background image

SAVE THIS MANUAL FOR FUTURE REFERENCE

Register your Generac product at:

WWW.GENERAC.COM

1-888-GENERAC

(1-888-436-3722)

Owner’s Manual

Generac PWRcell™ Inverters

XVT076A03

XVT114G03

009954

(000209b)

WARNING

Loss of life. This product is not intended to 
be used in a critical life support application. 
Failure to adhere to this warning could result 
in death or serious injury.

Register your Generac product at:

https://pwrfleet.generac.com

1-888-GENERAC

(888-436-3722)

Para español, visita: 

http://www.generac.com/service-support/product-support-lookup

Pour le français, visiter: 

http://www.generac.com/service-support/product-support-lookup

Summary of Contents for PWRcell XVT076A03

Page 1: ...life This product is not intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury Register your Generac product at https pwrfleet generac com 1 888 GENERAC 888 436 3722 Para español visita http www generac com service support product support lookup Pour le français visiter http www generac com service support product suppo...

Page 2: ...ge See Serial Number Locations When contacting an Independent Authorized Service Dealer IASD or Generac Customer Service always supply the complete model number and serial number of the unit Table 1 Generac PWRcell Inverter Important Information Unit Model Number Unit Serial Number Date Purchased Commissioning Date 000393a WARNING CANCER AND REPRODUCTIVE HARM www P65Warnings ca gov ...

Page 3: ...ter LED 7 Internet LED 8 Shutdown Mode 8 System Modes Overview 8 Grid Tie 8 Clean Backup 9 Priority Backup 9 Self Supply 9 Self Supply Setpoints 10 Section 3 Operation 13 Operation and User Interface 13 Home Screen 13 Selecting System Modes 13 Device Pages 14 Enabling and Disabling Devices 14 Mod Settings Menu 15 Ethernet Configuration 17 Ethernet Setup 17 Serial Number and Registration 17 Other E...

Page 4: ...iv Owner s Manual for Generac PWRcell Inverter This page intentionally left blank ...

Page 5: ...on tags and decals affixed to the unit are not all inclusive If using a procedure work method or operating technique that the manufacturer does not spe cifically recommend verify that it is safe for others and does not render the equipment unsafe Throughout this publication and on tags and decals affixed to the unit DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special inst...

Page 6: ...matic start up Disconnect utility power and render unit inoperable before working on unit Failure to do so will result in death or serious injury WARNING Risk of injury Do not operate or service this machine if not fully alert Fatigue can impair the ability to service this equipment and could result in death or serious injury 000215 000209b WARNING Loss of life This product is not intended to be u...

Page 7: ...irst aid and get medical help Failure to do so will result in death or serious injury 000599 Electrocution Turn battery disconnect OFF and de energize REbus before touching terminals Failure to do so will result in death serious injury equipment and property damage DANGER 000152 DANGER Electrocution Verify electrical system is properly grounded before applying power Failure to do so will result in...

Page 8: ...Introduction and Safety 4 Owner s Manual for Generac PWRCell Inverter This page intentionally left blank ...

Page 9: ...ating AC 1 Operating voltage range AC XVT076A03 L N V rms 108 120 130 Operating voltage range AC XVT076A03 L L V rms 216 240 260 Operating voltage range AC XVT114G03 L N V rms 108 120 130 Operating output voltage range AC XVT114G03 L L V rms 184 208 228 Continuous output current AC grid tied A rms 32 PCS controlled current grid tied Arms 32 Continuous output current AC islanded A rms 42 Output fau...

Page 10: ...wer PWRcell inverters disconnect from the grid and provide AC power to support protected loads when configured to do so All PWRcell products use the REbus 380 VDC nanogrid to connect to each other The REbus nanogrid automates the flow of power to enable plug and play setup and operation of PWRcell equipment For more information about REbus visit www generac com In Figure 2 3 PWRcell inverter E is ...

Page 11: ...ific fault detected Inverter LED Inverter LED D communicates the status of the utility grid and or inverter through LED color and state Green utility is connected and within normal operational voltage and frequency Yellow utility grid is not within normal conditions and the inverter is in a waiting state User intervention typically is not required The inverter will restart as soon as the utility g...

Page 12: ...Modes Overview Generac PWRcell offers several system modes for various installation configurations markets and applications Connected REbus devices work together to manage the distribution of power based on the selected system mode Some modes interact with PWRcell batteries to store power and or balance production and consumption See Table 2 1 and Table 2 2 for an overview of available system mode...

Page 13: ...ar power is used to charge the battery When the available solar power is lower than the battery input power rating the inverter uses grid power to expedite battery charging See Figure 2 8 If solar and grid power are available both can charge the battery The system displays the amount of power being drawn from the grid and the amount of power being consumed by local loads before reaching the batter...

Page 14: ... Self Supply mode only and are only used for specific applications See Table 2 3 Self Supply Setpoints 009962 009963 011241 Table 2 3 Self Supply Setpoints Setpoint Description Default Units TargMaxImprtP Target Maximum Import Power Maximum power imported from the grid at any point When the overall building load exceeds this setpoint the inverter will supply additional power from the battery and s...

Page 15: ...information on CT calibration see the PWRcell Inverter Installation Manual NOTE This feature is NOT intended to serve as a means of achieving compliance to Utility interconnection requirements For information on export limiting settings related to Utility compliance see the PWRcell Inverter Installation Manual When enabled Export Override allows the user to restrict inverter export such that exces...

Page 16: ...12 Owner s Manual for Generac PWRcell Inverter General Information This page intentionally left blank ...

Page 17: ...he current system mode is displayed at the top of the screen Figure 3 2 Home Screen Selecting System Modes Once a system is installed a system mode that best suits the user s needs must be set Once set the system remains in that mode without needing to be changed NOTE A system mode can be changed at any time To select a system mode 1 See Figure 3 3 While viewing the home screen press the center bu...

Page 18: ... enabled by the user before the device will operate If a device is disabled the device will remain in a disabled state and will not resume operation until enabled by the user Once enabled if grid power is present the inverter will create DC voltage establishing the REbus nanogrid All devices connected to REbus will wake up and begin communications To enable a device 1 Use the right arrow key to sc...

Page 19: ...r button to select Figure 3 11 Internet Device Page NOTE After selecting Mod Settings it may take a moment for the settings to load 3 See Figure 3 12 Use the up and down arrows to scroll through available settings 4 Highlight the desired setting and press the center button to select 5 Use the up and down arrow keys to adjust the value of the setting NOTE Press the center button to deselect a setti...

Page 20: ...ding backup power during a grid outage EnaExtTransfer on or off off Turn on if an external automatic transfer switch ATS has been installed to operate with the Inverter ExtTransVolt 50 0 200 0 95 Minimum voltage from the utility that must be present for the inverter to reconnect an ATS back to the grid ExtTransTime 1 360 Seconds 15 Length of time the inverter will wait to trigger an ATS to reconne...

Page 21: ...e can be monitored from the PWRview online monitoring system and mobile app To register a system for PWRview monitoring 1 See Figure 3 13 Locate the serial number and registration code on the registration decal on the front of the inverter This information will be required for registration 2 Navigate to https pwrfleet generac com or if using a mobile device scan the registration label QR code 3 Fo...

Page 22: ...Operation 18 Owner s Manual for Generac PWRCell Inverter This page intentionally left blank ...

Page 23: ...vent B are clear at all times Cleaning Intake Filter See Figure 4 1 Clean intake filter A with a soft brush or vacuum cleaner If air filter is damaged or becomes difficult to clean contact the nearest Independent Authorized Service Dealer IASD or Generac Customer Service at 1 888 GENERAC 1 888 436 3722 or visit www generac com for a replacement filter Figure 4 1 Intake Vent and Exhaust Vent Recove...

Page 24: ...rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290 Hwy 59 Waukesha WI 53189 1 888 GENERAC 1 888 436 3722 www generac com ...

Reviews: