background image

MC62-G40

AMD Ryzen™ Threadripper™ Server Board

User Manual

Rev. 1.0

Summary of Contents for MC62-G40

Page 1: ...MC62 G40 AMD Ryzen Threadripper Server Board User Manual Rev 1 0...

Page 2: ...BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short gui...

Page 3: ...BIOS Setup 26 2 1 The Main Menu 28 2 2 Advanced Menu 31 2 2 1 Trusted Computing 32 2 2 2 AST2600 Super IO Configuration 34 2 2 3 S5 RTC Wake Settings 36 2 2 4 Serial Port Console Redirection 37 2 2 5...

Page 4: ...PBS Menu 81 2 4 1 RAS 82 2 5 Chipset Setup Menu 84 2 5 1 North Bridge 85 2 6 Server Management Menu 86 2 6 1 System Event Log 88 2 6 2 View FRU Information 89 2 6 3 BMC VLAN Configuration 90 2 6 4 BMC...

Page 5: ...G40 Motherboard Layout CPU DIMM D DIMM C DIMM B DIMM A DIMM E DIMM F DIMM G DIMM H 1 2 3 4 5 6 8 7 9 16 10 11 12 13 14 15 17 18 19 25 26 21 22 23 24 20 27 28 29 30 31 32 33 34 35 36 38 37 39 40 41 42...

Page 6: ...II PCIe Gen4 x4 Signal 20 SL_CN3 SlimLine SAS 4i Connector SATA III PCIe Gen4 x4 Signal 21 SATA_0_1 SATA III 6Gb s Connector 0 1 22 SATA_2_3 SATA III 6Gb s Connector 2 3 23 PMBUS1 PMBus Connector 24 F...

Page 7: ...PCIe4 0 x16 PCIe4 0 x16 PCIe4 0 x8 PCIe4 0 x16 Slot4 PCIe x16 Slot3 PCIe x16 Slot2 PCIe x16 Slot1 PCIe x16 Redriver x4 1 x USB3 2 Gen2 Type A 1 x USB3 2 Gen2 Type C USB3 2 Gen2 x2 USB3 2 Gen1 x4 Redri...

Page 8: ...y and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before un...

Page 9: ...rated in Aspeed AST2600 2D Video Graphic Adapter with PCIe bus interface 1920x1200 60Hz 32bpp Audio Realtek ALC4080 HD audio codec Supports 7 1 channel configurations 3 ports Audio Jack Audio in Audio...

Page 10: ...torage 1 x M 2 slot for Wi Fi 3 x U 2 connector 1 x Front panel header 1 x Back plane board header 1 x PMBus header 1 x IPMB header 1 x TPM header 1 x COM header Rear I O Connectors 2 x USB 3 0 ports...

Page 11: ...with CPU installed into place in the CPU socket Read the following guidelines before you begin to install the CPU Make sure that the motherboard supports the CPU Always turn off the computer and unpl...

Page 12: ...om the power outlet before installing the memory to prevent hardware damage Memory modules have a foolproof design A memory module can be installed in only one direction If you are unable to insert th...

Page 13: ...all DDR4 DIMMs on to this motherboard Follow these instructions to install a DIMM module 1 Insert the DIMM memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both...

Page 14: ...e into the slot Step2 Secure it with the screw tightening as necessary to fasten the M 2 SSD module in place 1 2 Follow the steps below to install a M 2 WiFi module on your motherboard Step1 Carefully...

Page 15: ...ports the USB 3 2 specification Use this port for USB devices such as a USB keyboard mouse USB printer USB flash drive etc 7 10 100 1000 Server Management LAN Port The LAN port provides Internet conne...

Page 16: ...straight out from the connector Do not rock it side to side to prevent an electrical short inside the cable connector ID button LED 10 100 1000 LAN LED State Description Yellow On 1Gbps data rate Gree...

Page 17: ...the power outlet to prevent damage to the devices After installing the device and before turning on the computer make sure the device cable has been securely attached to the connector on the motherbo...

Page 18: ...power connector mainly supplies power to the CPU If the 12V power connector is not connected the computer will not start To meet expansion requirements it is recommended that a power supply that can w...

Page 19: ...n When connecting a fan cable be sure to connect it in the correct orientation the black connector wire is the ground wire The motherboard supports CPU fan speed control which requires the use of a CP...

Page 20: ...or header can provide two USB ports via an optional USB bracket For purchasing the optional USB bracket please contact the local dealer Pin No Definition Pin No Definition 1 Power 11 IntA_P2_D 2 IntA_...

Page 21: ...dby 3 No Pin 4 ID LED 5 Power LED 6 ID LED 7 HDD LED 8 System Status LED 9 HDD LED 10 System Status LED 11 Power Button 12 LAN1 Active LED 13 GND 14 LAN1 Link LED 15 Reset Button 16 SMBus Data 17 GND...

Page 22: ...DA 20 I2C_DEV_RST 21 PH_HP_SCL0 22 GND 23 PH_HP_SDA0 24 GND 25 PH_HP_SCL1 26 GND 27 PH_HP_SDA1 28 GND 15 P3V3_AUX 30 P3V3_AUX 29 30 2 1 13 TPM1 Trusted Platform Module Connector Trusted Platform Modul...

Page 23: ...rm Management Interface Specification IPMI messages between intelligent I2C devices 4 1 Pin No Definition 1 Clock 2 GND 3 Data 4 VCC 15 CN_NCSI NCSI Connector Pin No Definition Pin No Definition 1 NCS...

Page 24: ...our computer and unplug the power cord before replacing the battery Replace the battery with an equivalent one Danger of explosion if the battery is replaced with an incorrect model Contact the place...

Page 25: ...Normal operation Default 2 3 Clear CMOS data S3 Power On Select 1 2 Keep initial power on Default 2 3 Stop initial power on when BMC is not ready Clear CMOS CLR_CMOS Enable Default 3 2 1 S3 Power On...

Page 26: ...with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected re...

Page 27: ...f the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to...

Page 28: ...displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen H...

Page 29: ...ocessor Information CPU Brand String CPU Brand String CPU Speed Processor Core Microcode Patch Displays the technical specifications for the installed processor s Memory Information Total Memory Note2...

Page 30: ...Description AGESA PI Version PI Version Displays AGESA PI version information Onboard LAN Information LAN MAC Address Note3 Displays LAN MAC address information System Date Sets the date following th...

Page 31: ...OS Setup 2 2 Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu s...

Page 32: ...not be available Options available Enable Disable Default setting is Enable SPI TPM Support Enable Disable SPI TPM Support Options available Enable Disable Default setting is Disable Active PCR banks...

Page 33: ...storage hierarchy Options available Enabled Disabled Default setting is Enabled Endorsement Hierarchy Enable Disable endorsement hierarchy Options available Enabled Disabled Default setting is Enable...

Page 34: ...2 2 AST2600 Super IO Configuration Parameter Description AST2600 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Configuration Press Enter for configuration o...

Page 35: ...ble Enabled Disabled Default setting is Enabled Devices Settings Note2 Displays the Serial Port 1 device settings Change Settings Note2 Select an optimal settings for Super IO Device Options available...

Page 36: ...Settings Parameter Description Wake System from S5 Enable Disable system wake on alarm event Options available Disabled Fixed Time When Fixed Time is selected system will wake on the hr min sec speci...

Page 37: ...ver LAN Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN Console Redirection is set to Enabled Terminal Type Se...

Page 38: ...s 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty...

Page 39: ...sole Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting...

Page 40: ...ata loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the...

Page 41: ...AGESA Version Displays the AGESA version information SVM Mode Enable Disable the CPU Virtualization Options available Enabled Disabled Default setting is Enabled SMM Lock Enable Disable the CPU Lock...

Page 42: ...42 BIOS Setup 2 2 6 AMI Graphic Output Protocol Policy Parameter Description ASPEED Graphics PCI Adapter ASPEED Graphics Driver Output Select Selects Monitor Output by Graphic Output Protocol...

Page 43: ...43 BIOS Setup 2 2 7 PCI Subsystem Settings...

Page 44: ...ces Options available Enabled Disabled Default setting is Enabled Onboard LAN I O ROM Note3 Enable Disable the onboard LAN devices and initializes device expansion ROM Options available Enabled Disabl...

Page 45: ...nnected DISABLE option will keep USB devices available only for EFI applications Options available Auto Enabled Disabled Default setting is Enabled XHCI Hand off Enable Disable the XHCI USB 3 0 Hand o...

Page 46: ...evice reset time out Selects the time out value during a USB mass storage device reset Options available 10 sec 20 sec 30 sec 40 sec Default setting is 20 sec Device power up delay Maximum time the de...

Page 47: ...he Ipv4 HTTP feature Options available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enab...

Page 48: ...48 BIOS Setup 2 2 10 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system...

Page 49: ...49 BIOS Setup 2 2 11 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type...

Page 50: ...50 BIOS Setup 2 2 12 AMD Mem Configuration Status Parameter Description CPU Press Enter to view the memory configuration status related to CPU...

Page 51: ...iguration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit...

Page 52: ...sing keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Commit Changes and Exit Host iSCSI Configuration Press Enter to configure advanced items...

Page 53: ...53 BIOS Setup 2 2 15 Intel R I210 Gigabit Network Connection...

Page 54: ...e numeric keys to adjust desired values up to 15 seconds UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for th...

Page 55: ...55 BIOS Setup 2 2 16 Intel X550 10GBASE T Network Connection...

Page 56: ...o 15 seconds UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name D...

Page 57: ...g VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrea...

Page 58: ...ote Options available Enabled Disabled Default setting is Disabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gatew...

Page 59: ...for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consecutive Neighbor solicitation messages sent while performing Duplicate Address Detection on a...

Page 60: ...tup 2 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related sub...

Page 61: ...e Disable CPU Watchdog Timer Options available Auto Enabled Disabled Default setting is Auto Core Watchdog Timer Interval Note Specifies the CPU Watchdog Timer interval Default setting is Auto Core Wa...

Page 62: ...ntrol Space limit control for SEV ES ASIDs Options available Auto Manual Default setting is Auto Streaming Stores Control Enable Disable the Streaming Stores functionality Options available Auto Enabl...

Page 63: ...isabled Default setting is Auto Redirect scrubber control Enable Disable the Redirect scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber limit S...

Page 64: ...ilable Auto Enabled Disabled Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Auto Manual Default setting is Auto ACPI SLIT remote re...

Page 65: ...c Flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Freeze DF module queues on error Options available Auto Enabled Disabled Default setting is Au...

Page 66: ...Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced...

Page 67: ...tings Options available Auto Enabled Default setting is Auto DRAM Controller Configuration Press Enter for configuration of advanced items DRAM Power Options Power Down Enable Enable Disable DDR power...

Page 68: ...t Package Repair function Options available Enable Disable Default Default setting is Default RCD Parity Enable Disable the RCD Parity function Options available Auto Enabled Disabled Default setting...

Page 69: ...tion Press Enter for configuration of advanced items PMU Training DFE Read Training Perform 2D Read Training with DFE on Options available Auto Enable Disable Default setting is Auto FFE Write Trainin...

Page 70: ...No help string Options available Auto Enabled Disabled Default setting is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Auto Enabled Disabled Default setting is Auto Address...

Page 71: ...71 BIOS Setup 2 3 3 3 NVDIMM Parameter Description NVDIMM Displays the information of the devices controllers if installed...

Page 72: ...Mode Default setting is Auto MBIST Aggressors Note Enable Disable MBIST Aggressor test Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting Note Enable Dis...

Page 73: ...tatic Lane Control function Options available Enabled Disabled Default setting is Disabled Target Static Lane Select Upper 32 bits Note2 Target Static Lane Select Lower 32 bits Note2 Target Static Lan...

Page 74: ...ault setting is Auto PCIe ARI Enumeration ARI Forwarding Enable for each downstream port Options available Auto Enable Disable Default setting is Auto PCIe Ten Bit Tag Support Enable Disable PCIe ten...

Page 75: ...s Auto NBIO LCLK DPM Press Enter for configuration of advanced items NBIO DPM Control This setting controls how the NBIO Power Management is controlled Options available Auto Manual Default setting is...

Page 76: ...s the timer interval of the SYSHUB Watchdog timer in milliseconds SLINK Read Response OK This item specifies whether SLINK read response errors are converted to an Okay response Options available Enab...

Page 77: ...tions available Auto OR AND Default setting is Auto Preferred IO Preferred IO select type Manual Bus Number manually Auto Default Options available Auto Manual Default setting is Auto CV test Enable D...

Page 78: ...configuration of advanced items AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is Last State FCH RAS Options Press Enter for configu...

Page 79: ...Console Out Control Note Enable Disable the Basic ConsoleOut function for ABL Options available Auto Enable Disable Default setting is Auto ABL PMU message Control Note To Control the total number of...

Page 80: ...for configuration of advanced items Chipset SATA0 1 Enable Note Enable Disable Bixby SATA controller Options available Auto Enabled Disabled Default setting is Auto Chipset SATA Mode Select Bixby SAT...

Page 81: ...uring the function of AMD PBS Select a submenu item then press Enter to access the related submenu screen Parameter Description RAS Press Enter for configuration of advanced items NVMe RAID mode Enabl...

Page 82: ...Period GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for unc...

Page 83: ...the PCIe AER Uncorrected Error Severity register of PCIe device CCIX GHES Deferred ERR Notify Type Selects the Notification type for CCIX deferred error Options available Polled SCI Default setting is...

Page 84: ...hen press Enter to access the related submenu screen Parameter Description Onboard Audio Enable Disable Onboard Audio Options available Enabled Disabled Default setting is Enabled Program All VR Enabl...

Page 85: ...ve 4GB MMIO Limit to 38 43 bits limit This option works only when Above 4G decoding is enabled Options available 40bit 1TB 41bit 2TB 42bit 4TB 43bit 8TB Default setting is 43bit 8TB Memory Information...

Page 86: ...Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Note2 Configures OS Watchdog Timer Options available 5 minutes 10 mi...

Page 87: ...e advanced items View FRU Information Press Enter to view the FRU information BMC VLAN Configuration Press Enter to configure advanced items BMC network configuration Press Enter to configure advanced...

Page 88: ...se options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Eras...

Page 89: ...Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends...

Page 90: ...ets VLAN ID for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 BMC VLAN Priority Sets 802 1Q Priority for a new VLAN or an e...

Page 91: ...DynamicBmcDhcp Default setting is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digita...

Page 92: ...network during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by...

Page 93: ...l settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user...

Page 94: ...tions that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not be...

Page 95: ...e Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Update Append...

Page 96: ...Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is Off Quiet Boot Enable Disable showing the...

Page 97: ...re the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Ent...

Page 98: ...e BIOS setup Options available Yes No Save Changes Saves changes done so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BI...

Page 99: ...was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 2 10 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Ar...

Reviews: