background image

Installation and operating manual

Pellet stove

Installation and operating manual

Pellet stove

GB

0541908001409a

Pellet stove

Nameplate:

Summary of Contents for HSP 8 CATANIA-II-RLU

Page 1: ...Installation and operating manual Pellet stove Installation and operating manual Pellet stove GB 0541908001409a Pellet stove Nameplate ...

Page 2: ...ment sheet is part of these operating instructions Notes in the text Of utmost importance there are the notes entitled WARNING The notes entitled WARNING advise you on serious danger of damage to the heating device or of an injury The note entitled Notice advises you on possible damage to your heating device The note itself calls your attention to the information important for the operation of you...

Page 3: ...l operator console functions 10 8 1 Backlighting 10 8 2 Energy saving mode Actual room temperature display 10 8 3 Button lock child safety device 11 9 Functions in the main menu 11 9 1 Main menu Select functions 11 9 1 1 Operating mode Weekly prog settings 12 9 1 2 Setting the language 13 9 1 3 Setting the time and date 13 9 1 4 Heating curve 13 9 1 5 ECO Mode 14 9 1 6 Power Stage Blower optional ...

Page 4: ... 13 Cleaning and maintenance work see Appliance sheet 3 4 18 14 Faults causes correction 18 14 1 Fault error code Fxxx 18 15 General information faults 21 16 Warranty 21 17 Replacement part orders Service enquiries Complaints 22 ...

Page 5: ...e combustion air opening provided must not be closed throttled constricted covered or shut off On stoves with an outdoor air connection the opening must not be shut or closed during operation This appliance can be used by children form 8 years and above and people with reduced physical sensory or mental capabilities if they have been given supervision and instruction concerning the use of the appl...

Page 6: ...ey must be made of stainless steel or ceramics glazed inside in order to be suitable for wet operation and cannot be soaked with soot It is necessary due to the low temperature of the fumes your pellet stove has WARNING Prior to the installation it is always necessary to calculate the chimney according to the standard WARNING The minimum diameter of a chimney stack must be Ø 100 mm CAUTION Please ...

Page 7: ... be securely fitted on the flue gas spigot The flue gas tube must not be installed with a drop to the chimney It is also essential to ensure that the flue tube does not stick out into the open cross section of the chimney which would interfere with the flue gases rising and prevent the optimal cleaning of the chimney The use of wall lagging is recommended for the insertion into the chimney Longer ...

Page 8: ...ctive length of the chimney C Inlet of outside air D T shaped block with plug for discharge of condensate 5 Installation CAUTION For comfortable maintenance and service are following distances recommended at the sides minimum 50 cm at the back minimum 25 cm ...

Page 9: ... the sides and in the direction of radiation forwards must be maintained according to the nameplate WARNING Floor protection In case of flammable or temperature sensitive floor coverings the appliance must be placed on a non flammable base see drawing Figure 2 Recommendation for floor protection A 30 cm at the front B 10 cm at the sides C up to the back wall WARNING It is forbidden to put down or ...

Page 10: ...tilated area basement WARNING It is not recommended to feed the cold air into the room from outside via a direct duct as this can lead to the build up of condensation In order to guarantee a sufficient supply of air the duct should not be longer than approx 3 m and not have too many bends If the duct leads outside it must end with a 90 bend facing down or a wind protection device see Figure 3 Figu...

Page 11: ...reased contamination of the burner and inspection window 6 Operator console functions 6 1 Buttons 6 1 1 Symbols on the display 10 34 Symbol Stove is WLAN capable Target room temperature Actual room temperature Operating status ON OFF menu Function of the buttons 7 Operating the pellet stove 7 1 Suitable fuels Pellets with 6mm diameter ...

Page 12: ...ove any stickers Remove all accessories from the pellet tank and the combustion chamber Check whether the combustion chamber cladding see appliance sheet is attached to its fastenings This could have slipped out of its position as a result of the transportation or installation of the stove Check that the burner fits perfectly in its mounting Close the combustion chamber door Fill the storage conta...

Page 13: ...equired language is selected with the Plus or Minus but tons and confirmed with OK language deutsch englisch OK 7 3 2 3 Welcome page 10 34 28 C 23 C off ON OFF menu 7 3 2 4 Setting Target room temperature 10 34 Procedure The Target room temperature is set with the Plus or Minus buttons The Target room temperature can be changed at any time as often as you want during operation with the Plus or Min...

Page 14: ...void inhaling directly Note If the start zone could not be successfully completed i e no flame generation or the required temperature could not be reached at the flue gas thermosensor then a safety shutdown is initiated and an error message generated Error 2 Date and time Before starting again empty the burner and replace it 8 Additional operator console functions 8 1 Backlighting The backlighting...

Page 15: ...n menu Select functions main menu Prerequisite Welcome page is displayed The Main menu page appears by pressing the OK button This menu is shown as a scroll down menu Procedure The functions can be selected with the Plus or Minus buttons The function is chosen by pressing the OK button oper mode language english date time heating curve 2 OK The following functions are found in the main menu Oper m...

Page 16: ... buttons The shut down time on the respective week day can be programmed by pressing the right hand arrow button The Target room temperature is selected by pressing the right hand arrow button again This procedure can be used to set 3 heating zones for each day with the respective room temperature Adjust the temperature in the room Week program symbol active 10 34 To exit the function press the On...

Page 17: ...n fr 15 09 2018 14 39 28 change To exit the function press the On Off button Note Summer and winter time are not automatically detected 9 1 4 Heating curve main menu h003 Setting range of the heating curve from 1 to 4 Factory setting 2 The value to be set is based on the size of the room being heated Guide values Room size 20 m Wert 1 Room 25 m Wert 2 heating curve set factor 2 2 OK Room 30 m Wert...

Page 18: ...menu Procedure The required line can be selected with the Plus or Minus buttons Press OK button on the right to switch on The screw conveyor then turns thus feeding the pellets As soon as the pellets move into the burner via the chute the feed process is stopped by pressing the OK button manual filling pulling in motor Off On Note Filling manually is used for the first use and when the pellet tank...

Page 19: ... of various test laboratories In this menu the partial load nominal load is tested according to EN 14785 standard Procedure Use the Plus or Minus keys to enter the required code accese code OK The code is as follows 1854 Pressing the OK button saves the setting The test setting partial load or nominal load is then selected Pressing the OK button activates the START of the respective test setting T...

Page 20: ...s takes approx 2 minutes 10 4 Cooling down If the set Target room temperature is reached or the ON OFF button is pressed then the operating status switches to cooling down The cooling down phase is restricted by timing control duration about 15 minutes After the end of the Cooling down operating status the appliance switches to standby operating status or OFF 10 5 ECO Mode ECO Mode means continuou...

Page 21: ...C F018 ON OFF con Note Otherwise please read the information under Faults causes correction 10 10 OFF 11 Overheating protection A safety temperature limiter STL automatically switches the stove off if it overheats The error F001 is shown on the console display under operating status In this case the appliance must be inspected by a qualified technician 12 Power cut The control unit has a backup ba...

Page 22: ...r not lying flush E Flame temperature sensor defective F Downpipe screw conveyor blocked G Screw motor defective A Clean burner B Clean burner fill pellet tank C Ignition defective contact service department D Clean burner position burner correctly E Flame temperature sensor defective contact service department F Clean the intake on the screw conveyor housing with a vacuum cleaner clean burner G S...

Page 23: ... defective A Contact service department F015 A Induced draught fan defective B Power supply to the fan motor interrupted A Contact service department B Check cable contact service department F018 A Power cut A Clean burner Clear error 018 F021 A Burner dirty B Pellet tank empty C Downpipe screw conveyor blocked D Room too airtight required combustion air cannot flow into the room E Flue gas temper...

Page 24: ...Position burner correctly C Check seal on door F028 A Burner combustion chamber dirty B Flame temperature sensor at bottom defective A Clean burner B Contact service department F033 A No WLAN connection B WLAN code is incorrect C No IP address received A Check WLAN reception B Check WLAN code C Check DHCP settings on the router F034 A No internet connection available A Check internet connection F0...

Page 25: ...our appliance within the warranty period HAAS SOHN will correct repair this defect in the shortest possible time or optionally replace the defective item Cancellation of the contract a reduction in price is excluded in so far as this does not conflict with the statutory regulations Only replacement parts that are expressly authorised or offered by the manufacturer may be used Replacement parts tha...

Page 26: ... can be dealt with quickly the following details from the nameplate are essential Exact type designation version of the model Manufacturer s number The nameplate is located on the back of the stove and on the front page of the operating instructions Please also take note of the technical drawings and tables on the appliance sheet where you will find the right designation of the replacement part re...

Page 27: ......

Page 28: ...All documents such as operating instructions appliance sheet test reports etc and contact details can also be found under www haassohn com ...

Reviews: