background image

CSX

500

SERIES

MANUAL NO.CSX500-UM-152

USER’S MANUAL

IMAGE SCANNER

www.delinit.by

Summary of Contents for CSX500 SERIES

Page 1: ...CSX500 SERIES MANUAL NO CSX500 UM 152 USER S MANUAL IMAGE SCANNER www delinit by...

Page 2: ...g the manual Danger This category provides information that if ignored is highly likely to cause fatal or serious injury to the operator Warning This category provides information that if ignored is l...

Page 3: ...objects such as necklaces Objects such as glasses vases houseplants etc that contain water or other fluids If any of these objects does come into contact with the internal electrical components immedi...

Page 4: ...nstall use or store the scanner in a location that does not meet the specified temperature and humidity ranges Such location may impair the scanner s performance due to deformation or damage and cause...

Page 5: ...nect multiple devices to the same power outlet Use of the scanner in such a condition may result in a fire hazard or electric shock Do not bundle or tie wrap the power cable Use of a bundled power cab...

Page 6: ...or damaged areas may result in a fire hazard or electric shock Before cleaning the scanner be sure to unplug the power cable from the power outlet Failure to do so may result in electric shock Do not...

Page 7: ...ause a fire hazard or electric shock if it comes into contact with the scanner s internal electrical components Before moving the scanner make sure that the main power switch is in the off position an...

Page 8: ...power plug from the power outlet and either contact the store where you purchased your scanner or your nearest Graphtec representative Do not insert your hands inside the scanner during a scanning op...

Page 9: ...fire hazard or electric shock Do not attempt to lubricate the scanner s mechanisms Such action may impair the scanner s performance and cause the scanner to malfunction or break down Such action may c...

Page 10: ...ainst harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may caus...

Page 11: ...no liability for damages resulting from either the use of the information contained herein or the use of the product Registered Trademarks All names of companies brands logotypes and products appeari...

Page 12: ...Opening the top cover Do not hold the rear section of the top cover when opening it Top cover Document guides Top cover When closing the top cover please be careful not to pinch the document guides Al...

Page 13: ...ates 1 4 Attaching and using the cable clamp 1 4 CHAPTER 2 CONNECTION AND PREPARATIONS 2 1 Connecting to the Power Supply 2 1 2 2 Turning the Power On and Off 2 2 Turning the Power On 2 2 Turning the...

Page 14: ...ammed Document 4 8 4 9 Scanner Adjustment 4 9 Preparation and checks 4 9 Launching the Scanner Adjustment Program 4 9 Calibration 4 10 CHAPTER 5 TROUBLESHOOTING PROCEDURES 5 1 The scanner Is turned on...

Page 15: ...document cannot be fed correctly 5 5 5 16 Automatic Deskew is not performed correctly 5 5 APPENDIX Appendix A Options and Consumables A 1 Appendix B Specifications A 2 Appendix C External Dimensions A...

Page 16: ...epresentative Scanner unit 1 USB cable 1 Cable clamp 1 Power cable 1 Driver software 1 USER S MANUAL 1 Calibration sheet 1 Cleaning paper 1 Carrier sheet A0 1 CSX530 CSX550 only CSX500 SERIES USER S M...

Page 17: ...er saving mode Unlit The scanner is turned off 6 PAPER LED green Lit Lights when a document has been loaded Flashing Flashes while image data is being scanned Unlit Normal status Local status 7 ERROR...

Page 18: ...nt Use the Network Utility to reconfigure your settings see Section 2 7 13 Power inlet Used to connect the power cable 14 Main power switch Used to turn the main power supply on or off 15 Document sup...

Page 19: ...ent support plates when moving or packing the scanner Lift the plates up and out of the slots to detach them Attaching and using the cable clamp Attach the cable clamp to the scanner and then pass the...

Page 20: ...cker on the rear of the clamp and then attach the clamp to the scanner Cable clamp Using the clamp 1 Pull up the latch at the top of the cable clamp to open the clamp Latch 2 Pass the power cable the...

Page 21: ...nner s power inlet and the other end to an AC power outlet of the rated supply voltage Power inlet AC power outlet Power cable Caution Be sure to use the cable clamp provided with the scanner to faste...

Page 22: ...s control panel When the scanner is in the power on status the POWER button LED lights blue ON Turning the Power Off Press the POWER button on the scanner s control panel When the scanner is in the po...

Page 23: ...lashes after approximately 13 minutes have elapsed without a document being loaded in the scanner To return the scanner to normal status Local status press either the STOP or the EJECT key To cancel t...

Page 24: ...se Network Interface 10BASE T 100BASE TX 1000BASE T to connect the scanner via the Network interface USB 2 0 Interface that comes standard with your computer to connect the scanner via the USB interfa...

Page 25: ...alling the driver Remove or reinsert the cable while starting up the computer or the scanner Remove or reinsert the cable while transferring data Connect two or more scanners to a single computer Caut...

Page 26: ...T 100BASE TX 1000BASE T Check your network environment A Network cable is used to connect the scanner to the computer via the respective Network interface connectors Computer Network connector Reset b...

Page 27: ...he scanner yet 2 Insert the IMAGE SCANNER USER GUIDE CD ROM which came with the scanner into the CD ROM drive AutoPlay screen will appear shortly Select Run MultiSetup exe from there 3 The User Accoun...

Page 28: ...when you connects to the scanner Wait for the driver installation is finished It may take several minutes Checkpoint If the computer is not connected to the network the installation finishes immediate...

Page 29: ...licking the taskbar message in step 9 the following screen appears when the driver installation is finished 11 Select Devices and Printers using the Start menu on the Windows desktop to display the sc...

Page 30: ...Select Run MultiSetup exe from there 3 The User Account Control screen is displayed Click Continue to proceed with the installation 4 The Setup menu screen starts automatically Next select the Pre ins...

Page 31: ...cts to the computer 9 The following message appears on the taskbar when you connects to the scanner Wait for the driver installation is finished Checkpoint The following screen appears when you click...

Page 32: ...Hardware and Sound to display the screen shown below 13 Click Scanners and Cameras to display the screen shown below Check that connected scanner is displayed here The installation of driver software...

Page 33: ...cally after a while Next select the Pre install the scanner driver button If the Setup menu screen does not start open Windows Explorer and double click on MultiSetup exe within the CD ROM folder 4 Th...

Page 34: ...the following screen appears Select the option No not this time and then click Next When Service Pack 2 or later has been installed the following screen may appears 9 The following screen appears Sel...

Page 35: ...dware wizard 12 Launch the Control Panel using the Start menu on the Windows desktop 13 The screen shown below is displayed when you click on the Printers and Other Hardware icon 14 The screen shown b...

Page 36: ...ocedure The following steps are explained using the Windows 7 screens 1 Start up Windows 7 2 Insert the attached IMAGE SCANNER USER GUIDE CD ROM into the CD ROM drive AutoPlay screen will appear short...

Page 37: ...start shortly From this point on follow the set up program s instructions to install the Scanning Master Pro Color OPS115 application If the application has been properly installed Scanning Master Pr...

Page 38: ...ork Utility please be sure to first install the scanner driver software see Section 2 5 Installing the Scanner Driver Software Installation procedure The following procedure assumes that you are using...

Page 39: ...utomatically Next click the Install the Network Utility button If the Setup menu screen does not start open Windows Explorer and double click on MultiSetup exe within the CD ROM folder 5 When the foll...

Page 40: ...te For Windows 7 Windows Vista and Windows XP Service Pack2 the following Firewall Exception List Registration Confirmation will be displayed Click Yes 7 The screen shown below appears Click Next 8 Wh...

Page 41: ...ed from a location that a router is used to access depending on the type of router used there may be locations that cannot be searched In this case make the setting within the same segment 10 This wil...

Page 42: ...een shown below appears Select Yes and click Finish This completes the Device Setup operation Installing the Graphtec Network Utility 13 The screen shown below appears Click the Next button 14 The scr...

Page 43: ...a folder Note The default destination folder is C Program Files Graphtec Graphtec Network Utility Click Next 16 The screen shown below appears Set the name of the program folder and click Next 17 Clic...

Page 44: ...efore executing Graphtec Network Utility please be sure to first install the scanner driver software see Section 2 5 Installing the Scanner Driver Software 1 Set up the Graphtec Network Utility Launch...

Page 45: ...ling the Scanner Driver Software Windows 7 Step 9 of When using Windows 7 Windows Vista Step 9 of When using Windows Vista Windows XP Step 8 of When using Windows XP Checkpoint When using the Scanner...

Page 46: ...0 0 After initialization insert the IMAGE SCANNER USER GUIDE CD ROM which came with the scanner into the CD ROM drive Go to Install the Network Utility and use Setup to execute the Device Setup Refer...

Page 47: ...en index htm in the Address bar at the top of the screen Example http 192 168 16 77 en index htm 3 Select the System Information tab and click Reset 4 Enter root in the User name box and then click O...

Page 48: ...2 28 5 Click the Start button for Reset to Factory Default 6 Are you sure you want to reset to factory default appears Click OK 7 The following window is displayed after the setting has been made...

Page 49: ...2 29 8 Reboot the Network Board Select the System Information tab and click Reset 9 Click the Start button for Reboot 10 Are you sure you want to reboot appears Click OK...

Page 50: ...2 30 11 After the settings the screen below appears 12 This completes the initialization of the Scanner Network...

Page 51: ...A1 24 60 x 34 64 in A0 34 64 x 48 42 in Size JIS ISO Size JIS ISO A4 210 x 297 mm B4 257 x 364 mm A3 297 x 420 mm B3 364 x 515 mm A2 420 x 594 mm B2 515 x 728 mm A1 594 x 841 mm B1 728 x 1030 mm A0 84...

Page 52: ...types are listed below High grade paper 60 g m2 Tracing paper 50 to 55 g m2 Mylar 50 m Copy paper Diazo photo sensitive paper Be sure to use the carrier sheet when scanning a document where the ink o...

Page 53: ...s are not removed the document might get damaged when it s being fed Document to be scanned Document scanning table Top cover Document guides There are two document setting modes available For more in...

Page 54: ...he document may not be fed in correctly if it is curled The carrier sheet should be used for curled documents see Section 3 5 Using the Carrier Sheet for details Load the document in the center of the...

Page 55: ...10 09 0 65 to 0 8 Position of the below figure 2 Position of the below figure 1 Standard Position of the below figure 1 Standard Position of the below figure 1 Standard Position of the below figure 1...

Page 56: ...ing speed 1 Start up the Scanning Master Pro Color OPS115 software that is provided with your scanner and then display the Scan screen 2 Select the Options tab and then move the Scan Speed slider to t...

Page 57: ...of distance correction necessitates that you measure a vertical line drawn on the document before following the procedure described below 1 Choose a document that has one or more vertical lines drawn...

Page 58: ...es of paper have been attached When the target document cannot be properly advanced to the initial position of scanning because the target document is not flat or otherwise hard to load in the scanner...

Page 59: ...ver is fully open the fixing stay operates to hold the top cover in place Closing the top cover 1 Press the open cover down gently with both hands to close it 2 Check that the left and right open leve...

Page 60: ...ed with water or a neutral detergent diluted with water and firmly wrung out Feed rollers 4 Wipe the feed rollers once again using a soft dry cloth to remove all the moisture 5 Close the top cover as...

Page 61: ...ed with water and firmly wrung out Document support rollers 4 Wipe the document support rollers once again using a soft dry cloth to remove all the moisture 5 Close the top cover as described in Secti...

Page 62: ...ed with water or a neutral detergent diluted with water and firmly wrung out Gap rollers 4 Wipe the gap rollers once again using a soft dry cloth to remove all the moisture 5 Close the top cover as de...

Page 63: ...ed with water or a neutral detergent diluted with water and firmly wrung out Push rollers 4 Wipe the push rollers once again using a soft dry cloth to remove all the moisture 5 Close the top cover as...

Page 64: ...p cover as described in Section 4 1 Opening and Closing the Top Cover Caution Take care not to get your fingers caught in the cover Do not use a commercial cleaner for office equipment a glass cleaner...

Page 65: ...the two paper sensors or the five document size detection sensors using a cotton swab Document size detection sensors Paper sensors 4 Close the top cover as described in Section 4 1 Opening and Closin...

Page 66: ...4 1 Opening and Closing the Top Cover 3 If the document is jammed at the front remove the document by pulling it forward 4 If the document is jammed at the rear remove it by pulling it out from the re...

Page 67: ...ecks Recommended usage environment Monitor 1024 x 768 pixels High Color or better resolution Checkpoint A low resolution monitor will make it difficult to discern any problem areas Launching the Scann...

Page 68: ...vicing Handle the calibration sheet with care so that it does not get bent To prevent soiling store it in its special storage box The calibration sheet is a consumable item It cannot be used if it is...

Page 69: ...elect Specified Part in the Calibration screen 11 The mouse arrow cursor changes to a cross cursor when moved over the data Click the left mouse button with the mouse positioned over the streak data T...

Page 70: ...Are you using an USB cable not compliant with the USB 2 0 interface Ensure that you use a USB 2 0 compliant USB cable Is an add on USB card being used USB 2 0 add on cards are not supported Correct op...

Page 71: ...the driver The top cover is not fully locked Close the top cover firmly until it is locked in place see Section 4 1 Opening and Closing the Top Cover 5 5 The document isn t properly fed to the initia...

Page 72: ...ure below Remedy After opening the Tools menu of the driver program Scanning Master Pro Color driver provided with y Due to its operating environment or other factors however the scanning precision ma...

Page 73: ...curled documents should be scanned by placing them inside the carrier sheet 5 11 The document length differs from the scanned data length Cause Remedy Distance correction adjustments have been made to...

Page 74: ...g half way through The cause of this problem is often attributable to the weight or length of the document In such cases you should support the document with your hands when you insert it into the sca...

Page 75: ...can be obtained from the store where you purchased your scanner or your nearest Graphtec representative Options Part no Item name ST0074 Stand Consumables Part no Item name IS0922 Carrier sheet A0 IS...

Page 76: ...age data Rated power supply 100 to 120 200 to 240 VAC 10 50 60 Hz Operating environment Temperature 10 C to 35 C Humidity 35 to 80 RH non condensing Power consumption 42 W 4 3 W or less in power savin...

Page 77: ...power supply 100 to 120 200 to 240 VAC 10 50 60 Hz Operating environment Temperature 10 C to 35 C Humidity 35 to 80 RH non condensing Power consumption 42 W 4 3 W or less in power saving mode Externa...

Page 78: ...tput Image data Rated power supply 100 to 120 200 to 240 VAC 10 50 60 Hz Operating environment Temperature 10 C to 35 C Humidity 35 to 80 RH non condensing Power consumption 55 W 4 3 W or less in powe...

Page 79: ...A 5 Appendix C External Dimensions CSX510 09 CSX530 09 CSX550 09 Unit mm Dimensional accuracy 5 mm 1070 1097 322 160...

Page 80: ...A 6 CSX510 09 CSX530 09 CSX550 09 When the scanner is mounted on the stand Unit mm Dimensional accuracy 5 mm 972 1097 650 717 10...

Page 81: ...nal dimensions A 5 F Feed rollers Cleaning 4 2 Front View 1 2 G Gap rollers Cleaning 4 4 Graphtec Network Utility 2 22 Graphtec Network Utility Installing 2 22 Graphtec Network Utility Settings 2 24 H...

Page 82: ...ter Connecting 2 5 Scanner unit 1 1 Scanner warm up II Scanning Master Pro Color Application 2 16 Sensors Cleaning 4 7 Specifications A 2 ST0074 A 1 STOP key 1 2 System requirements 2 4 T TO ENSURE SA...

Page 83: ...The specifications etc in this manual are subject to change without notice CSX500 UM 152 June 22 2011 1st edition GRAPHTEC CORPORATION...

Page 84: ...Printed in Japan 503 10 Shinano cho Totsuka ku Yokohama 244 8503 Japan Tel 81 045 825 6250 Fax 81 045 825 6396 Email info graphteccorp com Web www graphteccorp com 640743301 www delinit by...

Reviews: