Match

Uninterruptible Power Supply
2200 - 3000 VA

Manufactured by:

GE Digital Energy

General Electric Company 

Tel41 (0)91 / 850 51 51

CH – 6595 Riazzino (Locarno)

Fax

+41 (0)91 / 850 51 44

Switzerland

Website

www.gedigitalenergy.com

GE Digital Energy

Technology for the Digital World.

ver 2.0 - GB

Match UPS

g

Summary of Contents for Match

Page 1: ...anufactured by GE Digital Energy General Electric Company Telephone 41 0 91 850 51 51 CH 6595 Riazzino Locarno Fax 41 0 91 850 51 44 Switzerland Website www gedigitalenergy com GE Digital Energy Technology for the Digital World ver 2 0 GB Match UPS g ...

Page 2: ...vailable 3 2 Use Normal Operation 3 2 1 Normal operating conditions 3 2 2 Load indication 3 2 3 Auto off no load shutdown 3 2 4 Battery test 3 2 5 Switching off 3 3 Use Status and Alarm Indications 3 3 1 Charger on 3 3 2 Normal operation 3 3 3 AVR active 3 3 4 On battery 3 3 5 Battery low 3 3 6 Replace battery 3 3 7 Overload 3 3 8 High temperature 3 3 9 Programmed shutdown 4 COMMUNICATION 7 4 1 RS...

Page 3: ...hs if the storage temperature is within 20 and 45 C every month The shipment contains a Match UPS a battery pack one mains power cord two IEC male female output cords a data cable a CD ROM and this manual After unpacking inspect the UPS for damage If any damage is present please immediately notify the carrier and place of purchase IMPORTANT Before making any connection and switching on the UPS ple...

Page 4: ...imum AC current rating of each appliance outlet is 10Amps outlets 1 or 16Amps outlet 1a An output cord to connect a load to outlet 1a is not shipped with the unit See fig 3 3 Connect the mains power cord to the mains input socket 5 fig 1 of the UPS See fig 4 4 Connect the mains power cord to a working grounded AC wall socket outlet See fig 4 The green LED on 10 fig 6 will blink and after 30 second...

Page 5: ... discharging of the batteries is avoided The unit will automatically turn on again when mains power is restored The default setting of the no load shutdown function is activated You can change this setting through the RS232 port using the UPS configuration tool that came with the unit CD ROM see 6 3 Please note that if the UPS is not connected to the mains and the battery pack is disconnected from...

Page 6: ...mmediate action should be taken Indicators on front panel Situation on alarm avr progr shutd repl batt on batt buzzer o Charger on 3 3 1 o Normal operation 3 3 2 o Automatic voltage regulation 3 3 3 On battery 3 3 4 1x 8 s Battery low 3 3 5 1x s Replace battery 3 3 6 Overload 3 3 7 High temperature 3 3 8 1x s o Progr shutdown pending 3 3 9 o Progr shutdown in progress 3 3 9 Operating modes and cor...

Page 7: ...e battery The batteries are bad The alarm only stops after the next battery test if the batteries have been either sufficiently charged in case of discharged batteries or replaced by a new set in case of worn out batteries 3 3 7 Overload The demanded power of the equipment exceeds the UPS s rated output power If an overload persists during battery operation the UPS may shut down 3 3 8 High tempera...

Page 8: ...lay 5 Common 6 No function 7 No function 8 UPS connected 9 No function 4 2 Relay Interface Card option The card is equipped with potential free change over contacts for the following alarms general alarm mains failure battery low For more information please refer to the user manual that comes with the interface card 4 3 SNMP Interface Card option This card allows the data interface to be connected...

Page 9: ...Ce Box between the communication port of the UPS and a modem a programmed number can be dialed in case of a UPS alarm It also allows service personnel to dial in and check the status of the UPS to perform remote diagnostics This way service costs specially in remote areas can be reduced considerably 6 1 General The GE Digital Energy Match UPS is virtually maintenance free take care of proper envir...

Page 10: ... 2 2 Installation Connect line cord Dead socket outlet or mains voltage approx 187Vac or mains frequency out of tolerance Contact qualified electrician Battery start is possible see 3 1 2 UPS overtemperature Read 2 1 Allow UPS to cool down TCB tripped See above UPS will not switch on to normal operation LED on blinks Mains voltage between 140 187Vac Contact qualified electrician Batteries depleted...

Page 11: ...last detected frequency off factory 50 Hz Output frequency stability 0 1Hz battery operation Output waveform sine wave Power factor 0 7 Transfer time typical 4 ms Buck Boost voltage regulation at 140 305 V input voltage output voltage 190 254V Batteries ratings given for 25 C Nominal voltage Vdc 36 48 Number x capacity Ah of batteries 6x7 8x7 Type 12V sealed lead acid maintenance free Service life...