background image

 

H53.0.X1.6C-07 

GHM 

Messtechnik GmbH • Standort Greisinger  

Hans-Sachs-

Str. 26 • D-93128 Regenstauf 

 +49 (0) 9402 / 9383-0  

 +49 (0) 9402 / 9383-33   

 

[email protected]

 

 
 

 

 

  Hygro-/Thermometer

 

 

 

 

Operating Manual

 

GFTH 95

 

 

 

WEEE-Reg.-No. DE93889386 

Summary of Contents for GFTH 95

Page 1: ... X1 6C 07 GHM Messtechnik GmbH Standort Greisinger Hans Sachs Str 26 D 93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Hygro Thermometer Operating Manual GFTH 95 WEEE Reg No DE93889386 ...

Page 2: ...2 SAFETY SIGNS AND SYMBOLS 3 2 3 SAFETY GUIDELINES 3 3 PRODUCT SPECIFICATION 4 3 1 SCOPE OF SUPPLY 4 3 2 OPERATION AND MAINTENANCE ADVICE 4 4 NOTES FOR DEVICE FUNCTIONS 5 4 1 CHOICE OF MEASURING UNIT 5 5 SYSTEM MESSAGES 5 6 SPECIFICATION 5 7 RESHIPMENT AND DISPOSAL 6 7 1 RESHIPMENT 6 7 2 DISPOSAL INSTRUCTIONS 6 ...

Page 3: ...the followings signs DANGER Caution This symbol warns of imminent danger death serious injuries and significant damage to property at non observance Attention This symbol warns of possible dangers or dangerous situa tions which can provoke damage to the device or environment at non observance Note This symbol point out processes which can indirectly influence operation or provoke unforeseen reacti...

Page 4: ...ruction of the sensors supporting material glass or ceramics In the sensor area there is ESD sensitive Never touch or hold sensor head In order to guarantee accurate measurements the device has to be adjusted to ambient temperature If necessary wait for the temperature of the device to adjust to the ambient temperature If this is not possible please proceed as follows Move device around while hold...

Page 5: ... 1 C same as Pt1000 1 3 DIN at nominal temperature 25 C humidity 3 RH range 30 80 RH Measuring probe temperature Pt1000 humidity capacitive polymer humidity sensor Response time T90 15 sec Display approx 13 mm high 3 digit LCD display Operation elements Slide switch for selection of measuring range Nominal temperature 25 C Operating conditions electronics 20 70 C 0 80 RH non condensing sensors 20 ...

Page 6: ...equate transport package for reshipment especially for fully functional devices Please make sure that the device is protected in the package by enough packing materials 7 2 Disposal instructions Batteries must not be disposed in the regular domestic waste but at the designated collecting points The device must not be disposed in the unsorted municipal waste Send the device directly to us sufficien...

Reviews: