© 2022 greenfan® inc. 

 

 

greenfan® 

 bipolar ionizer 

 

Model 1600-01 

 

INSTALLATION, OPERATION, AND  

MAINTENANCE INSTRUCTIONS

 

 

Intertek® Verified 

Zero Ozone  

Meets UL 2998 

CARB Certified 

Certified to 

CSA C22.2 #187 

Conforms to UL 867 

 

 

LAB TESTED

 

 

 

US Patent 11173226 and pending patents 

www.greenfan.co/bbi

_

manual

Summary of Contents for 1600-01

Page 1: ...odel 1600 01 INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS Intertek Verified Zero Ozone Meets UL 2998 CARB Certified Certified to CSA C22 2 187 Conforms to UL 867 LAB TESTED US Patent 11173226 a...

Page 2: ...Fan Verification of Proper Operation 7 5 0 AIR PURIFIER INSTALLATION 7 5 1 Air Purifier Mechanical Installation 7 5 2 Air Purifier Electrical Installation 7 5 3 Air Purifier Verification of Proper Ope...

Page 3: ...e Weighted Average TWA ozone for this product is 0 0 parts per million by volume ppmv when tested in a 30 m3 chamber The product is CARB certified and meets the Intertek Sustainability Verified Zero O...

Page 4: ...lar ionizer NOTICE The greenfan bipolar ionizer should only be installed and used as directed in this installation manual or the 2 page tri fold manual supplied with the product Please read the entire...

Page 5: ...For air purifiers or ventilation fans disconnect power or unplug power cord before installation All field wiring must be in accordance with the National Electrical Code NEC or National Fire Protection...

Page 6: ...polar ionizer installation at fan inlet of an HVAC system f Install bipolar ionizer on metal shroud and with at least one inch clearance between electrodes and metal surfaces Make sure screws do not i...

Page 7: ...VAC control signal wires install 120 208 240V to 24VAC Class 2 UL listed transformer Model 1601 01 shown in Figure 8 and Figure 9 Connect 120 208 240V common wire of transformer to 120 208 240V common...

Page 8: ...eenfan bipolar ionizer Model 1600 01 2022 greenfan inc 6 Figure 8 Bipolar ionizer installed with 120 208 240V to 24VAC transformer Figure 9 Installation schematic with 120 208 240V to 24VAC transforme...

Page 9: ...hrough holes in flanges on either side of unit with at least one inch clearance between carbon fiber electrodes and metal surfaces to ensure airflow over both electrodes Install greenfan bipolar ioniz...

Page 10: ...nergized or turned on e After completing all steps of the air purifier mechanical and electrical installation proceed to air purifier verification of proper operation 5 3 Air Purifier Verification of...

Page 11: ...th fan rotation c After completing all steps of mechanical installation proceed to electrical installation Figure 12 Bipolar ionizer installed at inlet of ventilation fan behind protective grill 6 2 V...

Page 12: ...usly illuminated when thermostat fan switch air purifier or fan is turned to the ON position then bipolar ionizer is operating properly The greenfan bipolar ionizer continuously monitors high voltage...

Page 13: ...lity Verified Zero Ozone This product meets UL 2998 and does not emit more than 0 005 ppm as tested per UL 867 d CAUTION HIGH VOLTAGE This equipment should be inspected frequently and collected dirt r...

Page 14: ...oduct at the time of original purchase and GREENFAN shall not be liable for any direct indirect consequential or incidental damages arising out of the use or inability to use the product An RMA is req...

Page 15: ...5 x 104 TCID50 ml achieving a 97 6 reduction within 60 minutes 74 5 reduction within 30 minutes and 45 reduction within 15 minutes when installed on the inlet of a blower fan circulating air in a 20 x...