background image

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

geappliances.com or call GE Answer Center

®

 

service, 800.626.2000.

Specification Revised 2/11

221218

Electrical Requirements: 240v/208v; 60Hz, 40A
Effective January 1, 1996, the National Electrical 
Code requires that new construction (not 
existing) utilize a 4-conductor connection to an 
electric range.
Receptacle Locations: Locally approved flexible 
service cord or conduit must be used because 
terminals are not accessible after range 
installation. See shaded area in drawing for 
location of electrical outlet box. Recommended 
outlet locations allow range to be installed 
directly against wall.
Note: 30" ranges conform to U.L. requirements 
for 0" spacing from adjacent walls below 
countertops. To reduce possibility of scorching 
walls, engineering recommends a minimum of  
1-1/2" spacing to allow for possible extended, 
high-heat, no-load heating element operation.
Installation information: Before installing, 
consult installation instructions packed with 
product for current dimensional data.
Optional accessories: Tall backguard JXS8055 
(Available at additional cost)

All GE ranges are equipped with 

an Anti-Tip device. The installation 

of this device is an important, 

required step in the installation  

of the range.

Dimensions and Installation Information (in inches) 

C2S980SEMSS 

GE Café

 30" Free-Standing Dual-Fuel Range

 with Baking Drawer

Product is shipped with 4-prong 

plug. Recommended outlet is 

a NEMA 14-50R receptacle.

7-1/2

8

9

4

30

3

3

3

2-1/4

 

2

NOTE: Make gas connections on 

the left side and electrical conections 

on the right side of the

cutout opening.

Recommended acceptable 

electrical outlet area. Orient

the electrical receptacle so the

length is parallel to the floor.

Wall-Mounted

Recommended area 

for through-the-wall 

connection of pipe 

stub/shut-off valve.

Recommended area for

through-the-floor connection

of pipe stub/shut-off valve.

This area allows 

flush installation 

to rear wall.

30"

26-1/2"

46-3/4"

36-1/4"

+_

1/4*

*Dimension from floor to top of
 the cooktop. Floor to top of rear
 vent trim is 37-1/4” 

Product is shipped with 4-prong 

plug. Recommended outlet is 

a NEMA 14-50R receptacle.

7-1/2

8

9

4

30

3

3

3

2-1/4

 

2

NOTE: Make gas connections on 

the left side and electrical conections 

on the right side of the

cutout opening.

Recommended acceptable 

electrical outlet area. Orient

the electrical receptacle so the

length is parallel to the floor.

Wall-Mounted

Recommended area 

for through-the-wall 

connection of pipe 

stub/shut-off valve.

Recommended area for

through-the-floor connection

of pipe stub/shut-off valve.

This area allows 

flush installation 

to rear wall.

30"

26-1/2"

46-3/4"

36-1/4"

+_

1/4*

*Dimension from floor to top of
 the cooktop. Floor to top of rear
 vent trim is 37-1/4” 

Отзывы: