background image

power factor pro manual

Summary of Contents for PF-Pro R

Page 1: ...power factor pro manual ...

Page 2: ...lay in a stadium bar or rehearsal space they all have one thing in common the AC power is supplied from your local utility What s worse is that the power factor supplied from your building s AC outlet is typically poor thanks to increasingly over taxed power lines and raised line impedance In fact the quality of AC power has been so poor for so long most musicians have no idea how great their ampl...

Page 3: ...rman Power Factor Pro Power Conditioner please be sure to read this manual carefully before using WAR N I N G To reduce the risk of electrical shock do not expose this equipment to rain or moisture Dangerous high voltages are present inside the enclosure Do not remove the covers Refer servicing to qualified personnel only The lightning flash with an arrowhead symbol is intended to alert the user t...

Page 4: ... Pro also features a detachable 10 foot 14 gauge heavy duty power cable The Power Factor Pro offers a 20 segment LED bar graph meter that displays incoming voltage between 90 and 128 volts in 2 volt increments The normal range voltages are indicated in green with moderately and extremely high or low voltages in yellow and red respectively The voltmeter s accuracy is 2 volts It can easily be recali...

Page 5: ...ing faults for example accidental connection to 220VAC where 120VAC is expected or an open neutral from a 208 or 240VAC feed The Power Factor Pro s SMP circuit senses voltages that are so high that operation would be impossible and shuts the power down before damage can occur Upon initially applying power to these units the Extreme Voltage indicator LED will be lit if the input voltage is above th...

Page 6: ...rrants its PF Pro and PF Pro R the Product as follows Manufacturer warrants to the original Purchaser of the Product that the Product sold hereunder will be free from defects in material and workmanship for a period of three years from the date of purchase The Purchaser of the product is allowed fifteen days from the date of purchase to complete warranty registration by mail or on line at the Furm...

Page 7: ...This warranty shall be cancelable by Manufacturer at its sole discretion if the product is modified in any way without written authorization from Furman Sound This warranty also does not apply to Products upon which repairs have been affected or attempted by persons other than pursuant to written authorization by Manufacturer THIS WARRANTY IS EXCLUSIVE The sole and exclusive obligation of Manufact...

Page 8: ...may be used SPECIFICATIONS Current rating 12 amps E versions 7 amps Operating Voltage 90 to 140 VAC E versions 180 to 280 VAC Over Voltage Shutdown 140 VAC typically E versions 280 VAC typically Voltmeter Accuracy 2 VAC calibrated with internal trimpot adjustments Spike Protection Modes Line to neutral zero ground leakage Spike Clamping Voltage 188 Vpk 3 000 amps 133 VAC RMS tested to UL 1449 6 00...

Reviews: