For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
geappliances.com or call GE Answer Center
®
service, 800.626.2000.
Specification Revised 2/11
221218
Electrical Requirements: 240v/208v; 60Hz, 40A
Effective January 1, 1996, the National Electrical
Code requires that new construction (not
existing) utilize a 4-conductor connection to an
electric range.
Receptacle Locations: Locally approved flexible
service cord or conduit must be used because
terminals are not accessible after range
installation. See shaded area in drawing for
location of electrical outlet box. Recommended
outlet locations allow range to be installed
directly against wall.
Note: 30" ranges conform to U.L. requirements
for 0" spacing from adjacent walls below
countertops. To reduce possibility of scorching
walls, engineering recommends a minimum of
1-1/2" spacing to allow for possible extended,
high-heat, no-load heating element operation.
Installation information: Before installing,
consult installation instructions packed with
product for current dimensional data.
Optional accessories: Tall backguard JXS8055
(Available at additional cost)
All GE ranges are equipped with
an Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.
Dimensions and Installation Information (in inches)
C2S980SEMSS
GE Café
™
30" Free-Standing Dual-Fuel Range
with Baking Drawer
Product is shipped with 4-prong
plug. Recommended outlet is
a NEMA 14-50R receptacle.
7-1/2
8
9
4
30
3
3
3
2-1/4
2
NOTE: Make gas connections on
the left side and electrical conections
on the right side of the
cutout opening.
Recommended acceptable
electrical outlet area. Orient
the electrical receptacle so the
length is parallel to the floor.
Wall-Mounted
Recommended area
for through-the-wall
connection of pipe
stub/shut-off valve.
Recommended area for
through-the-floor connection
of pipe stub/shut-off valve.
This area allows
flush installation
to rear wall.
30"
26-1/2"
46-3/4"
36-1/4"
+_
1/4*
*Dimension from floor to top of
the cooktop. Floor to top of rear
vent trim is 37-1/4”
Product is shipped with 4-prong
plug. Recommended outlet is
a NEMA 14-50R receptacle.
7-1/2
8
9
4
30
3
3
3
2-1/4
2
NOTE: Make gas connections on
the left side and electrical conections
on the right side of the
cutout opening.
Recommended acceptable
electrical outlet area. Orient
the electrical receptacle so the
length is parallel to the floor.
Wall-Mounted
Recommended area
for through-the-wall
connection of pipe
stub/shut-off valve.
Recommended area for
through-the-floor connection
of pipe stub/shut-off valve.
This area allows
flush installation
to rear wall.
30"
26-1/2"
46-3/4"
36-1/4"
+_
1/4*
*Dimension from floor to top of
the cooktop. Floor to top of rear
vent trim is 37-1/4”