Page 1: ...e properly grounded ANTI TIP DEVICE WARNING Toreduce therisk of tipping the appliance must be secured by properly installed Anti Tip bracket packed with this appliance If the Anti Tip device supplied with the range does not fit this application use the universal Anti Tip device WB2X7909 WARNING All ranges can tip Injury to persons could result _ Install Anti Tip bracket packed with range See Insta...

Page 2: ...abinets installed above a cooktop must be no deeper than 13 Be sure your appliance is properly installed and grounded by a qualified technician Make sure the cabinets and wall coverings around the range can withstand the temperatures up to 200 F generated by the range MATERIALS YOU MAY NEED Tin Snips Lag Bolts Anchor Sleeves For Anti l p Bracket Mounted on Concrete Floors Only UL Approved 40 AMP 4...

Page 3: ... outlet must not be in this area NOTE Use a 4 power cord to prevent interference with the storage drawer Power cords 41 2to 6 long may have to be dressed to allow for proper drawer closing MINIMUM DIMENSIONS BETWEEN COOKTOP WALLS AND ABOVE THE COOKTOP Make sure the wall covering countertop flooring and cabinets around the range can withstand the heat up to 200 F generated by the range Allow 30 min...

Page 4: ...Park Quincy MA 02269 Effective January 1 1996 the National Electrical Code requires that new construction not existing utilize a 4 conductor connection to an electric range When installing an electric range in new construction follow Steps 3 and 5 for 4 wire connection You must use a 3 wire single phase A C 208Y 120 Volt or 240 120 Volt 60 hertz electrical system If the electrical service provided...

Page 5: ...e strain relief and tighten Allow enough slack to easily attach the cord terminals to the terminal block If tabs are present at the end of the winged strain relief they can be removed for better fit NOTE Do not install the power cord without a strain relief The strain relief bracket should be installed before reinstalling the rear range wiring cover Terminal ck Strain relief _ Power cord Bracket S...

Page 6: ...supply circuit must be connected to the neutral terminal located in the lower center of the terminal block The power leads must be connected to the lower left and the lower right terminals of the terminal block The 4th grounding lead must be connected to the frame of the range with the ground plate and the ground screw Remove the 3 lower terminal screws from the terminal block Remove the ground sc...

Page 7: ...ust conform to good wiring practices and local codes Skip to Step 8 and proceed with the installation 4 WIRE CONDUIT INSTALLATION Loosen the three lower terminal screws from the terminal block Remove the ground screw and ground plate and retain them Cut and discard the ground strap DO NOT DISCARD ANY SCREWS Before _ _ bl CkGround str_ Insert the ground bare wire tip between the range frame and the...

Page 8: ...ion of anti tip bracket attachment to wall WARNING Range must be secured by Anti Tip bracket supplied If the Anti Tip device supplied with the range does not fit this application use the universal Anti Tip device WB2X7909 See instructions to install supplied with bracket Unless properly installed the range could be tipped by stepping or sitting on the door Injury may result from spilled hot liquid...

Page 9: ...ve tape wire ties cardboard and protective plastic Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated Check to make sure that the door and drawer are parallel to each other and that both operate smoothly If they do not see the Owner s Manual for proper replacement Check to make sure that the rear leveling leg is ...

Page 10: ...Notes 10 ...

Page 11: ...Notes 11 ...

Page 12: ...Printed in the United States 12 ...