background image

 

 

 

 

 

Installation Instructions

 

ELEKTROMAT 
ST 16.24-40,00

 

Model: 10002992 00024

 

 

 
 
 
 
 
 
 
 
 

 

-en- 

 

Status: 22.11.2019

 

 

 

Summary of Contents for ELEKTROMAT 00024

Page 1: ...f Installation Instructions ELEKTROMAT ST 16 24 40 00 Model 10002992 00024 en Status 22 11 2019...

Page 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Page 3: ...nection 11 7 Completing commissioning inspection 12 8 Declaration of incorporation Declaration of conformity 14 Symbols Warning Potential injury or danger to life Warning Danger to life from electric...

Page 4: ...be rendered null and void Safety information Installation and initial operation tasks are to be performed by skilled personnel only Only trained electrical craftsmen are permitted to work on electrica...

Page 5: ...actor cos 0 51 Maximum movement per hour 20 h 1 Class of protection IP 54 Limit switch range maximum revolutions of output shaft hollow shaft 20 Braking torque of magnetic brake 130 Nm Braking voltage...

Page 6: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...

Page 7: ...7 Mounting Four holes are provided for mounting BAGAD03301_Z002...

Page 8: ...installation be sure to use a lifting device that has a sufficient load carrying capacity Ensure that there is sufficient space around the handwheel for safe operation of the friction clutch The outp...

Page 9: ...n clutch The friction clutch provides overload protection It is tightened finger tight at the factory Turning to the right handwheel or screw increases the transferable torque Turning to the left deco...

Page 10: ...rgised Observe the applicable regulations and standards Make the electrical connection according to standard Use suitable tools Performing electrical installation Remove the cover Connect the motor ca...

Page 11: ...11 5 Motor connection G1 Half wave rectifier M1 Motor Y1 Magnetic brake 6 Limit switch connection F10 Thermal contact...

Page 12: ...ted Protect the output shaft permanently against corrosion Mounting Check that all connection elements consoles torque mounts screws locking rings etc are secure and in proper condition Electrical wir...

Page 13: ...t be observed In an environment that can affect the coefficient of friction of the brake pad atmosphere with oil solvents detergents etc class of protection IP65i must be adopted Note Engage a qualifi...

Page 14: ...complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The fo...

Page 15: ...15...

Page 16: ...16...

Reviews: