background image

1

WEBCS-1  09/18

 WARNING: FOR OUTDOOR USE ONLY!

 

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause 

injury or property damage. Read the installation, operating and maintenance instructions 

thoroughly before installing or servicing this equipment.

 

WARNING: Do not store or use gasoline or other  flammable vapors and liquids in the  vicinity 

of this or any other appliance.

 

WARNING: A propane cylinder not connected for use shall not be stored in the vicinity of 

this or any other appliance.

 

WARNING: For use with Natural or Propane gas only. NO SOLID FUELS TO BE USED WITH 

THIS SYSTEM.

FOR YOUR SAFETY

If you smell gas:

1. Shut off gas to appliance.

2. Extinguish any open flame.

3. If odor continues, keep away from appliance and im-

mediately call your gas supplier or fire department.

Weather Beater Electronic 

Control System

Model: WBECS

Owner's Operation and 

Installation Manual

CALIFORNIA PROPOSITION 65 

WARNING 

 

 

This product can expose you to Chromium, which is known to the state of 

California to cause cancer and birth defects or other reproductive harm.

(For more information, go to: www.p65warnings.ca.gov)

Summary of Contents for WBECS

Page 1: ...stored in the vicinity of this or any other appliance WARNING For use with Natural or Propane gas only NO SOLID FUELS TO BE USED WITH THIS SYSTEM FOR YOUR SAFETY If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues keep away from appliance and im mediately call your gas supplier or fire department Weather Beater Electronic Control System Model WBECS Owner s ...

Page 2: ...es 11 SYSTEM OVERVIEW Components are CSA Certified 12 vac system to comply to NEC 2014 Article 680 require ments 20 to 175 temperature range Durable connections designed to resist outdoor conditions 265 000 BTU s at 1 pressure drop TC Flame sense system Hot Surface Ignitor HSI LED diagnostics Electronics are ANSI Z21 20 2014 certified I Flame app is available as an option ELECTRONICS Certified ANS...

Page 3: ...WARNING The Weather Beater Electronic Control System operates on 12 Volts AC power DO NOT attempt to power using 110 Volts AC Power DAMAGE WILL RESULT Acceptable Input Voltages to Supplied 12 Volt AC Transformer 110 120 Volt AC Read label on supplied transformer for proper connection information Recommended Wire Size 16 gauge wire for all installations 30 feet maximum length WIRING OF MULTIPLE WBE...

Page 4: ...Minimum Wiring Two Units Gas Line Manual Gas Shutoff Key Valve Sediment Trap Minimum 18 sq inches of Cross Ventilation on Each Side of Enclosure Burner Pan Orifice Ignition Control Box Burner Pilot Burner Assembly Red Black 30 Maximum Wire length from transformer to splice point must be less than 30 using 16 gauge wire Top Sides and Bottom Clearances to Combustibles must be maintained in accordanc...

Page 5: ... installed in accordance with local building codes if any If not follow ANSI 223 1 Installation should be done by a qualified installer approved and or li censed as required by the locality Note A listed manual gas shutoff device must be installed prior to the location of the appliance Pilot Assembly The pilot is configured for natural gas A propane gas injector is provided in the kit Additional i...

Page 6: ... We recommend mounting the pilot shield on top of the burner pan and in that configuration the pilot line thermocouple and igniter lead should be lowered through a hole in the pan prior to connecting to the control box The pilot comes pre assembled from the factory so the in staller can simply connect the assembly to the main control box The igniter has a shaped push on waterproof connector ensuri...

Page 7: ... children in same area as the appliance Alert children and adults to dangers of high tempera tures Flammable materials should not be hung from the appliance or placed on or near the appliance WARNING The appliance must be inspected be fore use and at least annually by a qualified service technician Any guard or protective device removed for servicing must be replaced prior to operation Keep the ap...

Page 8: ...inimum of 18 square inches is required on each side of the installation See page 4 Air flow is your friend 2 Media lava rock and glass minimum of 1 2 and no larger than 2 in diameter 3 Media must not cover the pilot The pilot needs air Avoid packing media against the pilot 4 Media must be approved by the appliance manufacturer 5 Large BTU applications above 150 000 BTU s could require a large inje...

Page 9: ...begins to flow If at any point you smell gas and still don t have ignition you should attempt to light the pilot flame with a hand held lighter If ignition occurs when you light it by hand go to the section see Electrical Current in column 2 Electrical Current If purging the gas line does not solve the problem the ig nition failure is most likely that the the igniter is not getting hot enough to l...

Page 10: ... pilot jet is not for LP Check pilot injector for clogged jet Clean or replace If pilot can be lit with a match check igniter position and adjust or check No or Low Voltage above Pilot lights but goes off at end of trial without main burner 2 flash lockout after end of trials Flame is not detected Ensure pilot flame is impinging on the ther mocouple No Check for clogged pilot or injector and clean...

Page 11: ... Pilot Injector LP FT 3225 Pilot Injector Nat FT 3239 Pilot Injector Nat FT 24TC Thermocouple FT36TC Thermocouple FT WS WeatherSmart 12V 24V Blue Tooth WiFi FT TRN12 12 Volt Transformer with 30 Foot Cable FT TRN24 24 Volt Transformer with 30 Foot Cable FT NGCK Natural Gas Connection Kit FT LPCK Propane Connection Kit with Regulator FT LPM LPG Air Mixer PARTS LIST ACCESSORIES ...

Page 12: ...12 WEBCS 1 09 18 Grand Canyon Gas Logs LLC 3515 East Atlanta Ave Phoenix AZ 85040 Phone 602 344 4217 Fax 602 243 6523 www GrandCanyonGasLogs com ...