background image

MDE-HANDI-2078V4.0

 

1

 

E

NG

LI

S

H

 

 

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

HANDI

®

  CLOCKS 

USER GUIDE

 

 

 

 

HANDI

®

 300 

HANDI

®

 450 

HANDI

®

 620 

HANDI

®

 800 

 
 
 

 
 
 

 

Summary of Contents for HANDI 300

Page 1: ...MDE HANDI 2078V4 0 1 ENGLISH HANDI CLOCKS USER GUIDE HANDI 300 HANDI 450 HANDI 620 HANDI 800 ...

Page 2: ...nsent from the Customer service department will void the warranty The HANDI must only be installed maintained and handled by competent and knowledgeable persons All maintenance operations must be carried out with the power off including for systems connected to any relay outputs As a general rule to avoid any interferences the power 230V supply and signal time information cables must not be too cl...

Page 3: ...t not be disposed of with your general household waste Instead it is your responsibility to dispose of your waste by taking it to a designated collection point for the recycling of electrical and electronic appliances The separate collection and recycling of your waste contributes to the conservation of natural resources and helps to ensure that recycling is environmentally and health friendly For...

Page 4: ...Protocol 8 B Polaris Protocol 9 1 4 FIXING DIMENSIONS IN MM 10 1 4 1 HANDI 300 10 1 4 2 HANDI 450 11 2 HANDI 620 12 2 1 DESCRIPTION 12 2 2 CONNECTIONS 12 2 2 1 PULSE RECEIVER VERSION 12 2 2 2 AFNOR NFS 87500 IRIG B 122 RECEIVER VERSION 12 2 2 3 DCF24v RECEIVER VERSION 12 2 2 4 NTP RECEIVER VERSION 13 A 230VAC Version 13 B PoE Version 13 C Wi Fi Version 13 2 2 5 LIGHTING OPTION 13 2 3 FIXING DIMENS...

Page 5: ...E 18 4 1 FIRMWARE VERSIONS 1 X X X 18 4 1 1 Main web page 18 4 1 2 Ethernet web page 20 4 1 3 Security web page 21 A Secure Shell for expert users only 21 4 1 4 Time input web page 22 A NTP Synchronization options 23 B NTP Synchronization Information 24 4 1 5 SNMP settings web page 25 4 1 6 Firmware update web Page 27 4 1 7 FTP Firmware update 27 4 1 8 With Windows Command prompt 27 A With FTP cli...

Page 6: ...gh software 41 4 2 8 Web page Firmware Update 45 4 2 9 Firmware update via FTP 46 4 1 10 Web page Restart Restore 47 A Section periodically restart 47 B Section Factory Default and Restart 47 5 WI FI SETTINGS 48 5 1 GENERAL 48 5 2 WI FI SETTINGS BY WEB PAGE 50 5 2 1 Firmware 1 X X X versions 50 A Connection to the Wi Fi Access Point 50 B Access to web interface of the clock 50 C Web page Configura...

Page 7: ...figure To set the time on the clock manually use the knob on the back of the movement 1 2 2 AFNOR NFS 87500 IRIG B 122 RECEIVER VERSION Connect the AFNOR NFS 87500 IRIG B 122 code No polarity Depending on the power supply option connect the clock to the mains Change the switch position on the back onto the ON position Wait a few minutes until the clock hands reach 12h position After receipt of tim...

Page 8: ...IVER VERSION Connect the ASCII code by following the following table Green wire GND Brown wire RX White wire RX Connect the clock to the mains Change the switch position on the back onto the ON position The hands are positioned at 12 o clock and then 3 to 4 minutes after receiving the code are positioned according to the received time information A Gorgy Timing Protocol Reception Mode In this mode...

Page 9: ...tion using the protocol described in the above table generated by an RT4000 or any other ASCII code generator 2 Or the information from another clock of the same type functioning in transmitter mode in which case the clock is completely enslaved to the latter 3 In HORO QUARTZ specific version the time information from a HORO QUARTZ pointing system B Polaris Protocol The time information received m...

Page 10: ...10 MDE HANDI 2078V4 0 1 4 FIXING DIMENSIONS IN MM 1 4 1 HANDI 300 ...

Page 11: ...MDE HANDI 2078V4 0 11 ENGLISH 1 4 2 HANDI 450 ...

Page 12: ...ne as shown below in the opposite figure To set the time on the clock manually use the knob on the back of the movement 2 2 2 AFNOR NFS 87500 IRIG B 122 RECEIVER VERSION Connect the AFNOR NFS 87500 IRIG B 122 code No polarity Depending on the power supply option connect the clock to the mains Change the switch position on the back onto the ON position Wait a few minutes until the clock hands reach...

Page 13: ...nfiguration Wi Fi products to connect clock to Wi Fi network The hands are positioned at 12 o clock and then 3 to 4 minutes after receiving the code are positioned according to the received time information For the advanced configuration see chapter 4 WEB INTERFACE 2 2 5 LIGHTING OPTION Connect the LED lighting supply cable to the mains In NTP Version the LED lighting is power by the power cable I...

Page 14: ...2078V4 0 2 3 FIXING DIMENSIONS IN MM 2 3 1 SINGLE FACE MOUNTING WITH BRACKET The bracket can be fitted in the position of wall mount or side mount Fixation of the rod 2 screws of 6 x 16 Remark Mount at 6h on request ...

Page 15: ...s the cables through the rods Put the two clock sides back to back then assemble them by mounting the connecting plates on each corner bracket self tapping screws of 4 8 x 19 Fix the metal plate to the end of rod 6 screws of 5 x 20 Fix the circle strap onto the bracket 4 screws of 2 9 x 9 Screws supplied with the clock Side mount special attention shall be given to the fixation of rods mount at 3h...

Page 16: ... Wait a few minutes until the clock hands reach 12h position After receipt of time code the hands will reach the right position according to time information 3 2 2 NTP RECEIVER VERSION A 230VAC Version Connect the clock to the computer network Connect the clock to the mains B PoE Version Connect the clock to the POE injector C Wi Fi Version Connect the clock to the mains Consult chapter 5 Pre conf...

Page 17: ...MDE HANDI 2078V4 0 17 ENGLISH 3 3 FIXING DIMENSIONS IN MM ...

Page 18: ...your web browser Firefox Chrome Internet Explorer and enter the product IP address NB By default the product asks an IP address from DHCP server It always keeps an auto IP 169 254 x y 16 and Link Local IPv6 address fe80 64 To easily detect GORGY TIMING products in your network you can use the GTNetworkManager2 program or the old GT Network Manager version 4 1 1 Main web page When you enter the pro...

Page 19: ... IP address 1 IPv4 DHCP Static 1 IPv6 Link Local and 1 Global IPv6 DHCP Static which are dis played here with netmask in CIDR notation MAC Adress the product interface MAC address Network and Synchronization status to know if the product is connected to network and or synchronized or not and since when Firmware Version and Change Log the firmware version of the product and a history of the evoluti...

Page 20: ...set a static IP address Manual IP Settings option with network mask and gateway Network settings support IPv4 addresses IPv6 addresses or both ENDMI protocol allows the Gorgy Timing clocks and Time servers network discovery You can disable the ENDMI protocol on this web page In this case the product will not be visible by GTNetworkManager Software ...

Page 21: ...cess to SSH To enable SSH access one must check the corresponding box in the Security Web Page For security reasons SSH will only be active until the product reboots or the user disables it in the Security web page SSH login and password are the same as for FTP Default settings are GT_Tablet gtandroid These can be changed in Security Webpage Main commands Products are based on embedded Linux and u...

Page 22: ...display information about memory and CPU usage and about processes cur rently running in the product uptime display time since the product start users display username of currenlty logged in users Software in usr bin directory except those of Busybox are develloped specifically for the GORGY TIMING product We recommend that you DO NOT USE software which is not documented here in order to avoid any...

Page 23: ...ver in case they differ NTP client have numerous security to protect product against time inconsitency and or time hacking For exemple if a system have a large more than 128ms offset refering to other server in the list it will be discarded we say it named false ticker and a x will appear before server ip in Synchronization Information In a two server case if the two server have large offset betwe...

Page 24: ...er PPS DCF st stands for Stratum it is a level to tell how close to an atomic reference clock the time server is It could have value from 1 directly connected to atomic clock to 15 Value of 16 means the server is unreachable or there are synchronization problems t stands for Type in this product only NTP unicast u is available but NTP can also do for example broadcast b multicast m when is the tim...

Page 25: ...username SNMPv3 client must know this name to communicate with your products the same way that with the community for SNMPv1 2c This SNMP packet can be easily read from network and community settings found By setting MD5 Authentication Passphrase you will enable authentication of SNMPv3 packets so SNMPv3 client must know this password to send pac kets with the correct MD5 hash or they will be drop...

Page 26: ...e product noNTPSerDetected The NTP client could not synchronize because it received no response to retrieve the time information trackingNTPSer The NTP client is synchronized on the NTP server selected It generally fol lows the alarm neNTPSerSerlected to inform that the synchronization is done lostNTPSync The NTP client has lost the synchronization It usually happens if there is a network issue or...

Page 27: ... TIMING product during firmware update which will indicate you we when the product has been updated around 2 minutes after fir mware installation and reboot You can now check the product software version in product Index Webpage 4 1 7 FTP Firmware update You can also update your GORGY TIMING product with FTP protocol N B e sure FTP is enabled in the security Webpage and you have the correct system...

Page 28: ...tes will restart with the new software version check it in Index Webpage A With FTP client Filezilla Enter the product IP address and use GT_Tablet as login and gtandroid as password on the top of Filezilla windows Then click connect Drop with the mouse the firmware file GT_FW_Vx y z bin from the left to the fw directory on the right side The upload might begin The product will receive the firmwar...

Page 29: ...ress In this Webpage you can also export the product configuration for backup or send configuration to update GORGY TIMING product configuration it will restart the product 4 1 10 Reboot web page To restart the product click on Reboot button Product takes around 2 minutes to reboot and go back to the network 4 1 11 HANDI settings web page On this page the local time displayed on the HANDI can be c...

Page 30: ...product has To set the local time you can choose Iether a predefined time zone that includes time difference and time change policies For example Western_Europe gives the time of all Western Europe UK Ireland Portugal excluded and makes an automatic time change in April and October If you want to add a time zone not included please contact our Support support gorgy timing fr who will give you the ...

Page 31: ...rates Dubai Abu Dhabi Attention Oman UTC 4h Singapore UTC 8 No time change Singapore Indonesia Malaysia Philippines Sydney UTC 10 Summer Time First Sunday in October at 2 00 am Local Winter Time First Sunday in March at 3 00 am Local Australia Eastern part Sydney US_East_Coast UTC 5 Summer Time Second to last Sunday in October at 3 00 am Local Winter Time Second to last Sunday in March at 2 00 am ...

Page 32: ...ed here The LED can be turned on in the event of a synchronization fault during a synchronization or it can be set to always be off or on Reset and then stop the hands at 12 o clock For testing Resets the hands and locks them in the 12 o clock position This verifies that the hands are correctly positioned at 12 o clock on the movement and that the movement is also functioning correctly factory def...

Page 33: ...dress of the product like below NB By default the product will get its IP address by DHCP To easily detect GORGY TIMING products on your network you can use program GTNetworkManager2 4 2 1 Main web page HOME When you enter the IP address of the product in a WEB browser no connection information is required to access to the first page which is the home page of the clock But authentication will be n...

Page 34: ...ss IPv4 address MAC Adress MAC address Synchronization Status Network and synchronization status Current NTP server Used Indicates which NTP server is used for UTC synchronization Latest Time Correction Last internal time correction seconds and milliseconds and microseconds Updated at each NTP response Current Internal Time UTC UTC hour of the product Current Local Time Local hour of the product a...

Page 35: ...DHCP Dynamic IPv4 address allocation DHCP is the default configuration It is also possible to specify a static IP Manual IPv4 address configuration with the sub network mask Gateway and DNS server The product only support IPv4 addresses ENDMI protocol is used to discover the clock and time servers from GORGY TIMING on the network ...

Page 36: ...cally By selecting manually until three NTP servers or pools Set manually the NTP server s IPv4 addresses below At least one server should be given for the clock to synchronize IP addresses or names can be used with the presence of DNS server MD5 authentication is also possible until 8 key ID The order of the servers defines the priority for the synchronization The NTP client chose the first serve...

Page 37: ...anually This mode is called autonomous mode Once applied the internal hour of the clock is defined by the fields Year Month Day Hours Minutes Seconds filled by the user N B The product only deals with UTC hours In order to deactivate the autonomous mode it is necessary to go back to the NTP configuration web page and click on Apply ...

Page 38: ...tly support the following DST policies Western Europe Central Europe Eastern Europe Australian Central Australian Eastern US Alaska US Canada Pacific US Canada Mountain US Canada Central US Canada Eastern US Canada Atlantic Chili Cuba Fiji West Greenland East Greenland Jordan Lebanon Mexico New Zealand Paraguay Samoa Syria Moreover it is possible to configure a chosen DST thanks to Manuel Date or ...

Page 39: ...word to confirm it By default the password is gtmt Enter the new password Enter the new password wanted up to 32 characters Confirm the new password Confirm the new password Warning If the previous current password is not correct the configuration is not taken into account Once the update is applied the user is redirected to the home page The new password is required to access the configuration th...

Page 40: ...todetection thanks to the GORGY TIMING tools It is available on the label on the back of the product Note The maximum length of the fields is up to 50 characters Available characters are all the 95 printable ASCII chars excepted 0123456789 ABCDEFGHIJKLMNOPQRSTUVWXYZ _ abcdefghijklmnopqrstuvwxyz Community Value of the community is by default public The field is limited up to 7 characters Only the e...

Page 41: ...is down or if there is no server available anymore userLocked User forced the product in autonomous mode The following traps are sent in this mode lostNTPSync trackingNTPSer newNTPSerSelected ni ntpStarting SNMP write services If ON is checked the SNMP service is activate in writing mode If OFF SNMP service is deactivated in writing mode The MIB file Management Information Base of the product is d...

Page 42: ...tTempText 2 3 0 Y Y No used in HANDI tempValue 2 4 0 Y N Temperature value if the temperature option is activated Else useButtons 2 5 0 Y Y No used in HANDI ntpInputVersion 3 1 0 Y N NTP version used ntpInputMode 3 2 0 Y N Current mode of NTP Client Server Broadcast Else ntpInputAuto 3 3 0 Y Y Automatic detection state of the server Automatic or server filled by user ntpInputOption 3 4 0 N N No ef...

Page 43: ...3 0 6 Y Y Unused in HANDI disUnitEntOption 5 2 1 4 0 6 N N Unused in HANDI disUnitEntColor 5 2 1 5 0 6 Y Y Unused in HANDI disUnitEntLum 5 2 1 6 0 6 Y Y Unused in HANDI disUnitEntOffset 5 2 1 7 0 6 Y Y Unused in HANDI disUnitEntDstLang 5 2 1 8 0 6 Y Y Unused in HANDI disUnitEntDstInter val 5 2 1 9 0 6 Y Y Unused in HANDI disUnitEntMessag e 5 2 1 10 0 6 N N Unused in HANDI disUnitEntPeriod 5 2 1 11...

Page 44: ...and Start down up Reset Clear config Auto start up down Pause chronoOptions 6 8 0 Y Y Unused chronoTime 6 9 0 Y Y Time of the chronometer ntpStarting 0 3 Y N Trap SNMP autoNTPSerDetect 0 4 Y N Trap SNMP noNTPSerDetecte d 0 5 Y N Trap SNMP newNTPSerSelect ed 0 6 Y N Trap SNMP trackingNTPSer 0 7 Y N Trap SNMP lostNTPSync 0 10 Y N Trap SNMP userLocked 0 11 Y N Trap SNMP ...

Page 45: ...The file should be named GT_FW_xxxx bin given by the SAV GORGY TIMING Then click on Download which will be available only if a file is selected The udpate could last long Do not unplug the alimentation cable during the update Do no restart manually the product After a few seconds the web page will indicate than the product is going to reboot ...

Page 46: ... FTP is activated on the web page and that your IDs are the correct ones On windows Open the command console on Windows in the repository where is stored the binary to upload GT_FW_Vx y z bin You can check the folders thanks to dir Then enter ftp ip_address User admin Password gtmt put GT_FW_Vx y z bin quit The update will start after some minutes The product will reboot by itself ...

Page 47: ...ion check Restore factory settings after restart then click on Restart The produc twill reboot after some minutes and will be detectable on network Warning All the configuration static IP etc will be reset The produc twill start in DHCP mode To trigger a reboot without the factory default configuration keeping everything do not check Restore factory settings after restart but just click on Restart...

Page 48: ...y Timing products To connect to Wi Fi access point the product needs at least 2 parameters SSID name of Wi Fi access point which we want to connect the product Access point password N B In WPA Enterprise mode you will also have to give an username and sometimes a domainname also When a Gorgy Timing Wi Fi product fails to connect to a Wi Fi network for any reason no configuration no network wrong e...

Page 49: ...ument delivred with each command IP Address 192 168 2 1 Subnetwork Mask 255 255 255 0 Moreover in Accès point Mode the product enable its own DHCP server which gives automatically an IP address in the product subnet range 192 168 2 x 24 to computers which connect to the product Wi Fi configuration will be done by following these steps Connect to product Access Point Transfer of the configuration t...

Page 50: ... web interface of the clock When the computer is connected it should receive an IP address like 192 168 2 x 24 by DHCP To access the configuration interface open a web browser Firefox Chrome Internet Explorer and enter the following IP address 192 168 2 1 in the address bar The browser will then ask the user to identify themselves The default credentials are login root Password gtmt C Web page Con...

Page 51: ...onfiguration web interface becomes accessible using the Wi Fi clock s IP address on the Wi Fi network N B If not after trying for 1 minute to connect the clock returns to access point mode to receive a new configuration 5 2 2 Firmware 120 X X X Versions A Connection to Wi Fi access Point First it is necessary to be connected on the Access Point of the Wi Fi product 1 Using the available tools dete...

Page 52: ...he product is 192 168 0 2 To access the configuration interface open a web browser Firefox Chrome Internet Explorer and enter the following IP address 192 168 0 2 in the address bar In the Home page Login Status Requires login to follow the explanations in the next section By default login admin password gtmt Network Status Corresponds to the network status of the clock WIFI AP corresponds to the ...

Page 53: ... the frequency bandwith which could be used Color change in Access point mode Not available in HANDI Disconnect Force the deconnection and return to access point If the clock was in access point then it changes IP address automatically assigned by DHCP server or manually configured and the connection to the Wi Fi GET_LEDI_xxxx is no longer possible The terminal PC Smartphone tablet is thus disconn...

Page 54: ...n is lost the clock tries to reconnect but if the reconnection is not possible due to the distance between the clock and the access point or to a loss of network then the clock returns to the access point at the address 192 168 0 2 At this point the procedure for connecting to a network must be repeated ...

Page 55: ...is PoE powered and the Ethernet Port is not connected to PoE compatible IEEE 802 3af switch or injector Connect the product to PoE compa tible IEEE 802 3af switch Product have wrong hour information Product is not synchronised Check the Synchronization Code Input is correctly plugged and confi gured Product have time setting of another timezone Set timezone setttings Offset DST in synchronization ...

Page 56: ... the computer to have the same subnetwork than the product or use additionnal Unicast range of GTNetworkManager2 Firewall spyware or other security block GTNetworkManager2 Check with your network adminis trator firewall spyware and network security to allow GTNetworkMana ger2 to send and recieve packets especially Broadcast ones I detect the product but I cannot access it Web Page Product use HTTP...

Page 57: ... timing fr www gorgy timing com TECHNICAL SUPPORT RADIO TIMING LEDI LEDI CA HANDI are trademarks by GORGY TIMING Number of statement for training provider activity 82 38 04877 38 GORGY TIMING RC 74 B 38 Any technical aesthetic color modifications can be made without notice FROM France DEPUIS LA FRANCE SUR UN POSTE FIXE support gorgy timing fr support gorgy timing fr ...

Reviews: