background image

   

 

 
 
 
 
 
 
 
 
 

                                   

 

 

                                                                                   

 

                 

 

                         

                  

   

HM-LCD3 User Manual

 

 

 

HM-LCD3 eBike LCD Control Panel

 

 

 
 
 

 
 
 
 

HalloMotor.com

www.HalloMotor.com

Summary of Contents for HM-LCD3

Page 1: ...HM LCD3 User Manual HM LCD3 eBike LCD Control Panel HalloMotor com w w w H a l l o M o t o r c o m...

Page 2: ...iameters install icon 5 Physical installation icon 6 Function Overview 6 Display Content 7 Button Definition 7 Normal Operation 7 On Off 7 Display Interface 8 Display 1 8 Display 2 9 Display 3 10 Disp...

Page 3: ...e 20 P3 Power Assist Control Mode 21 P4 Handlebar Startup Mode 21 P5 Power Monitoring Mode 22 Exit P Parameter Setting 23 C Parameter Setting 23 C1 Power Assist Sensor and Parameter Selection Mode 23...

Page 4: ...nimum Voltage Adjustment Mode 33 C13 ABS brakes of the controller and parameters of anti charge control 34 C14 Power assist tuning parameters 35 Exit C Parameter Setting 36 Parameter Copy 36 User Sett...

Page 5: ...achieve the best match of the three as motor controller and meter to improve electronic control performance of the electric motor This manual covers installation operation parameter setting of the me...

Page 6: ...on the handlebars of the electric vehicle adjusting perspective In the case that the vehicle is power off the meter connectors are in plug connection to corresponding controller connectors Turn on th...

Page 7: ...aximum speed MXS and a single average speed AVS Trip distance display with displays of a single trip distance DST and total trip distance ODO Display of turned on handlebar Display of power assist sta...

Page 8: ...on the operating panel of button box which are icons of button alt text UP button alt text SW and alt text DOWN Button Box and Operating Panel Normal Operation On Off Hold button SW long the meter is...

Page 9: ...ower off mode the power consumption of the meter and controller is zero Display Interface Display 1 The meter is startup to enter display 1 Display 1 The followings are shown on display 1 Battery Capa...

Page 10: ...ature Backlights and Headlights Status Brake Status Cruise Function CRUISE Motor Running Temperature Display 2 In display 1 hold button SW shortly to enter display 2 Display 2 The followings are shown...

Page 11: ...ginal motor power is replaced by motor running temperature as is shown in Figure Display 3 In display 2 hold button SW shortly to enter display 3 Display 3 The followings are shown on display 3 Single...

Page 12: ...handlebar under normal operating of the meter the display interface shows the sign of turned on handlebar see the Figure below The sign will be off automatically after about five seconds Display of po...

Page 13: ...ower and gear 5 is for the highest power At every startup the meter will automatically restore gear this can also be configured as required by users when it was at last shut down When the power assist...

Page 14: ...the vehicle headlights the Controller should have headlights driving and output functions meter backlighting and vehicle lights power logo light hold button UP long again to turn off backlights and ve...

Page 15: ...Voltage shortage flashes Battery capacity indicator Motor Operating Power and Temperature Under the riding status of vehicle the real time running and output power can be known via the meter displays...

Page 16: ...display The temperature display value may be in deviation shortly after boot up and the display value will be gradually approaching the environment temperature within 10 minutes after boot up Single...

Page 17: ...e Error Code Definition 01 info Throttle Abnormality 03 info Motor Hall Signal Abnormality 04 info Torque sensor Signal Abnormality 05 info Axis speed sensor Abnormality only applied to torque sensor...

Page 18: ...face of maximum trip speed Under the setting maximum riding speed interface if there s no button operation on the meter for more than 1 minute and then the meter will automatically return to display 1...

Page 19: ...etting Metric and Imperial Units After finishing the wheel diameter setting enter into the metric imperial units setting interface and then the speed and mileage unit flash Hold button UP or button DO...

Page 20: ...eturn to display 1 meanwhile the current set parameters are saved Under each setting interface if there s no button operation on the meter for more than 1 minute and then the meter will automatically...

Page 21: ...arameter setting is finished and P2 parameter column flashes P2 parameter setting interface P2 is wheel speed pulse signal setting mode If wheel generated 1 pulse signal by a revolution P2 should be s...

Page 22: ...fter P2 parameter setting is finished and P3 parameter column flashes P3 parameter setting interface P3 is for power assist control mode when P3 parameter setting is1 power assist control mode is gear...

Page 23: ...ower monitoring mode when P5 setting is 0 the power monitoring is the real time voltage mode Namely it is the method to determine the battery capacity based on real time battery voltage When P5 equals...

Page 24: ...ting P5 parameter column stops flashing Within 1 minute after stopping flashing hold button UP and button DOWN for about 2 seconds to enter C parameter setting environment C1 Power Assist Sensor and P...

Page 25: ...erface after C1 parameter setting is finished C2 parameter column flashes C2 parameter setting interface C2 is motor phase classification coding mode It is served as identification parameter of differ...

Page 26: ...assist ratio is at gear 1 2 The meter is powered on and the power assist ratio is at gear 2 3 The meter is powered on and the power assist ratio is at gear 3 4 The meter is powered on and the power a...

Page 27: ...ist the handlebar speed limit is 6Km h after power assist handlebar is full speed Stop power assist return the handlebar speed limit is 6Km h 4 Handlebar gears is distinguished according to the displa...

Page 28: ...rent adjustment mode tiny adjustment of limit current value The default value is 10 setting range is 0 10 hold button UP or button DOWN shortly for selection C5 parameter definition table C5 value Max...

Page 29: ...arameter setting is finished C6 parameter column flashes C6 parameter setting interface C6 is the meter backlight brightness adjustment mode The default value is 3 and setting range is 1 5 hold button...

Page 30: ...finishing C7 parameter setting hold button SW shortly to save the current set values and enter C8 parameter setting interface C8 Motor Operating Temperature Display Mode Enter C8 parameter setting int...

Page 31: ...terface C9 Startup Password Setting Mode Enter C9 parameter setting interface after C8 parameter setting is finished C9 parameter column flashes C9 parameter setting interface C9 is meter power on pas...

Page 32: ...prier to be decoded After finishing C9 parameter setting hold button SW shortly to save the current set values and enter C10 parameter setting interface C10 Automatically Restore Default Setting Mode...

Page 33: ...ameter column flashes C11 parameter setting interface C11 is meter attribute selection mode The setting range is 0 2 hold button UP or button DOWN shortly for selection C11 parameter definition table...

Page 34: ...face after C11 parameter setting is finished C12 parameter column flashes C12 parameter setting interface C12 is controller minimum operating voltage adjustment mode tiny adjustment of voltage shortag...

Page 35: ...oltage voltage shortage value when setting is 5 the default value plus 0 5V when setting is 4 the default value minus 0 5Vand so on After finishing C12 parameter setting hold button SW shortly to save...

Page 36: ...er the greater damage to the motor shaft accordingly After finishing the parameter setting of C13 press SW button for short to enter C14 parameter setting interface C14 Power assist tuning parameters...

Page 37: ...meters would be saved Under each parameter setting interface if there s no button operation on the meter for more than 1 minute and then the meter will automatically return to display 1 and the origin...

Page 38: ...er subject to be copied will display as follow Interface of finishing parameter copy Please note Both C9 power on password and C11 meter attributes can t be copied Besides LCD3 meter can only copy par...

Page 39: ...CD3 Product User Manual 38 automatically restore factory setting mode approach when adjusting it Version Information HM LCD3_V3 0 Released on April 12 2015 HalloMotor Team All rights reserved w w w H...

Reviews: