MPPT30-2L

Unit 2, 110 Station Road, Seven Hills ,NSW,  2147, Australia

1700W Solar Battery Charger 

Maximum Power Point Tracker

Operating Instructions

Please read these instructions before use

MPPT30-2L-R3

This revolutionary maximum power point tracker solar charger was designed using the 

technology that won GSL Electronics the prestigious EDN Innovation Awards 08’ and 09’ 

and the Greentech Consensus Awards 09’. A simple, compact and low cost alternative. 

Ideal for charging batteries from new low cost and high efficiency panels. 

The MPPT30-2L is designed to automatically charge 12V, 24V and 48V Lithium Iron Phosphate 

batteries from silicon based pv panels such as monocrystalline, polycrystalline and thin film. It 
has a built in Load Over Voltage switch configurable as a Remote Load Control or a Dawn to 

Dusk Switch. It can be connected to the MCM for remote control and full system parameter log-
ging and display.

PATENT APPLIED FOR - 2010901565

Summary of Contents for MPPT30-2L

Page 1: ...8 and 09 and the Greentech Consensus Awards 09 A simple compact and low cost alternative Ideal for charging batteries from new low cost and high efficiency panels The MPPT30 2L is designed to automatically charge 12V 24V and 48V Lithium Iron Phosphate batteries from silicon based pv panels such as monocrystalline polycrystalline and thin film It has a built in Load Over Voltage switch configurable...

Page 2: ...iency typical 96 Input voltage 16V to 95V Saturation Voltage Default 14 6V 29 2V 58 4V Long Life Option 14 3V 28 6V 57 2V High Capacity Option 14 8V 29 6V 59 2V Maintenance Voltage 14 1V 28 2V 56 4V Output power 1700W 30A MAX Quiescent current 0 05A Thermal protection Multilevel Type Dimensions mm 260 X 145 X 67mm Indications LED display OUTPUT STATUS MPPT30 2L General Information Green LED On Bat...

Page 3: ...ltage Disconnect Figure 2 This option protects the Load from receiving a High Voltage The MPPT voltage goes over 1V above its maximum programed value This protects the load from overvoltage spikes such as disconnection of the battery or faults with in the system Most LiFePo4 are fitted with over voltage disconnects from their onboard charge controllers and are already protected against Over Voltag...

Page 4: ...s are loads which can be disconnected to ensure maximum on time for critical loads as well as to extend the life expectancy and reliability of the system The non critical load can be set up as Dawn to Dusk loads via MCM Wiring with MCM option Connecting the optional MCM to the MPPT will allow various system parameter display output voltage and alarm settings and enable the programmable dawn to dus...

Page 5: ... 42 32 63 48 84 64 42 32 84 64 Grid Connect Panel size no cells in grid 1x18 Cell Grid 10 8 1x48 Cell Grid 28 23 2x48 Cell Grid 56 46 3x48 Cell Grid 84 69 1x52 Cell Grid 31 25 2x52 Cell Grid 62 50 3x52 Cell Grid 93 75 1x54 Cell Grid 32 26 2x54 Cell Grid 64 52 3x54 Cell Grid 96 78 1x60 Cell Grid 36 29 2x60 Cell Grid 72 58 1x72 Cell Grid 44 36 2x72 Cell Grid 88 72 1x96cgsp 65 55 For optimal performa...

Page 6: ...ront panel screws and the front panel and slide out cover see Figure 4 3 Locate connector J4 By default this will be Jumperless Nominal Setting see Figure 4 4 Shift link on J4 to desired battery setting High Capacity see Figure 5 Long Life See Figure 6 5 Slide back cover and fit in front panel carefully ensuring led is still visible through the faceplate and screw back the 7 mounting screws The ab...

Page 7: ...cal application which can be used for higher loads or longer run times or cutting PV system cost 2 Suitable for lower cost non battery type PV since the MPPT can efficiently charge the batteries from relatively high voltage say 12V batteries from 40V MPP panels 3 Less interference and more accurate voltages during saturation and maintenance Q What happens at low PV currents The MPPT will outperfor...

Page 8: ...V 1600W panel the MPPT30 will supply a daily load of 400W for about 10 hours Q Is interference possible and If so what do I do GSL s MPPTs produce far less interference than a conventional solar regulator during the absorption and float stages that is during most of its operating time and it is designed to comply with local and international EMI standards however some interference is still possibl...