background image

N o .

*

Please read this manual carefully before using
Please keep this manual for future use

AB212BCBAA

0 0 1 0 5 7 1 5 7 0

 

Haier Network Air Conditioner

Two by One Room Air Conditioner

CONTENTS

Before Use

Name of Parts

************* 3-4

Safety Precautions

**********  5-6

Operation Instruction

Fan Operation

************** 7

Auto, Cooling, Dehumidifying,
Heating operation

************ 8

Timer On/Off Function

********  11

Timer On-Off Function

 ******** 12

Maintenance
Maintenance 

*************14-18

Usersí Attention

************ 13

Installation of Indoor Unit

Installation Instruction

******  21

22

Installation Procedure

 ******  23*36

*

Operation Points

***********  1-2

Troubleshooting

*********** 19-20

Sleep Function

************* 10

Swing Operation

************  9

Summary of Contents for 10571570

Page 1: ... Name of Parts 3 4 Safety Precautions 5 6 Operation Instruction Fan Operation 7 Auto Cooling Dehumidifying Heating operation 8 Timer On Off Function 11 Timer On Off Function 12 Maintenance Maintenance 14 18 Usersí Attention 13 Installation of Indoor Unit Installation Instruction 21 22 Installation Procedure 23 36 Operation Points 1 2 Troubleshooting 19 20 Sleep Function 10 Swing Operation 9 ...

Page 2: ...d with the ceiling exquisite and beautiful 4 Powerful circular air volume quick temperature adjustment 5 This air conditioner has POWER FAILURE RESUME FUNCTION 6 Anti bacteria mildew resistant air filter fresher air creates more healthy This unit has the function of far distance monitoring Through the telephone network it can be effectively controlled in any other far distance place Only after equ...

Page 3: ...computer management or other place monitoring can be achieved to the air conditioner If start the unit immediately only after it is turned off the compressor will start after 3 minutes have elapsed to protect the compressor 3 minute protection function Change of fan speed In COOLING mode the air sending is set at AUTO when the indoor temperature is near the set temperature the fan speed will lower...

Page 4: ...tual condition After setting power failure resume function if there is a sudden power failure during unit operation when power on for again the unit will resume the previous state Setting method when the wire controller is in ON state except for TIMER and FAN mode press the SLEEP button for 10 times in 5 seconds after the buzzer sounds 4 times the unit will change to POWER FAILURE RESUME function ...

Page 5: ...Connection pipes and electric wire Drain hose Louver Louver Air filter inside of air outlet inside of air inlet grille Air inlet grille Air outlet Name of Parts Indoor Unit Wire Controller AUTO 3 ...

Page 6: ...o confirm the time of timer and clock 15 Working mode display 21 Clock button Used to calibrate the time of timer and clock 16 Electric heating display Used to set working mode Auto Cooling Dehumidifying Heating Fan 18 Fan speed button Used to set fan speed Low Fan Med Fan High Fan Auto 20 Temperature Setting button 29 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28 AUTO 10 He...

Page 7: ... oxygen even if refrigerant leaks When have to dismantle and reinstall the air conditioner please ask the after sales service worker to perform the work Improper installation may cause water leakage electric shock or fire Cut off power Safety Precautions The following lists four kinds of safety precaution items and suggestions Warning Improper use may cause death or serious injury Those contents m...

Page 8: ...ure or other articles alike Do not install the air conditioner in a place where the inflammable gas maybe exists The inflammable gas around the air conditioner may cause fire accident The Creepage breaker should be equipped If not equipped with Creepage breaker it may cause Creepage When using indoor smoky type pesticide do not use air conditioner Otherwise it may cause the chemicals accumulate in...

Page 9: ...ow the previous working state except for Timer Sleep Swing mode the operation indicator light on the wire controller will light up 2 Choose of working mode Press MODE button each press the working mode will change as the following sequence choose FAN operation Adjusting FAN SPEED Press the FAN SPEED button to change fan speed 3 4 Turn off the unit Press the ON OFF button to turn off the unit The w...

Page 10: ...the set temperature will decrease 1 degree Set the desired temperature Press the TEMP SET button Adjusting FAN SPEED Press the FAN SPEED button for each press the fan speed will change as the following sequence Choose the desired fan speed In Heating operation after start the unit the air conditioner will sending warm air a moment later to prevent the cold air blowing out In Dehumidifying when the...

Page 11: ...HEATING it is better to be downward Always use the SWING button of the wire controller to adjust the louver If adjust the louver manually it may damage the louver During COOLING and DEHUMIDIFYING do not make the louver downwards for a long time Because the vapor around the air outlet grille may be condensed and may have drop of water When the infant children ages and the patients use the air condi...

Page 12: ...lower than set temperature to prevent you from feeling uncomfortable during sleep 3 In AUTO operation The air conditioner will perform the relative SLEEP operation according to automatically chosen operation mode 4 In FAN operation Cannot use SLEEP function Operation modes 1 In COOLING DEHUMIDIFYING operation 1 hour later in SLEEP operation the temperature will increase 1 from the set temperature ...

Page 13: ...ases 10 minutes If depress the button the time will decrease rapidly 3 Set time Press the time adjusting button This LCD will show the time set the time can be adjusted within 24h AM stands for morning PM stands for afternoon 4 Confirm the time After calibration of the clock press SET button to confirm time The time displayed is at x o clock x minutes the unit will be turned on TIMER ON or turned ...

Page 14: ...es the unit will be turned off ON OFF 5 6 2 Set of TIMER mode Press the TIMER button to change the TIMER mode each press the TIMER mode will change as the following sequence 1 Turn on the unit After turning on the unit set the desired working mode The LCD of the wire controller will show working mode except for Timer Sleep Swing Each press the set time increases 10 minutes If depress the button th...

Page 15: ... the unit may consume power In order to protect the unit before using the air conditioner again turning on the power at least 12 hours in advance The windows should be hung with curtains or blinds Do not let the sun shine directly shine in the room do not let the outdoor air enter room The articles must keep dry cannot be put under the indoor unit When the humidity is over 80 or the drainage outle...

Page 16: ...ce cut off the power first Use stable stand support Please pay high attention when cleaning the unit Daily maintenance Clean the air filter Instructions When not for cleaning do not dismantle the air filter otherwise it may cause trouble When the air conditioner is used in a dusty environment the air filter should be cleaned more often generally once every two weeks 1 Open air inlet grille Pull th...

Page 17: ... may be burnt Use cleaner or water to clean to remove dust A Use cleaner to remove dust B When the dust is too much use soft brush and neutral detergent C Throw the water off then put it in the shadow for airing 4 Install air filter 1 Put the air filter into those extruding parts at the top of the air inlet grille 2 Draw the handles at the back of the air inlet grille inwards to fix the air filter...

Page 18: ... use the hot water over 50 to clean to avoid discoloration or deformation Use soft brush water and neutral detergent to clean then throw the water off Instruction When there is too much dust Use ventilation fan or directly spray the detergent special for kitchen ware on the air inlet grille 10 minutes later use water to clean 5 Install air inlet grille 6 Install the air filter 7 Close air inlet gr...

Page 19: ...ed as the following described for cleaning Dismantle and install louver Notice When use water to clean the louver do not clean it to hard otherwise the fuzz on the surface maybe fall off 1 Fix the louver at the lowest position 2 Dismantle louver Referring to SWING Loosen the screws at the two ends of the louver 3 Install louver Slightly rotate the louver the extruding edges at the ends of the air ...

Page 20: ...casing After cleaning the air filter it must be reinstalled 3 Turn on the power After using season 1 In a sunny day perform half a day Fan operation to make the inner of the unit dry 2 Cut off the power If do not cut off power the unit will consume power Power cutoff can save power 3 Cleaning the air filter or air inlet and casing After cleaning the air filter it must be reinstalled For the detail...

Page 21: ...is generated when the refrigerant stops flow or changes flow In operation or after operation there is a continuous Si Si sound In operation or after operation a GaZi sound is generated Because of the temperature change It is caused by the hot expansion and cold shrink of the resin parts After a long time out of use the unit is started The dust in the indoor unit assembly is blown out In operation ...

Page 22: ...g the curtain or blinds before windows Too much people in room Too many heat sources in room After checking the above items and treating the air conditioner it still cannot normally work or find the following troubles occur please stop the unit and cut off power then contact the after sales service worker The fuse and creepage breaker are often blown out In Cooling or Dehumidifying operation there...

Page 23: ...ation the electric box cover and the external panel shall not nip the wire Improper installation will cause heating and fire etc accidents When setting or moving the air conditioner do not let the air and things alike get into the refrigeration system except the specified refrigerant R22 If air and other things enter abnormal high pressure will occur which easily cause break and body injuries etc ...

Page 24: ...ned standard accessories please check them by yourself As the following figure shown 1 Screwdriver 2 Steel saw 3 60 70mm diameter drill 4 Spanner diameter 17 27mm 5 Spanner 14 17 19 27mm 6 Pipe cutter 7 Pipe flarer 8 Knife 9 Pincers 10 Leakage detector soap water No Shape name Amount 1 No Shape name Amount 6 Little wire clamp Buckle 1 Wire controller signal wire AUTO SET ROOM MODE FAN SWING TEMP H...

Page 25: ...mitted limit referring to outdoor unit installation part The indoor unit outdoor unit electric wire and connection wire is at least 1m away from television and radio This is to avoid the image disturbance and noise caused by the above mentioned home appliance Even if 1m away if the electromagnetic wave is too strong it can also cause noise 2 The height of ceiling The indoor unit can install on the...

Page 26: ...ling before hanging the unit put the refrigerant pipe drain hose indoor unit connection wire and wire control wire in the position of the connection pipe and connection wire Confirm the dimension of indoor unit by using the attached installation paper panel to make the indoor unit accord with the dimension of ceiling opening and its position Use the attached 4 M5x12 screws to fix the installation ...

Page 27: ...hole plug or in hole screw Angle steel for support Hoisting screw Suspending bolt 25 M10 screw Attached washer Screw cap underside Hoisting screw 135mm Screw cap upside The suspending part of the unit Ceiling Adjust the position of screw cap underside to make the gap between the attached washer underside and the ceiling is 135mm Tighten the screw cap of the hoisting screw and suspend them on the T...

Page 28: ... the following figure shown Only use seal cushion to bind the joint between gas pipe and the insulation parts Specification of pipe mm Torque Dimension of cone A mm Cone 9 52 15 88 12 0 12 4 18 6 19 0 3270 3990 N cm 333 407 kgf cm 6180 7450 N cm 630 770 kgf cm 6 Installation of drain hose 1 Install the drain hose The diameter of the drain hose should be larger than or equal to the diameter of conn...

Page 29: ...gree a drainage enhancing hose should be equipped In order not to let the drain hose bend a 1 1 5m distance should be kept between suspending frame Below 750 Below 75 Drain hose accessory Drain hose accessory Wire clamp accessory Within 300mm 1 1 5m Drainage enhancing pipe Hoisting foot Below 530 Below 750 220 Installation procedure Install indoor unit 1m 1 5m Thermal insulation material customer ...

Page 30: ...tic watering pot the pipe should be about 100mm long discharge through the air discharging hole Charge through the checking hole Checking hole Maintenance cover Terminals block of the power The PC board of the indoor unit Terminals block of the power Electric box cover 7 Electric circuit All the provided parts material and electric work should be complied with the local regulation Must use cooper ...

Page 31: ... Bind the seal cushion on the wire it must be bound tight to avoid dew forming After proper connection reinstall the electric box cover 1 This part must be sealed to prevent water from entering Instruction Use seal cushion to bind tight not leaving any gap Seal cushion little size bind the wire inside outside Attached with seal cushion Power terminal block Wire clamp A Rubber lining Electric box c...

Page 32: ...to the terminals on the indoor PC panel A B C D respectively Note When connecting wire please keep a certain distance between signal wire and electric wire over 10mm Dimension of signal wire Type of wire Shield wire 4 cords Dimension The connection between indoor unit and wire controller and indoor unit and outdoor unit should use shield wire And the two ends of the shield wire should be grounded ...

Page 33: ...off the adhesive tape to fixing the air filter on the back of the air inlet grille referring to Figure 2 2 The installation of the decorative panel on the indoor unit As Figure 4 shown make the position of the louver motor of the decorative panel and the position of nozzle of the indoor unit face to face then install the decorative panel on the indoor unit 2 Dismantle the corner cover Tear off the...

Page 34: ... indoor unit Temporarily hang the other 2 hoisting rings on the hoisting ring fixing pieces at the side of the indoor unit be careful not to stick to wire of the louver motor into the sealing material Screw all the 4 hexagon screws under the hoisting ring into about 5mm the decorative panel will rise Twist in the direction as Figure 4 shown adjust the decorative panel to make it totallycover the c...

Page 35: ...o the the preparation of decorative panel part 2 Install the corner cover on the corner As Figure 8 shown tie the rope of the corner cover on the cleat of the decorative panel Install the corner cover on the decorative panel referring to Figure 9 different from the actual condition Figure 7 The indication diagram of circuit Side of indoor unit 33 Installation procedure Install the decorative panel...

Page 36: ... Discharging of pipe For details please refer to the pipe installation part in the manual of outdoor unit 5 Leakage detection Use leakage detector or soap water to check if the connected part of the connection pipe and the valve cap leak For the specific max length and the max fall of connection pipe please refer to the manual of outdoor unit In order to guarantee the efficiency the pipe should be...

Page 37: ...rbicular terminal Wiring method 1 The wiring method of orbicular terminal For the connection wire which end is orbicular terminal its wiring method is as the right figure shown Dismantle the screw and put it through the ring at the end of the connection wire then connect it to the terminal block and tighten the screw L N 1 2 3 Power supply 1PH 220V 50Hz Outdoor terminal block Indoor terminal block...

Page 38: ...ould be installed The grounding wire and null wire of receptacle should be strictly separated It is incorrect to connect the null wire with grounding wire The connection method of power cord is Y connection If the power cable is damaged in order to avoid danger it must be replaced by the manufacturer or its specified repair center of the same qualified worker 2 Cut and flaring method Use pipe cutt...

Reviews: