NOTE: 

1.  Gardens at Night fittings should only be connected to approved Gardens at Night 24VDC Constant 

Voltage (CV) Power Supplies. FAILURE TO DO SO WILL VOID WARRANTY. 

2.  Gardens at Night fittings must be wired in parallel and connected in accordance with installation 

instructions provided (including soldering of cable joins and sealing using Adhesive Lined End Caps).  

FAILURE TO DO SO WILL VOID WARRANTY. 

 

3.  Fittings are polarity sensitive and need to be connected positive (+) fitting lead to positive (+) incoming 

and exiting feed cables and negative (-) fitting lead to negative (-) incoming and exiting feed cables.

4.  Do not carry fittings by lead as it may cause damage.
5.  Do not connect fittings to constant current (CC) power supplies or AC transformers as this will cause 

permanent fitting failure and VOID WARRANTY.

INSTALLATION INSTRUCTIONS

Flood Light Slim Line 10

GANL-FLSL-10W-24V 

Flood Light Slim Line 20

GANL-FLSL-20W-24V

Flood Light Slim Line 30

GANL-FLSL-30W-24V

Summary of Contents for Flood Light Slim Line 10

Page 1: ...O SO WILL VOID WARRANTY 3 Fittings are polarity sensitive and need to be connected positive fitting lead to positive incoming and exiting feed cables and negative fitting lead to negative incoming and exiting feed cables 4 Do not carry fittings by lead as it may cause damage 5 Do not connect fittings to constant current CC power supplies or AC transformers as this will cause permanent fitting fail...

Page 2: ...1 ...

Page 3: ...unting bracket in desired location Ensure mounting bracket is correctly oriented to light desired area Use the mounting bracket as a template to mark locations of desired mount hole s from options provided A Drill mounting or pilot hole s at centre mark s to suit fastening technique appropriate for substrate material A Attach mounting bracket using fasteners appropriate for the substrate material ...

Page 4: ...g cable Strip PVC insulation from fitting cable to expose strands A Cut incoming feed cable from power supply B Strip PVC insulation to expose copper strands from incoming feed cable B and exiting cable C Fan out all exposed copper strands A Tightly twist positive fitting feed and exiting cable B ensuring shoulders of PVC insulation remain aligned Repeat for negative cables Heat twisted copper wit...

Page 5: ...cap Cap will collapse and encapsulate the join B Adhesive should be visible from the base of the cap Repeat for other cable join To cable joins Place adhesive lined heat shrink tubing or oversized Adhesive Lined End Cap over both cable joins Ensure tube or cap covers outer insulation of cables by 50mm A Apply heat gently If using tubing firmly pinch top of tube with pliers to seal B Oversheath wil...

Page 6: ...5 ...

Page 7: ...6 ...

Page 8: ... someone other than Gardens at Night or its authorised agent c the alleged defect in the Product is within acceptable industry variances d Gardens at Night cannot establish any fault in the Product after testing and inspection e the product has been used for a purpose other than that for which it was designed and manufactured f the defect in the Product has arisen due to the customer s failure to ...

Reviews: