background image

GE Consumer  Industrial
Electrical Distribution

Project Name:

Sludge Dewatering and Odor Control at Plant 1
Project No. P1-101

Specification:

Revision:  0

02/01/2016

16340
Medium Voltage Switchgear

 

Volume 1 of 

3

Equipment Tag(s):

Shop Order

SWITCHGEAR SWGR-Q-A ( 15LSWGR901 )

111027-01

SWITCHGEAR SWGR-Q-B ( 15LSWGR902 )

111027-04

Manufacturer:

General Electric / Powell BPD

Address:

12305 Kurland Drive

City, State, Zip

Houston, TX  77034

Website:

www.geindustrial.com

GE Base Requisition #:

480-Z7612

Local Service Representative:

GE Energ- Engineering Services

Address:

3601 East LaPalma Ave.

City, State, Zip

Anaheim, CA  92806-2119

Phone:

888-GE4-SERV or 540-387-8617

Website:

www.geindustrial.com

Operation & Maintenance Manuals

g

imagination at work

Summary of Contents for Multilin 350

Page 1: ...GR901 111027 01 SWITCHGEAR SWGR Q B 15LSWGR902 111027 04 Manufacturer General Electric Powell BPD Address 12305 Kurland Drive City State Zip Houston TX 77034 Website www geindustrial com GE Base Requi...

Page 2: ...16340 Project No P1 101 Medium Voltage Switchgear Designation Loop Tag Shop Order SWITCHGEAR SWGR Q A 15LSWGR901 111027 01 SWITCHGEAR SWGR Q B 15LSWGR902 111027 04 12 47KV SERVICE CENTER ADDITIONS 111...

Page 3: ...Sludge Dewatering and Odor Control at Plant 1 Specification 16340 Project No P1 101 Medium Voltage Switchgear Tab 1 Device Data Sheets Key Components...

Page 4: ...ject No P1 101 Medium Voltage Switchgear Drawing Manufacturer Catalog Number Reference Mark Loop Tag GE Multilin 350 E P5 G5 H E S N N 1E D N 350 15LITG901 15LITG903 15LITG907 15LITG911 15LITG902 15LI...

Page 5: ...PROTECTION SYSTEM Intuitive and Innovative Feeder Protection Multilin Easy to use and intuitive overcurrent protection and control for feeder applications Effortless draw out construction eliminates...

Page 6: ...Easy to Use Drawout Construction The 350 offers a complete drawout feature eliminating the need for rewiring after testing has been concluded The withdrawable feature also eliminates the need to open...

Page 7: ...ng HALT where it undergoes extreme operating conditions The robust 350 design ensures long term operation Reduced Life Cycle Cost The 350 is designed to reduce total installation and life cycle cost f...

Page 8: ...selectable time delay In the event of a breaker failure the 350 will issue an additional signal to trip the breakers connected to the same busbar or signal the trip of upstream breakers Autoreclose Re...

Page 9: ...and includes the metered values at the moment of the event Oscillography Transient Fault Recorder The 350 captures current and voltage waveforms and digital channels at 32 samples per cycle Multiple r...

Page 10: ...rol With the implementation of the Password Security feature in the 350 relay extra measures have been taken to ensure unauthorized changes are not made to the relay When password security is enabled...

Page 11: ...Once the information is entered the simplified setup will generate a settings file provide documentation indicating which settings are enabled and an explanation of the parameters entered Viewpoint M...

Page 12: ...S485 IRIG B F1 F2 COMMUNICATIONS CONTROL POWER A B C FEEDER BUS Vts 52 E5 D5 E6 D6 E7 D7 E8 D8 IA IA IB IB IC IC IG IG FEEDER Cts CONNECT AUX_VT AS REQUIRED VOLTAGE INPUTS WYE VT CONNECTION E9 D9 E10D...

Page 13: ...ONT PORT Electrically isolated front USB communication port Front Rear Top Side SETPOINT GROUP 1 2 These indicators are continuously on if corresponding group provides settings for protection elements...

Page 14: ...s outage time 5 min AMBIENT TEMPERATURE High Temperature Pickup 20 C to 80 C in steps of 1 C Low Temperature Pickup 40 C to 20 C in steps of 1 C Time Delay 1 to 60 min in steps of 1 min 50 ms outage t...

Page 15: ...DNP 3 0 IEC 60870 5 103 ETHERNET COPPER Modes 10 100 MB auto detect Connector RJ 45 Protocol Modbus TCP IP DNP 3 0 IEC 60870 5 104 IEC 61850 GOOSE USB Standard specification Compliant with USB 2 0 Dat...

Page 16: ...Standard faceplate LCD full menu actual values and setpoints with 10 Inputs 7 Outputs 2 Form A 5 Form C Current Protection S Standard Overcurrent Protection 50P 1 50G 1 50N 1 51P 1 51G 1 51N 1 E Exten...

Page 17: ...KV 40KA 1 1200A RATING A RETROFIT CODE NONE 1 REVISION 1 A NO CAP SWITCHING 2 5 CYCLE BKR A 60 HZ RATING 2 125VDC CLOSE COIL STANDARD WIRING 2 125VDC TRIP COIL 1ST 0 NO 2ND TRIP COIL 2 125VDC CHARGING...

Page 18: ...KV 40KA 1 1200A RATING A RETROFIT CODE NONE 1 REVISION 1 A NO CAP SWITCHING 2 5 CYCLE BKR A 60 HZ RATING 2 125VDC CLOSE COIL STANDARD WIRING 2 125VDC TRIP COIL 1ST 0 NO 2ND TRIP COIL 2 125VDC CHARGING...

Page 19: ...R VAC EQUIPMENT BREAKER Y 15 0KV 50KA 1 1200A RATING J RETROFIT CODE 13 8kV 750MVA 77kA C L 1 REVISION 1 A NO CAP SWITCHING 2 5 CYCLE BKR A 60 HZ RATING 2 125VDC CLOSE COIL STANDARD WIRING 2 125VDC TR...

Page 20: ...and Odor Control at Plant 1 Specification 16340 Project No P1 101 Medium Voltage Switchgear Manufacturer Catalog Number Drawing Reference Mark Basler BE1 27A3EE1JA1S3F BE1 27 Data Sheet Undervoltage...

Page 21: ...a wide range Instantaneous functions offer immediate response to extreme voltage conditions Individually adjustable definite short inverse medium inverse or long inverse timing for each time delayed u...

Page 22: ...Overvolt age Relay is well suited for these applications Ground Fault Detection In a three phase three wire system a single conductor may break or the insulation may deteriorate resulting in a high r...

Page 23: ...ions function together INPUTS Voltage Sensing A system voltage transformer with standard 120 240 Volt secondary supplies the Under Overvoltage Relay s input transformer with a single phase voltage fro...

Page 24: ...ge maintains the power supply status output relay in a continuously energized state with its output contact open If the power supply output voltage falls below the requirements of proper operation the...

Page 25: ...27 59 27 59 5 SPECIFICATIONS continued Figure 2 Inverse Timing Characteristic Curves LONG INVERSE UNDER LONG INVERSE OVER MEDIUM INVERSE UNDER MEDIUM INVERSE OVER SHORT INVERSE UNDER SHORT INVERSE OV...

Page 26: ...LEGEND When Option 2 is A or B the NC contacts associated with K6 terminals 14 and 15 are dedicated for the Power Supply Status Output When Option 2 is A or B the NC contacts associated with K4 termin...

Page 27: ...omplete Style Number BE1 27 Style No BE1 59 Style No BE1 27 59 Style No Complete the Style Number by selecting one feature from each column of the Style Number Identification Chart and entering its de...

Page 28: ...y None 2 NC relay None 3 NO relay NO relay 4 NC relay NC relay 5 SPDT relay None 6 SPDT relay SPDT relay 27 59 0 None None 1 NO relays None 2 NC relays None 3 NO relays NO relays 4 NC relays NC relays...

Page 29: ...lays GE Series RL RL4RA CXA TXA RX Current Transformers Phase CT ITI Model 780 780 CT 50GS ITI Model 143 143 500 CTGS Voltage Transformers ITI PTG5 PTG5 2 110 123FF LPT Test Switches Potential ITI FT...

Page 30: ...contacts Rated 600 V 20 A continuous 250 A for 3 seconds Palladium contacts for low level instrument circuits available Pull to lock and pull to turn actions available Up to 12 positions 360 rotation...

Page 31: ...ax 12 positions 2 standard S 180 rotation max 7 positions 3 target T mechanically operated shows last operated position on the switch when the handle is turned to the left 45 posi tion a green target...

Page 32: ...ailable with electric reset capability Available with built in coil monitoring and fault signal detection indication HIGH SPEED Transition times of less than 8mSec less than 1 2 cycle are standard SAF...

Page 33: ...Contact ratings for LOR SERIES 24 LOCK OUT RELAYS Basic LOR Deck Layout 125VDC 250VDC 120VAC 240VAC 480VAC 600VAC 5 3 20 15 7 5 6 2 1 20 10 5 5 Short Time Rating AMPS Continuous Rating AMPS 60 60 60 6...

Page 34: ...til the LOR SR contacts reclose The Electric Reset LOR is tripped by the same method as the Manual Reset LOR In the Trip posi tion closing S2 operates relay K1 which closes relay contact K1 The curren...

Page 35: ...F Nominal Voltage 24VDC 48VDC 125VDC 250VDC Normal Voltage Operating Range 19 2 to 28VDC 38 4 to 57 6VDC 100 to 150VDC 200 to 275VDC RESET COIL VOLTAGE DATA COIL BURDEN DATA A B C D E F G H K 24VDC 24...

Page 36: ...INFORMATION Self Reset LOR SR Model 78 LOR Trip Coil D E F G Available for Std Trip LOR SR D E F Available for Hi Spd Trip LOR SR No of Decks 3 3 5 5 7 7 time delay units only 8 8 instant reset units...

Page 37: ...OLOGY Q Q All infrared windows from Fluke use the unique Quadraband multispectral optic allowing inspection with any camera for total exibility both now and in the future s Engineered and tested to wi...

Page 38: ...ANSI C37 20 7 50 kA for 30 cycles 60 Hz EEMACS 14 1 Type B 40 kA for 30 cycles 60 Hz ASTA Arc Testing IEC 62271 20 kA for 5 cycles 50 Hz TUV Cyclic humidity withstand Yes Vibration withstand Yes NEMKO...

Page 39: ...out written permission from Fluke Corporation Included with product IR Windows are supplied complete assembled and ready for installation In addition to the IR Window each carton contains an installat...

Page 40: ...replace the asterisk with the appropriate digit from the shaded area in the Coil Selection table Additional coil information is shown in the Coil Data table Coil Selection Coil Data REFERENCES Standa...

Page 41: ...er if used D Mechanical Latch if used E Transient Voltage Suppressor Add 1 2 inch for electrical clearance to enclosure Engineering Outline Drawings AC Control Relay 55 215782 DC Control Relay 55 2158...

Page 42: ...300 5 C20 0 3 0 6 0 6 1 2 2 4 780 401 400 5 C50 0 3 0 3 0 6 0 6 1 2 780 501 500 5 C50 0 3 0 3 0 3 0 6 0 6 780 601 600 5 C100 0 3 0 3 0 3 0 3 0 6 780 751 750 5 C100 0 3 0 3 0 3 0 3 0 6 780 801 800 5 C...

Page 43: ...atin America Tel 1 800 547 8629 Fax 1 905 201 2455 e mail sales multilin ge com Europe Middle East Africa Tel 34 94 485 88 00 Fax 34 94 485 88 45 e mail gemultilin euro ge com Please refer to our webs...

Page 44: ...0 161 2 0 2 0 143 251 250 5 C50 0 3 0 3 0 6 1 2 2 4 0 175 2 0 2 0 143 301 300 5 C100 0 3 0 3 0 3 0 6 1 2 0 241 2 0 2 0 143 401 400 5 C100 0 3 0 3 0 3 0 3 0 6 0 322 2 0 2 0 143 501 500 5 C100 0 3 0 3 0...

Page 45: ...erica Tel 1 800 547 8629 Fax 1 905 201 2455 e mail sales multilin ge com Europe Middle East Africa Tel 34 94 485 88 00 Fax 34 94 485 88 45 e mail gemultilin euro ge com Please refer to our website www...

Page 46: ...G5 2 110 113FF PTG5 2 110 113CC PTG5 2 110 113SS 2 12000 100 1 120 PTG5 2 110 123 PTG5 2 110 123FF PTG5 2 110 123CC PTG5 2 110 123SS 2 13200 110 1 120 PTG5 2 110 1322 PTG5 2 110 1322FF PTG5 2 110 1322...

Page 47: ...age should not exceed 110 of rated value b Voltage transformers connected line to ground cannot be considered to be grounding transformers and must not be operated with the secondaries in closed delta...

Page 48: ...a variety of different arrangements to match customer requirements FT Test plugs are used in conjunction with the FT Switches to enable easy measurement calibration verification or maintenance of rela...

Page 49: ...ll length clear cover and can be sealed with a meter seal Fasteners Captive fasteners are made of molded plastic with a threaded brass insert for easy cover installation and removal Switch Poles FT Sw...

Page 50: ...errupting or short circuiting the circuit Only the current test switches with the current jack must be opened before inserting the Series Test Plug Connections to the test plug must be made before ins...

Page 51: ...ailable See page 11 Note Some functions will require more than one slot in the switch body Step 2 Optional If a tie bar is required then check this box and draw a dark heavy line over the poles to be...

Page 52: ...Panel Height ref pg 7 2 2 rack unit centered 3 3 rack unit centered X 3 rack unit low H 3 rack unit high 4 4 rack unit low 5 4 rack unit centered 6 4 rack unit high Color ANSI 61 G ANSI 70 A Brush Al...

Page 53: ...Test Switches www GEDigitalEnergy com Dimensional Drawing Type FT Test Switch Black cover and threaded stud terminals Clear cover and screw terminals Typical FT Switch Connection Schematic using an FT...

Page 54: ...C P P C P P C C C C C C C P C P P C P P C C C P P P P C C P P C C C C C C C P P C C P P C C P C P C C C C P C P P C P P C C P P P P C P C C C P C P C C L C P C C C C C C C P P P C P C C C C C C C C SW...

Page 55: ...0 0 Y Y Y Y Y Y Y Y Y Y 10 1 9 P C C C C C C C C C P P P 0 0 1 0 1 P T T T T T T 10 10 0 P P T T T T T T T T Y O 0 0 1 0 1 Y Y Y Y O O O O 5 1 4 C C P C C 10 6 4 C 10 6 4 P C C C T P P P T P 10 4 6 T...

Page 56: ...x 905 201 2098 email gemultilin ge com Europe Middle East Africa Avenida Pinoa 10 48170 Zamudio Vizcaya Spain Tel 34 94 485 88 00 Fax 34 94 485 88 45 email gemultilin euro ge com Asia Floor22 24 No 90...

Page 57: ...ion E stops and Self Monitoring contact blocks This legacy of leadership continues with the introduction of the Universal LED illumination solution Universal LED System Advantages Accepts 12 130V AC D...

Page 58: ...V AC 50 60 Hz 26 240V AC 50 60 Hz 46 460V AC 50 60 Hz 56 600V AC 50 60 Hz Dual Input 16 120V AC 24 24V AC DC Universal LED System Components High Intensity LED Lamps for Transformer Type Devices Pilot...

Page 59: ......

Page 60: ...LONG BARREL TYPES YA 2N YA 2TC YA 4N UL LISTED 90 C 600 VOLT TO 35 KV ELECTRO TIN PLATED CABLE ACCOMMODATION CRIMP DIE AND COLOR CODE INFORMATION NO INSPECTION WINDOW BEVELED ENTRY T T T B B B 90 L 4...

Page 61: ...IP20 Finger Safe touch safe Optional Visual Blown Fuse Indicator Lights DIN rail Mounting Compact Footprint Quick Tool free Easy Fuse Change Outs Applications All circuits up to 600 volts for motors c...

Page 62: ...CC UltraSafe Fuse Holder 4 USCC3N USCC3IN 3 Pole N Class CC UltraSafe Fuse Holder 4 Special Indicator Versions USCC1I AC120 USCC1I with 120VAC indicator 120 1 USCC1I AC300 USCC1I with 300VAC indicato...

Page 63: ...lay is not required Not for Branch Circuit Protection HIGHLIGHTS Fast Acting 250VAC Rated UL Listed to Standard 248 14 file E33925 CSA Certified to Standard C22 2 No 248 14 Approvals Melting Time Curr...

Page 64: ...00kA interrupting rating These ratings give the ATM a wide range of applications not covered by other midget fuses In addition ratings of 30 35 30 40 and 30 50 amperes are offered for specific applica...

Page 65: ...rrent Capability l Excellent Protective Characteris tics l Light weight l High Durability l Excellent Temporary Overvoltage and Surge Duty Capabilities l Superior Contamination Perfor mance l Designed...

Page 66: ...8 5 0 6 7 1 3 9 6 0 6 7 1 3 9 6 0 0 1 2 2 4 0 1 3 2 9 0 1 4 2 9 0 1 4 2 2 2 1 7 2 7 2 1 8 2 7 2 1 8 2 3 6 1 6 3 3 6 1 6 3 8 6 1 7 3 8 6 1 7 3 4 0 2 5 4 8 0 2 6 4 4 0 2 5 4 8 0 2 7 4 3 1 2 5 5 9 4 2 6...

Page 67: ...ge Switchgear Supporting Information Power Vac Switchgear Vacuum Circuit Breakers DEA 398 Power Vac Circuit Breaker Characteristics ANSI C37 06 2000 Current Basis GET 6600G Page 3 3 Paint Process Fini...

Page 68: ...imagination at work GE Consumer Industrial Electrical Distribution Medium voltage switchgear for the full range of applications 4 76kV 38kV...

Page 69: ...arc resistant technology to allow us to meet the increasingly demanding requirements of medium voltage switchgear users The scope of the combined line is matched by the depth of the engineering and th...

Page 70: ...egate primary functions so that no live parts are exposed Safety interlocks are standard as are closed door racking and storage breaker position indicator and positively actuated safety shutters It me...

Page 71: ...s disconnects and mecha nisms are interchangeable The main bus compartment is completely isolated by 11 gauge metal barriers Bus bars insulated with high dielectric epoxy pass through track resistant...

Page 72: ...Equipment Rating Indoor Outdoor 4 76 8 25 15 KV Height in Depth in 1 2 High Breaker Vertical Section less breakers Auxiliary Vertical Section Height in Depth in 1 2 High Breaker Vertical Section less...

Page 73: ...ximum Voltage Divided by K kV rms Maximum Symmetrical Interrupting Capability and Short Time Current kA rms Closing and Latching Capability 2 7K times Rated Short Circuit Current kA Crest Low Frequenc...

Page 74: ...example breaker contacts must be open before the breaker can be moved to or from the CON NECT position A positive mechanical stop is provided when the breaker reaches the CONNECT or TEST DISCONNECT p...

Page 75: ...UPPORT A rugged high strength track resistant polyester glass support assem bly firmly positions and holds the interrupter and primary conductors while providing insulation to ground and be tween phas...

Page 76: ...out tray VT s are automatically grounded upon withdrawl tray provides isolation from primary connec tions E DRY TYPE CONTROL POWER TRANSFORMERS have molded epoxy resin insu lation and are mounted in...

Page 77: ...s 6 Easy Installation results because many founda tions that are smooth and level don t require embedded floor steel or grouting To reduce installation time equip ment can be lifted into place without...

Page 78: ...PV System 38 and Hipoxy 2000 are registered trademarks of Powell Industries GE Consumer Industrial 41 Woodford Avenue Plainville CT 06062 www geelectrical com 2007 General Electric Company DEA 398 04...

Page 79: ...1 Q51 15LFBK904 001 52B2 Q52 15LFBK908 001 52B3 Q53 15LFBK912 12 47KV SERVICE CENTER ADDITIONS 1110270201 B 110B 15LFBK902 Note 1 Equipment Designation Volume Tab SWITCHGEAR SWGR Q A 15LSWGR901 1 6 SW...

Page 80: ...ated Interrupting Time Cycles 36 2 Sec Short time Current Carrying Capability kA 36 95 95 2 2 2 Typical System Operating Voltages kV Peak Close and Latch 2 6K x short circuit current rating kA Rated M...

Page 81: ...VEYED THROUGH A STAGE PRETREATMENT SPRAY WASHER FOLLOWED BY A GAS lRED DRYING OVEN AND THEN ALLOWED TO COOL PRIOR TO POWDER COATING 0RETREATMENT 3TEPS P s LEANING WITH A 0OTASSIUM YDROXIDE CLEANER FOR...

Page 82: ...HE ROOM ARE CONVEYED lRST THROUGH AN AUTOMATED POWDER COATING BOOTH WHERE POWDER IS APPLIED BY AUTOMATIC SPRAY GUNS EXT THE PARTS TRAVEL THROUGH A MANUAL POWDER COATING BOOTH WHERE AN OPERATOR INSPECT...

Page 83: ...quipment natural frequency 5 1 Hz Qualified by shake table testing Wyle Laboratories Nov 2005 THIS IS TO CERTIFY THAT THE ABOVE NAMED EQUIPMENT MEETS OR EXCEEDS ALL OF THE ABOVE REQUIREMENTS ACCORDING...

Page 84: ...orm 480 Z7612 16340 MSF 1 3 Operation Supplemental Operational Information 480 Z7612 16340 SOI 1 3A Instruction Manuals Medium Voltage Switchgear 2 3B Instruction Manuals Communication Devices 2 3C In...

Page 85: ...art Number Vendor Breaker Mechanism Grease 0282A2048P009 Mobil Alternative Lubricants None Use Specified Lubricant Estimated Yearly Quantities Part Number Qty 0282A2048P009 1 Lubrication References Pu...

Page 86: ...ication drawing listed below for operation of the following Device System Publication Drawing Vol Tab Medium Voltage Switchgear GEK 39672 Page 36 1 3A Medium Voltage Breakers 01 4IB 66000A Chapter 3 1...

Page 87: ...l Tab SWITCHGEAR SWGR Q A 15LSWGR901 System Voltage 12470V 3 4A Phase 3P3W kA Rating 40kA Main Bus 1200A Control Power 125VDC SWITCHGEAR SWGR Q B 15LSWGR902 System Voltage 12470V 3 4B Phase 3P3W kA Ra...

Page 88: ...ADDITIONS 111027 01 Description Publication Instructions Power Vac Metal Clad Switchgear GEK 39672 Rev G Instruction Manual Power Vac Vacuum Circuit Breakers 01 4IB 66000A Rev 11 2012 Users Guide GE...

Page 89: ......

Page 90: ......

Page 91: ......

Page 92: ......

Page 93: ...equipment not...

Page 94: ......

Page 95: ...the Fig 3 89184386...

Page 96: ...Fig 5 0209B4678 Rev 0 Fig 5 0209B4645 Rev 0...

Page 97: ...Figs...

Page 98: ...charge...

Page 99: ......

Page 100: ......

Page 101: ...Fig 7 0209B4649 1 Rev 1...

Page 102: ......

Page 103: ......

Page 104: ......

Page 105: ......

Page 106: ......

Page 107: ...copper and bushings...

Page 108: ......

Page 109: ...drawings particular...

Page 110: ......

Page 111: ......

Page 112: ......

Page 113: ......

Page 114: ......

Page 115: ......

Page 116: ......

Page 117: ......

Page 118: ......

Page 119: ......

Page 120: ...lower followed Fig 32...

Page 121: ......

Page 122: ...in against...

Page 123: ...ground sheath risers convenient...

Page 124: ...ground in...

Page 125: ......

Page 126: ...until it will be a...

Page 127: ...conductor DE APPARATUS THE FICE then...

Page 128: ...the Fig 40 891439D 1...

Page 129: ...MAKE THE FIG 42 891848...

Page 130: ...in...

Page 131: ...responsible policy Fig 45 8918438H...

Page 132: ...be enamel...

Page 133: ...sealer be this Fig 46 8042976...

Page 134: ......

Page 135: ...50 49...

Page 136: ...Fig 53 Fig 52 Fig 51 8043114...

Page 137: ...Fig 54...

Page 138: ...the instruction book in pages 28 to 32 Ground bus connections across shipping splits shall be made as specified in page 35 of the instruction book WARNING All primary and secondary circuit devices mus...

Page 139: ...wn above For such stacks remove the three taptites self threading bolts shown in Fig A 1 2 in the front upper compartment When these taptites are removed the barrier underneath shown in Fig 3 can be r...

Page 140: ...and A 1 4b for identification of barrier in a PT CPT rollout compartment Step 3 Remove vertical mid barrier in front upper compartment Remove the vertical mid barrier located in the lower part of the...

Page 141: ...steners Step 5a Remove inter unit bus supports Go directly to step 5b if polyester glass bus supports are provided a Apply strong adhesive tape so as to keep the two glastic supports together temporar...

Page 142: ...rts b When the eight bus support holes four holes for polyester glass bus supports are aligned replace the bus support assembly against the side sheet and use the 20 hardware to fasten the bus support...

Page 143: ...s should pass through a rubber bus cushion located inside the porcelain bus support If the rubber bus cushion falls off re insert the cushion on the busbar as shown in Fig A 1 9 and pass the busbar th...

Page 144: ...in step 5a for porcelain only c Ensure that no tools or other material is left behind in the bus compartment d Re assemble the vertical mid barriers and the horizontal pan that were removed in steps...

Page 145: ...witchgear by removing the rear bus barrier of the tie bus compartment Fig A 1 10 shows a typical bottom tie bus compartment with the rear bus barrier removed Fig A 1 10 Typical Rear tie bus compartmen...

Page 146: ...ng the roof and aisle sections are provided in the INSTALLATION section of this instruction book WARNING All primary and secondary circuit devices must be de energized and the primary circuit grounded...

Page 147: ...places in the front upper compartment and at two places in the front bottom compartment The 3 25 inch long bolts may be used where it is required to bolt through the red glastic sheet shown in the upp...

Page 148: ...ith at least one bolt in the front compartment and one bolt in the rear compartment c For 106 inch deep stacks a minimum of three bolts on each depth post with at least one bolt in the front compartme...

Page 149: ......

Page 150: ...62 Intentionally Left Blank...

Page 151: ...63 Intentionally Left Blank...

Page 152: ......

Page 153: ......

Page 154: ......

Page 155: ......

Page 156: ...6...

Page 157: ......

Page 158: ......

Page 159: ......

Page 160: ......

Page 161: ......

Page 162: ......

Page 163: ......

Page 164: ......

Page 165: ...GEK 105263B Instructions g Test Cabinet ______________________________________________________ for Power Vac Vacuum Circuit Breakers...

Page 166: ......

Page 167: ...ts Section 1 Introduction 1 1 Safety 3 1 2 Maintenance 3 Section 2 Receiving Handling Storage 2 1 Receiving 4 2 2 Handling 4 2 3 Storage 4 Section 3 Description Principals of Operation 4 Section 4 Ins...

Page 168: ...r Test Cabinet with 1 Trip Coil 7 4 Wiring Diagram for Test Cabinet with 2 Trip Coils 8 5 Wiring Diagram for Test Cabinet with 1 Trip Coil and 1 UVTD 9 THESE INSTRUCTIONS ARE INTENDED FOR USE BY QUALI...

Page 169: ...ion well planned and carried out consistent with both industry experience and manufacturer s recommendations Local environment must always be considered in such programs including such variables as am...

Page 170: ...condition Should the cabinet be stored under unfavorable atmospheric conditions it should be cleaned and dried out before being placed in service Section 3 Description and Principles of Operation The...

Page 171: ...CH 5 CLOSE PUSHBUTTON 6 TRIP COIL 1 PUSHBUTTON 7 TRIP COIL 2 OR UVTD PUSHBUTTON 8 INDICATING LIGHT w 250V resistor 9 125V INDICATING LIGHT RESISTOR 10 RECTIFIER BOARD 11 MOTOR CIRCUIT FUSE BLOCK 12 CL...

Page 172: ...are located on top accomodate wiring Refer to the wiring diagrams figures 2 3 and 4 for control power connections Section 5 Maintenance The contact surfaces of the coupler require periodic lubricatio...

Page 173: ...Power Vac Test Cabinet Section 5 Maintenance Fig 3 Test Cabinet Wiring Diagram for 1 Trip Coil 7...

Page 174: ...Fig 4 Test Cabinet Wiring Diagram for 2 Trip C 8...

Page 175: ...Fig 5 Test Cabinet Wiring Diagram for 1 Trip Coil UVTD 9...

Page 176: ...Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to the General Electric Company...

Page 177: ...GE CONSUMER INDUSTRIAL GE POWER VAC MANUAL GROUND AND TEST DEVICE Type PVV 1200 PVV 2000 PVV 3000 Instruction Number GEK 90212B...

Page 178: ...Description 4 5 Interlocks 6 5 1 Current Rating Interlock 6 5 2 Compartment Elevation Interlock 6 6 Indicators 6 6 1 Indicator Rods 6 6 2 Protective Shutter 6 7 Operating Procedures 7 8 Maintenance 8...

Page 179: ...2 SAFETY PRECAUTIONS The Manual Ground and Test Device and metal clad compartment have interlocks to prevent unsafe operation This device is often used during initial installation and for trouble sho...

Page 180: ...cover 13 Fig 2 supports the shutter 6 Fig 1 extension bar insulator 12 Fig 2 and the label system which indicates upper or lower compartment and bus or line load terminals A Ground terminal 5 Fig 1 is...

Page 181: ...ent Elevation Selector Lever 4 Compartment Elevation Interlock Mechanism 5 Ground Angle 6 Shutter 7 Labels LOAD LINE and BUS 8 Compartment Elevation Indicator 9 Shutter Retaining Screws Inside Front P...

Page 182: ...Indicator Rods Indicator rods 2 Fig 1 are provided at the front of the Manual Ground and Test Device to indicate when Connection Bars 1 2 3 Fig 2 are attached to the Extension Bars 5 Fig 2 The Indicat...

Page 183: ...ections to the Manual Ground and Test Device rack the device into the metal clad compartment This should be accomplished by using the Remote Racking Device 6 Test the exposed studs to make certain tha...

Page 184: ...n retaining pins in the indicating linkage These rings can be installed and removed with pair of pliers When they are installed on a pin there should be a maximum gap of 1 16 inch between the ears Reu...

Page 185: ...7 Racking Engagement Lever 8 Compartment Elevation Selector Lever 9 Nameplate 10 Ground Test Device Frame 11 Insulation Support 12 Extension Bar Insulator Tubes 13 Front Cover 14 Indicator Rods 15 Cur...

Page 186: ...10...

Page 187: ...11...

Page 188: ...rmation be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to the General Electric Company GE Consumer Industr...

Reviews: