background image

-1-

DYGIZONE

GJD910 Lighting Controller & Enunciator

MASTER WIRING IDENTIFICATION

Power up to the DygiZone and you will see: 

 

All the LED’s (red,yellow,green and blue buttons) will flash

✓ 

All the LCD icons will light up (there is no audible noise) The 

blue LCD backlight does not come on

✓ 

The display will automatically clear after 1 minute, or if any 

button is pressed. When the display clears and nothing is 

activated

✓ 

The LCD displays the clock time (automatically defaults to 

00:00)

 

✓ 

The symbol M appears on the DygiZone which is configured 

as the master controller: The letter M does not appear when 

setting up a DygiZone as a slave controller

The three zone LED’s will display whatever zone state has been 

last programmed or the default setting. The default setting is 

audible and automatic for all active zones.

Remove insulating strip from clock back up battery on master 

controller

Zone Indicator Icons explained

Along the bottom of the LCD display up to three sub-zone 

circular Icons will be displayed above each numbered Zone 

button. These will only be displayed when an associated detector 

connected to A1,A2 or A3 on the Expansion Unit is activated. 

When corresponding detectors connected to A1,A2 or A3 inputs 

are activated then-

 The LCD screen will display the zone number 1,2 and 3

 A circle will appear around the zone number if that sub-zone 

detector is activated

The circle flashes on the screen in the same way as the PIR text 

whenever a PIR is triggered. -

i.e. the circle flashes for 8 seconds upon activation and then 

remains on for pre-programmed time duration (time on )

After that time as elapsed, the circle will disappear. 

Note: the numbers 1,2 or 3 always remain steady and never 

flash. 

When the PIR’s have not been activated

 The large circular bluer Zone buttons (1-4) will not be 

illuminated 

 The clock and M display will remain visible but all other icons 

on the LCD are turned off

 The zone status LED’s that are required will be displayed.

Zone Status Icons 

(only visible when the zone button is 

pushed). At the top in the middle of the LCD, three zone status 

icons will be displayed in various combinations, depending on 

how the zone has been set up

      1. A light bulb icon represents external lights are on from a  

       detector activation, manual override more or timer operation 

and mimics the yellow LED

      2. The musical note icon is shown when the audible mode is 

      selected and mimics the red LED. 

      3.If voice message mode has been selected(vs beep) then  

      the microphone icon will also display on the LCD. 

       4. The stick man icon represents the automatic mode and  

       mimics the green LED

LED lights explained

Red = Audible Mode - either beep more or voice message 

mode.

Green = Automatic Mode - works in conjunction with the 

photocell in the detector. The external security lights will only be 

activated if it is dark and thereby saves energy.

Yellow = Manual Override - the external security light will now 

remain on irrespective of detector status - useful for barbeques or 

when working outside in the dark for long periods

Yellow = Lighting Activated - the external security lights have 

been activated by a detector and will remain on for the pre set 

time

Yellow = Timer Active - the external security lights are on 

because the Timer 1 or Timer 2 options are programmed to be 

active.

The DygiZone Control and Monitoring Status can be 

set individually for each Zone as follows-

1.Pressing a Zone button selects the Zone to be set up. The LED’s and the  

   LCD display icons will display the current status e.g. Green LED and stick  

   man means auto more has been selected.

2. A second press on the same button will now light the red LED (green LED    

 turns off). The musical note icon will now show on the LCD plus a microphone    

   symbol if voice message has been selected.

3.Pressing the zone button again will turn off all the LED’s and icons.

4. Press once more and the yellow LED lights and the light bulb icon displays  

    in the LCD. This now sets the DygiZone to manual mode for that specific  

    zone and the lights will come on and stay on.

5.One more press and both the green and the red LED’s come on indicating  

   that audible and automatic mode have been selected.

LOCKING THE KEY PAD

Locking the key pad prevents accidental programme or settings changes. 

To Lock - press and hold down the Zone buttons 1 and 4 at the same time - a 

single beep will be hear and the spanned symbol on the keypad will flash to 

confirm that the key pad is locked.

To unlock - repeat the action and two beeps will be heard, and the spanner 

symbol will disappear

When a PIR detector in a zone is triggered, the 

following zone information is displayed - 

LCD Information and Text

✓ 

PIR text will flash for approximately 8 seconds for that zone

✓ 

The blue LCD backlight will come on for about 6 seconds during the trigger 

state and will remain on after the trigger has occurred. 

✓ 

The text remains on for a time duration (time-on) equal to the time that has 

been pre-set in the Mins Setting.

If the DygiZone is triggered during the hours of darkness: 

✓ 

The external security light will also be activated for the pre-set time. 

Note: If another PIR activation occurs on any other zone then the text will be 

displayed for that new zone for the same pre-programmed time on duration

Recording a voice message to audible indicate 

which zone has been activated

1. Press and hold the red button until the microphone symbol appears on 

the LCD

2. Press the required Zone button once and then release. As you release  

    the zone button a horizontal bar with ten segments will appear below the  

    microphone symbol on the LCD. This indicates the amount of recording time  

    available where each segment is equivalent to one second therefore a ten  

    second message can be recorded.

3. Speak into the microphone on the front cover of the DygiZone to indicate  

    location (e.g. patio area, front door, side garden etc)

4. When you have finished speaking into the microphone quickly press the  

    zone button again ( there will be no audio beep).

5. The recorded message will now automatically play back. If you are satisfied  

    with the message do nothing but if you wish to re-record the message  

    repeat steps 1 to 5. 

6. Press and hold down the red button until the microphone symbol appears in  

    the LCD and then release.

7. Now press and continue to hold down the zone button for which the voice  

    message is to apply, until an audible beep is heard-release the zone button  

    and the programming has been completed. 

    The voice message mode can be confirmed by pressing the the zone button    

    once and a microphone symbol will appear on the LCD if audible mode has  

    been pre-selected.

Summary of Contents for DYGIZONE GJD910

Page 1: ...security lights are on because the Timer 1 or Timer 2 options are programmed to be active The DygiZone Control and Monitoring Status can be set individually for each Zone as follows 1 Pressing a Zone button selects the Zone to be set up The LED s and the LCD display icons will display the current status e g Green LED and stick man means auto more has been selected 2 A second press on the same butt...

Page 2: ... RFX GJD detectors but does not apply to the OPAL XL detector Mode Settings One of five modes can be programmed for each Zone Mode 1 24 hr Lights operate day and night with detection when auto is selected Mode 2 Link Zone 1 Detectors on Zone 1 also activate lights on Zone 2 when auto is selected Mode 2 Link Zone 2 Detectors on Zone 2 also activate lights on Zone 1 when auto is selected Mode 2 Link...

Page 3: ...e Remove battery from master controller Press and hold down both Zone 1 4 button and then re apply the power The clock will be reset and the programme will revert to default settings where all the Zones are set to audible and auto modes i e the red and green LED s will be lit on all Zones Replace battery Note after a power down power up the detectors connected to the GJD expansion Unit will not ac...

Page 4: ... 4 ...

Page 5: ... 5 ...

Page 6: ... 6 4 ZONE EXPANSION UNIT WIRING DIAGRAM ...

Page 7: ...ory Default 1234 2 Press PROGRAM 8 ENTER 1 ENTER Display will show Output Press 1 to program Output 1 Press 2 to program Output 2 etc Display will show Output 1 Timed Press 1 to Latching Toggles Press 0 to return to instant Press ENTER to save your selection HOW TO SELECT THE TIME OF A PULSED MOMENTARY OUTPUT Factory Default 5 Seconds Quick guide Press 1 2 3 4 PROGRAM 8 ENTER 2 ENTER N ENTER Time ...

Page 8: ...Telephone Quick guide Call the Communicator and Press 1 2 3 4 1 Check that the voice message and at least one phone number has been programmed into the Communicator 2 Call the Communicator telephone number of the SIM card that has been installed You will hear a long beep to indicate that the Communicator has answered The Communicator s display will read Call in 3 Press 1 2 3 4 4 digit code followe...

Page 9: ...end s telephone keypad to stop the dialling sequence When the Communicator starts dialling it will dial the first telephone number and repeat the pre recorded voice message three times The number dialled will appear briefly on the display and the display will then show the Telephone Number in sequence being called If there is no response or acknowledgement or pressed from that number then it will ...

Page 10: ... further programming section selects whether it remains On for a time between 1 and 99 seconds before automatically turning Off User Activation of the Outputs From the Communicator Quick guide Press 1 2 3 4 0 1 the number of the output 1 Press 1 2 3 4 followed by 0 followed by the number 1 4 being the number of the output you wish to turn ON Output 1 in this example 2 The Communicator will show Ou...

Page 11: ... 1234 ESC key press ENTER to display the network reception quality on the LCD display A number between 0 and 7 will appear The strongest reception quality is 7 The Communicator should only be installed in a location where the signal strength display shows 2 or above Move the Communicator to a different location if the number is 1 or below You can continue to check the network reception strength at...

Page 12: ... 1 You should now see various numbers between 1 and 0 illuminated If a number is unlit it means it is not being dialled for Trigger 1 Toggle numbers on off by pressing that number on the keypad A number must be shown if it is being dialled for that trigger Q The Communicator s input has been activated correctly and a message has appeared in its display to indicate this however it is not then diall...

Page 13: ...ENGINEER NOTES Technical 01706 363990 Sales 01706 363998 Fax 01706 363991 Email info gjd co uk Unit 2 Birch Business Park Whittle Lane Heywood OL10 2SX ...

Reviews: