manualshive.com logo in svg
background image

Operating Manual - English

FUJITSU Server PRIMERGY RX1330 M3 

Operating Manual

March 2017

Содержание PRIMERGY RX1330 M3

Страница 1: ...Operating Manual English FUJITSU Server PRIMERGY RX1330 M3 Operating Manual March 2017 ...

Страница 2: ... Dokumentation mbH www cognitas de Copyright 2017 FUJITSU LIMITED All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes no liability for damages to third party copyrights or other rights arisin...

Страница 3: ...e components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is used in a hot environment The customer...

Страница 4: ... Dip Immunity of Personal Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain such technology should not be exported fr...

Страница 5: ...RX1330 M3 Operating Manual Only for Japan I Although described in this manual some sections do not apply to Japan These options and routines include CSS Customer Self Service UFM USB Flash Module ...

Страница 6: ...Operating Manual RX1330 M3 ...

Страница 7: ... steps overview 31 4 Important information 33 4 1 Safety instructions 33 4 2 ENERGY STAR 42 4 3 CE conformity 42 4 4 FCC Class A Compliance Statement 43 4 5 Transporting the server 44 4 6 Notes on installing the server in the rack 44 4 7 Environmental protection 45 5 Hardware installation 47 5 1 Unpacking the server 48 5 2 Installing removing the server in from the rack 48 5 3 Connecting devices t...

Страница 8: ...tor on hot plug PSUs 68 6 1 2 3 Indicator on Fujitsu battery unit FJBU 69 6 2 ID card 70 6 3 Switching the server on and off 71 6 4 Configuring the server 73 6 4 1 Configuring the onboard SATA controller 73 6 4 2 Configuring the SAS SATA RAID controller 74 6 4 3 Configuring the server and installing the operating system with the ServerView Installation Manager 74 6 4 4 Configuring the server and i...

Страница 9: ...ointer displayed on screen 81 8 7 Incorrect date and time 82 8 8 Drives reported as dead when starting system 82 8 9 Added drive reported as defective 82 8 10 Error message on screen 83 8 11 Expansion cards or onboard devices not recognized 83 8 12 Temperature warning 83 8 13 No effect of keyboard or mouse 83 8 14 ODD cannot read data 84 ...

Страница 10: ...Operating Manual RX1330 M3 Contents ...

Страница 11: ... R Security functions in the BIOS Setup and on the system board protect the data on the server against manipulation Additional security is provided by the lockable rack door The server occupies 1 height unit in the rack 1 1 Concept and target groups for this manual This operating manual describes how to install set up and operate your server This operating manual is intended for those responsible ...

Страница 12: ...esk leaflet サポー ト サービス for Japan FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual D3375 BIOS Setup Utility for FUJITSU Server PRIMERGY RX1330 M3 Reference Manual I All documentation on PRIMERGY hardware and ServerView software is available online from the Fujitsu manuals server at http manuals ts fujitsu com For Japan http www fujitsu com jp products computing servers primergy manu...

Страница 13: ...following notational conventions are used in this manual Text in italics indicates commands or menu items Quotation marks indicate names of chapters and terms that are being emphasized Ê describes activities that must be performed in the order shown V CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead ...

Страница 14: ...14 Operating Manual RX1330 M3 Introduction ...

Страница 15: ...mponents yourself in the event of an error Hot plug HDD SSD modules Hot plug PSUs Memory modules System fans Expansion cards For information on replacing these components see the FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises In addition CSS errors are dis...

Страница 16: ...ed Platform Module TPM A Trusted Platform Module TPM for safer storage of keys can be implemented as an option This module enables programs from third party manufacturers to store key information e g drive encryption using Windows Bitlocker Drive Encryption The TPM is activated via the BIOS system for more information refer to the D3375 BIOS Setup Utility for FUJITSU Server PRIMERGY RX1330 M3 Refe...

Страница 17: ... The HDD SSD modules are connected to the SAS SATA backplane wirelessly This allows modules to be plugged in or pulled out easily I Up to ten SAS SATA drives are controlled by the SAS SATA RAID controller already installed I Configurations with Eco SATA can only be mixed with BC SATA HDD type SAS and BC SATA drives with the same size can be mixed but not used in the same logical RAID volume Hybrid...

Страница 18: ...oller on page 74 Further information on SAS SATA RAID controllers is provided in the Modular RAID Controller Installation Guide on the Fujitsu manuals server under x86 Servers Expansion Cards Storage Adapters LSI SAS SCSI RAID Controllers Further information on other SAS SATA RAID controllers e g for operating external SAS SATA HDDs or tape drives is available on the Fujitsu manuals server under x...

Страница 19: ...ith Advanced Thermal Design only certain components which support the respectively increased higher operating temperature range may be installed and used For applicable restrictions please refer to the official configurator tool High level of availability and data security When memory data is accessed 1 bit errors are identified in the main memory and automatically corrected with the error correct...

Страница 20: ...ng Browser access via iRMC S4 s own Web server Secure communication SSH SSL Power Management for the managed server depending on its system status Power Consumption Management Connecting virtual drives as remote storage Text based and graphic console bypass Advanced Video Redirection Remote Storage Command Line Interface CLI Simple interactive or script based iRMC S4configuration Customer Self Ser...

Страница 21: ... clock monitoring regardless of server status High performance graphical console bypass AVR protected by HTTPS SSL 128 bit Remote storage via USB Remote power on Temperature monitoring of the CPU and the surrounding area Detailed status and error reports for CPUs and main memory Watchdog timer for Automatic Server Reconfiguration and Restart ASR R in the event that memory modules or CPUs fail Powe...

Страница 22: ...ld the operating system or hardware fail ServerView Remote Management ServerView Remote Management is the remote management solution from Fujitsu for PRIMERGY servers ServerView Remote Management and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operation in the event of errors Remote monitoring and maintenanc...

Страница 23: ...6 CPU quantity and type 1x Intel Xeon E3 1200v6 family Pentium Core i3 Memory slots 4 2 banks with 2 DIMMs each Memory slot type DIMM DDR4 Memory capacity min max 4 GB 64 GB Memory protection ECC USB 3 0 connectors 6 2x front 4x rear USB 2 0 connectors for up to 10 HDDs 1x on front panel on QRL USB 3 0 connectors for up to 10 HDDs 4x rear Graphics 15 pin 1 x VGA rear 1x front VGA as an option not ...

Страница 24: ...lity MegaRAID RAID levels 0 1 10 5 50 6 and 60 are supported for internal HDD configurations SATA Controller A 6 port SATA controller is integrated on the system board up to four SATA HDDs can be connected to the controller The LSI Embedded MegaRAID software SATA Software RAID supports RAID levels 0 1 and 10 Remote Management Controller Integrated Remote Management Controller iRMC S4 256 MB DDR3 8...

Страница 25: ...ra slim ODD Notes accessible drives all possible options described in relevant system configurator Operating buttons On Off button ID button Reset button NMI button Status LEDs Global Error indicator orange ID indicator blue HDD SSD activity indicator green Power on indicator green AC connected indicator green CSS indicator orange Status LED at system rear side Global error CSS ID indicator orange...

Страница 26: ...1 mm Installation depth in rack 572 mm without projecting parts Height 42 8 mm 1 HU Weight approx 8 8 kg 13 2 kg Weight notes Weight may vary depending on actual configuration Rack mounting kit Rack mounting kit as option Environment class 3K2 Environment class 2K2 EN 60721 IEC 721 Part 3 3 EN 60721 IEC 721 Part 3 2 Temperature Operation 3K2 5 C 40 C with ATD 10 C 35 C without ATD Transport 2K2 25...

Страница 27: ... dB A standby 35 dB A operation 36 db A standby 36 db A operation PSU configuration 1x standard PSU or 1x hot plug PSU or 2x hot plug PSUs for redundancy Max output 300 W standard PSU 450 W hot plug PSU Rated voltage range 100 V 240 V Rated frequency range 47 Hz 63 Hz Rated current max 4 0 A 2 0 A 100 V 240 V Battery unit configuration 1x hot plug PSU in bay 1 and 1x FJBU in bay 2 Max output 380 W...

Страница 28: ...UL 60950 1 2ed am1 am2 Australia New Zealand AS NZS 60950 1 Taiwan CNS 14336 China GB 4943 1 India IS 13252 1 Electromagnetic compatibility International CISPR 22 CISPR 32 CISPR 24 Europe EN 55032 Class A EN 55024 EN 61000 3 2 EN 61000 3 3 ETSI EN 300386 USA Canada FCC 47CFR part 15 Class A ICES 003 Australia New Zealand AS NZS CISPR22 Class A AS NZS CISPR32 Class A Taiwan CNS 13438 Class A China ...

Страница 29: ...RX1330 M3 Operating Manual 29 Functional overview V CAUTION This device meets the requirements of Class A CISPR 22 32 This device can cause radio interference in residential areas ...

Страница 30: ...30 Operating Manual RX1330 M3 Functional overview ...

Страница 31: ...Unpacking the server on page 48 Ê Make sure that all necessary manuals see Documentation overview on page 12 are available print out the PDF files if required Ê Components that have been ordered additionally may be delivered loose with the server Install these in the server as described in the supplied documentation Ê Install the server in the rack see section Installing removing the server in fro...

Страница 32: ...erView Suite Server Installation and Deployment Configuration information can also be found in section Configuring the server and installing the operating system with the ServerView Installation Manager on page 74 Local configuration and installation with or without the ServerView Installation Manager see section Configuring the server and installing the operating system with the ServerView Instal...

Страница 33: ...ver in the intended environment please contact your sales outlet or our customer service team The actions described in this manual shall be performed by technical specialists A technical specialist is a person who is trained to install the server including hardware and software Repairs to the server that do not relate to CSS failures shall be performed by service personnel Please note that unautho...

Страница 34: ... C or 45 C If the server is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector the power supply s fuse protection must comply with the requirements for non industrial power supply networks for type A connectors The server automatically adjusts itself to a mains voltage see the type label of your server Ensure that the local mains volta...

Страница 35: ...transmission lines during a storm risk of lightning hazard Make sure that no objects e g jewelry paperclips etc or liquids can get inside the server risk of electric shock short circuit In emergencies e g damaged casing controls or cables penetration of liquids or foreign bodies contact the server administrator or your customer service team Only disconnect the server from the mains power supply if...

Страница 36: ... void the warranty and exempt the manufacturer from all liability The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity To ensure reliable protection you must wear an earthing band on your wrist when working with this type of module and connect it to an unpainted conducting metal part of the server Do not touch the circuitry on boards or sol...

Страница 37: ...e followed V CAUTION Only use CDs DVDs BDs that are in perfect condition in order to prevent data loss equipment damage and injury Check each CD DVD BD for damage cracks breakages etc before inserting it in the drive Note that any additional labels applied may change the mechanical properties of a CD DVD BD and cause imbalance and vibrations Damaged and imbalanced CDs DVDs BDs can break at high dr...

Страница 38: ...ter record sprays antistatic agents or silicone impregnated cloth Be careful not to damage the CD DVD BD surface Keep the CDs DVDs BDs away from heat sources Do not bend or place heavy objects on CDs DVDs BDs Do not write with ballpoint pen or pencil on the label printed side Do not attach stickers or similar to the label side Doing so may cause rotational eccentricity and abnormal vibrations When...

Страница 39: ...ser class 1 V CAUTION The optical disk drive contains a light emitting diode LED which under certain circumstances produces a laser beam stronger than laser class 1 Looking directly at this beam is dangerous Never remove parts of the optical disk drive casing Modules with Electrostatic Sensitive Devices ESD modules Modules with electrostatic sensitive devices are identified by the following sticke...

Страница 40: ...ge I For a detailed description of how to handle ESD modules see the relevant European or international standards EN 61340 5 1 ANSI ESD S20 20 Transporting the server V CAUTION Only transport the server in its original packaging or in packaging that protects it from impacts and jolts In Japan and APAC transporting the server in its original packaging does not apply Do not unpack the server until i...

Страница 41: ...e safety information of the rack and the warning label If the server rack is intended for permanent connection to the mains only an authorized specialist electrician is allowed to work Please follow the regulation of each country If the server is integrated into an installation that draws power from an industrial power supply network with an IEC309 type connector the power supply s fuse protection...

Страница 42: ...g out measurement values including those relating to current energy consumption and air temperatures Either the Performance Monitor or the Task Manager can be used to read out CPU utilization levels The system complies with the requirements of European Regulations Find the CE declaration on certificate portal https sp ts fujitsu com sites certificates default aspx To open the CE declaration applic...

Страница 43: ...ence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between equipment and the receiver Connect...

Страница 44: ...nd disconnecting cables observe the relevant instructions in the chapter Important information of the technical manual for the corresponding rack The technical manual is supplied with the corresponding rack When installing the rack make sure that the anti tilt mechanism is correctly fitted Do not extend more than one unit out of the rack simultaneously even if the tilt protection is in place If se...

Страница 45: ...ched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information does not apply in Japan and APAC Do not throw away the packaging You may need it later for transporting the server If possible the equipment should only be transported in its original packaging Information on handling consumables Please di...

Страница 46: ...ables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or at http ts fujitsu com recycling The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2012 19 EU on waste electrical and electronic equipment WEEE This directive sets the framework for returning and recycling used equipment and i...

Страница 47: ... and heat Make sure that the server is acclimatized for the time indicated in this table before putting it into operation In the table Acclimatization time the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server was exposed previously outside transport or storage temperature Temperature difference C Minimum acclimati...

Страница 48: ...he details on the delivery note The product name and serial number of the product can be found on the ID card see section ID card on page 70 Ê Notify your supplier immediately should you discover that the items delivered do not correspond to the delivery note 5 2 Installing removing the server in from the rack V CAUTION Please observe the safety information and notes on rack mounting in chapter Im...

Страница 49: ...id 5406 5605 5606 For Japan http jp fujitsu com platform server primergy manual peri_rack html To accommodate the ventilation concept and ensure proper ventilation any unused areas in the rack must be sealed using dummy covers The power is supplied via the multiple socket outlets fitted in the rack not valid for Japan The main features of Fujitsu rack systems are as follows rail systems that can b...

Страница 50: ...e connected may require special software e g drivers see the documentation for the connected device Figure 2 Ports on the front The following connectors are located on the front of the server A front VGA connector is available as an option 10 HDD variant For the variant with 10 HDDs of the PRIMERGY RX1330 M3 there is an USB 2 0 connector on the front panel on QRL instead of above mentioned USB3 0 ...

Страница 51: ...MAC address label as LAN2 Standard LAN connector is displayed in the BIOS Setup Utility and on the MAC address label as LAN1 Ê Connect the data cables to the server and peripherals 1 4 x USB 3 0 connectors 4 Standard LAN connector LAN1 2 Serial connector COM1 5 Shared LAN connector LAN2 3 Video connector blue 6 Management LAN connector The serial interface COM1 can be used as the standard interfac...

Страница 52: ...cting the server to the mains In its basic configuration the server has a permanently installed PSU or a hot plug PSU Besides the hot plug PSU a second hot plug PSU can be installed optionally to serve as a redundant PSU If one PSU fails the second PSU in the redundant configuration ensures operation can continue uninterrupted V CAUTION The server is automatically set to a mains voltage in the ran...

Страница 53: ...cted from the server accidentally The cable tie is included in the accessories pack that is delivered together with the server Figure 5 Using cable ties Ê Thread the cable tie through the eye 1 Ê Pull the cable tie tight to secure the power cord The insulated connector cannot now be disconnected from the server accidentally You can loosen the cable tie by opening the small locking lever 2 햳 햲 ...

Страница 54: ...secure the power cords in cable clamps to ensure that the insulated connectors cannot be disconnected from the server accidentally Figure 6 Using cable clamps Ê Pull the cable clamp up 1 Ê Thread the power cord through the cable clamp 2 Ê Press the cable clamp down until it engages to secure the cable 3 ...

Страница 55: ...ng cables Ê Turn off all power and equipment switches Ê Disconnect all power plugs from the properly grounded power outlets Ê Connect all cables to the server and peripherals Ê Plug all data communication cables into the utility sockets Ê Plug all power cords into the properly grounded power outlets Disconnecting cables Ê Turn off all power and equipment switches Ê Disconnect all power plugs from ...

Страница 56: ...lectromagnetic compatibility All data and signal cables must have sufficient shielding The use of cable type S FTP Cat5 or higher is recommended Use of unshielded or badly shielded cables may lead to increased emission of interference and or reduced fault tolerance of the device ...

Страница 57: ...ation V CAUTION Follow the safety instructions in chapter Important information on page 33 6 1 Controls and indicators 6 1 1 Server front 6 1 1 1 Controls on the front panel Figure 7 Controls on the front panel Figure 8 Controls on the front panel on QRL ...

Страница 58: ...e and device driver errors Press the NMI button with a straightened end of a paper clip V CAUTION Use this button only if directed to do so by qualified certified maintenance personnel 3 ID ID button Highlights the ID indicator on the front and I O panels for easy server identification 4 On Off button Used to switch the server on or off I If the system is running an ACPI compliant operating system...

Страница 59: ...L Pos Label Indicator Status Description 1 ID ID indicator see also iRMC related status signals on page 61 blue on The server has been highlighted using ServerView Operations Manager iRMC web frontend or the ID button on the front panel for easy identification blue flashing The server has been highlighted for easy identification using the iRMC AVR with disabled local VGA output ...

Страница 60: ...etected non CSS component orange flashing Non CSS component failure detected Possible causes System is out of the specified range Defective sensor CPU error Error detected by server management software 4 HDD SSD activity indicator green flashing Data access in progress 5 Power on indicator off The server is switched off green on The server has been switched on but Power Cycle Delay settings delay ...

Страница 61: ...nter standby mode and can be switched on off The server is switched off and not connected to the mains The server is switched on and operating normally ID indicator Global error indicator Description blue flashing off A remote connection has been established Local VGA output has been disabled during the remote session blue flashing orange flashing An emergency flash of the iRMC firmware is in prog...

Страница 62: ...cators on the accessible drives components Indicators on the ODD Figure 11 Indicator on the ODD I There are also ODDs without activity indicators Pos Indicator Status Description 1 Activity indicator off The ODD is inactive green on The storage medium is being accessed ...

Страница 63: ...inactive green on The HDD SSD is being accessed 2 Error indicator off No HDD SSD error detected orange on An HDD SSD error has been detected Possible causes The drive is defective and needs replacing A RAID rebuild process has failed The HDD SSD module has not been inserted correctly orange flashing slowly RAID rebuild is in progress Data is being restored after replacing a drive that has been com...

Страница 64: ...see also iRMC related status signals on page 66 blue on The server has been highlighted using ServerView Operations Manager iRMC web frontend or the ID button on the front panel for easy identification blue flashing The server has been highlighted for easy identification using the iRMC AVR with disabled local VGA output CSS CSS indicator off No critical event detected CSS component orange on Prefa...

Страница 65: ...or further details on detected errors refer to the System Event Log SEL or use the ServerView Operations Manager or iRMC S4 web interface Global Error indicator see also iRMC related status signals on page 66 off No critical event detected non CSS component orange on Prefailure event detected non CSS component orange flashing Non CSS component failure detected Possible causes System is out of the ...

Страница 66: ...hing off A remote connection has been established Local VGA output has been disabled during the remote session blue flashing orange flashing An emergency flash of the iRMC firmware is in progress I For further information on the emergency flash of the iRMC firmware refer to the FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual ...

Страница 67: ... link transfer indicator green on A LAN connection has been established off LAN is not connected green flashing LAN data transfer is in progress 2 LAN speed indicator yellow on Data traffic at a transfer rate of 1 Gbit s green on Data traffic at a transfer rate of 100 Mbit s off Data traffic at a transfer rate of 10 Mbit s 햲 햳 햲 햳 햲 햳 ...

Страница 68: ...U status indicator green flashing The server is switched off but mains voltage is present standby mode green on The server is switched on and operating properly orange flashing An overload has been detected The PSU is still running but failure might be imminent orange on An PSU failure has been detected Possible causes Over under voltage Overheating Fan failure 0 0 ...

Страница 69: ...cator Status Description 1 FJBU status indicator green flashing The battery unit is charging green flashing slowly The battery unit is discharging green on The battery unit is fully charged orange flashing A battery unit failure has been detected Possible causes Capacity failure Overheating orange on A general battery failure has occurred ...

Страница 70: ...ID card Figure 17 ID card You can pull out the ID card 1 and push it back again The ID card contains various system information such as the product name serial number order number MAC addresses and DNS name for Japan only the product name and the serial number 햲 ...

Страница 71: ...ronment range 10 35 C For details on the operating environment refer to Safety Precautions When operating the device outside of this operating environment the server may operate improperly and data loss may occur Furthermore Fujitsu cannot be held responsible for any related damage malfunction or loss of data etc Be sure to wait for 10 seconds or more after shutdown before turning the server on ag...

Страница 72: ...n the operating system properly The server is switched off automatically and goes into standby mode The AC connected indicator lights up green I If the operating system does not switch the server off automatically press the On Off button for at least four seconds and or send a corresponding control signal for power button override V CAUTION There is a risk that data may be lost Other On Off option...

Страница 73: ...ring the onboard SATA controller A SATA controller is integrated on the system board You can configure the onboard controller either before or during installation with the ServerView Installation Manager Using the ServerView Installation Manager is recommended I The controller has its own configuration utility For further information refer to the Embedded MegaRAID Software User s Guide on the Fuji...

Страница 74: ...ating systems not covered in the controller manual are provided in the corresponding readme under http www fujitsu com global services computing server ia driver index html For Japan http www fujitsu com jp products computing servers primergy downloads 6 4 3 Configuring the server and installing the operating system with the ServerView Installation Manager Using the ServerView Installation Manager...

Страница 75: ...If you are using the ServerView Installation Manager you can skip the following section on how to configure the server and install the operating system Continue from section Cleaning the server on page 76 6 4 4 Configuring the server and installing the operating system without the ServerView Installation Manager Configuring the onboard SAS SATA controller Configure the controller as described in s...

Страница 76: ... clean any interior parts yourself leave this job to a service technician Do not use any cleaning agents that contain abrasives or may corrode plastic Ensure that no liquid enters the system Ensure that the ventilation areas of the server and the monitor are clear Do not use any cleaning sprays including flammable types It may cause a device failure or a fire Clean the keyboard and the mouse with ...

Страница 77: ...ccess you can activate the security functions of the BIOSSetup 7 1 BIOS Setup security functions The Security menu in BIOS Setup offers various options for protecting your data from unauthorized access By combining these options you can achieve optimum protection for your system I A detailed description of the Security menu and how to assign passwords can be found in the BIOS Setup documentation ...

Страница 78: ...78 Operating Manual RX1330 M3 Property and data protection ...

Страница 79: ... a list of the steps performed and the circumstances that led to the fault Also make a list of any error messages that were displayed Ê Switch off the server Ê Contact our customer service team 8 1 Power on indicator remains unlit The power on indicator remains dark after you switch on your device Power cable incorrectly connected Ê Make sure that the power cable is correctly connected to the serv...

Страница 80: ... VGA connector the monitor connected to the rear VGA connector remains blank Brightness control is set to dark Ê Set the brightness control on the monitor to light For detailed information refer to the operating manual supplied with your monitor Power cable or monitor cable not connected Ê Switch off the monitor and the server Ê Check whether the power cable is properly connected to the monitor an...

Страница 81: ...een display or display drifts The wrong horizontal frequency or resolution has been selected for the monitor or for the application program Ê Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor Ê Refer to the documentation for your operating syst...

Страница 82: ...l or contact our customer service team 8 8 Drives reported as dead when starting system This error message can occur when the onboard SAS controller has RAID functionality or the server is equipped with a PCI RAID controller RAID controller configuration incorrect Ê Check and correct the settings for the drives using the RAID controller utility Further information is provided in the manual for the...

Страница 83: ...tification of a temperature warning such as by a popup message The above log is output or the above notification is issued by ServerView when the ambient temperature exceeds the upper limit of the temperature boundaries The upper limit is 35 C for standard server and 40 C with Advanced Thermal design Ê Although continued use within the temperature boundaries poses no problems within itself reconsi...

Страница 84: ...D DVD BD is inserted properly If it is not inserted correctly insert the disk so that the label is facing up Ê Check to see whether the CD DVD BD is not dirty If it is dirty wipe it with a soft dry cloth Ê Check to see whether the CD DVD BD is not scratched or bent If scratched or damaged replace the CD DVD BD ...

Отзывы: