background image

 

        
 
 
GDI6202/GDI6424/GDI/6434/GDI6444/ 
         GDI9202/GDI9424/GDI9434 

                   2 Person and 3 Person Model Saunas 

 
 
 
 
 
 
 
 
 
 
 

 

OWNER’S MANUAL 

FOR CARBON MODEL SAUNAS 
FOR INDOOR USE ONLY 
GDI6202/GDI9202 - 120V 15 AMP DEDICATED CIRCUIT 
GDI6424/GDI6434/GDI6444/GDI9424/GDI9434 - 120V 20 AMP DEDICATED CIRCUIT 

Sauna: Now you can enjoy the European secret for youthful vitality. 
Carefully and thoroughly read this manual before using the sauna.  We  
recommend keeping this manual for regular review and future reference. 

Summary of Contents for GDI/6434

Page 1: ...R INDOOR USE ONLY GDI6202 GDI9202 120V 15 AMP DEDICATED CIRCUIT GDI6424 GDI6434 GDI6444 GDI9424 GDI9434 120V 20 AMP DEDICATED CIRCUIT Sauna Now you can enjoy the European secret for youthful vitality Carefully and thoroughly read this manual before using the sauna We recommend keeping this manual for regular review and future reference ...

Page 2: ...ured in microns near infrared 0 76 1 5 microns middle infrared 1 5 5 6 microns and far infrared 5 6 1000 microns Among these segments only far infrared penetrates organic substances such as the human body two to three inches so that the warming effect is very uniform ARE INFRARED RAYS SAFE Because infrared rays are part of sunlight they are not only safe but also highly beneficial to our bodies on...

Page 3: ...ternal organs without putting too much burden on the heart Our body reacts to the increased heating through the natural cooling process of perspiring Through the perspiration process acid and waste residue like toxins sodium alcohol nicotine cholesterol and the potentially carcinogenic heavy metals are removed from the cells especially zinc lead nickel cadmium etc The pores of our skin open and di...

Page 4: ...itted by your sauna are reported to offer a wide range of possible therapeutic benefits based on research completed over the last 25 years from all around the world These benefits are presented for reference purposes only and no implication of infrared saunas creating a cure for or treating any disease is implied nor should it be inferred If you have a health condition are taking prescription drug...

Page 5: ...dealer or manufacturer for troubleshooting and replacement parts 1 Product Introduction The infrared sauna room is composed of a wood cabin infrared heat emitters and a control system The wood cabin includes a FLOOR PANEL RIGHT SIDE WALL PANEL FRONT PANEL with GLASS DOOR LEFT SIDE WALL PANEL REAR WALL PANEL ROOF PANEL BENCH HEAT EMITTER PANEL and BENCH The infrared sauna comes with an interior con...

Page 6: ...6 PARTS DESCRIPTION GDI6202 GDI6444 ...

Page 7: ...oup II Component Labeling POWER Power Cord HT1 HT2 HT3 HT4 Emitter heater power cords LIGHT Reading lamp connector ROOF LAMP Roof lamp connector not available on all models COLOR LAMP Color lamp connector not available on all models CTRL Control panel connector CD SIG For speakers temperature sensor buzzer etc connectors CD POWER CD radio power connector not available on all models FAN POWER CD ra...

Page 8: ...re 4 Figure 2 Model Radio May Vary IV Buckles A External Buckles The external buckles are used to connect the REAR WALL PANEL to the LEFT SIDE WALL PANEL and RIGHT SIDE WALL PANEL see Figure 3 Figure 3 B Metal Guide Insert Brackets The Metal Guide Insert Brackets connect the FRONT WALL PANEL to the LEFT SIDE WALL PANEL and RIGHT SIDE WALL PANEL see Figure 4 Figure 4 ...

Page 9: ...le to move around the FLOOR PANEL in order to install the sauna wall panels To identify the front of the FLOOR PANEL locate the FLOOR HEAT EMITTER PANEL with the wood grid cover Again this is going to be the front of the Sauna room once assembly is completed Depending on your sauna model the floor heater cord will be on the back side of the FLOOR PANEL on either the right or left side see Figure 6...

Page 10: ... Figure 7 C Roof Panel The ROOF PANEL houses the power supply speakers MP3 AUX jack and reading lamp Once installed all the wiring harnesses plugs and connections will sit on the exterior side of the roof ...

Page 11: ...nstalling the FLOOR PANEL 1 Place the FLOOR PANEL on the floor Some models have wood braces that must be installed on the underside of the FLOOR PANEL Not all models have these Please check to see if such wood braces were packed in the box containing the FLOOR PANEL If so mount according to the designated A B or C labels located on the underside of the FLOOR PANEL Once installed turn the FLOOR PAN...

Page 12: ...L Secure into place by pulling downward on the LEFT SIDE WALL PANEL Make sure the Metal Guide Insert Brackets are locked into place and the top of the FRONT WALL PANEL is flush with the LEFT SIDE WALL PANEL Do the same for the RIGHT SIDE WALL PANEL see Figure 9 Figure 9 D Installing the REAR PANEL 1 Remove the protection paper tape from the buckles on the REAR WALL PANEL Place the REAR WALL PANEL ...

Page 13: ...responding inlet located on the REAR WALL or SIDE WALL PANEL Also plug in the FLOOR HEAT EMITTER PANEL connector to the corresponding inlet on the REAR WALL or SIDE WALL PANEL 3 Install the BENCH at an angle as also seen in Figure 11 Then slide it over the horizontal bench guides on the side panels Slide the BENCH all the way in and against the REAR WALL PANEL Make sure to install the BENCH with t...

Page 14: ...place Make sure that the wires are properly fed through the holes Furthermore make sure the ROOF PANEL sits snugly into the RIGHT SIDE WALL PANEL and RIGHT FRONT WALL PANEL Pull down on the ROOF PANEL slightly to make sure it is secured in place see Figure 15 Figure 15 G Connecting the plugs on the ROOF PANEL 1 Connect the plugs according to their respective labels see Figure 16 2 Connect the CTRL...

Page 15: ...RE SENSOR is damaged during transit The manufacturer decides this according to sauna models and packaging 2 If your sauna comes with the optional Magazine Rack Shelf and or optional Towel Rack use the screws provided to mount the Magazine Rack in the lower left hand side of the interior FRONT WALL PANEL in front of the glass window panel and the Towel Rack to the interior RIGHT SIDE WALL PANEL Fur...

Page 16: ... wood sides for the CD Radio housing There is one for the front side and bottom see figure 15 2 Attach A on side panel with A on bottom panel and insert screws see figure 16 3 Attach B on front with B on side panel and C on front panel with C on bottom panel and insert screws see figure 17 4 Screw the RADIO BOX to the REAR PANELS The back opening the larger opening on the RADIO BOX will face the R...

Page 17: ...at the connections to the POWER SUPPLY HEAT EMITTERS CD RADIO and TEMPERATURE SENSOR are connected properly The power supply voltage and frequency must match the requested voltage and frequency of the sauna 120VAC 15AMP Dedicated Circuit or 120VAC 20AMP Dedicated Circuit Since many materials absorb the infrared rays minimal clothing is recommended for maximum effect The infrared sauna emitters are...

Page 18: ... the sauna to 50 degrees Celsius 122 degrees Fahrenheit When the ambient temperature is low heating requires additional time For the first few times of use you may use 46 degrees Celsius 115 degrees Fahrenheit as a reference starting point for a time period of about 30 minutes this represents the actual time you are in the sauna at the desired temperature As you become more comfortable and familia...

Page 19: ...dicates the working status of the sauna Heat Indicator Indicates the status of heating function Light Press to control the lighting function Time Display Displays the heating time of the sauna in minutes Time Press to adjust the setting of the timer Temperature Display Displays the actual interior temperature of the sauna room in 0 C 0 F Temperature Press to adjust the temperature setting 0 C 0 F ...

Page 20: ...d deeper 10 To conserve energy consumption please unplug your sauna when not in use 11 After the sauna session is over do not jump into the shower or bath immediately Because your body was heated up during the sauna session it will continue to perspire even after the heat emitters are off Sit in the sauna with the door open slightly and let your body cool down Once your body has cooled down and yo...

Page 21: ...horized repair attempts will void manufacturer s warranty 19 Please make sure the outlet power supply meets the specifications required Failure to meet the requirements may cause safety risks 20 Some sauna models are equipped with reading and roof lamps Because the lamp temperature will become very hot once powered on do not attempt to touch the lamp to avoid being burned Do not attempt to touch i...

Page 22: ...hey are straight and not bent firmly reconnect the CTRL wire harness Attempt to turn the sauna on at the control panel and check to see if the buttons are now responding Contact the manufacturer for any additional troubleshooting Solution The control panel will not turn off the power work or heat lights do not come on or the temperature and timer buttons do not work means the control panel may hav...

Page 23: ... the wiring harnesses coming from the power supply located on the roof of the sauna Make sure the wiring harness labeled CTRL is connected to the power supply at one end and connected to another wiring harness labeled CTRL at the other end If this wiring harness is not properly connected then the sauna will show signs of having no power 4 CD Player Will Not Work optional CD Players only available ...

Page 24: ... of purchase documents will be cause to VOID this limited warranty Products on which the serial number has been defaced or removed is not eligible for warranty service Warranty Limitations This warranty does not apply if the unit has been subject to negligence alteration modification misuse abuse repairs by non Golden Designs Inc authorized personnel inappropriate installations or any case beyond ...

Page 25: ...25 PAGE INTENTIONALLY LEFT BLANK ...

Page 26: ...s receipt showing date of purchase as this will serve as proof of purchase Warranty will be VOID if the following warranty card is not mailed back within 60 days of purchase date along with proof of purchase Serial number S N is located on the sauna s front panel rear panel or on the carton DETACH HERE WARRANTY CARD All fields must be completed to validate the warranty Name Address City State Zip ...

Reviews: