 5 m X0 6D Codablock F q Om 71 MSI g Mm 67 Code 11 h Hm 68 No Read 9C Code 16K o Km 6F Plessey Code n P0 6E Code 39 b Am 62 PosiCode W pm 57 Code 32 Pharma ceutical PARAF X0 3C Reduced Space Symbology RSS 14 RSS Limited RSS Expanded y em 79 Code 49 l Tm 6C Straight 2 of 5 IATA 2 bar start stop Straight 2 of 5 Industrial 3 bar sta...

Page 170: ...HT 169 29 233 49 l 297 69 i 10 0A LF 170 2A 234 4A J 298 6A j 11 0B VT 171 2B 235 4B K 299 6B k 12 0C FF 172 2C 236 4C L 300 6C l 13 0D CR 173 2D 237 4D M 301 6D m 14 0E SO 174 2E 238 4E N 302 6E n 15 0F SI 175 2F 239 4F O 303 6F o 16 10 DLE 176 30 0 240 50 P 304 70 p 17 11 DC1 177 31 1 241 51 Q 305 71 q 18 12 DC2 178 32 2 242 52 R 306 72 r 19 13 DC3 179 33 3 243 53 S 307 73 s 20 14 DC4 180 34 4 2...

Page 171: ...332 EC ì 141 8D 205 AD 269 CD Í 333 ED í 142 8E Ž 206 AE 270 CE Î 334 EE î 143 8F 207 AF 271 CF Ï 335 EF ï 144 90 208 B0 272 D0 Ð 336 F0 ð 145 91 209 B1 273 D1 Ñ 337 F1 ñ 146 92 210 B2 274 D2 Ò 338 F2 ò 147 93 211 B3 275 D3 Ó 339 F3 ó 148 94 212 B4 276 D4 Ô 340 F4 ô 149 95 213 B5 µ 277 D5 Õ 341 F5 õ 150 96 214 B6 278 D6 Ö 342 F6 ö 151 97 215 B7 279 D7 343 F7 152 98 216 B8 280 D8 Ø 344 F8 ø 153 99 ...

Page 172: ...option is available for Code 39 Code 93 and Code 128 Code Page Standard Description 1 CP ISO646 2 Default ISO 2022 Automatic National Replacement Characters 3 CP Binary 82 ISO 2022 11 Swe Swedish Replacement Characters 83 ISO 2022 69 Fra French Belgium Replacement Charac ters 81 ISO 2022 25 Fra French Belgium Replacement Charac ters 84 ISO 2022 11 Ger German Replacement Characters 85 ISO 2022 11 I...

Page 173: ......

Page 174: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 1234567890 Code 128 9 780330 290951 654 EAN 8 3210 5 456123 8 0 UPC E ...

Page 175: ...Sample Symbols Code 93 123456 9 Code 2 of 5 123456 Matrix 2 of 5 6543210 RSS 14 01 00123456789012 Code 39 Codabar BC321 A13579B ...

Page 176: ......

Page 177: ......

Page 178: ......

Page 179: ...rogramming Chart A C Save B Discard F E D Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save 0 2 6 1 7 5 4 3 8 9 ...

Page 180: ...Hand Held Products Inc 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 5620 SM Rev C 3 05 ...

Reviews: