Page 1: ...ETERNUS CLI User s Guide P2X0 1030 09ENZ0 FUJITSU Storage ETERNUS DX80 S2 DX90 S2 ETERNUS DX410 S2 DX440 S2 ETERNUS DX8100 S2 DX8700 S2 Disk storage systems ...

Page 2: ...This page is intentionally left blank ...

Page 3: ...sk storage system in this document Ninth Edition August 2015 Content and Structure This manual contains the following six chapters and appendices Chapter 1 Overview This chapter introduces the ETERNUS DX Disk storage system Command Line Interface CLI Chapter 2 Status Display This chapter explains the commands used for displaying the status details for the ETERNUS DX Disk storage system as a whole ...

Page 4: ...lated Manuals The following manuals contain further relevant information on the ETERNUS DX80 S2 DX90 S2 the ETERNUS DX410 S2 DX440 S2 and the ETERNUS DX8100 S2 DX8700 S2 ETERNUS DX80 S2 DX90 S2 Disk storage system Overview ETERNUS DX80 S2 DX90 S2 Disk storage system User s Guide Site Planning ETERNUS DX80 S2 DX90 S2 Disk storage system User s Guide Installation ETERNUS DX80 S2 DX90 S2 Disk storage...

Page 5: ...vice names mentioned in this document are registered trademarks or trademarks of their respective companies Additional Information Naming conventions Oracle Solaris might be described as Solaris Solaris Operating System or Solaris OS The following abbreviations are used for Microsoft Windows Server Official name Abbreviation Microsoft Windows Server 2008 R2 Datacenter Windows Server 2008 R2 Micros...

Page 6: ...separator within brackets indicates that only one of the separated parameters can be specified parameter parameter A separator within braces indicates that only one of the separated parameters must be specified Note that some cases two or more parameters can be specified by separating them with a comma parameter parameter This symbol indicates restrictions and cautions for setting up and operating...

Page 7: ... 2 8 RAID Group Syntax 22 1 2 9 Volume Syntax 22 1 2 10 Host Syntax 23 1 2 11 Affinity Group Syntax 24 1 2 12 Host Response Syntax 24 1 2 13 ECO Schedule Syntax 25 1 2 14 Host Interface Port Syntax 25 1 2 15 Port Group Syntax 26 1 2 16 Host Group Syntax 26 1 3 Size of Devices and Logical Units 27 1 4 Command Auto complete and History Recall 27 1 5 Command Editing Hotkeys 28 1 6 Viewing Command Hel...

Page 8: ...o pool 77 delete thin pro pool 78 show thin pro pools 79 show thin pro pool progress 81 expand thin pro pool 83 format thin pro pool 85 3 1 2 Thin Provisioning Pool ECO Management 86 set eco thin pro pool 87 release eco thin pro pool 89 show eco thin pro pool 90 3 2 Flexible Tier Management 91 3 2 1 Flexible Tier Pools 91 show flexible tier mode 92 delete flexible tier pool 93 show flexible tier p...

Page 9: ...chedule 134 delete eco schedule 137 show eco schedule 138 set eco raid group 140 release eco raid group 142 show eco raid group 143 3 4 Volume Management 144 3 4 1 Volume 144 create volume 145 set volume 149 delete volume 151 delete all volumes 152 show volumes 153 show volume progress 158 show volume mapping 160 format volume 162 expand volume 163 start migration 165 stop migration 167 show migra...

Page 10: ...parameters 208 show iscsi parameters 217 set fcoe parameters 220 show fcoe parameters 223 3 5 2 Host Identifiers Host Alias 226 create host wwn name 227 set host wwn name 229 delete host wwn name 230 show host wwn names 231 discover host wwn names 232 create host sas address 233 set host sas address 235 delete host sas address 237 show host sas addresses 238 discover host sas addresses 239 create ...

Page 11: ...ost response 296 show host response 297 3 5 8 Host Sense Conversion 299 set host sense 300 delete host sense 302 show host sense 303 3 5 9 Reset Group for Host Interface Port 304 set ca reset group 305 show ca reset group 306 3 5 10 Ping Command for iSCSI hosts 307 test iscsi ping 308 3 5 11 Port Groups 310 create port group 311 set port group 312 delete port group 314 show port groups 315 3 5 12 ...

Page 12: ...lic key 369 delete ssh public key 371 4 1 2 RADIUS Server Settings 372 set radius 373 show radius 376 4 2 Advanced Copy Management 378 4 2 1 SnapOPC Outline 379 4 2 2 Preparations for the Advanced Copy Function 379 4 2 3 Copy Session Management 383 set advanced copy license 385 delete advanced copy license 386 show advanced copy license 387 set advanced copy policy 389 show advanced copy policy 39...

Page 13: ...k buffer 443 set rec disk buffer 445 delete rec disk buffer 446 show rec disk buffer 447 format rec disk buffer 449 release rec disk buffer 450 4 3 Network Management 451 4 3 1 Network Settings 451 set network 452 show network 458 set firewall 463 show firewall 466 4 3 2 SNMP 468 set snmp 469 show snmp 471 create snmp manager 472 set snmp manager 473 delete snmp manager 474 show snmp manager 475 c...

Page 14: ... Configuration 530 create ssh server key 533 create ssl certificate 534 export ssl certificate request 536 import ssl certificate 540 4 3 7 AIS Connect Settings 541 set ais connect 542 show ais connect 547 set ais connect remote session 549 test ais connect 550 send ais connect log 551 test ais connect event notification 552 import ais ssl certificate 553 4 4 Miscellaneous 554 4 4 1 Date Time and ...

Page 15: ... 587 set sed key machine name 589 show sed key machine name 590 set sed key server 591 show sed key servers 592 import ssl kmip certificate 593 create sed key group 594 set sed key group 596 delete sed key group 598 show sed key groups 599 change sed key 601 recover sed key group 602 4 4 10 Shutdown Restart System 603 shutdown 604 Chapter 5 Information Settings and Display 605 5 1 Performance 605 ...

Page 16: ...n 645 export config information 646 show config information 648 5 3 7 Error Information 649 show disk error 650 clear disk error 651 show port error 652 5 3 8 Bad Data Information in Volumes 655 show bad data info 656 5 4 Utility 658 5 4 1 Diagnosis Utilities 658 show diagnosis 659 5 4 2 LED 665 set led 666 show led 667 5 4 3 Other Notification 668 set event parameters 669 show event parameters 67...

Page 17: ...ppendix D Basic Setting Examples 739 D 1 Settings When Using Volumes 739 D 1 1 RAID Configuration Setting Procedure 740 D 1 2 Host Access Setting Procedure 741 D 2 Settings for Various Host Accesses 742 D 2 1 Specifying a Host and Performing Mapping Host Affinity Mode 743 D 2 2 Specifying a Port Group and Performing LUN Mapping 744 D 2 3 Specifying a Port and Setting LUN Mapping 745 D 3 Setting Ca...

Page 18: ...ay be done via LAN connection to the controller module s Ethernet port using telnet an SSH application or a terminal emulator on a remote administrator client For telnet connection a user name and password are required For SSH in addition to a user name and password SSH public key authentication is also supported For details refer to the import ssh public key command Default IP address user name a...

Page 19: ...rs they must be enclosed by double quotation marks Example ABC DEF ABC DEF GHIJKL When double quotation marks and single quotation marks are used as characters they must be backslash escaped Example 1 2 3 Disk Syntax The format that can used for disk drive numbers is either xxyy or xyy xx or x indicates the enclosure number xx indicates a 2 digit number for the enclosure number and x indicates a o...

Page 20: ...and Thin provisioning pool numbers can be combined as follows A single Thin provisioning pool number 1 A list of Thin provisioning pool numbers 1 8 12 A hyphenated range of Thin provisioning pool numbers from a to z 2 5 A list of Thin provisioning pool numbers Thin provisioning pool ranges or both separated by commas Spaces are not permitted before or after commas 1 3 10 12 Thin provisioning pool ...

Page 21: ...e same command Do not include spaces before or after commas 1 2 7 Flexible Tier Sub Pool Syntax There are two methods for identifying an entered Flexible Tier Sub Pool Flexible Tier Sub Pool numbers or Flexible Tier Sub Pool names Flexible Tier Sub Pool number A Flexible Tier Sub Pool number is automatically created by the system when a Flexible Tier Sub Pool is created This is a decimal number Fl...

Page 22: ... both be specified in the same command Do not include spaces before or after commas 1 2 9 Volume Syntax There are two methods to specify a volume identifier a volume number or a volume name Volume number A volume number is automatically created by the system when a volume is created This is a decimal number Volume numbers can be displayed by using the show volumes command Volume numbers may be com...

Page 23: ...st name iSCSI The identifier can be displayed by using the following commands show host wwn names show host sas addresses show host iscsi names Host numbers may be combined as follows A single host number 1 A list of host numbers 2 3 A hyphenated range of host numbers from a to z 2 5 A list of host numbers host ranges or both separated by commas Spaces are not permitted before or after commas 1 3 ...

Page 24: ...parated list of affinity group names An affinity group name and an affinity group number cannot both be specified in the same command Do not include spaces before or after commas 1 2 12 Host Response Syntax There are two methods to specify a host response identifier a host response number or a host response name Host response number The host response number can be assigned by the user This is a de...

Page 25: ...ule numbers from a to z 2 5 A list of ECO schedule numbers ECO schedule ranges or both separated by commas Spaces are not permitted before or after commas 1 3 10 12 ECO schedule name An ECO schedule name must be specified when creating an ECO schedule For details about the syntax refer to 1 2 4 Alias Name Syntax page 20 Some commands accept a comma separated list of ECO schedule names An ECO sched...

Page 26: ...clude spaces before or after commas 1 2 16 Host Group Syntax There are two methods to specify an host group identifier an host group number or an host group name Host group number An host group number is automatically created by the system when an host group is created This is a decimal number Host group numbers can be displayed by using the show host groups command Host group numbers may be combi...

Page 27: ...and redisplays the string so it can be completed The auto complete function applies to a command name a parameter name and an operand name It does NOT apply when two or more operands are used that are separated with a comma Except for operand names even if not all the letters of the keyword are not entered once enough letters are entered to identify a unique keyword it is handled as a complete cha...

Page 28: ...rl f Move back one word Esc B or Esc b Move forward one word Esc F or Esc f Move cursor to start of line Ctrl A or Ctrl a Move cursor to end of line Ctrl E or Ctrl e Transpose current and previous character Ctrl T or Ctrl t Delete current character Ctrl D or Ctrl d Delete previous character Ctrl H or Ctrl h Delete word up to cursor Ctrl W or Ctrl w Delete rest of word Esc D or Esc d Delete text up...

Page 29: ...anced copy licens Display the Extended Advanced Copy license status advanced copy parame Display the Advanced Copy parameters advanced copy policy Display the currently registered Advance Copy policy advanced copy sessio Display the list of Advance Copy sessions affinity groups Display a list of affinity groups or display the details of a specified affinity group snip If show m is entered all the ...

Page 30: ...etes and then execute the command again Resources can be forcibly released by using the set clienv force unlock command This is useful when a terminal is suddenly disconnected or unexpected errors occur 1 9 Slave Controller Logins For dual controller ETERNUS DX Disk storage system models at any given time one of the controllers is the master and the other the slave Normal logins are to the master ...

Page 31: ... an FTP server is specified by an IP address an appropriate Ethernet port is automatically assigned by the system Even though designation of an Ethernet port by using CLI is not required doing so allows the operator to specify which network the FTP server belongs to 1 12 Command Descriptions This section explains the commands in a functional order Each command topic includes one or more of the fol...

Page 32: ...ler enclosures show fru ce type brt0 brt1 brt2 brt3 brt4 brt5 brt6 brt7 SVC status in controller enclosures show fru ce type svc0 svc1 The status of all components in controller enclosures show fru ce IOM status in a specific drive enclosure show fru de de 1 2 3 4 5 6 7 8 9 type exp0 exp1 All expander status in all drive enclosure show fru de type exp0 exp1 PSU status in a specific drive enclosure...

Page 33: ... undefined component is installed in the ETERNUS DX Disk storage system Warning A component that is the target for preventive maintenance exists in the ETERNUS DX Disk storage system Maintenance Maintenance is currently being performed on the ETERNUS DX Disk storage system Error A component with an error exists in the ETERNUS DX Disk storage system Loop Down The ETERNUS DX Disk storage system is i...

Page 34: ...tional This parameter can specify the drive enclosure number only when a drive enclosure type is specified If this parameter is omitted all of the drive enclosures are selected Other enclosure types cannot be specified Example type de de 1 When requesting drive enclosure 1 details The following information is the output information when all the parameters are omitted Name Series name of the system...

Page 35: ...nts that have occurred in the system The following information is output for the controller enclosure components Intake Temp Intake temperature status status code and intake temperature values Each controller has two redundant intake temperature sensors and both temperature values is displayed in Celsius If a sensor fails Failed is displayed Exhaust Temp Exhaust temperature status and the status c...

Page 36: ...tus Status Code For Power Supply Unit 1 DISK xyy Disk status only for the ETERNUS DX80 S2 DX90 S2 Example CE Disk 1 status Disk 001 status For details refer to 1 2 3 Disk Syntax page 19 The following information is displayed if the device enclosure is specified Intake Temp Intake TempIntake temperature status status code and intake temperature values Each controller has two redundant intake temper...

Page 37: ...r Enclosure Information Location Status Error Code Sensor 1 Sensor 2 Intake Temp Normal 0x0000 25 C 25 C Exhaust Temp Normal 0x0000 Controller Enclosure Status Controller Module Status Status Code CM 0 Normal 0xE001 CM 1 Normal 0xE001 Power Supply Unit Status Status Code PSU 0 Normal 0xE001 PSU 1 Normal 0xE001 Disk Status CE Disk 0 Rebuild Copyback CE Disk 1 Rebuild Copyback CE Disk 2 Available CE...

Page 38: ... Service Controller Status Status Code SVC 0 Normal 0xE001 SVC 1 Normal 0xE001 FAN Unit Status Status Code FANU 0 Normal 0xE001 FANU 1 Normal 0xE001 FANU 2 Normal 0xE001 FANU 3 Normal 0xE001 Operation Panel Status Status Code OPNL Normal 0xE001 Power Supply Unit Status Status Code PSU 0 Normal 0xE001 PSU 1 Normal 0xE001 PSU 2 Normal 0xE001 PSU 3 Normal 0xE001 PSU 4 Normal 0xE001 PSU 5 Normal 0xE00...

Page 39: ... Disk 0 Rebuild Copyback CE Disk 1 Rebuild Copyback CE Disk 2 Available CE Disk 3 Broken CE Disk 4 Available CE Disk 5 Available Predictive Failure CE Disk 6 Available Predictive Failure CE Disk 7 Present CE Disk 8 Present CE Disk 9 Present CE Disk 10 Present CE Disk 11 Spare Drive Enclosure 1 Information Location Status Error Code Sensor 1 Sensor 2 Intake Temp Normal 0x0000 25 C 25 C Exhaust Temp...

Page 40: ...E001 FAN Unit Status Status Code FANU 0 Normal 0xE001 FANU 1 Normal 0xE001 FANU 2 Normal 0xE001 FANU 3 Normal 0xE001 Operation Panel Status Status Code OPNL Normal 0xE001 Power Supply Unit Status Status Code PSU 0 Normal 0xE001 PSU 1 Normal 0xE001 PSU 2 Normal 0xE001 PSU 3 Normal 0xE001 PSU 4 Normal 0xE001 PSU 5 Normal 0xE001 Drive Enclosure 0 Information Location Status Error Code Sensor 1 Sensor...

Page 41: ...omitted all of the FRUs are displayed ETERNUS For the ETERNUS DX80 S2 DX90 S2 ETERNUS DX410 S2 DX440 S2 and ETERNUS DX8100 S2 cm0 Details and status of the Controller Module Unit 0 and the sub components cm1 Details and status of the Controller Module Unit 1 and the sub components psu0 Details and status of the Power Supply Unit 0 psu1 Details and status of the Power Supply Unit 1 For the ETERNUS ...

Page 42: ...IOS Next EC An EC number of the stand by firmware The generation number of the firmware after the next power cycle CM EXP Active EC An EC number of the active firmware The current operating firmware only for the ETERNUS DX80 S2 DX90 S2 ETERNUS DX410 S2 DX440 S2 and ETERNUS DX8100 S2 CM EXP Next EC An EC number of the stand by firmware The generation number of the firmware after the next power cycl...

Page 43: ... status and the status code ETERNUS DX80 S2 DX90 S2 ETERNUS DX410 S2 DX440 S2 and ETERNUS DX8100 S2 only CM EXP InPort CM EXP InPort status and the status code ETERNUS DX80 S2 DX90 S2 ETERNUS DX410 S2 DX440 S2 and ETERNUS DX8100 S2 only SAS Cable OUT SAS Cable OUT status and the status code ETERNUS DX80 S2 DX90 S2 ETERNUS DX410 S2 DX440 S2 and ETERNUS DX8100 S2 only CM RTC CM RTC status and the st...

Page 44: ...are after the next power cycle ETERNUS DX8700 S2 only CM MMC Firmware Version CM MMC firmware version ETERNUS DX8700 S2 only PCH PCH status and the status code CM n CA m Port l Information n The controller module number m The Channel Adapter number l The port number For FC iSCSI FCoE and SAS Port Type It shows if the host interface port type is FC iSCSI FCoE or SAS Port Mode It shows if the host i...

Page 45: ...erver Port No iSNS Server Port Number TCP Port No TCP Port Number TCP Window Size TCP Window Size FC Frame Size FC Frame Size VLAN ID VLAN ID Header Digest Header Digest Date Digest Date Digest Bandwidth Limit Bandwidth Limit Target Portal Group Number Target Portal Group Number CmdSN Count CmdSN Count Err Recovery Lvl Error Recovery Level Task Retain Time The time required for processes stopped d...

Page 46: ...ow High RX Power Receiver power Present Warning Low High and Alarm Low High CM n CA m Port l Information n The controller module number m The Channel Adapter number l The port number For FCLINK and OCLINK Port Type Host interface port type FCLINK or OCLINK Status Status Code Host interface Port Port m status and the status code FRT n Information n The front end router number ETERNUS DX8700 S2 only...

Page 47: ...ower cycle EXP Firmware Version BRT Expander firmware version InPort BRT Expander InPort status QSFP Cable OUT BRT QSFP Cable status and the status code SVC n Information n The service controller number ETERNUS DX8700 S2 only Parts Number SVC Parts Number Serial Number SVC Serial Number Hard Revision SVC Hard Revision MAC Address MNT SVC MAC address MNT MAC Address RMT SVC MAC address RMT MAC Addr...

Page 48: ... status code SVC RCI board SVC RCI board status and the status code BCU BTU Information The following information is displayed for the ETERNUS DX410 S2 DX440 S2 BCU Status Status Code BCU status and the status code BCU Status Status Code BTU status and the status code BCU ChargeRate Charging rate of BCU BCU Expires Expiry date of the BCU BCU Parts Number BCU Parts Number BCU Serial Number BCU seri...

Page 49: ...he ETERNUS DX8700 S2 Status Status Code FAN Unit status and the status code Parts Number FAN Unit Parts number Serial Number FAN Unit Serial Number Hard Revision FAN Unit Hard Revision OPNL Information The following information is displayed for the ETERNUS DX8700 S2 Status Status Code Operation Panel status and the status code Parts Number Operation Panel Parts number Serial Number Operation Panel...

Page 50: ...mory 1 Hard Revision Memory 2 Undefined 0x0000 Memory 2 Parts Number Memory 2 Serial Number Memory 2 Hard Revision Memory 3 Undefined 0x0000 Memory 3 Parts Number Memory 3 Serial Number Memory 3 Hard Revision Memory 4 Undefined 0x0000 Memory 4 Parts Number Memory 4 Serial Number Memory 4 Hard Revision Memory 5 Undefined 0x0000 Memory 5 Parts Number Memory 5 Serial Number Memory 5 Hard Revision BUD...

Page 51: ... EC 0 CA Next EC EC 0 Connection Loop Loop ID 0x00 Transfer Rate Auto Negotiation Link Status Unknown Port WWN 500000E0D1000000 Node WWN 500000E0D1000000 Host Affinity Disable Host Response 0 SFP Type ShortWave SFP Information Present Warning Low High Alarm Low High Temperature 40 11C 15 00C 100 00C 30 00C 128 00C Voltage 4 24V 3 00V 5 00V 2 00V 7 00V Current 10 25mA 5 00mA 12 00mA 2 00mA 15 00mA ...

Page 52: ...nd details of controller module 0 for the ETERNUS DX8100 S2 CLI show fru ce type cm0 CM 0 Information CPU 0 Status Status Code Normal 0xE001 CPU 1 Status Status Code Undefined 0x0000 Memory Size 1 5GB Parts Number Serial Number Hard Revision CPU 0 Clock 2 00GHz CPU 1 Clock 0 00GHz CM Active EC EC 1 CM Next EC EC 1 BIOS Active EC EC 0 BIOS Next EC EC 0 CM EXP Active EC EC 1 CM EXP Next EC EC 1 CM 0...

Page 53: ...EXP 1 Undefined 0x0000 CM EXP 1 InPort 0 Undefined 0x0000 CM EXP 1 InPort 1 Undefined 0x0000 SAS Cable 2 OUT Undefined 0x0000 SAS Cable 3 OUT Undefined 0x0000 CM RTC Normal 0xE001 CM NVRAM Normal 0xE001 CM FPGA Normal 0xE001 CM LAN Port 0 Normal 0xE001 CM LAN Port 1 Normal 0xE001 CM LAN Port 2 Normal 0xE001 DI Port 0 Normal 0xE001 DI Port 1 Normal 0xE001 DI Port 2 Undefined 0x0000 DI Port 3 Undefi...

Page 54: ...Status Code Normal 0xE001 BTU 1 Status Status Code Normal 0xE001 BCU 1 ChargeRate 0 BCU 1 Expires 0 00 BCU 1 Parts Number BCU 1 Serial Number BCU 1 Hard Revision BCU 2 Status Status Code Normal 0xE001 BTU 2 Status Status Code Normal 0xE001 BCU 2 ChargeRate 0 BCU 2 Expires 0 00 BCU 2 Parts Number BCU 2 Serial Number BCU 2 Hard Revision SCCI 0 Information Status Status Code Normal 0xE001 SCCI 1 Info...

Page 55: ...CJFA020351TY10KY CA 0 Parts Number CA 0 Serial Number CA 0 Hard Revision CA Slot 0 0 Normal 0xE001 CA Slot 0 1 Undefined 0x0000 CA 1 Parts Number CA 1 Serial Number CA 1 Hard Revision CA Slot 1 0 Undefined 0x4000 CA Slot 1 1 Undefined 0x0000 CA 2 Parts Number CA 2 Serial Number CA 2 Hard Revision CA Slot 2 0 Undefined 0x0000 CA Slot 2 1 Undefined 0x0000 CA 3 Parts Number CA 3 Serial Number CA 3 Ha...

Page 56: ...tatus Code Normal 0xE001 CA Active EC EC 0 CA Next EC EC 0 Connection Loop Loop ID 0x00 Transfer Rate Auto Negotiation Link Status Unknown Port WWN 500000E0D1000000 Node WWN 500000E0D1000000 Host Affinity Disable Host Response 0 SFP Type ShortWave SFP Information Present Warning Low High Alarm Low High Temperature 40 11C 15 00C 100 00C 30 00C 128 00C Voltage 4 24V 3 00V 5 00V 2 00V 7 00V Current 1...

Page 57: ...mation Status Status Code Normal 0xE001 ChargeRate 0 Expires 2011 10 BBU 2 Information Status Status Code Normal 0xE001 ChargeRate 0 Expires 2011 10 BBU 3 Information Status Status Code Normal 0xE001 ChargeRate 0 Expires 2011 10 SCCI 0 Information Status Status Code Normal 0xE001 SCCI 1 Information Status Status Code Normal 0xE001 FANU 0 Information Status Status Code Normal 0xE001 Parts Number Se...

Page 58: ...ormal 0xE001 InPort 9 Normal 0xE001 InPort 10 Normal 0xE001 InPort 11 Normal 0xE001 InPort 12 Normal 0xE001 InPort 13 Normal 0xE001 InPort 14 Normal 0xE001 InPort 15 Normal 0xE001 QSFP Cable 0 OUT Normal 0xE001 QSFP Cable 1 OUT Normal 0xE001 QSFP Cable 2 OUT Normal 0xE001 QSFP Cable 3 OUT Normal 0xE001 QSFP Cable 4 OUT Normal 0xE001 QSFP Cable 5 OUT Normal 0xE001 QSFP Cable 6 OUT Normal 0xE001 QSF...

Page 59: ... Link Down PHY 2 Link Down PHY 3 Link Down Port WWN 500000E0D1000011 Node WWN 500000E0D1000000 Host Affinity Disable Host Response 3 For iSCSI information the following information is displayed CM 0 CA 0 Port 0 Information Port Type iSCSI Port Mode CA Status Status Code Normal 0xE001 CA Active EC EC 0 CA Next EC EC 0 Transfer Rate 1Gbps Auto Link Status Link Down iSCSI Name iqn 2000 09 com fujitsu...

Page 60: ...t 10 25mA 5 00mA 12 00mA 2 00mA 15 00mA TX Power 1 35mW 0 50mW 1 50mW 0 00mW 1 80mW RX Power 1 35mW 0 50mW 1 50mW 0 00mW 1 80mW For FCoE information the following information is displayed CM 0 CA 0 Port 0 Information Port Type FCoE Status Status Code Normal 0xE001 CA Active EC EC 0 CA Next EC EC 0 Transfer Rate 10Gbps Link Status Unknown Port WWN 500000E0D1000010 Node WWN 500000E0D1000000 Host Aff...

Page 61: ... CM 1 Port 0 Information Port Type FC Port Mode RFCF RA Status Status Code Normal 0xE001 For SCU Information the following information is displayed SCU Information SCU 0 Status Status Code Normal 0xE001 SCU 0 Voltage 9 40V SCU 0 Expires 0 00 SCU 0 Parts Number SCU 0 Serial Number SCU 0 Hard Revision SCU 1 Status Status Code Normal 0xE001 SCU 1 Voltage 9 40V SCU 1 Expires 0 00 SCU 1 Parts Number SC...

Page 62: ...closure will also be displayed Only one parameter can be specified If this parameter is omitted all of the FRUs are displayed iom0 Details and status of the I O module 0 iom1 Details and status of the I O module 1 psu0 Details and status of the Power Supply Unit 0 psu1 Details and status of the Power Supply Unit 1 The following table shows the output information for the IOM DE n IOM m Information ...

Page 63: ...owing table shows the output information for the power supply units Status Status Code Power supply unit PSU n status and the status code Error Code Error code to identify error events that occurred in a power supply unit This information is only displayed when the Status is not Normal or Undefined The following example displays the status of I O module 0 in drive enclosure 1 CLI show fru de de 1 ...

Page 64: ...S DX80 S2 DX90 S2 de All disks in the specified drive enclosure When using this parameter the de parameter and the drive enclosure number must also be specified de Optional This parameter specifies the number of the drive enclosure for which details are to be obtained This parameter cannot be used for other category types disks Optional This parameter specifies which disk number to display the det...

Page 65: ...rpm Usage Disk usage Example Data Spare System etc RAID Group RAID group to which this disk belongs Motor Status Disk motor status by ECO functions Rebuild Copy back Progress Progress status of Rebuild and Copy back Vendor ID Vendor ID Product ID Product ID Serial Number Serial number WWN World Wide Name Firmware Revision Disk firmware version For the product ID list the following items are displa...

Page 66: ...isk 1 Available 146GB 3 5 SAS 15000 Data DE 1 Disk 2 Available 146GB 3 5 SAS 15000 Data DE 1 Disk 3 Available 146GB 3 5 SAS 15000 Data DE 1 Disk 4 DE 1 Disk 5 Available 146GB 3 5 SAS 15000 Data DE 1 Disk 6 DE 1 Disk 7 DE 1 Disk 8 DE 1 Disk 9 Available 146GB 3 5 SAS 15000 Data DE 1 Disk 10 Available 146GB 3 5 SAS 15000 Global Hot Spare DE 1 Disk 11 Available 146GB 3 5 SAS 15000 Dedicated Hot Spare ...

Page 67: ...enclosure Other Information Individual identifier embedded in the controlling Fujitsu enclosure For each component the following items are displayed For single controller models both controller module 1 and expander module 1 are indicated by hyphens Information is not displayed for drive enclosures that do not exist Part No Part number embedded in the component Serial No Serial number embedded in ...

Page 68: ... IOM 0 CA07111 C661 PP085100Z9 AA DE 3 IOM 1 CA07111 C661 PP085100ZD AA DE 3 PSU 0 CA05954 0860 FA09050024 06A DE 3 PSU 1 CA05954 0860 FA09050025 06A DE 4 IOM 0 CA07111 C661 PP085100Z0 AA DE 4 IOM 1 CA07111 C661 PP085100YZ AA DE 4 PSU 0 CA05954 0860 FA09040009 06A DE 4 PSU 1 CA05954 0860 FA09040011 06A DE 5 IOM 0 CA07111 C661 PP085102T0 AA DE 5 IOM 1 CA07111 C661 PP085102T1 AA DE 5 PSU 0 CA05954 0...

Page 69: ... for Thin provisioning pool management Creating a Thin provisioning pool Deleting Thin provisioning pools Changing an existing Thin provisioning pool Expanding a Thin provisioning pool Formatting a Thin provisioning pool Summary of Thin provisioning pools settings through CLI The steps involved in setting the Thin provisioning pools TPP using CLI are as follows Procedure 1 License management Befor...

Page 70: ...ovisioning Volume TPV management Prepare a TPP and a TPV A TPV can be created from a TPP A TPV can be created in the same way as a normal volume is created by using the create volume command It can be delete using the delete volume command When expanding a volume use the expand volume command End of procedure The following figure shows the relationship between TPPs and TPVs A TPP can be deleted by...

Page 71: ...2X0 1030 09ENZ0 71 set thin pro license This command registers the Thin provisioning license Syntax Parameter Example s set thin pro license key key key This parameter specifies the Thin provisioning license key The license key length is 16 letters fixed The following example registers the Thin provisioning license CLI set thin pro license key 8628569802345756 ...

Page 72: ... be deleted in the following situations When the Thin provisioning license is not registered When a Thin provisioning pool is registered delete thin pro license execution yes no execution This parameter confirms that the operation should proceed The Thin provisioning license is deleted only when yes is specified for this parameter yes The already registered Thin provisioning license is deleted no ...

Page 73: ...gistration status of the Thin provisioning license Syntax Parameter No parameters Output Example s show thin pro license Thin provisioning License Registered A A The registration status of Thin provisioning license The following example displays the registration status of the Thin provisioning license CLI show thin pro license Thin provisioning License Registered CLI show thin pro license Thin pro...

Page 74: ...ias name of a Thin provisioning pool Only one name can be specified For details refer to 1 2 4 Alias Name Syntax page 20 attribute This parameter specifies the disk attribute of a Thin provisioning pool online Online disks nearline Nearline disks ssd SSDs sed SEDs level This parameter specifies the RAID level 0 RAID0 1 RAID1 5 RAID5 6 RAID6 10 RAID1 0 warning Optional This parameter specifies the ...

Page 75: ... calculated automatically by the system is assigned If this parameter is omitted auto mode is selected For the ETERNUS DX80 S2 DX90 S2 0 Controller module 0 1 Controller module 1 auto Automatically default For the ETERNUS DX410 S2 DX440 S2 and ETERNUS DX8100 S2 cm0cpu0 Controller module 0 CPU 0 cm0cpu1 Controller module 0 CPU 1 cm1cpu0 Controller module 1 CPU 0 cm1cpu1 Controller module 1 CPU 1 au...

Page 76: ...lected The available values vary depending on the RAID level and the number of drives When auto is specified for the rg mode parameter only 64kb can be specified 64kb 64k Byte 128kb 128k Byte Only for RAID 5 configurations of 10 or more disks RAID0 configurations and RAID1 0 configurations 256kb 256k Byte Only for RAID 5 configurations of 9 or less disks RAID0 configurations and RAID1 0 configurat...

Page 77: ...s parameter is omitted the name is not changed For details refer to 1 2 4 Alias Name Syntax page 20 warning Optional This parameter specifies the warning level of the Thin provisioning pool The settable range is 5 99 If this parameter is omitted the warning level is not changed The warning level range should be equal to or higher than the attention setting range attention Optional This parameter s...

Page 78: ...ing pool must be deleted before the Thin provisioning pool is deleted Syntax Parameter Example s delete thin pro pool pool number pool_numbers pool name pool_names pool number or pool name This parameter specifies the Thin provisioning pool identifiers One or more Thin provisioning pool identifiers can be specified For details refer to 1 2 5 Thin Provisioning Pool Syntax page 20 The following exam...

Page 79: ...tal Used Used warn Atten Encryp No Name attribute Level Capa Capa status ing tion tion 00 TPP01 Online RAID1 0 Available 100 TB 50 MB Normal 80 60 Enable A B C D E F G H I J K Raid Group List Raid Group RAID Assigned Status Total Free Stripe No Name Level CM Capa Capa Depth 01 RG001 RAID1 0 CM 0 Spare in Use 500TB 250GB 128KB 02 RG002 RAID1 0 CM 1 Available 500TB 250GB 128KB L M N O P Q R S A Thin...

Page 80: ... example displays the details of the Thin provisioning pool named TPP001 CLI show thin pro pools Thin Pro Disk RAID Status Total Used Alarm warn Atten Encryp No Name attribute Level Capacity Capacity status ing tion tion 00 TPP01 Online RAID1 0 Available 95 25 GB 0 00 MB Normal 80 60 Enable Raid Group List RAID Group RAID Assigned Status Total Free No Name Level CM Capacity Capacity 1 RG001 RAID1 ...

Page 81: ...Thin Provisioning Pool Syntax page 20 If the Thin provisioning pool identifier is omitted a progress list of all the Thin provisioning pool is displayed Thin Pro Status Format No Name Progress 0 TPP01 Available 30 1 TPP02 Available 50 A B C D A A Thin provisioning pool number B A Thin provisioning pool name C Thin provisioning pool status D Format progress The following example displays a list of ...

Page 82: ...RNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 82 The following example displays the progress status of the Thin provisioning pools named TPP001 and TPP002 CLI show thin pro pool progress rg name TPP001 TPP002 Thin Pro Status Format No Name Progress 0 TPP001 Available 30 1 TPP002 Available 50 ...

Page 83: ...automatically allocated The capacity of the disk is specified with the capacity parameter manual The disk is manually allocated The disk is specified with the disks parameter disks Optional This parameter specifies which disks are used to configure the RAID group This parameter can only be specified when rg mode manual is selected One or more disks can be specified at the same time For details ref...

Page 84: ... module 2 CPU 0 cm2cpu1 Controller module 2 CPU 1 cm3cpu0 Controller module 3 CPU 0 cm3cpu1 Controller module 3 CPU 1 cm4cpu0 Controller module 4 CPU 0 cm4cpu1 Controller module 4 CPU 1 cm5cpu0 Controller module 5 CPU 0 cm5cpu1 Controller module 5 CPU 1 cm6cpu0 Controller module 6 CPU 0 cm6cpu1 Controller module 6 CPU 1 cm7cpu0 Controller module 7 CPU 0 cm7cpu1 Controller module 7 CPU 1 auto Autom...

Page 85: ...in Provisioning Pool Syntax page 20 mode This parameter specifies the range of the format all All the areas are formatted all of the data is deleted unformatted Unformatted areas are formatted When there are no unformatted areas the command ends normally no action from the command is performed When the mode all parameter is specified to format all of the areas all of the existing data is deleted N...

Page 86: ...e settings refer to 3 3 3 ECO Management page 128 Summary of Thin provisioning pool ECO settings through CLI Setting of the Thin provisioning pools TPP with ECO using CLI are as follows Procedure 1 Assign the ECO mode to a TPP To assign an ECO mode schedule to TPP use the set eco thin pro pool command To check the ECO mode schedule use the show eco thin pro pool command An ECO mode schedule can be...

Page 87: ...or details refer to 1 2 5 Thin Provisioning Pool Syntax page 20 schedule number or schedule name Optional This parameter specifies an ECO schedule identifier Only one ECO schedule number can be specified If omitted the existing setting is not changed For details refer to 1 2 13 ECO Schedule Syntax page 25 action This parameter specifies whether the associated definition is enabled enable The assoc...

Page 88: ...8 The following example associates ECO schedule 1 with the Thin provisioning pool named TPP001 The second command associates the ECO schedule 2 with the same Thin provisioning pool executions result in ECO schedule 1 being released CLI set eco thin pro pool pool name TPP001 schedule number 1 action enable CLI set eco thin pro pool pool name TPP001 schedule number 2 action enable ...

Page 89: ...ol number pool_numbers pool name pool_names pool number or pool name This parameter specifies the Thin provisioning pool identifiers One or more Thin provisioning pool identifiers can be specified For details refer to 1 2 5 Thin Provisioning Pool Syntax page 20 The following example releases an ECO schedule associated with the Thin provisioning pool named TPP001 CLI release eco thin pro pool pool ...

Page 90: ... Thin provisioning pool Online Nearline D Reliability of the Thin provisioning pool High Middle None E Thin provisioning pool status F ECO schedule action Whether the ECO schedule is associated is displayed G ECO schedule number In the case of a schedule by a cooperative software 128 is displayed H ECO schedule name In the case of a schedule by a cooperative software External is displayed I Curren...

Page 91: ...IMITED P2X0 1030 09ENZ0 91 3 2 Flexible Tier Management 3 2 1 Flexible Tier Pools This section explains the commands used for Flexible Tier Pool FTRP management Deleting FTRPs Changing an existing Flexible Tier Sub Pool FTSP For details about Flexible Tier Volume FTV management refer to 3 4 2 Flexible Tier Volumes page 175 ...

Page 92: ...mand displays the setting status of the Flexible Tier function Syntax Parameter No parameters Output Example s show flexible tier mode Flexible Tier Mode Enable A A It shows whether the Flexible Tier function is enabled The following example displays the setting status of the Flexible Tier function CLI show flexible tier mode Flexible Tier Mode Disable CLI show flexible tier mode Flexible Tier Mod...

Page 93: ...lso deleted If a volume is registered in the specified FTRP the FTRP cannot be deleted Syntax Parameter Example s Delete all volumes in the target FTRP before deleting the FTRP delete flexible tier pool ftrp number ftrp_number ftrp name ftrp_name ftrp number or ftrp name This parameter specifies the FTRP identifiers that are to be deleted Multiple FTRPs can be deleted in a single command The follo...

Page 94: ... displayed Syntax Parameter Output show flexible tier pools ftrp number ftrp_number ftrp name ftrp_name ftrp number or ftrp name Optional This parameter specifies the FTRP identifier to display detailed information for Multiple parameters can be selected in a single command If omitted a list of all the FTRPs that are already registered in the ETERNUS DX Disk storage system is displayed When the pa...

Page 95: ...mber K Flexible Tier Sub Pool name L Disk attribute that composes the Flexible Tier Sub Pool Online Nearline SSD M RAID Level N Flexible Tier Sub Pool status O Total capacity of the Flexible Tier Sub Pool P Used capacity of the Flexible Tier Sub Pool The following example displays an overview list of the FTRPs that are already registered in the ETERNUS DX Disk storage system CLI show flexible tier...

Page 96: ...etailed information for FTRP 00 CLI show flexible tier pools ftrp number 0 Flexible Tier Pool Status Total Used Used Warn Atten Encryp No Name Capacity Capacity Status ing tion tion 0 FTRP001 Available 129 00 GB 0 00 MB Normal 90 75 Disable Flexible Tier Sub Pool List Flexible Tier Sub Pool Disk RAID Status Total Used No Name Attribute Level Capacity Capacity 0 FTSP Online RAID0 Available 129 00 G...

Page 97: ...e already registered in the ETERNUS DX Disk storage system is displayed Syntax Parameter Output show flexible tier pool progress ftrp number ftrp_number ftrp name ftrp_name ftrp number or ftrp name Optional This parameter specifies the FTRP identifier to display detailed information for Multiple parameters can be selected in a single command If omitted a list of all the FTRPs that are already regi...

Page 98: ...ailable 99 The following example displays the progress rate of formatting for an FTRP that is named FTRP001 CLI show flexible tier pool progress ftrp name FTRP001 Flexible Tier Pool Status No Name 1 FTRP001 Available Flexible Tier Sub Pool List Flexible Tier Sub Pool Status Format No Name Progress 4 FTSP0004 Available 50 The following example displays the progress rate of formatting for FTRP 00 an...

Page 99: ...6cpu0 cm6cpu1 cm7cpu0 cm7cpu1 auto ftsp number or ftsp name This parameter specifies the FTSP identifier Only one FTSP identifier can be specified in a single command assigned cm Optional This parameter specifies the assigned CM for the RAID group that is added to the target FTSP When auto is specified the assigned CM is automatically determined by the ETERNUS DX Disk storage system If omitted the...

Page 100: ...ntroller module 2 CPU 0 cm2cpu1 Controller module 2 CPU 1 cm3cpu0 Controller module 3 CPU 0 cm3cpu1 Controller module 3 CPU 1 cm4cpu0 Controller module 4 CPU 0 cm4cpu1 Controller module 4 CPU 1 cm5cpu0 Controller module 5 CPU 0 cm5cpu1 Controller module 5 CPU 1 cm6cpu0 Controller module 6 CPU 0 cm6cpu1 Controller module 6 CPU 1 cm7cpu0 Controller module 7 CPU 0 cm7cpu1 Controller module 7 CPU 1 au...

Page 101: ...tsp number ftsp_number ftsp name ftsp_name ftrp number or ftrp name Optional This parameter specifies the FTSP identifier to display detailed information for Multiple parameters can be selected in a single command If omitted a list of all the FTSPs that are already registered in the ETERNUS DX Disk storage system is displayed When the parameter is omitted Flexible Tier Sub Pool Flexible Tier Pool ...

Page 102: ...ity of the Flexible Tier Sub Pool I Used capacity of the Flexible Tier Sub Pool J RAID Group number K RAID Group name L RAID Level M Assigned CM N RAID Group status O Total capacity of RAID Group P Used capacity of RAID Group Q Stripe depth The following example displays an overview list of the Flexible Tier Sub Pools that are already registered in the ETERNUS DX Disk storage system CLI show flexi...

Page 103: ...sp number 10 Flexible Tier Sub Pool Flexible Tier Pool Disk RAID Status Total Used No Name No Name Attribute Level Capacity Capacity 10 FTSP0010 0 FTRP000 Nearline RAID5 Available 500 GB 250 GB Raid Group List Raid Group RAID Assigned Status Total Used No Name Level CM Capacity Capacity 1 RLI001 RAID5 CM 0CPU 0 Available 250 GB 150 GB 10 RLI010 RAID5 CM 0CPU 0 Available 100 GB 75 GB 53 RLI053 RAID...

Page 104: ...igration command to check the status of FTRPE Migration End of procedure Only user accounts with the Software Control policy can execute FTRPE Migration and check the status of FTRPE Migration User accounts without the Software Control policy cannot use the FTRPE Migration function FTRPE Migration uses the same session table that is used by RAID Migration Flexible Tier Migration and Thin Provision...

Page 105: ...e No Name Start LBA No Name 7 2 FTSP0002 Active 50 0x05 6 RLU006 0x0010000000000000 3 FTV0003 A B C D E F G H I J K A The move FTRPE ID B The move destination Flexible Tier Sub Pool number C The move destination Flexible Tier Sub Pool name D The FTRPE migration status E The FTRPE migration progress F The FTRPE migration error code G The move source RAID Group number H The move source RAID Group na...

Page 106: ... 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 106 3 2 3 FTV Balancing This section explains the commands that are used for balancing Flexible Tier Volume FTV allocation among RAID groups Starting Flexible Tier Volume balancing Stopping Flexible Tier Volume balancing Checking the Flexible Tier Volume balancing status ...

Page 107: ...e Flexible Tier Volumes FTVs among RAID groups Specify the FTRP that is to be balanced Syntax Parameter Example s start balancing flexible tier pool ftrp number ftrp_number ftrp name ftrp_name ftrp number or ftrp name This parameter specifies the FTRP to which the FTV to start balancing is allocated For details refer to 1 2 6 Flexible Tier Pool Syntax page 21 The following example starts balancing...

Page 108: ...e Flexible Tier Volumes FTVs among RAID groups Specify the FTRP that is being balanced Syntax Parameter Example s stop balancing flexible tier pool ftrp number ftrp_number ftrp name ftrp_name ftrp number or ftrp name This parameter specifies the FTRP to which the FTV to stop balancing is allocated For details refer to 1 2 6 Flexible Tier Pool Syntax page 21 The following example stops balancing FT...

Page 109: ...cifies which FTRP to display the balancing information for Only one FTRP can be specified at the same time If omitted the balancing information of all the FTRPs that are registered in the ETERNUS DX Disk storage system is displayed For details refer to 1 2 6 Flexible Tier Pool Syntax page 21 When the parameter is omitted Flexible Tier Pool Balancing Balancing Process Error No Name Level Status Pro...

Page 110: ...ocess status error 0x00 is displayed when no error occurs during balancing and a hyphen is displayed when balancing is not being performed G FTSP number This item only appears when an FTRP is specified H FTSP name This item only appears when an FTRP is specified I Balancing level High Medium Low of each FTSP This item only appears when an FTRP is specified The following example displays the balanc...

Page 111: ...ed for the following settings RAID group settings Hot spares settings ECO mode settings 3 3 1 RAID Group This section explains the commands used for RAID group management All disks contained in a RAID group must be the same disk type The functions to control RAID groups are as follows Creating a RAID group Deleting RAID groups Changing an existing RAID group LDE Logical Device Expanding expanding ...

Page 112: ...a RAID group Only one name can be specified For details refer to 1 2 4 Alias Name Syntax page 20 disks This parameter specifies which disks will form the RAID group For details refer to 1 2 3 Disk Syntax page 19 level This parameter specifies the RAID level 0 RAID0 1 RAID1 5 RAID5 6 RAID6 10 RAID1 0 50 RAID5 0 assigned cm Optional This parameter specifies the assigned controller CM number of the s...

Page 113: ...le 7 CPU 0 cm7cpu1 Controller module 7 CPU 1 auto Automatically default stripe depth Optional This parameter specifies the stripe depth for the RAID group that is to be created If omitted then it is handled as if 64kb is selected The available values vary depending on the RAID level and the number of drives 64kb 64k Byte 128kb 128k Byte Only for RAID 5 configurations of 10 or more disks RAID 0 con...

Page 114: ...up identifiers can be specified when changing the assigned CM For details refer to 1 2 8 RAID Group Syntax page 22 name Optional This parameter specifies the new RAID group name If this parameter is omitted the name is not changed For details refer to 1 2 4 Alias Name Syntax page 20 assigned cm Optional This parameter specifies the assigned controller module number of the RAID group If auto is spe...

Page 115: ... cm7cpu0 Controller module 7 CPU 0 cm7cpu1 Controller module 7 CPU 1 auto Automatically default key group Optional This parameter specifies whether to use the key group If omitted the existing setting is not changed enable The key group is used the SED authentication key that is managed by the key server is used disable The key group is not used the common key in the ETERNUS DX Disk storage system...

Page 116: ...Display 3 3 RAID Group Management set raid group ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 116 The following example sets a key group for RAID groups 2 and 4 CLI set raid group rg number 2 4 key group enable ...

Page 117: ...not be deleted until the expansion process is complete All volumes in a specified RAID group must be deleted before the RAID group is deleted delete raid group rg number rg_numbers rg name rg_names rg number or rg name This parameter specifies RAID group identifiers One or more RAID group identifiers can be specified For details refer to 1 2 8 RAID Group Syntax page 22 The following example delete...

Page 118: ...Status Total Free Stripe Key No Name Level CM Capacity MB Capacity MB Depth KB Group 1 RAIDGROUP001 RAID1 0 CM 0 Spare in Use 134656 132535 1024 Enable A B C D E F G H I Disk List Disk Status Usage Mirroring CE Disk 3 Available Data CE Disk 5 J K L M A A RAID group number B A RAID group name C A RAID level D Assigned CM number CM number to control a RAID group E RAID group status F Total capacity ...

Page 119: ...t has failed CLI show raid groups rg name R1 RAID Group RAID Assigned Status Total Free Stripe Key No Name Level CM Capacity MB Capacity MB Depth KB Group 0 R1 RAID5 CM 0 Broken 1116160 1116136 64 Enable Disk List Disk Status Usage CE Disk 0 Available System CE Disk 1 Available System CE Disk 2 Available Data CE Disk 3 Broken Data CE Disk 4 Broken Data CE Disk 5 Broken Dedicated Hot Spare CE Disk ...

Page 120: ...fer to 1 2 8 RAID Group Syntax page 22 RAID Group Status Rebuild Copyback Expanding No Name Progress Progress 0 RAIDGROUP001 Copyback 87 1 RAIDGROUP012 Available 19 A B C D E A A RAID group number B A RAID group name C RAID group status D Progress status of Rebuild Copyback E Progress status of expanding RAID groups Logical Device Expansion The following example displays a progress list of all the...

Page 121: ...015 FUJITSU LIMITED P2X0 1030 09ENZ0 121 The following example displays the progress status of the RAID group named RAIDGROUP001 and RAIDGROUP012 CLI show raid group progress rg name RAIDGROUP001 RAIDGROUP012 RAID Group Status Rebuild Copyback Expanding No Name Progress Progress 0 RAIDGROUP001 Copyback 87 1 RAIDGROUP012 Available 19 ...

Page 122: ...re to be added must be specified for the disks parameter expand raid group rg number rg_number rg name rg_name disks disks level 0 5 6 10 name name rg number or rg name This parameter specifies a RAID group identifier Only one RAID group identifier can be specified For details refer to 1 2 8 RAID Group Syntax page 22 disks This parameter specifies the disks to add to a RAID group One or more param...

Page 123: ...ares There are two types of hot spares Global Hot Spare Global HS A hot spare that can be used by all RAID groups except RAID0 Dedicated Hot Spare Dedicated HS DHS A hot spare that can be used by one specific RAID group Hot spares must be of the same disk type and must have the same or larger capacity as the disks in the assigned RAID group A list of registered hot spare disks can be displayed by ...

Page 124: ...ed by using the show disks command Syntax Parameter Example s set global spare disks disks disks This parameter specifies the disks to be registered as Global Hot Spares One or more disks can be specified For details refer to 1 2 3 Disk Syntax page 19 The following example registers disks 101 and 102 as Global Hot Spares CLI set global spare disks 101 102 In the following example disks 101 and 102...

Page 125: ...nassigned present status Syntax Syntax Example s release global spare disks disks disks This parameter specifies the disks to be released from the Global Hot Spare One or more disks can be specified For details refer to 1 2 3 Disk Syntax page 19 The following example releases disk 011 from the Global Hot Spares CLI release global spare disks 011 The following example releases disks 101 to 105 from...

Page 126: ...ifies the RAID group identifiers to which the Dedicated Hot Spares will be assigned One or more RAID group identifiers can be specified If two or more RAID group identifiers are specified they must be specified in the same order as the associated disk parameters For details refer to 1 2 8 RAID Group Syntax page 22 The example assigns disk 110 as a dedicated hot spare to the RAID group R1 CLI set d...

Page 127: ...have an unassigned present status Syntax Parameter Example s release dedicated spare disks disks disks This parameter specifies the disks that are registered as Dedicated Hot Spares One or more disks can be specified For details refer to 1 2 3 Disk Syntax page 19 The following example releases Dedicated Hot Spare 110 CLI release dedicated spare disks 110 The following example releases Dedicated Ho...

Page 128: ...CO Management This section explains the commands that are related to the ECO functions They are only applicable when the ECO mode is enabled using the set eco mode command The three steps involved in enabling the ECO functions are as follows Procedure 1 Enable the ECO mode 2 Create an ECO schedule 3 Assign the ECO schedule to RAID groups End of procedure ...

Page 129: ...isk motor when the disks are not being accessed The ECO function cannot be used unless the ECO mode is enabled Syntax Parameter Example s set eco mode mode enable disable mode Optional This parameter specifies if the ECO mode is enabled If omitted the existing setting is not changed enable ECO mode is enabled disable ECO mode is disabled The following example enables the ECO mode CLI set eco mode ...

Page 130: ... Syntax Parameter No parameters Output Example s show eco mode CLI show eco mode Mode Enable A Host I O Monitoring Time 60 min B Disk Motor Control Limit Count 5 C A ECO mode B The monitoring interval time of the host I O C The number of times that a disk motor will power off and on in one day The following example displays the current ECO mode settings CLI show eco mode Mode Enable Host I O Monit...

Page 131: ...vent 8 Schedule Event 5 Schedule Event 6 Schedule Event 2 Schedule Event 3 Schedule Event 4 create eco schedule name schedule_name event type every day every week mon tue wed thu fri sat sun mon tue wed thu fri sat sun specific day MMDD R specific week MM 1st 2nd 3rd 4th last mon tue wed thu fri sat sun mon tue wed thu fri sat sun event from hhmm event to hhmm name This parameter specifies the ECO...

Page 132: ...as R and a value between 1 7 can be set Example event type specific day 0501 3 For three days from May 1st to May 3rd Example event type specific day 0630 2 For two days from June 30th to July 1st specific week The ECO schedule is applied to a specific week This format is specific week MM W STA END The specific month MM 01 12 and the specific week W 1st 2nd 3rd 4th or last are separated by a comma...

Page 133: ...ting hour 00 23 and mm is the starting minute 00 or 30 A disk motor will power ON at the time specified by this parameter event to This parameter specifies that the ECO schedule will end at a specific time The format is hhmm hh is the ending hour 00 23 and mm is the ending minute 00 or 30 The following example creates an ECO schedule The ECO schedule name is SC001 The ECO schedule will apply every...

Page 134: ...ax page 20 event number Optional This parameter specifies the ECO schedule event number to change or to add the ECO schedule event to the ECO schedule The ECO schedule event number is a value from 1 to 8 Only one number can be specified The ECO schedule event number can be displayed by using the show eco schedule command If omitted the ECO schedule event specified by this parameter value is not ch...

Page 135: ...rmat is specific week MM W STA END The specific month MM 01 12 and the specific week W 1st 2nd 3rd 4th or last are separated by a comma when every month is required specify em instead of 01 12 The start day of the week STA and the end day of the week END are separated by a comma The day of the week must be specified in the following format The end day of the week must be after the start day of the...

Page 136: ...me The format is hhmm hh is the ending hour 00 23 and mm is the ending minute 00 or 30 If omitted the existing setting is not changed The following example adds ECO schedule event 2 in the ECO schedule named SC001 CLI set eco schedule schedule name SC001 event number 2 event type every day event from 0600 event to 1800 The following example changes the ECO schedule name The new ECO schedule name i...

Page 137: ... if an event number is also specified then only one ECO schedule identifier can be specified For details refer to 1 2 13 ECO Schedule Syntax page 25 event number Optional This parameter specifies the ECO schedule event number to be deleted The ECO schedule event number is a value from 1 to 8 and can be displayed by using the show eco schedule command Only one event number can be specified If the e...

Page 138: ... ECO schedule identifier to display details One or more ECO schedule identifiers can be specified If this parameter is omitted all the ECO schedules are displayed For details refer to 1 2 13 ECO Schedule Syntax page 25 ECO Schedule No Name 0 SC001 A B Event No Type Details Time 1 Specific week December 1st week Monday Friday from 06 00 to 18 00 C D E F G A An ECO schedule number B An ECO schedule ...

Page 139: ...18 00 3 Specific day 6days from December 13 from 06 00 to 18 00 4 Specific week December 1st week Monday Friday from 06 00 to 18 00 The following example displays the schedule information of the ECO schedules named SC002 and SC003_TEMP at the same time CLI show eco schedule schedule name SC002 SC003_TEMP ECO Schedule No Name 2 SC002 Event No Type Details Time 1 Every day from 06 00 to 18 00 2 Ever...

Page 140: ...This parameter specifies an ECO schedule identifier Only one ECO schedule number can be specified If omitted the existing setting is not changed For details refer to 1 2 13 ECO Schedule Syntax page 25 To set software linkage specify 128 for schedule number In this case External is automatically set as the schedule name action This parameter specifies whether the associated definition is enabled en...

Page 141: ...ENZ0 141 The following example associates ECO schedule 1 with the RAID group named RGP001 The second command associates the ECO schedule 2 with the same RAID group These executions result in ECO schedule 1 being released CLI set eco raid group rg name RGP001 schedule number 1 action enable CLI set eco raid group rg name RGP001 schedule number 2 action enable ...

Page 142: ...mple s release eco raid group rg number rg_numbers rg name rg_names rg number or rg name This parameter specifies a RAID group identifiers One or more parameters can be specified For details refer to 1 2 8 RAID Group Syntax page 22 The following example releases an ECO schedule associated with the RAID group named RGP001 CLI release eco raid group rg name RGP001 The following example releases an E...

Page 143: ...D group F RAID group capacity G An ECO schedule action It means whether the ECO schedule is associated or not H An ECO schedule number In the case of a schedule by a cooperative software 128 is displayed I An ECO schedule name In the case of a schedule by a cooperative software External is displayed J Current status of a Disk motor K Determent status by a control command The following example disp...

Page 144: ... volumes Flexible Tier Volumes FTVs that are assigned to Flexible Tier Pools FTRPs refer to 3 4 2 Flexible Tier Volumes page 175 3 4 1 Volume This section explains the details of the commands that are related to the management of volumes Creating volumes Deleting volumes Changing existing volume information Formatting volumes Encrypting volumes LUN concatenation expanding volumes RAID migration mo...

Page 145: ...ide stripe size normal small concatenation order auto manual volume number volume_number name This parameter specifies a volume name For details refer to 1 2 4 Alias Name Syntax page 20 rg number or rg name This parameter specifies a RAID group identifier to create new volumes Note that multiple RAID groups can be specified when type wsv is set For details refer to 1 2 8 RAID Group Syntax page 22 ...

Page 146: ...maller than or equal to 2TB can be specified SDPV must be specified in units of GB If max is specified volumes are created in the largest free space of the RAID group The number of volumes that is created is the value that is specified for the count parameter For standard type volumes the volume capacity is determined so that the capacity of each created volume is equal and is a multiple of the ba...

Page 147: ...tion attention Optional This parameter specifies the attention level of the Thin provisioning volume TPV This parameter can be specified when the type tpv parameter is specified The settable range is 1 200 If this parameter is omitted attention is not changed encryption Optional This parameter specifies whether the encryption by a CM is performed When enable is selected the specified volume data i...

Page 148: ...me RGP001 type standard size 20gb The following example creates a volume named SDV1 in the RAID group named RGP002 The volume type is SDV the physical size is 20GB and the logical size is 100GB CLI create volume name SDV1 rg name RGP002 type sdv size 20gb virtual size 100gb The following example creates a volume named SDPV ALL in RAID group 11 The volume type is SDPV and the pool size is 1GB CLI c...

Page 149: ...existing setting is not changed For details refer to 1 2 4 Alias Name Syntax page 20 copy protection Optional This parameter protects a volume from being specified for the copy destination It is possible to set it even when there is already a copy session The copy license is necessary for this setting If this parameter is omitted disable is set enable Volume is protected at the copy destination di...

Page 150: ...0 Example s The following example changes the volume named VOL003 The new name is VOLUME003 CLI set volume volume name VOL003 name VOLUME003 The following example changes the volume named VOL003 to VOLUME003 enables copy protection and changes the attention level to 80 CLI set volume volume name VOL003 name VOLUME003 copy protection enable attention 80 ...

Page 151: ...ID migration must be stopped before a specified volume is deleted Advanced Copy sessions to be deleted must be stopped before specified volume is deleted The delete flexible tier volume command is used to delete Flexible Tier Volumes FTVs Syntax Parameter Example s delete volume volume number volume_numbers volume name volume_names volume number or volume name This parameter specifies the volume i...

Page 152: ...exible Tier Pool FTRP Syntax Parameter Example s delete all volumes rg number rg_number rg name rg_name pool number pool_number pool name pool_name rg number or rg name This parameter specifies the RAID group identifiers to delete all the volumes contained in the RAID groups Only one RAID group can be specified at the same time For details refer to 1 2 9 Volume Syntax page 22 This parameter cannot...

Page 153: ...ber or rg name Optional This parameter specifies RAID group identifiers The details of the volumes in a RAID group will be displayed If the RAID group identifier is omitted a summary of all the volumes that exist in the system is displayed For details refer to 1 2 8 RAID Group Syntax page 22 Only one parameter can be specified Other parameters except for mode default cannot be specified at the sam...

Page 154: ...21 Only one parameter can be specified Other parameters except for mode default and mode ftv cannot be specified at the same time type Optional This parameter specifies the volume type to display the specific type If the volume type is omitted it is handled as selecting all types Only one parameter can be specified Other parameters except for mode default cannot be specified at the same time stand...

Page 155: ... an FTV Usage Rate indicates Volume Used Capacity total capacity of all the FTVs 100 The result for this formula is rounded down to the nearest whole number This may result in the sum of the displayed Usage Rate values not being 100 even when the actual value is 100 When no FTSPs are used the Usage Rate is 0 default The same result as when this parameter is omitted Volume Status Type Encryption Ex...

Page 156: ...e RAID group named RGP011 Free space information is also displayed CLI show volumes rg name RGP011 Volume Status Type RG or TPP Size MB Copy No Name No Name protection Available MLU 11 RGP011 Available MLU 11 RGP011 Available MLU 11 RGP011 The following example only displays a list of SDPV type volumes CLI show volumes type sdpv Volume Status Type Encryption Expansion RG or TPP or FTRP Size MB Res...

Page 157: ...P Size MB UID No Name No Name 1 VOL001 Available Standard 10 RGP010 32768 12345678901234567890123456789012 The following example displays information on an FTV CLI show volumes mode ftv Volume Status Type Encryption RG or TPP or FTRP Size MB Copy Used Measurements Priority Attention Used No Name No Name Protection Status Capacity MB 9 FTV009 Available FTV ON 01 FTRP001 1024 disable Normal 100 70 0...

Page 158: ...rs One or more parameters can be specified at the same time If the volume identifier is omitted the progress status of all the volumes is displayed For details refer to 1 2 9 Volume Syntax page 22 show volume progress volume number 1 Volume Status Formatting Migrating Encrypting Balancing Zero Reclamation No Name Progress Progress Progress Progress Progress 1 VOL001 Available 100 A B C D E F G H A...

Page 159: ...12 Volume Status Formatting Migrating Encrypting Balancing Zero Reclamation No Name Progress Progress Progress Progress Progress 1 VOL001 Available 80 12 VOL012 Rebuild 80 The following example displays the progress status of all the volumes CLI show volume progress Volume Status Formatting Migrating Encrypting Balancing Zero Reclamation No Name Progress Progress Progress Progress Progress 1 VOL00...

Page 160: ...ed the progress status of all the volumes is displayed For details refer to 1 2 9 Volume Syntax page 22 mode Optional This parameter toggles the extended output mode If the mode is omitted default is set all In addition to the normal display items the information of the LUNs that can be accessed from the host of each connected CA port is also displayed host lun Only the information of the LUNs tha...

Page 161: ...rt No Name 0 0 LG 0 0 1 LG 1 The following example displays the information of only the LUNs for volume 0 that can be accessed from the host CLI show volume mapping mode host lun volume number 0 No Name Type UID 0 OLU 0 Standard 600000000100000002A2AAA00000000 Host LUN LUN Port Host Affinity LUN Group No Name No Name 0 CM 0 CA 0 Port 0 0 LG 0 100 CM 0 CA 0 Port 1 0 CM 0 CA 1 Port 0 0 FC 0 0 LG 0 T...

Page 162: ...ax Parameter Example s format volume volume number volume_numbers volume name volume_names volume number or volume name This parameter specifies the volume identifiers to be formatted One or more RAID groups can be specified at the same time For details refer to 1 2 9 Volume Syntax page 22 The following example only formats the volume named VOL001 CLI format volume volume name VOL001 The following...

Page 163: ...he RAID group identifiers to which the volume will belong after expansion One or more RAID groups can be specified at the same time up to a maximum of 15 If two or more RAID groups are specified they must be specified in the same order as the expansion size parameter For details refer to 1 2 8 RAID Group Syntax page 22 This parameter cannot be specified for a Thin provisioning volume TPV This para...

Page 164: ...0 09ENZ0 164 The following example expands the volume named VOL001 as a new 800GB area in RAID group 5 and a new 400GB area in RAID group 6 CLI expand volume volume name VOL001 rg number 5 6 size 800gb 400gb The following example expands the Thin provisioning volume named TPV001 as a new 800GB area CLI expand volume volume name TPV001 size 800gb ...

Page 165: ...r pool name This parameter specifies a RAID group or Thin provisioning pool as the volume migration destination Only one Thin provisioning pool can be specified at the same time Use the rg number or the rg name parameter to specify the RAID group as the migration destination Note that when multiple RAID groups are specified the migration destination becomes a Wide Stripe Volume Use the pool number...

Page 166: ...parameter specifies the Wide Stripe Size of a migration source Wide Striping Volume This parameter can only be specified when the migration source is a Wide Striping Volume If omitted then it is handled as if normal is selected normal The Wide Stripe Size for the Wide Striping Volume is set to 16MB small The Wide Stripe Size for the Wide Striping Volume is set to 2MB Note that if the Stripe Size o...

Page 167: ...d is also used for RAID Migration in which the destination is a Flexible Tier Pool FTRP Syntax Parameter Example s stop migration volume number volume_numbers volume name volume_names volume number or volume name This parameter specifies the migration source volume numbers or names corresponding to an already started migration Details can be displayed using the show migration command One or more p...

Page 168: ...ration Source Volume Migration Progress Error Work Volume No Name Status Code No 7 vol0007 Active 50 0x05 6 A B C D E F A The move source volume number B The move source volume name C The volume migration status D The volume migration progress E The volume migration error code F Working volume number In order to be used as a move destination The following example displays a list of all migrating v...

Page 169: ...elocating the Thin provisioning volumes TPVs among RAID groups Syntax Parameter Example s start balancing thin pro volume volume number volume_number volume name volume_name volume number or volume name This parameter specifies the TPV to start balancing Only one parameter can be specified For details refer to 1 2 9 Volume Syntax page 22 The following example starts balancing TPV01 CLI start balan...

Page 170: ...AID groups Specify the TPV that is being balanced Syntax Parameter Example s stop balancing thin pro volume volume number volume_numbers volume name volume_names volume number or volume name This parameter specifies the TPV to stop balancing One or more parameters can be specified at the same time For details refer to 1 2 9 Volume Syntax page 22 The following example stops balancing TPV01 and TPV0...

Page 171: ...Only one number can be specified For details refer to 1 2 9 Volume Syntax page 22 Example volume number 1 An error occurs when a volume other than a TPV is specified Volume Balancing Balancing Process Work Volume Error Elapsed No Name Level Status Progress No code Time 0 TPV00 High Active 99 1023 0x00 02h34min50sec 1 TPV01 Medium Active 50 2047 0x00 01h23min45sec 2 TPV02 Low Error 30 4095 0x73 00h...

Page 172: ...Elapsed No Name Level Status Progress No code Time 0 TPV00 High Active 99 1023 0x00 02h34min50sec 1 TPV01 Medium Active 50 2047 0x00 01h23min45sec 2 TPV02 Low Error 30 4095 0x73 00h30min30sec The following example displays the specified volume CLI show balancing thin pro volumes volume number 1 Volume Balancing Balancing Process Work Volume Error Elapsed No Name Level Status Progress No code Time ...

Page 173: ...by this command use the stop zero reclamation and show volume progress commands Syntax Parameter Example s start zero reclamation volume number volume_number volume name volume_name volume number or volume name This parameters specifies the volume number or alias name of a volume for which Zero Reclamation is to be started Multiple volumes can be specified in a single command For details refer to ...

Page 174: ...mple s stop zero reclamation volume number volume_number volume name volume_name volume number or volume name This parameters specifies the volume number or alias name of a volume for which Zero Reclamation is to be stopped Multiple volumes can be set in a single command For details refer to 1 2 9 Volume Syntax page 22 The following example stops Zero Reclamation for a TFV that is named FTV0001 CL...

Page 175: ...trol Flexible Tier Volumes are as follows Creating volumes Deleting volumes Changing an existing volume information Formatting volumes Expanding volumes Flexible Tier migration migrating volumes The commands that are used for normal volumes and FTVs are shown below Function Command used for normal volumes Command used for FTVs Creating volumes create volume create flexible tier volume Changing vol...

Page 176: ...or details refer to 1 2 6 Flexible Tier Pool Syntax page 21 size This parameter specifies the FTV size Select whether terabytes TB gigabytes GB or megabytes MB are used for the capacity Example 1tb 120gb 512mb priority Optional This parameter specifies the FTRP number of the Flexible Tier Sub Pool FTSP to which the FTV that is to be created is preferentially allocated If this parameter is omitted ...

Page 177: ...cted disable The FTV is not protected volume number Optional This parameter specifies whether the volume number is assigned automatically or manually Only one volume number can be specified If omitted the volume number is automatically assigned This parameter cannot be specified when a value that is 2 or more is set for the count parameter If an existing volume number is set an error occurs The fo...

Page 178: ...r to 1 2 4 Alias Name Syntax page 20 If omitted the alias name of the target FTV remains unchanged priority Optional This parameter specifies the FTRP number of the Flexible Tier Sub Pool FTSP to which the target FTV is preferentially allocated If auto is specified for this parameter the allocated FTSP is determined automatically If omitted this parameter is not changed attention Optional This par...

Page 179: ...IMITED P2X0 1030 09ENZ0 179 The following example changes the FTSP to which the target FTV is preferentially allocated to volume 03 sets the Attention level threshold to 60 and enables the copy destination volume protection function for volume 02 FTV CLI set flexible tier volume volume number 2 priority 3 attention 60 copy protection enable ...

Page 180: ...er volume volume number volume_numbers volume name volume_names volume number or volume name This parameter specifies the FTV identifiers that are to be formatted Multiple FTVs can be formatted in a single command This command results in an error response if a non FTV volume is specified For details refer to 1 2 9 Volume Syntax page 22 The following example formats an FTV named FTV0001 CLI format ...

Page 181: ...me volume number volume_number volume name volume_name size size tb gb mb volume number or volume name This parameter specifies the volume number or the alias name of the FTVs for which the capacity is to be expanded For details refer to 1 2 9 Volume Syntax page 22 size Optional This parameter specifies the volume size after capacity expansion Select whether terabytes TB gigabytes GB or megabytes ...

Page 182: ...re specified FTVs are deleted Advanced Copy sessions to be deleted must be stopped before specified FTVs are deleted Syntax Parameter Example s delete flexible tier volume volume number volume_numbers volume name volume_names volume number or volume name This parameter specifies the FTV identifiers that are to be deleted Multiple FTVs can be deleted in a single command This command results in an e...

Page 183: ...ied FTVs are deleted All migrating FTVs Flexible Tier migration must be stopped before specified FTVs are deleted Advanced Copy sessions to be deleted must be stopped before specified FTVs are deleted Syntax Parameter Example s delete all flexible tier volumes ftrp number ftrp_numbers ftrp name ftrp_names ftrp number or ftrp name This parameter specifies the FTRP identifier that is allocated to th...

Page 184: ...e_name ftrp number ftrp_number ftrp name ftrp_name priority ftsp_number auto zero reclamation enable disable volume number or volume name This parameter specifies the identifier of the migration source volume For details refer to 1 2 9 Volume Syntax page 22 ftrp number or ftrp name This parameter specifies the FTRP identifier for the volume migration destination Only one parameter can be specified...

Page 185: ... ftrp name FTRP000 The following example migrates OLU Volume 0005 to FTRP 003 and the migrated volumes is preferentially allocated to FTSP 0004 The volume type of Volume 0005 is changed to FTV CLI start flexible tier migration volume number 5 ftrp number 3 priority 4 The following example migrates OLU Volume 0005 to FTRP 003 and the migrated volumes is preferentially allocated to FTSP 0004 The vol...

Page 186: ...eating an ODX Buffer volume Setting an ODX Buffer volume Deleting an ODX Buffer volume The commands that are used for ODX Buffer volumes are shown below Function Command Creating volumes create odx buffer volume Changing volume settings set odx buffer volume Formatting volumes format volume Expanding volumes expand volume Displaying a list of volumes show volumes Displaying the progress of volume ...

Page 187: ...ax Parameter Example s set odx mode mode enable disable mode This parameters specifies whether to enable or disable the Offloaded Data Transfer function enable The Offloaded Data Transfer function is enabled disable The Offloaded Data Transfer function is disabled The following example enables the Offloaded Data Transfer function CLI set odx mode mode enable The following example disables the Offl...

Page 188: ...n mode for the Offloaded Data Transfer function Syntax Parameter No parameters Output Example s show odx mode Offloaded Data Transfer Mode Enable A A Operation mode for the Offloaded Data Transfer function The following example displays the operation mode for the Offloaded Data Transfer function CLI show odx mode Offloaded Data Transfer Mode Disable CLI show odx mode Offloaded Data Transfer Mode E...

Page 189: ... can be set when open or standard are set for the type parameter pool number or pool name This parameter specifies the identifier of the TPP in which the ODX Buffer volume is to be created For details refer to 1 2 5 Thin Provisioning Pool Syntax page 20 This parameter can be specified when tpv is set for the type parameter ftrp number or ftrp name This parameter specifies the identifier of the FTR...

Page 190: ...o encrypt a volume If enable is specified the volume data that is specified is encrypted If this parameter is omitted disable is specified enable The volume data is encrypted disable No operation The following example creates the ODX Buffer volume that is named VOL001 in a RAID group that is named RGP001 The volume size is 1GB CLI create odx buffer volume name VOL001 rg name RGP001 type standard s...

Page 191: ...s only enabled when the type of the ODX Buffer volume is FTV Specify the FTSP number to set the priority for allocating a Flexible Tier Sub Pool FTSP to the target FTV If auto is input the FTSP is automatically allocated If omitted the priority is not changed attention Optional This parameter is only enabled when the type of the ODX Buffer volume is TPV or FTV Specify the threshold attention level...

Page 192: ...ust be stopped Copy sessions for the ODX Buffer volume must be stopped Syntax Parameter Example s delete odx buffer volume volume number volume_number volume name volume_name volume number or volume name This parameter specifies the identifier of the ODX Buffer volume that is to be deleted Only one volume can be specified If a volume other than the ODX Buffer volume is specified an error occurs Fo...

Page 193: ... is as follows Host Affinity Mode There are two mapping methods to associate volumes with host LUNs They should be separated and used depending on whether Host Affinity Mode is enabled Host Affinity Mode can be set to each host interface port respectively When Host Affinity Mode is enabled it can associate an affinity group the definition to associate volumes with host LUNs with the host HBA When ...

Page 194: ...ng is an example when Host Affinity Mode is disabled Procedure 1 Disable the Host Affinity Mode FC 2 Create a RAID group named r1 3 Create volumes named v0 v1 and v2 in the RAID group named r1 4 Use mapping to set the relationship between host interface ports 000 and 001 volumes v0 v1 and v2 and LUNs 0 1 and 2 End of procedure CLI set fc parameters port 000 host affinity enable CLI create raid gro...

Page 195: ...splay 3 5 Host Interface Management ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 195 3 5 1 Host Interface Port Parameters This section explains the commands related to setting up parameters for each host interface ...

Page 196: ...disable rec transfer through enable disable port This parameter specifies the FC interface port number to be set up Two or more parameters can be specified by separating them with a comma Example port 000 110 For details refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the FC port number Example 123 indicates CM 1 CA 2 Port 3 a...

Page 197: ...automatically assigns descending order manual It assigns manually loop id Optional This parameter specifies the loop ID a hexadecimal number This is only applicable when loop id assign manual is specified The range of values is between 0x00 and 0x7d a hexadecimal number If omitted the existing setting is not changed frame size Optional This parameter specifies the FC frame size If omitted the exis...

Page 198: ...he existing setting is not changed This parameter can be specified only when the RA mode or CA RA auto mode is used enable An REC in synchronous transfer mode is permitted for the target CA port disable An REC in synchronous transfer mode is suppressed for the target CA port rec transfer stack Optional This parameter specifies the asynchronous stack mode for the copy transfer mode If omitted the e...

Page 199: ...9ENZ0 199 Example s The following example sets up the parameters to control FC interface port 0 on CM 1 CA 1 Host Affinity Mode is disabled CLI set fc parameters port 110 host affinity disable The following example sets up the parameters to control FC interface port 1 on CM 0 CA 0 The FC port is a fabric connection CLI set fc parameters port 001 connect fabric ...

Page 200: ... Interface Management show fc parameters ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 200 show fc parameters This command displays the parameters of each FC host interface port Syntax Parameter No parameters show fc parameters ...

Page 201: ...ber The hyphen is shown when the host affinity mode is enabled Reset Scope I_T_L I_T_L Range of reset action I_T_L I Initiator T Target L LUN or T_L T Target L LUN Reserve Cancel at Chip Reset Disable Enable It shows whether reservations are canceled or not when a host interface port is reset REC Line No 127 REC line number 0 127 A hyphen is displayed in the field when the port mode is not the RA ...

Page 202: ...on 1Gbit s Frame Size 2048bytes Host Affinity Enable Host Response No Host Response Name Reset Scope I_T_L Reserve Cancel at Chip Reset Enable REC Line No REC Transfer Mode Sync REC Transfer Mode Stack REC Transfer Mode Consistency REC Transfer Mode Through Port CM 1 CA 0 Port 0 CM 1 CA 0 Port 1 Port Mode RA CA RA Connection FC AL FC AL Loop ID Assign Manual 0x01 Manual 0x01 Transfer Rate Auto Neg...

Page 203: ...ytes Host Affinity Enable Disable Host Response No 6 Host Response Name HP06 Reset Scope I_T_L I_T_L Reserve Cancel at Chip Reset Enable Enable REC Line No REC Transfer Mode Sync REC Transfer Mode Stack REC Transfer Mode Consistency REC Transfer Mode Through Port CM 1 CA 0 Port 0 CM 1 CA 0 Port 1 CM 1 CA 0 Port 2 CM 1 CA 0 Port 3 Port Mode CA CA CA CA Connection FC AL FC AL Fabric Fabric Loop ID A...

Page 204: ... page 25 xyz x is the controller module CM number y is the CA number and z is the SAS port number Example 110 CM 1 CA1 SAS port 0 all All SAS interface ports host affinity Optional This parameter specifies Host Affinity Mode If omitted the existing setting is not changed Host affinity is a security mechanism used to restrict access by a given host to only a specific set of LUNs enable Host Affinit...

Page 205: ...est from all servers that are connected to the port regardless of whether the LUN is recognized reserve cancel Optional This parameter specifies whether or not reservations are canceled when a host interface port is reset If omitted the existing setting is not changed enable Reservations are canceled disable Reservations are not canceled The following example disables Host Affinity Mode for SAS in...

Page 206: ...Each host interface port number Host Affinity Disable Enable Host affinity mode of each host interface port Transfer Rate 3Gbit s 3Gbit s SAS Transfer rate Auto Negotiation 1 5Gbit s 3Gbit s 6Gbit s Host Response No 5 6 Host Response Name HP05 HP06 Host response number The hyphen is shown when the host affinity mode is enabled Reset Scope I_T_L I_T_L Range of reset action I_T_L I Initiator T Targe...

Page 207: ...l at Chip Reset Enable Enable Port CM 0 CA 1 Port 0 CM 0 CA 1 Port 1 Host Affinity Disable Disable Transfer Rate 6bit s 6Gbit s Host Response No 7 8 Host Response Name HP07 HP08 Reset Scope T_L T_L Reserve Cancel at Chip Reset Enable Enable Port CM 1 CA 0 Port 0 CM 1 CA 0 Port 1 Host Affinity Disable Disable Transfer Rate 3Gbit s 3Gbit s Host Response No 9 10 Host Response Name HP09 HP10 Reset Sco...

Page 208: ...ion enable disable isns server ip isns_server_ip isns server enable disable isns server port isns_server_port_number chap enable disable chap user chap_user_name header digest enable disable data digest enable disable jumbo frame enable disable rate auto 1gauto 10gauto 1gfull 100mfull cmdsn count unlimited 20 40 80 120 180 vlan id enable disable vlan id value 0 4095 mtu mtu_size bandwidth bandwidt...

Page 209: ...ble characters are the ones that is shown in 1 2 2 Keywords and Parameters page 19 except for a comma Specify consecutive double quotations alias name for this parameter to remove the alias name This name is not used for control purposes It is only handled as a comment corresponding to the iSCSI name host response number or host response name Optional This parameter specifies the host response ide...

Page 210: ...ver address using IPv4 standard notation a base 256 d d d d string If omitted the existing setting is not changed Example gateway 10 1 0 250 ipv6 flag Optional This parameter specifies whether to use an IPv6 address disable cannot be specified for this parameter if disable is specified for the ipv4 flag parameter enable An IPv6 address is used disable An IPv6 address is not used link local ip Opti...

Page 211: ...t be possible under a high I O load when 0 or 1 is specified Even if 8 or more is specified for the value the operation is performed the same as when 7 is specified congestion control option Optional This parameter specifies whether to use the TCP congestion control option enable The TCP congestion control option enabled disable The TCP congestion control option disabled isns server ip Optional Th...

Page 212: ... currently registered CHAP user name specify consecutive double quotations chap user without any spaces header digest Optional This parameter specifies whether or not the PDU header s CRC32C checksum is validated The initial value is set to disabled Specify disable for the header digest parameter to disable the Digest function When enable is specified for the header digest parameter data transfer ...

Page 213: ...s that are simultaneously acceptable from a host The initial value is set to unlimited This parameter cannot be specified when the port is set to the RA mode Use this parameter only when instructed by our service engineer Standard and Monitor authority users cannot be used unlimited The number of commands is not limited 20 Limited to a maximum of 20 commands 40 Limited to a maximum of 40 commands ...

Page 214: ...nly applicable if CHAP authentication is used If omitted this setting is not changed Up to 255 alphanumerical characters and symbols can be used When this parameter is specified a prompt that requires entering the CHAP user pass word appears To delete a currently registered CHAP user name specify consecutive double quotations chap user without any spaces This parameter is used for the CA setting o...

Page 215: ...transfer mode If omitted the existing setting is not changed This parameter can be specified only when the RA mode or CA RA auto mode is used enable An REC in asynchronous consistency mode is permitted for the target CA port disable An REC in asynchronous consistency mode is suppressed for the target CA port rec transfer through Optional This parameter specifies the asynchronous through mode for t...

Page 216: ...he gateway IP address to connect to iSCSI interface port 1 on CM 0 CA 0 CLI set iscsi parameters port 001 connect ip auto ipv6 gateway auto Connect Address List 0 Cancel 1 2001 1 2 3 4 5 6 7 2 2002 1 2 3 4 5 6 7 3 2003 1 2 3 4 5 6 7 4 2004 1 2 3 4 5 6 7 5 2005 1 2 3 4 5 6 7 Please specify the number of an address to set up from a Connect Address List Input the number 0 1 5 2 IPv6 Gateway Address L...

Page 217: ...face Management show iscsi parameters ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 217 show iscsi parameters This command displays the parameters of each iSCSI host interface port Syntax Parameter No parameters show iscsi parameters ...

Page 218: ...s not accepted Transfer Rate 1Gbit s The above information shows the transfer speed Auto Negotiation 100Mbit s 1Gbit s 10Gbit s Link Status 1Gbit s Link Up The above information shows the actual transfer speed and Link Up or Link Down is displayed for the link status CmdSN Count Unlimited VLAN ID Enable 4090 MTU Limit Band width REC Line No REC line number 0 127 A hyphen is displayed in the field ...

Page 219: ...Enable IP Address 192 168 2 64 Subnet Mask 255 255 255 0 Gateway Address 0 0 0 0 IPv6 Enable Link Local IP Address FE80 290 CCFF FEA4 3A49 Connect IP Address 2001 DB8 8 800 200C 417A IPv6 Gateway Address FE80 2AA FF FE9A 21B8 MAC Address 01 02 03 04 05 06 TCP Port Number 3260 TCP Window Size 0 TCP Congestion Control Option Disable iSNS Server Disable iSNS Server IP Address iSNS Server Port Number ...

Page 220: ...comma Example port 000 110 For details refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the FCoE port number Example 123 indicates CM 1 CA 2 Port 3 all All the FCoE interface ports host affinity Optional This parameter specifies the Host Affinity Mode If omitted the existing setting is not changed The host affinity is the secur...

Page 221: ...ve cancel Optional This parameter specifies whether or not SCSI reservation persistent reservation is canceled when host interface ports are reset If omitted the existing setting is not changed If the RA mode is set for the specified port this parameter cannot be specified enable Reservations are canceled disable Reservations are not canceled fcf vlan id Optional This parameter specifies the FCF V...

Page 222: ...CoE interface port 0 on CM 1 CA 1 Host Affinity Mode is disabled CLI set fcoe parameters port 110 host affinity disable The following example sets up the parameters to control the FCoE interface port 1 on CM 0 CA 0 The FC frame size is 2048 bytes FCF VLAN ID 55 FCF Fabric name 0001000100010001 CLI set fcoe parameters port 001 frame size 2048 fcf vlan id enable fcf vlan id value 55 fcf fabric name ...

Page 223: ...er rate 10Gbit s Frame Size 2048bytes 512bytes 2048bytes 2048bytes FC frame size 512 1024 2048 byte Host Affinity Disable Enable Disable Enable Host affinity mode of each host interface port Host Response No 5 6 7 8 Host Response Name HP05 HP06 HP07 HP08 Host response number The hyphen is shown when the host affinity mode is enabled Reset Scope I_T_L I_T_L I_T_L I_T_L Range of reset action I_T_L I...

Page 224: ... 10Gbit s Frame Size 2048bytes 2048bytes Host Affinity Enable Enable Host Response No Host Response Name Reset Scope I_T_L I_T_L Reserve Cancel at Chip Reset Disable Enable FCF VLAN ID Enable Enable 55 100 FCF Fabric Name Enable Enable 0001000100010001 0002000200020002 Port CM 1 CA 0 Port 0 CM 1 CA 0 Port 1 Port Mode CA CA Transfer Rate 10Gbit s 10Gbit s Frame Size 1024bytes 1024bytes Host Affinit...

Page 225: ...HP05 HP06 HP07 HP08 Reset Scope I_T_L I_T_L I_T_L I_T_L Reserve Cancel at Chip Reset Enable Enable Disable Disable FCF VLAN ID Enable Enable Enable Enable 55 100 1000 2000 FCF Fabric Name Enable Enable Enable Enable 0001000100010001 0002000200020002 0003000300030003 0004000400040004 Port CM 1 CA 0 Port 0 CM 1 CA 0 Port 1 CM 1 CA 0 Port 2 CM 1 CA 0 Port 3 Port Mode CA CA CA CA Transfer Rate 10Gbit ...

Page 226: ...gs and Display 3 5 Host Interface Management ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 226 3 5 2 Host Identifiers Host Alias This section explains commands related to the definition of host identifiers ...

Page 227: ...fies the WWN that corresponds to an HBA The WWN is a 16 byte hexadecimal number Example wwn 40000000abc80e38 name This parameter specifies the host WWN alias For details refer to 1 2 4 Alias Name Syntax page 20 host response number or host response name Optional This parameter specifies the host response identifier Two or more parameters cannot be specified at the same time For details refer to 1 ...

Page 228: ...0000e0e000 The registered host alias is added to host group HG1 CLI create host wwn name wwn e000000000e0e000 name HBA1 host group name HG1 The following example registers host alias HBA1 The WWN is e000000000e0e000 and host response 1 is assigned The registered host alias is added to host group HG2 which is created in host response 1 CLI create host wwn name wwn e000000000e0e000 name HBA1 host re...

Page 229: ...can be specified at the same time If omitted the existing setting is not changed Example wwn 40000000abc78856 name Optional This parameter specifies the host WWN alias Only one parameter can be specified at the same time For details refer to 1 2 4 Alias Name Syntax page 20 If omitted the existing setting is not changed host response number or host response name Optional This parameter specifies th...

Page 230: ...te host wwn name host number host_numbers host name host_names host number or host name This parameter specifies the FC or FCoE host identifiers to be deleted One or more parameters can be specified at the same time For details refer to 1 2 10 Host Syntax page 23 The following example deletes the FC hosts with consecutively numbered identifiers 1 3 CLI delete host wwn name host number 1 3 The foll...

Page 231: ...No parameters Output Example s show host wwn names Host WWN Host Response No Name No Name 1 HBA1 aabbccddeeff0011 1 HP01 A B C D E A Host number B Host WWN nickname C World Wide Name D Assigned the host response number E Assigned the host response name The following example displays a list of all the existing host identifiers CLI show host wwn names Host WWN Host Response No Name No Name 1 HBA1 aa...

Page 232: ...ith a comma If omitted all the FC and FCoE interface ports are selected Example port 000 100 For details refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the port number Example 110 FC port 0 of CA 1 on CM 1 all All the FC FCoE interface ports default all fc All the FC interface ports all fcoe All the FCoE interface ports 01234...

Page 233: ...SAS address which is a 16 character hexadecimal number that corresponds to a HBA Example address 500605b000b5f344 name This parameter specifies the SAS address alias For details refer to 1 2 4 Alias Name Syntax page 20 host response number or host response name Optional This parameter specifies a host response identifier Only one identifier can be specified at any given time For details refer to 1...

Page 234: ...ress 500605b000b5f344 The registered host alias is added to host group HG1 CLI create host sas address address 500605b000b5f344 name HBA1 host group name HG1 The following example registers the alias HBA1 for the HBA with SAS address 500605b000b5f344 The registered host alias is added to host group HG2 which is created in host response 1 CLI create host sas address address 500605b000b5f344 name HB...

Page 235: ...dress which is a 16 character hexadecimal number that corresponds to a HBA Only one SAS address can be specified at any given time If omitted the existing setting is not changed Example address 500605b000b5f344 name Optional This parameter specifies the new SAS address alias Only one name can be specified at the same time For details refer to 1 2 4 Alias Name Syntax page 20 If omitted the existing...

Page 236: ... Interface Management set host sas address ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 236 The following example changes the host named HBA1 assigning it the new alias HBA123 CLI set host sas address host name HBA1 name HBA123 ...

Page 237: ...t sas address host number host_numbers host name host_names host number or host name This parameter specifies which SAS host identifiers are to be deleted One or more identifiers can be specified at the same time For details refer to 1 2 10 Host Syntax page 23 The following example deletes the SAS hosts with consecutively numbered identifiers 1 3 CLI delete host sas address host number 1 3 The fol...

Page 238: ...ameters Output Example s show host sas addresses Host SAS Address Host Response No Name No Name 1 HBA1 500605b000b5f344 1 HP001 A B C D E A Host number B Host nickname C SAS address D Assigned the host response number E Assigned the host response name The following example displays a list of all registered SAS host identifiers CLI show host sas addresses Host SAS Address Host Response No Name No N...

Page 239: ...ses are to be listed If this parameter is omitted the hosts discovered for all SAS host interface ports are displayed Example port 000 100 For details refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the SAS port number Example 123 indicates CM 1 CA 2 SAS Port 3 all All the SAS interface ports default 500605b000b5f144 A A The d...

Page 240: ...n be used Syntax Parameter create host iscsi name iscsi name iscsi_name alias name alias_name ip version ipv4 ipv6 ip ip_address name name chap user chap_user host response number host_response_number host response name host_response_name cmdsn count unlimited 20 40 80 120 180 host group number host_group_number host group name host_group_name new host group name new_host_group_name iscsi name Thi...

Page 241: ...CHAP user name Up to 255 alphanumerical characters and symbols can be used If this parameter is specified then the command displays a CHAP user password prompt host response number or host response name Optional This parameter specifies a host response identifier Only one identifier can be specified at any given time For details refer to 1 2 12 Host Response Syntax page 24 If omitted the existing ...

Page 242: ...resses are allowed by omitting the ip parameter CLI create host iscsi name iscsi name iqn 1991 05 com microsoft ip version ipv4 name HBA1 In addition to the above example IP addresses with the same iSCSI name can be specified as a different alias CLI create host iscsi name iscsi name iqn 1991 05 com microsoft ip version ipv4 name HBA1 CLI create host iscsi name iscsi name iqn 1991 05 com microsoft...

Page 243: ...ter specifies the iSCSI name that corresponds to an HBA Between 4 and 223 alphanumerical characters including hyphens dots and colons can be used If omitted the existing setting is not changed Only one name can be specified at the same time alias name Optional This parameter specifies an alias to the iSCSI name that corresponds to the iscsi name parameter A maximum of 31 alphanumeric characters ca...

Page 244: ...yntax page 20 If omitted the existing setting is not changed Only one name can be specified at the same time chap user Optional When using CHAP authentication this parameter is used to specify a CHAP user name Up to 255 alphanumerical characters and some symbols can be used If this parameter is specified then the command displays a CHAP user password prompt To delete an existing CHAP user name spe...

Page 245: ...host response definition of all the hosts with consecutively numbered identifiers 1 10 at the same time CLI set host iscsi name host number 1 10 host response number 5 The following example changes the host named HBA21 The new alias name is HBA22 and the number of commands that can be accepted at the same time is 80 CLI set host iscsi name host name HBA21 name HBA22 cmdsn count 80 The following ex...

Page 246: ...host iscsi name host number host_numbers host name host_names host number or host name This parameter specifies the iSCSI host identifiers to be deleted One or more identifiers can be specified at the same time For details refer to 1 2 10 Host Syntax page 23 The following example deletes the iSCSI hosts with consecutively numbered identifiers 1 3 CLI delete host iscsi name host number 1 3 The foll...

Page 247: ... the iSCSI host identifier parameter is omitted then an iSCSI host summary list for all the iSCSI host identifiers is displayed Host Host Response IP Address iSCSI Name CmdSN Count No Name No Name 1 HBA ISCSI 001 1 HP01 192 168 1 1 iqn 1991 05 com microsoft 80 A B C D E F G A Host number B Host nickname C Assigned the host response number D Assigned the host response name E IP address which corres...

Page 248: ...s iSCSI Name CmdSN Count No Name No Name 1 HBA ISCSI 001 1 HP01 192 168 1 1 iqn 1991 05 com microsoft 20 2 HBA ISCSI 002 1 HP01 2001 DB8 8 800 200C 417A iqn 1993 05 com microsoft 120 3 HBA ISCSI 003 1 HP01 IPv6 iqn 1993 05 com microsoft Unlimited The following example displays the iSCSI host details of the host named HBA1 CLI show host iscsi names host name HBA1 Host No 1 Host Name HBA1 iSCSI Name...

Page 249: ... Server 2008 R2 Windows Server 2008 Windows Server 2003 Solaris 10 Host information cannot be displayed if the host is running Solaris 11 discover host iscsi names port xyz all port Optional This parameter specifies the iSCSI interface port s whose discovered host iSCSI names are to be listed One or more host interface ports can be specified at the same time If this parameter is omitted the hosts ...

Page 250: ...ple displays a list of the iSCSI hosts that are discovered for the iSCSI interface ports 0 and 1 on CM 0 CA 0 CLI discover host iscsi names port 000 001 CM 0 CA 0 Port 0 Alias iSCSI Name IP Address IQN DXL1 iqn 1991 05 com microsoft 2001 123 1234 2309 0001 CM 0 CA 0 Port 1 Alias iSCSI Name IP Address IQN DXL1 iqn 1991 05 com microsoft 10 17 31 234 IQN DXL2 iqn 1993 05 com microsoft 2001 123 1234 2...

Page 251: ...Z0 251 3 5 3 Affinity Groups This section explains the commands related to affinity groups An affinity group is used to associate volumes with LUNs as seen from the host It is only valid when Host Affinity Mode is enabled In GUI LUN group number and LUN group name is respectively displayed instead of affinity group number and affinity group name ...

Page 252: ...roup Only one name can be specified at the same time For details refer to 1 2 4 Alias Name Syntax page 20 volume number or volume name This parameter specifies the volume identifiers to associate volumes with host LUNs One or more parameters can be specified at the same time For details refer to 1 2 9 Volume Syntax page 22 If two or more LUNs are specified these parameters must also be specified i...

Page 253: ...ate affinity group ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 253 The following example creates the affinity group named AG001 It will associate consecutive volumes 0 10 with LUNs 0 10 CLI create affinity group name AG001 volume number 0 10 lun 0 10 ...

Page 254: ...finition to the specified affinity group and is paired with the lun parameter One or more parameters can be specified at the same time If omitted the existing setting is not changed For details refer to 1 2 9 Volume Syntax page 22 If two or more LUNs are specified these parameters must also be specified in the same order as the associated volumes Any already assigned definitions cannot be specifie...

Page 255: ...AGP002 In the following example the first command creates an affinity group that is named AGP001 This affinity group will contain a definition of the association of consecutive volumes 0 10 and consecutive LUNs 0 10 The second command will add other definitions to the affinity group existing definitions will not change Consecutive volumes 101 105 will be associated with LUNs 11 15 CLI create affin...

Page 256: ...name name This parameter specifies the affinity group name of the target affinity group Only one name can be specified at the same time source ag number or source ag name This parameter specifies the affinity group identifier which is the source of the copy Only one affinity group can be specified at the same time For details refer to 1 2 11 Affinity Group Syntax page 24 The following example copi...

Page 257: ...l This parameter specifies the LUNs that will be removed from the affinity group definitions Two or more parameters can be specified by separating them with a comma a hyphen or both If omitted the specified affinity groups are deleted Example lun 1 2 lun 1 3 lun 1 3 5 The following example only deletes affinity group 1 CLI delete affinity group ag number 1 The following example deletes affinity gr...

Page 258: ...same volume is defined for multiple affinity groups is a status flag show affinity groups ag number ag_numbers ag name ag_names ag number or ag name Optional This parameter specifies the affinity group identifiers that will be displayed in detail One or more parameters can be specified If omitted a summary of all the existing affinity groups will be displayed When the parameter is specified the de...

Page 259: ...e size H It shows whether or not the same volume identifier is defined between affinity groups If the same definitions exist Yes is displayed in target volumes Otherwise No is displayed The following example displays a summary of all the existing affinity groups The multi group volume information flag is also displayed CLI show affinity groups Affinity Group Multi Group No Name Volumes 4 AG004 Yes...

Page 260: ...09ENZ0 260 3 5 4 LUN Groups This section explains the commands used for LUN group control A LUN group is a definition of the association between LUNs as seen from the host and volumes LUN groups are only valid when the Host Affinity Mode is enabled The definition of LUN groups is the same as affinity groups except that the name is different ...

Page 261: ...For details refer to 1 2 4 Alias Name Syntax page 20 volume number or volume name This parameter specifies the volume identifiers to associate volumes with host LUNs One or more parameters can be specified at the same time For details refer to 1 2 9 Volume Syntax page 22 If two or more LUNs are specified these parameters must be specified in the same order Example volume number 10 12 lun 1 3 The v...

Page 262: ...ment create lun group ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 262 The following example creates the LUN group named AG001 It will associate consecutive volumes 0 10 with LUNs 0 10 CLI create lun group name AG001 volume number 0 10 lun 0 10 ...

Page 263: ... specified LUN group and is paired with the lun parameter One or more parameters can be specified at the same time If omitted the existing setting is not changed For details refer to 1 2 9 Volume Syntax page 22 If two or more LUNs are specified these parameters must also be specified in the same order as the associated volumes Any already assigned definitions cannot be specified Example volume num...

Page 264: ...rst command creates the LUN group named AGP001 This LUN group will contain a definition of the association of consecutive volumes 0 10 and consecutive LUNs 0 10 The second command adds other definitions to the LUN group Consecutive volumes 101 105 will be associated with LUNs 11 15 Existing definitions are retained after the second command is executed Only the definitions specified in the second c...

Page 265: ...e_lg_name name This parameter specifies the LUN group name of the target LUN group Only one name can be specified at the same time source lg number or source lg name This parameter specifies the LUN group identifier which is the source of the copy Only one LUN group can be specified at the same time For details refer to 1 2 11 Affinity Group Syntax page 24 The following example copies the definiti...

Page 266: ...n Optional This parameter specifies the LUNs that will be removed from the LUN group definitions Two or more parameters can be specified by separating them with a comma a hyphen or both If omitted the specified LUN groups are deleted Example lun 1 2 lun 1 3 lun 1 3 5 The following example only deletes LUN group 1 CLI delete lun group lg number 1 The following example deletes LUN groups 1 and 2 CLI...

Page 267: ... not the same volume is defined for multiple LUN groups is a status flag show lun groups lg number lg_numbers lg name lg_names lg number or lg name Optional This parameter specifies the LUN group identifiers that will be displayed in detail One or more parameters can be specified If omitted a summary of all the existing LUN groups will be displayed When the parameter is omitted a summary of all th...

Page 268: ...ume size H It shows whether or not the same volume identifier is defined between LUN groups If the same definitions exist Yes is displayed in target volumes Otherwise No is displayed The following example displays a summary of all the existing LUN groups In addition the multi group volume information flag is displayed CLI show lun groups LUN Group Multi Group No Name Volumes 4 AG004 Yes 5 AG005 No...

Page 269: ...tails refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the host port number Example 123 host port 3 of CA 2 on CM 1 host number or host name This parameter specifies the identifier of the related host Multiple parameters can be set at the same time For details on the contents that can be entered refer to 1 2 10 Host Syntax page...

Page 270: ...he host interface ports are selected Example port 000 100 For details refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the host port number Example 123 host port 3 of CA 2 on CM 1 all All of the host interface ports default Port Host Path State No Name CM 0 CA 0 Port 0 0 FC 0 Online CM 0 CA 0 Port 0 1 FC 1 Online CM 0 CA 0 Port...

Page 271: ...I User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 271 The following example displays the status of all of the paths associated with host interface port CM 1 CA 0 Port 0 CLI show host path state port 100 Port Host Path State No Name CM 1 CA 0 Port 0 0 FC 0 Online CM 1 CA 0 Port 0 1 FC 1 Offline ...

Page 272: ...ITSU LIMITED P2X0 1030 09ENZ0 272 3 5 5 Mapping When Affinity Groups are Used This section explains the commands related to the mapping function that are available when Host Affinity Mode is enabled or LUN groups port groups or host groups are used An affinity group must be defined and created before commands are used ...

Page 273: ...nterface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the host port number Example 123 indicates CM 1 CA 2 Host port 3 ag number or ag name This parameter specifies the affinity group identifiers that will be associated One or more parameters can be specified at the same time For details refer to 1 2 11 Affinity Group Syntax page 24 If two or more affini...

Page 274: ...d Only one parameter can be specified at the same time For details refer to 1 2 11 Affinity Group Syntax page 24 lg number or lg name When this parameter is used with the port group number or the port group name parameter Optional This parameter specifies the LUN group identifiers that will be associated Only one parameter can be specified at the same time For details refer to 1 2 11 Affinity Grou...

Page 275: ... on CM 1 and CA 0 Port 1 on CM 1 the affinity group named AGP001 and the host named HBA001 CLI set host affinity port 100 101 ag name AGP001 host name HBA001 identical with the following CLI set host affinity port 100 ag name AGP001 host name HBA001 CLI set host affinity port 101 ag name AGP001 host name HBA001 The following example sets the relationship between the port group named PG001 the affi...

Page 276: ...er Example 123 indicates CM 1 CA 2 Host port 3 destination port This parameter specifies the host interface ports of the copy destination Two or more parameters can be specified by separating them with a comma Example destination port 000 100 For details refer to 1 2 14 Host Interface Port Syntax page 25 If all is selected all of the host interface ports will be changed xyz x is the controller mod...

Page 277: ...e mapping definition for the specified host identifiers is released xyz x is the controller module CM number y is the CA number and z is the host port number Example 123 indicates CM 1 CA 2 Host port 3 all All the host interface ports The settings for all of the ports are released When this parameter is specified the host number or host name parameter cannot be specified host number or host name O...

Page 278: ...up number No No No No No host group name No No No No No The following example releases all of the host affinity settings that have been made on host interface CA 0 Port 0 on CM 1 CLI release host affinity port 100 The following example only releases the host affinity settings of the host named H1 on CA 0 Port 1 on CM 0 CLI release host affinity port 001 host name H1 The following example releases ...

Page 279: ...ifies the host interface ports to be narrowed down Two or more parameters can be specified by separating them with a comma If omitted all the host interface ports are selected Example port 000 100 For details refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the host port number Example 123 indicates CM 1 CA 2 Host port 3 all Al...

Page 280: ...HBA1 4 AG004 No A B C D E A Host number B Host name C Affinity group number or LUN group number D Affinity group name or LUN group name E It shows whether or not the same volume identifier is defined between affinity groups If the same definitions exist Yes is displayed in target affinity groups Otherwise No is displayed When a host affinity is set for the port group Host Affinity Mode is enabled ...

Page 281: ...all of the existing mappings CLI show host affinity Port Group Host Group Affinity LUN Group Multi Group No Name No Name No Name Volumes 1 pg1 0 hg 0 ag1 No Connection List Port Host No Name CM 0 CA 0 Port 0 CM 0 CA 0 Port 1 0 A CM 0 CA 0 Port 1 1 B Port Group Host Group Affinity LUN Group Multi Group No Name No Name No Name Volumes 2 pg01 1 FCoE 1 ag2 No Connection List Port Host No Name CM 0 CA ...

Page 282: ...es 1 HBA1 4 AG004 No CM 0 CA 0 Port 1 Host Affinity Mode Enable Host Affinity LUN Group Multi Group No Name No Name Volumes 1 HBA1 4 AG004 No The following example only displays the mapping that is set to the host named HBA5 CLI show host affinity host name HBA5 CM 1 CA 1 Port 1 Host Affinity Mode Enable Host Affinity LUN Group Multi Group No Name No Name Volumes 5 HBA5 6 AG006 No The following is...

Page 283: ...SU LIMITED P2X0 1030 09ENZ0 283 3 5 6 Mapping When Host Affinity Mode is Not Used This section explains the commands for mapping when Host Affinity Mode is disabled When Host Affinity Mode is not enabled mapping is the definition of the associated volumes with the host LUNs that applies for all the connected host servers ...

Page 284: ...ing them with a comma Example port 000 100 For details refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the host port number Example 123 indicates CM 1 CA 2 Host port 3 volume number or volume name This parameter specifies volumes identifiers to be associated One or more parameters can be specified at the same time For details ...

Page 285: ...ng port 010 volume name VOL001 lun 1 The following example sets the relationship between host interface port 0 and 1 on CM 0 CA 0 the volume named VOL002 and LUN 2 CLI set mapping port 000 001 volume name VOL002 lun 2 identical with the following CLI set mapping port 000 volume name VOL002 lun 2 CLI set mapping port 001 volume name VOL002 lun 2 The following example sets the relationship between h...

Page 286: ...is the host port number Example 123 indicates CM 1 CA 2 Host port 3 destination port This parameter specifies the host interface ports to be released Two or more parameters can be specified by separating them with a comma Example destination port 000 100 For details refer to 1 2 14 Host Interface Port Syntax page 25 If all is selected all of the host interface ports will be changed xyz x is the co...

Page 287: ...meter then only the mapping definition of the host interface port and the specified LUN is released xyz x is the controller module CM number y is the CA number and z is the host port number Example 123 indicates CM 1 CA 2 Host Port 3 all All the host interface ports lun Optional This parameter specifies which specific LUN mappings will be released from the mapping associations Two or more paramete...

Page 288: ...tings and Display 3 5 Host Interface Management release mapping ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 288 The following example releases all the registered mappings CLI release mapping port all ...

Page 289: ...separating them with a comma If omitted all the host interface ports are displayed Example port 000 100 For details refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the host port number Example 123 indicates CM 1 CA 2 Host port 3 all All the host interface ports default volume number or volume name Optional This parameter speci...

Page 290: ...Name 3 1 VOL001 Available 32 4 2 VOL002 Available 32 5 3 VOL003 Available 32 CM 1 CA 0 Port 1 Host Affinity Mode Enable The following example only displays the mappings associated with the volume named VOL001 CLI show mapping volume name VOL001 CM 0 CA 0 Port 0 Host Affinity Mode Disable LUN Volume Status Size MB No Name 1 1 VOL001 Available 32 CM 1 CA 0 Port 0 Host Affinity Mode Disable LUN Volum...

Page 291: ...ation Settings and Display 3 5 Host Interface Management ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 291 3 5 7 Host Response This section explains commands related to set up the host response ...

Page 292: ...0 disable vpd type1 type1 3 type3 conflict enable disable name name timeout timeout version 5 4 3 host specific mode normal aix hp ux linux bs2000 symmetric active passive lun change enable disable lun expand enable disable vendor unique sense enable disable iscsi disc rsp all port tpgs enable disable tpg referrals enable disable iscsi rsv range port system host response number or host response na...

Page 293: ...ponded disable The value that is specified in the ETERNUS DX Disk storage system is responded default vpd Optional This parameter specifies the Vital Product Data VPD information type to respond to the host VPD information includes the device information Vender ID Product ID for each model volume number etc for the volume Type1 and Type3 indicate the data format If omitted this parameter is left u...

Page 294: ...he operation environment for a Linux server bs2000 BS2000 Mode symmetric Optional This parameter specifies the method that is used to access a Logical Unit If omitted the existing setting is not changed active ACTIVE ACTIVE default value for the ETERNUS DX8700 S2 passive ACTIVE ACTIVE PREFERRED PATH default value for the ETERNUS DX80 S2 DX90 S2 ETERNUS DX410 S2 DX440 S2 and ETERNUS DX8100 S2 lun c...

Page 295: ...errals Optional This parameter specifies whether to enable the TPG Referrals When enable is set for this parameter TPG Referrals are only performed when TPGS is enabled and Asymmetric Symmetric Logical Unit Access is set to ACTIVE ACTIVE PRFERRED_PATH Set enable for this parameter only for connection environments in which the ETERNUS Mul tipath Driver that is being used supports TPG Referrals enab...

Page 296: ...ers to be deleted Host response 0 is the system default and it cannot be deleted One or more parameters can be specified at the same time For details refer to 1 2 12 Host Response Syntax page 24 Host responses with the following combination of numbers and names cannot be deleted No 0 Default No 250 Solaris MPxIO No 251 HP UX No 252 AIX EMPD No 253 AIX VxVM No 254 AIX Single Path No 255 VS850 SVC T...

Page 297: ...a summary list is displayed For details refer to 1 2 12 Host Response Syntax page 24 The following details are displayed when a host response identifier is specified Host Response No 5 Host Response Name am0005 Byte 0 of Inquiry Response Not conversion Default Inquiry VPD ID Type Type1 Type3 Default Inquiry Standard Data Version Version 5 Default Command Timeout Interval 25 Default Load Balance Re...

Page 298: ... Command Timeout Interval 25 Default Load Balance Response Unit Attention Default Reservation Conflict Response for Test Unit Ready Normal Default Change Volume Mapping Not report Default Volume Capacity Expansion Not report Default Vendor Unique Sense Code Not report Default Host Specific Mode Normal Default Asymmetric Symmetric Logical Unit Access ACTIVE ACTIVE PREFERRED_PATH iSCSI Discovery Rep...

Page 299: ... Settings and Display 3 5 Host Interface Management ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 299 3 5 8 Host Sense Conversion This section explains the commands related to host sense conversion ...

Page 300: ...rt to the default host sense value Default linux Linux host when Linux GRMPD is not in use windows Windows host when GR ETERNUS MPD and its device driver are not in use custom Custom setting The following sense parameters can be specified only when this setting is selected original sk Optional This parameter specifies the sense key that corresponds to the sense of the conversion source This parame...

Page 301: ...rsion destination This parameter can only be specified when preset custom is selected This parameter must be specified by using either a hexadecimal number or the wildcard converted ascq Optional This parameter specifies the sub sense code which is an additional sense code qualifier that corresponds to the sense of the conversion destination This parameter can only be specified when preset custom ...

Page 302: ...the host sense to be deleted belongs The range is 1 to 127 One or more parameters can be specified at the same time For details refer to 1 2 12 Host Response Syntax page 24 sense number This parameter specifies the host sense number that is to be deleted The host sense number is automatically registered in the system when the host sense conversion information is created Between 1 to 8 can be speci...

Page 303: ...esponse identifiers can be specified at the same time For details refer to 1 2 12 Host Response Syntax page 24 Host Response Sense Original Converted No Name No Sense Code Sense Code 6 fj0006 1 04 06 Linux A B C D E F G H I J A Host response number B Host response name C Host sense number D Original sense key E Original sense code Additional sense code F Original sub sense code Additional sense co...

Page 304: ... 5 Host Interface Management ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 304 3 5 9 Reset Group for Host Interface Port This section explains the commands related to defining the reset groups for each host interface port ...

Page 305: ... s set ca reset group group xyz group This parameter sets up a combination of host interface ports that will be reset as a group Two or more host interface ports can be specified by separating them with a comma Example group 000 100 For details refer to 1 2 14 Host Interface Port Syntax page 25 If a host interface port in the specified group is already set for another group this port is released f...

Page 306: ...how ca reset group The following example displays a system that has 4 host interface ports Port Reset Group 000 001 002 003 Reset Group 100 101 102 103 A A A A A Host interface port 0 in the reset group The following example shows each reset group configured with four host interface ports CLI show ca reset group Port Reset Group 000 001 002 003 Reset Group 010 011 012 013 Reset Group 100 101 102 1...

Page 307: ...s and Display 3 5 Host Interface Management ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 307 3 5 10 Ping Command for iSCSI hosts This section explains the ping related commands used in an iSCSI environment ...

Page 308: ...s the controller module CM number y is the CA number and z is the iSCSI port number Example 123 indicates CM 1 CA 2 Host port 3 ip This parameter specifies the IP address of the target iSCSI host using IPv4 standard notation a base 256 d d d d string or IPv6 format The types of IPv6 addresses that can be specified are global addresses including 6to4 addresses link local addresses and unique local ...

Page 309: ...P2X0 1030 09ENZ0 309 The following example sends three pings from port 0 on CM 1 CA 0 to iSCSI host 2001 0db8 0020 0003 1000 0100 0020 0003 In this case a Success string is displayed This result indicates that a normal response was received for all of the pings CLI test iscsi ping port 100 ip 2001 0db8 0020 0003 1000 0100 0020 0003 count 3 Success ...

Page 310: ...y 3 5 Host Interface Management ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 310 3 5 11 Port Groups This section explains the commands related to port groups The port group is used to control multiple ports as a group ...

Page 311: ... host affinity disabled cannot belong to a port group Up to eight ports can be set for a single port group create port group name name port xyz name This parameter specifies a name of the port group Only one name can be specified at the same time For details refer to 1 2 4 Alias Name Syntax page 20 port This parameter specifies the host interface port Two or more parameters can be specified by sep...

Page 312: ...he port group might not have any logical paths In this case the mapping setting between port groups must be also deleted Up to eight ports can be set for a single port group set port group port group number port_group_number port group name port_group_name name port_group_name add port ports release port ports port group number or port group name This parameter specifies the port group identifier ...

Page 313: ...rt group name PG001 name NEW_PG002 The first command will create the port group named PG0001 This port group will contain FC interface port 1 on CM 0 CA 0 and FC interface port 1 on CM 0 CA 1 The second command will add other definitions to the port group named PG0001 FC interface port 1 on CM 1 CA 0 and FC interface port 1 on CM 1 CA 1 are added to the port group CLI create port group port group ...

Page 314: ...deleted delete port group port group number port_group_numbers port group name port_group_names port group number or port group name This parameter specifies the port group identifiers to be deleted One or more parameters can be specified at the same time For details refer to 1 2 15 Port Group Syntax page 26 The following example only deletes port group 1 CLI delete port group port group number 1 ...

Page 315: ...p name Optional This parameter specifies the port group identifiers that will be displayed in detail One or more parameters can be specified If omitted a summary of all the existing port groups will be displayed For details refer to 1 2 15 Port Group Syntax page 26 all Optional When this parameter is specified the details of all the existing port groups are displayed When the parameter is omitted ...

Page 316: ... CA 0 Port 1 A Port group number B Port group name C CA type D Port number The following example displays a summary of all the existing port groups CLI show port groups Port Group CA Type No Name 0 pg FC 1 pg1 FC The following example displays details of port group 0 CLI show port groups port group number 0 Port Group CA Type No Name 0 pg FC Port List CM 0 CA 0 Port 1 The following example display...

Page 317: ...y 3 5 Host Interface Management ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 317 3 5 12 Host Groups This section explains the commands related to host groups The host group is used to control multiple hosts as a group ...

Page 318: ...st response settings for host group C are also changed to host group B and so forth create host group name host_group_name host type fc iscsi sas host response number host_response_numbes host response name host_response_name host number host_numbers host name host_names name This parameter specifies a name of the port group Only one name can be specified at the same time For details refer to 1 2 ...

Page 319: ...TED P2X0 1030 09ENZ0 319 Example s The following example creates the host group named HG001 FC is specified for the host type parameter 10 is specified for the host response number parameter and 1 and numbers 3 to 5 are specified for the host number parameter CLI create host group name HG001 host type fc host response number 10 host number 1 3 5 ...

Page 320: ... settings for host group B are changed to the host group A settings In addition if the same hosts are registered in host group B and another existing host group C the host response settings for host group C are also changed to host group B and so forth set host group host group number host_group_number host group name host_group_name host response number host_response_number host response name hos...

Page 321: ...er 1 2 For details refer to 1 2 10 Host Syntax page 23 The following example changes the host group named HG001 The new name is NEW_HG002 The host response number is changed to 2 CLI set host group host group name HG001 host response number 2 name NEW_HG002 The first command will create the host group named HG0001 Host numbers 1 and 2 belong to this host group The second command will add other def...

Page 322: ...umbers host group name host_group_names keep host mode enable disable host group number or host group name This parameter specifies the host group identifiers to be deleted One or more parameters can be specified at the same time For details refer to 1 2 16 Host Group Syntax page 26 keep host mode This parameter specifies whether the hosts are deleted If omitted this parameter is handled as though...

Page 323: ...ary of all the existing host groups will be displayed For details refer to 1 2 16 Host Group Syntax page 26 all Optional When this parameter is specified the details of all the existing host groups are displayed host number or host name Optional This parameter specifies the host that is included in the host group that is to be displayed in detail One or more parameters can be specified For details...

Page 324: ...existing host groups CLI show host groups Host Group Host Response Host Type No Name No Name 0 hg 250 Solaris MPxIO FC FCoE 1 FCoE 250 Solaris MPxIO FC FCoE 2 iscsi 254 AIX Single Path iSCSI The following example displays details of host group 0 CLI show host groups host group number 0 Host Group Host Response Host Type No Name No Name 0 hg 250 Solaris MPxIO FC FCoE Host List Host WWN No Name 0 A ...

Page 325: ...s ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 325 The following example displays details of host 0 CLI show host groups host number 0 Host Group Host Response Host Type No Name No Name 0 hg 250 Solaris MPxIO FC FCoE Host List Host WWN No Name 0 A aaaaaaaaaaaaaaaa ...

Page 326: ...figuration Settings and Display 3 5 Host Interface Management ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 326 3 5 13 Host LU QoS This section explains the commands related to Host LU QoS ...

Page 327: ...tax Parameter Example s set host lu qos mode mode enable disable mode This command specifies whether to enable or disable the Host LU QoS function enable This parameter enables the Host LU QoS function disable This parameter disables the Host LU QoS function The following example enables the Host LU QoS function CLI set host lu qos mode mode enable The following example disables the Host LU QoS fu...

Page 328: ...s mode This command displays the setting status of the Host LU QoS function Syntax Parameter No parameters Output Example s show host lu qos mode Host LU QoS Mode Enable A A Setting status of the Host LU QoS Mode The following example displays the setting status of the Host LU QoS function CLI show host lu qos mode Host LU QoS Mode Disable CLI show host lu qos mode Host LU QoS Mode Enable ...

Page 329: ...0 and 2175 for ETERNUS DX8700 S2 can be specified lun This parameter specifies the Host LUN that is to be set Any value between 0 and 1023 can be specified Two or more Host LUNs can be specified Example lun 1 2 lun 0 10 lun 1 2 9 bandwidth limit This parameter specifies the performance limit value for the Host LUN Any value between 0 unlimited and 15 Max can be specified Two or more values can be ...

Page 330: ...7 500 IOPS 500MB s 5 5 040 IOPS 400MB s 6 3 000 IOPS 300MB s 7 1 020 IOPS 200MB s 8 780 IOPS 100MB s 9 600 IOPS 70MB s 10 420 IOPS 40MB s 11 300 IOPS 25MB s 12 240 IOPS 20MB s 13 180 IOPS 15MB s 14 120 IOPS 10MB s 15 60 IOPS 5MB s The following example sets the LU QoS Group CLI set lu qos group lu qos group 1 lun 2 bandwidth limit 15 CLI set lu qos group lu qos group 1 lun 1 2 bandwidth limit 1 CL...

Page 331: ...s parameter specifies which Host LUNs to display detailed information for When all is specified the information for the LUNs with 0 Unlimited as the Bandwidth Limit is also displayed If omitted the information for the LUNs with 0 Unlimited as the Bandwidth Limit is not displayed When a list of the LU QoS Groups is displayed CLI show lu qos groups LU QoS Group No 0 1 2 A A Registered LU QoS Groups ...

Page 332: ... P2X0 1030 09ENZ0 332 Example s The following example displays a list of the LU QoS Groups CLI show lu qos groups LU QoS Group No 0 1 2 3 The following example displays the detailed information of the LU QoS Group 1 and 2 CLI show lu qos groups lu qos group 1 2 LU QoS Group No 1 LUN Bandwidth Limit 0 4 1 11 LU QoS Group No 2 LUN Bandwidth Limit 2 3 ...

Page 333: ...P2X0 1030 09ENZ0 333 delete lu qos group This command deletes LU QoS Groups Syntax Parameter Example s delete lu qos group lu qos group lu_qos_group_number lu qos group This parameter specifies the LU QoS Group number that is to be deleted Two or more LU QoS Groups can be specified The following example deletes LU QoS Group 1 CLI delete lu qos group 1 ...

Page 334: ..._names bandwidth limit bandwidth limits event number event numbers schedule number schedule numbers port xyz host number host_numbers host name host_names lu qos group lu_qos_group_numbers event number event_numbers schedule number schedule_numbers mode This parameter specifies which QoS settings are changed port qos Port QoS host qos Host QoS lu qos LU QoS port This parameter specifies the host i...

Page 335: ...0 IOPS 90 MB s 240 IOPS 20 MB s 13 480 IOPS 60 MB s 180 IOPS 15 MB s 14 240 IOPS 30 MB s 120 IOPS 10 MB s 15 120 IOPS 15 MB s 60 IOPS 5 MB s host type This parameter specifies the type of host to set Host QoS for The host can be specified by using the host number or host name parameter fc FC FCoE iscsi iSCSI sas SAS host number or host name This parameter specifies which host to set Host QoS or LU...

Page 336: ...t 000 host number 12 lu qos group 1 The following example sets the LU QoS and the default QoS schedule for the LU QoS for a port with the Host Affinity mode disabled CLI set host lu qos mode lu qos port 000 lu qos group 1 The following example restores the initial setting of the LU QoS and sets the default QoS schedule for the LU QoS for a port with the Host Affinity mode enabled CLI set host lu q...

Page 337: ...0 337 The following example sets the QoS schedule for the LU QoS for a port with the Host Affinity mode disabled CLI set host lu qos mode lu qos port 000 lu qos group 1 event number 1 schedule number 5 The following example restores the initial settings of the QoS schedule for the Port QoS CLI set host lu qos mode port qos port 000 event number 2 schedule number ...

Page 338: ... port Example port 000 For details refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the host port number Example 123 indicates CM 1 CA 2 Port 3 all All the host interface ports host type Optional This parameter specifies the type of host to set Host QoS for The host can be specified by using the host number or host name paramet...

Page 339: ...up CM 0 CA 0 Port 0 0 2 Host FC_1 1 2 A B C D E F Event No Port Host Schedule No LU QoS Schedule No Bandwidth Limit Schedule No Bandwidth Limit Group 1 10 5 1 3 15 3 2 20 8 3 5 25 4 3 30 10 5 7 35 5 G H I J K L M A Host interface port B Performance limit value for the host interface port C Host number D Host name E Performance limit value for the host F LU QoS Group number that is set for the LU Q...

Page 340: ...Bandwidth Limit Host Type WWN iSCSI Name SAS Address No Name 1000 1234567890123456 12 FC FCoE iqn 1991 05 com microsoft A B C D E A Host number B Host name C Performance limit value for the host D Host type E WWN for FC FCoE iSCSI name for iSCSI or SAS address for SAS of the host When the Host QoS settings are displayed with the target host specified Host Bandwidth Limit Host Type WWN iSCSI Name S...

Page 341: ...FC_0 0 CM 0 CA 0 Port 0 0 2 Host FC_1 1 2 CM 0 CA 1 Port 0 2 0 Host iSCSI_0 5 2 CM 1 CA 0 Port 0 3 0 Host FC_0 0 3 CM 1 CA 0 Port 0 3 2 Host FC_1 1 3 CM 1 CA 1 Port 0 15 0 Host iSCSI_0 5 2 The following example displays the details of the LU Host LU QoS settings CLI show host lu qos port 000 001 Port Bandwidth Limit Host Bandwidth Limit LU QoS No Name Group CM 0 CA 0 Port 0 0 0 Host FC_0 0 Event N...

Page 342: ...C FCoE AABBCCDDEEFF0011 2 Host SAS_0 4 SAS FFAABBCCDDEE0011 0 Host iSCSI_0 5 iSCSI iqn 1991 05 com microsoft The following example displays the details of the Host QoS settings CLI show host lu qos mode host qos host type iscsi host number 0 Host Bandwidth Limit Host Type WWN iSCSI Name SAS Address No Name 0 Host iSCSI_0 5 iSCSI iqn 1991 05 com microsoft Event No Schedule No Bandwidth Limit 1 2 3 ...

Page 343: ... specified for the ETERNUS DX80 S2 DX90 S2 ETERNUS DX410 S2 DX440 S2 and ETERNUS DX8100 S2 and from 0 to 2047 for the ETERNUS DX8700S2 Example schedule number 1 2 schedule number 0 10 schedule number 1 2 9 event type Optional This parameter specifies the QoS schedule event type every day The QoS schedule is applied to every day A suboperand is not required Example event type every day every week T...

Page 344: ...week This format is specific week MM W STA END The specific month MM 01 12 and the specific week W 1st 2nd 3rd 4th or last are separated by a comma when every month is required specify em instead of 01 12 The start day of the week STA and the end day of the week END are separated by a comma The day of the week must be specified in the following format The end day of the week must be after the star...

Page 345: ...l end at a specific time The format is hhmm hh is the ending hour 00 23 and mm is the ending minute 00 10 20 30 40 or 50 The following example creates an QoS schedule The QoS schedule number is 0 The QoS schedule will apply every day from 06 00 to 18 00 CLI set lu qos schedule schedule number 0 event type every day event from 0600 event to 1800 The following example deletes the QoS schedule CLI se...

Page 346: ...o 12 20 1 Every week Monday Tuesday from 00 00 to 18 30 2 Specific day 1day s from Every month 15 from 00 40 to 18 30 512 Specific day 1day s from December 31 from 00 00 to 23 50 2047 Specific week Every month last week Monday Sunday from 00 00 to 06 00 A B C D E A QoS schedule number B QoS schedule event type C Explanation for the QoS schedule event type D Starting QoS schedule time E Ending QoS ...

Page 347: ...e Host LU QoS performance information is collected Two or more ports can be specified by separating them with a comma Example port 000 100 For more details refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the port number Example 123 indicates CM 1 CA 2 Port 3 all All the ports The following example starts the collection of Host...

Page 348: ...e Host LU QoS performance information is collected Two or more ports can be specified by separating them with a comma Example port 000 100 For more details refer to 1 2 14 Host Interface Port Syntax page 25 xyz x is the controller module CM number y is the CA number and z is the port number Example 123 indicates CM 1 CA 2 Port 3 all All the ports The following example stops the collection of Host ...

Page 349: ...s that are associated with the host for which the performance measurement information is to be displayed The port parameter must be set to use this parameter Multiple hosts cannot be specified For details refer to 1 2 10 Host Syntax page 23 When parameters are omitted Port IOPS Throughput MB s Delay Time ms Ave Min Max Ave Min Max Total Ave CM 0 CA 0 Port 0 100 10 100 2 1 3 20 10 CM 0 CA 0 Port 1 ...

Page 350: ... port I Maximum number of I Os per second for a port J Average transfer amount per second for a port in MB s K Minimum transfer amount per second for a port in MB s L Maximum transfer amount per second for a port in MB s M Accumulated delay time for the start of a command due to the QoS control of a port in milliseconds Overflow is displayed when a long time passes from the start of performance me...

Page 351: ... a port I Maximum number of I Os per second for a port J Average transfer amount per second for a port in MB s K Minimum transfer amount per second for a port in MB s L Maximum transfer amount per second for a port in MB s M Accumulated delay time since the start of a command from the QoS control of a port in milliseconds Overflow is displayed when a long time passes from the start of performance ...

Page 352: ...A Host interface port number B Port type C Host affinity Enable enabled Disable disable D Measurement status ON performance is being measured OFF performance measuring is stopped E Performance measurement start time F Performance measurement stop time G Host number H Host name I Host WWN when the port type is FC or FCoE Host iSCSI name when the port type is iSCSI or Host SAS address when the port ...

Page 353: ...pecified J Host IP address shows the actual IP address of the host that is logged in to the ETERNUS Disk storage system The following example displays the performance measurement information when no parameters are set For CM 1 CA 0 Port 0 Delay Total Time exceeds the limit and Overflow is displayed CLI show host lu qos performance Port IOPS Throughput MB s Delay Time ms Ave Min Max Ave Min Max Tot...

Page 354: ... Port Type FC Host Affinity Enable Performance Monitoring ON Monitoring Start Time 2012 04 11 12 00 00 Monitoring Stop Time 2012 04 11 12 05 00 Host Performance Information Host No 0 Host Name HOST 0 WWN aabbccddeeff0011 IOPS Throughput MB s Delay Time ms Ave Min Max Ave Min Max Total Ave Host Total 111000 110 222000 20 10 30 1000 10 IOPS Throughput MB s Delay Time ms LUN Ave Min Max Ave Min Max T...

Page 355: ...oft IP Address 192 168 43 151 IOPS Throughput MB s Delay Time ms Ave Min Max Ave Min Max Total Ave Host Total 111000 110 222000 20 10 30 1000 10 IOPS Throughput MB s Delay Time ms LUN Ave Min Max Ave Min Max Total Ave 1 20 10 100 2 1 3 20 10 1021 60 11 30 2 1 2 120 10 Host Performance Information Host No 0 Host Name HOST 0 iSCSI Name iqn 1991 05 com microsoft IP Address 192 168 43 152 IOPS Through...

Page 356: ...t This section explains the commands that manage a user account and a password 4 1 1 Role Roles define the user roles and the policies based on the definitions that are assigned to each role Policies are given to users as roles There are default roles that are preset in the ETERNUS DX Disk storage system and user defined roles custom roles The following table shows the roles and their policies Def...

Page 357: ...ith only the default roles Multiple user policies can be assigned to a single custom role For details on creating and setting up a custom role refer to the create role and set role commands Copy Session Management Yes Yes Yes Storage Management Yes Yes User Management Yes Yes Authentication Role Yes Yes Security Setting Yes Yes Maintenance Information Yes Yes Yes Maintenance Operation Yes Software...

Page 358: ... the policies that are assigned to the role Use the numbers that are listed below to specify policies Multiple policies can be specified at the same time Enter a comma or a hyphen between numbers to specify multiple policies Note that spaces are not permitted before or after commas 1 Status Display 2 RAID Group Management 3 Volume Create Modify 4 Volume Delete Format 5 Host Interface Management 6 ...

Page 359: ...s policies to set for the role Use the numbers that are listed below to specify policies Multiple policies can be specified at the same time Enter a comma or a hyphen between numbers to specify multiple policies Note that spaces are not permitted before or after commas If omitted this parameter is not changed 1 Status Display 2 RAID Group Management 3 Volume Create Modify 4 Volume Delete Format 5 ...

Page 360: ...This command deletes a specified user defined role Note that any roles that are already assigned to users cannot be deleted Syntax Parameter Example s delete role name name name This parameter specifies the role name that is to be deleted Only one parameter can be specified at the same time The following example deletes the role named Role2 CLI delete role name Role2 ...

Page 361: ...put Example s show role Role Name type Policies Role1 all 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B C A User defined role name B Role type not supported C Assigned policies The following example displays all the registered user defined roles CLI show role Role Name type Policies Monitor all 1 Admin all 1 2 3 4 5 6 7 10 11 12 13 15 StorageAdmin all 1 2 3 4 5 6 7 AccountAdmin all 11 12 SecurityA...

Page 362: ...ers are required role This parameter specifies the role For details refer to 4 1 1 Role page 356 Total Administrator role Maintainer Maintenance operator SecurityAdmin Security administrator AccountAdmin Account administrator StorageAdmin ETERNUS DX Disk storage system administrator Administrator Total administrator Monitor Monitor Software Software User defined role Role that is created using the...

Page 363: ...ifies the role If omitted the existing setting is not changed Total Administrator role Maintainer Maintenance operator SecurityAdmin Security administrator AccountAdmin Account administrator StorageAdmin ETERNUS DX Disk storage system administrator Administrator Total administrator Monitor Monitor Software Software Custom role Role that is created using the create role command function Optional Th...

Page 364: ...on is enabled after the next login Even if a disabled user account is specified the user account can be deleted In addition if a SSH public key is registered the key is also automatically deleted when this command is executed Syntax Parameter Example s delete user name name name This parameter specifies the user account name to be deleted Only one user name can be specified at the same time The fo...

Page 365: ...ser Role Availability SSH Public Key user1 SecurityAdmin Enable Registered A B C D A User account name B Role name C It shows if the user account is enabled D It shows if an SSH public key is registered The following example displays all of the existing user accounts CLI show users User Name User Role Availability SSH Public Key manager Administrator Enable Registered user1 Monitor Disable Not Reg...

Page 366: ...te Lock IP Address GUI 65535 f ce Maintainer 2012 07 02 10 12 05 No 2001 db8 1234 0 0 9abc A B C D E F G A User interface type B User session ID C User account name D Role name E Login date and time F Resource lock G IP address of logged in users The following example displays the information of the users who are logged in CLI show login users Interface Session ID User Name User Role Login Date Lo...

Page 367: ...arameter Example s set password name name name Optional This parameter specifies the user account name to change a password Only users with the User Management policy can specify this parameter Only one user name can be specified at the same time The new password is confirmed after command input If omitted the password of the currently logged in user is changed The following example changes the pa...

Page 368: ...he existing user accounts Note that only the initial default user is enabled Syntax Parameter Example s initialize all users execution yes no execution This parameter specifies the execution mode User accounts are initialized only when selecting yes yes All the user accounts are initialized no No operation The following example initializes all of the registered user accounts CLI initialize all use...

Page 369: ... filename filename indicator enable disable account name This parameter specifies a user account name used for a certificate key for authentication Only one user name can be specified at the same time port This parameter specifies which Ethernet port is used to connect to the FTP server For details refer to 1 11 Note for Specifying FTP Server page 31 maintenance MNT port remote RMT port fst FST po...

Page 370: ...server is cli user and the file that contains the SSH public key is tmp ssh_key1 CLI import ssh public key account name manager port maintenance server ftp a com filename tmp ssh_key1 user cli user Password An Operator should input a password which is hidden importing tmp ssh_key1 from ftp a com complete The following example is the same as above except that the progress indicator is not displayed...

Page 371: ... specified user account is disabled at that time the SSH public key can be deleted Syntax Parameter Example s delete ssh public key account name account_name account name This parameter specifies an existing user account name with the SSH certificate key registered for authentication use Only one user account name can be specified at once The following example deletes the SSH public key for the ma...

Page 372: ...entication authorization and accounts of network users This section explains the commands to set authentication authorize and account by the server This command sets up the RADIUS authentication server Display settings of the system and the RADIUS authentication server s RADIUS authentication server Secondary Secondary is optional RADIUS authentication server Primary Set up the RADIUS authenticati...

Page 373: ... server must be set in advance or at the same time that this parameter is set RADIUS authentication can be disabled regardless of the primary server setting status enable RADIUS function is enabled disable RADIUS function is disabled after error Optional This parameter specifies what happens when an error occurs If this parameter is omitted this setting is not changed internal Authenticate and aut...

Page 374: ...entication Protocol primary shared secret Optional This parameter specifies the shared secret of the primary server up to 64 alphanumeric characters If omitted the existing setting is not changed primary retry timeout Optional This parameter specifies the retry timeout value of the primary server If omitted 30 seconds default value is used The timeout value should be selected from following values...

Page 375: ...thods can be specified chap Use CHAP Default pap Use PAP PAP Password Authentication Protocol secondary shared secret Optional This parameter specifies the shared secret of the secondary server Up to 64 alphanumeric characters can be specified for the shared value If omitted the existing setting is not changed secondary retry timeout Optional This parameter specifies the retry timeout value of the...

Page 376: ...yyyyyyyyyyyy M Secondary retry timeout 20 N A Mode Display the system s mode B Displays which method used after found error C FQDN or IP address IPv4 or IPv6 of the primary authentication server D Port that is used for primary settings E Port number of the primary authentication server for the authentication protocol F Authentication method type of the primary authentication server G Shared secret...

Page 377: ...ver is not valid CLI show radius RADIUS authentication Enable After error No Primary server 10 21 134 198 Primary port MNT Primary port number 1812 Primary authentication mode CHAP Primary shared secret xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Primary retry timeout 20 Secondary server Secondary lan port RMT Secondary port number 1912 Secondary authentication mode PAP Secondary shared secret yyyyyyyyyyyyyy...

Page 378: ...y in units of a volume using CLI For details about setting parameters for each command refer to this manual Note that snapshots of the specified volume are created by the ETERNUS Advanced Copy function for the ETERNUS DX Disk storage system The purposes of the Advanced Copy function such as creating backups and replications and the procedure for using the Advanced Copy function via OS or software ...

Page 379: ... must be considered when deciding the size of the copy destination area By its nature SnapOPC is best used for the temporary backup to tape of file server files and other low modification rate data as provision against operating failures and software errors 4 2 2 Preparations for the Advanced Copy Function 4 2 2 1 Basic Settings License registration Register a license for using the Advanced Copy f...

Page 380: ...uired for Advanced Copy management and is allocated as a table size The table size and resolution settings are determined by the copy capacity and the number of sessions volumes that will be run simultaneously S1 Refers to the table size MB for OPC QuickOPC SnapOPC SnapOPC without EC REC and OPC Restoration S2 Refers to the table size MB for OPC QuickOPC SnapOPC SnapOPC with OPC Restoration S3 16 ...

Page 381: ...kOPC SnapOPC SnapOPC or REC copy source and the REC copy source the copy capacity is the total capacity of both The copy capacity for multi copy sessions and for generation management by SnapOPC sessions is the total capacity of copy source volumes slices or partitions multiplied by the number of copy destinations or generations for each copy source Example Copy area in the copy source logical vol...

Page 382: ...anual for how to create a RAID group When considering the effect on performance creating SDVs in a RAID group that is not used for the operation is recommended although the SDVs can be created in an existing RAID group SDV Snap Data Volume creation Create SDVs the copy destination for SnapOPC in the RAID group created in step 1 Example Creating one SDV with 10 GB virtual capacity in RAID group 2 A...

Page 383: ... Session Management 4 2 3 1 Copy management After preparation for Advanced Copy is complete create a copy session to start copying volumes During operation also check the status of the copy sessions and delete unnecessary copy sessions SnapOPC copy execution Create a copy session by using the start advanced copy command to start the SnapOPC copy Example Starting the SnapOPC copy from the copy sour...

Page 384: ...sed by the deleted copy sessions are released Data in the copy destination volume loses its meaning becomes undefined Example Deleting the copy session with copy session ID 1 Monday CLI start advanced copy source volume number 0 destination volume number 100 Tuesday CLI start advanced copy source volume number 0 destination volume number 101 Wednesday CLI start advanced copy source volume number 0...

Page 385: ... changed only once by registering another trial version license If a second attempt is made an error occurs In addition when a trial version license key is registered again the trial period may be shortened due to the valid period of the license key Syntax Parameter Example s set advanced copy license key key type free vaai key or type This parameter specifies the Advanced Copy license key or the ...

Page 386: ...stered Advanced Copy license Syntax Parameter Example s delete advanced copy license execution yes no execution This parameter confirms that the operation should proceed The Advanced Copy license is deleted only when the user explicitly specifies execution yes yes The registered Advanced Copy license is deleted no No operation The following example deletes the registered Advanced Copy license CLI ...

Page 387: ...ense is registered If the license is not trial it does not appear D Local copy trial license expiration date If the license is not trial it shows as E Remote copy license status Trial and Registered F Registration date of the trial version license for remote copy is displayed for license that is not the trial version G Remote copy how many times the trial license is registered If the license is no...

Page 388: ...license ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 388 The following example displays the status of the free Advanced Copy license for the ETERNUS DX80 S2 DX90 S2 CLI show advanced copy license Copy Status Trial registration Trial expiration Type Date Date Free VAAI ...

Page 389: ...reshold level This parameter specifies the policy level of the Advanced Copy Only one policy level can be specified at the same time information Information level Settable range is 1 97 Default value is 50 warning Warning level Settable range is 2 98 Default value is 70 error Error level Settable range is 3 99 Default value is 99 threshold This parameter specifies a threshold corresponding to the ...

Page 390: ...yntax Parameter No parameters Output Example s show advanced copy policy SDP ID Information Warning Error 0 50 90 99 A B C D A Snap data pool number B Threshold value that is registered as the Advanced Copy policy Information level C Threshold value that is registered as the Advanced Copy policy Warning level D Threshold value that is registered as the Advanced Copy policy Error level The followin...

Page 391: ...lution If omitted the existing setting is not changed 1 1 default 2 2 4 4 8 8 16 16 table size Optional This parameter specifies the Advanced Copy table size The size can be specified in multiples of 8MB Note that the maximum value depends on the memory size that is to be installed in the controllers The initial value is set to 0MB If omitted the existing setting is not changed The maximum Advance...

Page 392: ...t The initial value is set to 80 If omitted the existing setting is not changed In addition the system has a function that notifies users when this value reaches the specified upper limit value This upper limit value is set by using this parameter For details refer to the show event notification command copy schedule mode Optional This parameter specifies the Copy Schedule Mode If omitted the exis...

Page 393: ...g I A Resolution B Advanced Copy table size C EC OPC priority and EC OPC rate mode that is currently set in the system Example Auto Very Low Priority Low Priority Middle Priority High Priority D EC OPC priority that is currently used E Resolution of a snap data pool volume F Threshold value of the Advanced Copy table usage G Advanced Copy table size that is currently used H Usable Advanced Copy ta...

Page 394: ...n snap data volumes cannot be specified Syntax Parameter Example s initialize snap data volume volume number volume_numbers volume name volume_names volume number or volume name This parameter specifies the Snap Data Volume SDV identifiers to be initialized One or more SDVs can be specified at the same time For details refer to 1 2 9 Volume Syntax page 22 The following example initializes the cons...

Page 395: ...ed For details refer to 1 2 9 Volume Syntax page 22 Volume Status Size MB Logical Physical Host Used Copy Used Host SDP Copy SDP No Name Size MB Size MB Size MB Size MB Using Size MB Using Size MB 100 SDV001 Available 102400 5120 4144 3120 1024 3120 1024 A B C D E F G H I J A Snap data volume number B Snap data volume name C Volume status D Volume size unit MB E Logical size of SDV unit MB F Physi...

Page 396: ... A B C Encrypted 4096 0 4096 D E F Snap Data Pool Volume List No Name Status Reserved Deletion Size MB 0 sdpv1 Available No 5120 G H I J K A Total size as unencrypted data unit GB B Size directly updated from a host as unencrypted data unit GB C Size that is using the SDP for copying due to a shortage of SDV capacity as unencrypted data unit GB D Total size as encrypted data unit GB E Size directl...

Page 397: ... LIMITED P2X0 1030 09ENZ0 397 Example s The following example displays the SDPs CLI show snap data pool Snap Data Pool Information Total Size GB Host Size GB Copy Size GB Unencrypted 4 0 0 Encrypted 0 0 0 Snap Data Pool Volume List No Name Status Reserved Deletion Size MB 2 SDPV 01 Not Ready No 2048 3 SDPV 11 Partially Exposed Rebuild No 2048 ...

Page 398: ...arameter specifies the SDPV identifiers to be deleted One or more volumes can be specified at the same time For details refer to 1 2 9 Volume Syntax page 22 mode This parameter specifies the deletion mode force The SDPV is immediately deleted even when an SDP element SDPE has been assigned to it Up to 128 volumes can be specified at the same time reservation The SDPV is deleted when the SDPE is no...

Page 399: ...me name sdv_name source volume number or source volume name This parameter specifies the volume identifier of the copy source The type must be OPEN Only one volume can be specified at the same time For details refer to 1 2 9 Volume Syntax page 22 destination volume number or destination volume name This parameter specifies the volume identifier of copy destination The type must be SDV Only one vol...

Page 400: ...xample session id 0 Only 0 session id 0 1 0 and 1 session id 2 5 2 to 5 session id 0 2 5 0 and 2 to 5 delete mode Optional This parameter specifies the deletion mode This parameter can be specified for any type of Advanced Copy session If forced is specified the specified session and all the sessions before the specified session are forcibly deleted If omitted this parameter is handled as though n...

Page 401: ...n Reserved status can only be distinguished as being either OPC EC XCOPY or ODX In this case sessions that are distinguished as OPC or EC may be determined as being another type of session once the type of copy session can be confirmed show advanced copy sessions session id id type all ec opc qopc sopc sopc mon rec xcopy odx requestor all gui cli guicli smis scsi lan volume type all open standard ...

Page 402: ...ith this parameter all Sessions to be displayed are not restricted by the requesters If omitted this operand is assigned gui Only sessions being started from GUI are displayed cli Only sessions being started from CLI are displayed guicli Only sessions being started from both GUI and CLI are displayed smis Only sessions being started from SMI S are displayed scsi Only sessions being started from SC...

Page 403: ...s Only when GS License is registered When a list is displayed SID Gene Type Volume Source Volume Destination Volume Status Phase Error Requestor ration Type No Name No Name Code 0 1 12 SnapOPC Standard 8000 VOLUME0000123456 4000 VOLUME1111123456 Active 0x00 CLI A B C D E F G H I J K L A The session ID of this system is displayed in decimal number B The generation is displayed only when the type Sn...

Page 404: ...a list is displayed M The copy source Start Logical Block Address LBA in the specified range is displayed in 16 digit hexadecimal N The copy destination Start LBA in the specified range is displayed in 16 digit hexadecimal O Total Data Size is displayed P Copied Data Size is displayed Q Modified Data Size is displayed R Used Snap data pool capacity is displayed when the type SnapOPC or SnapOPC is ...

Page 405: ...egular Trial Unknown e The copy range is displayed Totally Extent f It indicates whether the Secondary area can be accessed when the Status is Active Read Only at Equivalency No Read Write g It indicates the transition status of Concurrent Suspend Normal Exec Error Unknown h It indicates the execution result of the Change command Normal Mode Change Error Reverse Error i It indicates the estimated ...

Page 406: ... 1 QuickOPC Standard 8002 VOLUME0000123457 4002 VOLUME1111123457 Active Tracking Copying 0x00 SMI S 2 Monitor Standard 8003 VOLUME111 Active Copying 0x00 GUI 3 EC Standard 8004 VOLUME001 4004 VOLUME002 Active Equivalent 0x00 GUI 4 EC Standard 8005 VOLUME005 4005 VOLUME505 Suspend Copying 0x00 GUI 5 OPC Standard 8006 VOLUME006 4006 VOLUME606 Active 0x00 GUI 6 REC Standard 8007 VOLUME007 4007 VOLUME...

Page 407: ... Name No Name Code 3 EC Standard 8004 VOLUME001 4004 VOLUME002 Active Equivalent 0x00 GUI Source Block Address LBA 0x1234567890123456 Destination Block Address LBA 0x1234567890123456 Total Data Size MB 1024 Copied Data Size MB 512 Modified Data Size MB SDP Used Capacity MB SDP ID assigned to SDV Direction Sync Transfer Mode Recovery Mode Split Mode Remote Session ID Remote Box ID Time Stamp 2010 1...

Page 408: ...icense commands The CLI commands for Remote Equivalent Copy are listed in the following table This section explains the CLI commands related to the environment settings used to control the REC The minimum requirements for both the copy source storage system and the copy destination storage system is a path information file that defines the data transmission line and related performance boosting se...

Page 409: ...ource and the copy destination If a syntax error is detected the command will terminate with an error message and an error line Make sure that the information in the REC path information file matches the actual setup 4 Measure and apply round trip times Firstly measure the round trip time using the measure rec round trip time command in automatic mode and apply it in the system Individual round tr...

Page 410: ...abel names must be in lowercase The following is a correct example The following example has an uppercase label a syntax error Lines starting first non space character with a hash mark are handled as comment lines The following example shows a correct comment line Back up REC Path Information FTP server ETERNUS DX90 S2 3 GUI ETERNUS DX90 S2 2 CLI ETERNUS DX90 S2 1 CLI import rec path convert rec p...

Page 411: ...ring must be described from the first line and 1 column Any space characters must not be inserted Storage system definitions box id DXL storage 10 storage10 eternus rec path text 0101 storage Defines an identification number 0 127 for each of the local and remote storage systems Usable numbers can be freely selected within this range The following example uses 0 as the storage system id number sto...

Page 412: ...mand The limitation for the number of characters for each iSCSI parameter is as follows iSCSI name At least 4 and a maximum of 223 RA port CHAP authentication username At least 1 and a maximum of 63 RA port CHAP authentication password At least 12 and a maximum of 32 When CHAP authentication is disabled CHAP authentication username and password should be omitted Alias At least 0 and a maximum of 3...

Page 413: ...pe paths The following example specifies 100 Mbit s as the effective line speed line speed 100 port link cmX caY portZ cmW caV portU Respectively defines the target host interface ports in the local and remote storage systems in the same order as used in the storage link field In the following example for the storage link 5 6 used in the above storage system definition example cm0 ca0 port1 belong...

Page 414: ... example path information file that follows is based on the path topology shown below CM 1 CM 0 CM 0 CM 0 CM 1 storage system 0 CM 1 port 0 port 1 port 2 port 3 CM 1 port 0 port 1 port 0 port 1 port 2 port 3 port 0 port 1 CA1 CA0 port 0 port 1 port 2 port 3 port 0 port 1 CA1 CA0 CA2 CM 0 port 0 port 1 CA3 Storage system 1 Storage system 2 Storage system 3 ...

Page 415: ... port2 40000000abc80e42 cm1 ca2 port3 40000000abc80e43 Storage system 2 storage 2 box id 00DXL ET06F21AUABCPJ000002 device type 4 4 cm1 ca0 port0 40000000abc80e42 cm1 ca0 port1 40000000abc80e43 Storage system 3 storage 3 box id 00ETERNUSDXMS2ET00000A EI000003 device type 4 5 cm0 ca3 port0 irq 2010 12 com fujitsu storage system eternus dx400 00040080 10 11 12 93 eternus bamboo n3p030 cm0 ca3 port1 ...

Page 416: ...several partitions for each CM The maximum number of partitions in the system is 8 1 The maximum size of a partition is 2048MB and the minimum is 128MB Each partition is handled by specifying its partition number from 0 to 7 1 1 These are the specification values for the ETERNUS DX440 S2 Values differ among models and types For details refer to the set rec buffer command The following example show...

Page 417: ...tings through CLI The steps involved in settings an REC disk buffer using CLI are as follows Procedure 1 Create REC disk buffer To create an REC disk buffer choose four disks that do not belong to a RAID group by using the create rec disk buffer command Then create a volume from this RAID group This is a RAID group that can be displayed by using the show rec disk buffer command 2 Format REC disk b...

Page 418: ...ing the REC disk buffer through CLI To release the REC disk buffer from the REC buffer use the release rec disk buffer command This can be confirmed by using the show rec disk buffer command To delete an REC disk buffer use the delete rec disk buffer command REC buffer partition 2 REC Disk Buffer RECDB0001 400 401 423 500 501 523 Volume Use four disks create rec disk buffer set rec disk buffer Ass...

Page 419: ...ained When the port mode is switched from the RA mode or the CA RA auto mode to another mode the line number REC Line No setting of the port is changed to the default value 0 When the port mode is switched from the RA mode to the CA RA auto mode or vice versa the line number REC Line No setting for the port is retained set host port mode port xyz all mode ra ca cara initiator port This parameter s...

Page 420: ...0 1030 09ENZ0 420 Example s The following example switches host interface port 0 on CM 1 CA 0 to RA mode CLI set host port mode port 100 mode ra The following example reverts port 3 on CM 1 CA 0 to CA mode CLI set host port mode port 103 mode ca The following example switches all the host interface ports to RA mode CLI set host port mode port all mode ra ...

Page 421: ...face port Syntax Parameter No parameters Output Example s show host port mode Port Mode CM 0 CA 0 Port 0 RA A B A A location of a host interface port B Operation mode for a host interface port The following example displays operation mode that is set to all the host interface ports on a system CLI show host port mode Port Mode CM 0 CA 0 Port 0 RA CM 0 CA 0 Port 1 OCLINK CM 0 CA 1 Port 0 CA CM 0 CA...

Page 422: ...icator enable disable port This parameter specifies which Ethernet port is used to connect to the FTP server For details refer to 1 11 Note for Specifying FTP Server page 31 maintenance MNT port remote RMT port fst FST port server This parameter specifies the name of the FTP server that contains the REC path information file The server name format is IPv4 standard notation a base 256 d d d d strin...

Page 423: ...FTP server the user name is cli user and the filename is tmp rec path1 txt CLI import rec path port maintenance server ftp a com filename tmp rec path1 txt user cli user Password Operator inputs password but it is hidden importing tmp rec path1 txt from ftp a com complete The following example is the same as above except that the progress indicator is not displayed CLI import rec path port mainten...

Page 424: ...ly appended when the input characters are less than 40 When the parameter is omitted Remote Storage System E Remote Box ID Path Type Line Speed Round Trip Multiplicity Priority Copy Schedule Mbit s Time ms Current Recommended Level Mode 00DXL ET06F21AUABCPJ000002 Direct 3 Session 00DXL ET06F21AUABCPJ000004 Switched 10 20 4 3 Destination A B C D E F G H I A Error sign If mark is output it means tha...

Page 425: ...ice C The error occurs in the cable O The error occurs in the local device or adapter other than the remote device This occurs only when the connection type is FC AL S The error occurs in the switch or switch settings I The error occurs in the FC RA port or iSCSI RA port on the local device M The error occurs in the memory O P A Box ID of a local storage system B Box ID of the specified remote sto...

Page 426: ...D0C40085 Error detail description s R The copy path between the local device and remote device is in unstable status For example link down repeatedly occurs in a certain period of time or communication fails B The resolution settings are different between the local and remote devices T The error occurs in the FC RA port or iSCSI RA port on the remote device C The error occurs in the cable I The er...

Page 427: ...the originally imported path information file was also TEXT type the TEXT type exported backup file may not be identical export backup rec path port maintenance remote fst server server_name user login_user_account filename filename type text binary indicator enable disable port This parameter specifies which Ethernet port is used to connect to the FTP server For details refer to 1 11 Note for Spe...

Page 428: ...FTP server named ftp a com using the Maintenance use Ethernet port MNT port For the FTP server the user name is cli user and the filename is tmp rec path1 txt The file type is TEXT CLI export backup rec path port maintenance server ftp a com filename tmp rec path1 txt user cli user type text Password Operator inputs password but it is hidden exporting tmp rec path1 txt from ftp a com complete The ...

Page 429: ...ked up in a system The information includes date and file size of the backup file Syntax Parameter No parameters Output Example s show backup rec path information Date 2009 06 02 15 24 17 A File Size 51224 Bytes B A Date of the backed up path information file B File size of the backed up path information file The following example displays the date and file size of the backup REC path information ...

Page 430: ...sk storage system Conversion Logic input file TEXT output file BINARY convert rec path port maintenance remote fst server server_name user login_user_account source file source_file output file output_file mode t2b b2t indicator enable disable port This parameter specifies which Ethernet port is used to connect to the FTP server For details refer to 1 11 Note for Specifying FTP Server page 31 main...

Page 431: ...tion file to the FTP server named ftp a com using the Maintenance use Ethernet port MNT port and exports the file to the server after the file is converted For the FTP server the user name is cli user and the conversion source filename is tmp rec path txt and the conversion destination filename is tmp bin rec_path bin The conversion mode is a direction from TEXT type to BINARY CLI convert rec path...

Page 432: ...ode Round trip times are measured for all remote storage systems for which the round trip time has not yet set and these times are set to the system as base information to optimize REC performance This mode is recommended for initial setup manual Manual mode Round trip times are measured for the specified single remote storage system The displayed times can then be saved to the system if desired r...

Page 433: ...otherwise affected CLI measure rec round trip time mode auto The following example displays the measured round trip time and confirms with the operator whether or not the result is to be saved to the system In this example the measured round trip time is reflected to the system CLI measure rec round trip time mode manual remote boxid 00DXL ET06F21AUAB CPJ000002 Remote Box ID Round Trip Time ms 00D...

Page 434: ...ound trip time remote boxid remote_storage_system_box_id time round_trip_time remote boxid This parameter specifies the Box ID of a single remote storage system This is the storage system for which the REC round trip time is to be manually set Box IDs use a maximum of 40 alphanumeric characters spaces and pound key characters All alphabetic characters are handled as uppercase Hash marks are automa...

Page 435: ... the storage system for which the REC multiplicity is to be manually set Box IDs use a maximum of 40 alphanumeric characters spaces and pound key characters All alphabetic characters are handled as uppercase The pound key characters are automatically appended when the input characters are less than 40 multiplicity This parameter specifies the REC multiplicity value for remote connections From 1 to...

Page 436: ...s the REC multiplicity to 5 CLI set rec multiplicity remote boxid 00DXL ED06F21AUABCPJ000001 multiplicity 5 The following example sets the Copy Level to 3 CLI set rec multiplicity remote boxid 00DXL ED06F21AUABCPJ000001 priority level 3 The following example sets the Copy Schedule Mode to Session balancing CLI set rec multiplicity remote boxid 00DXL ED06F21AUABCPJ000001 copy schedule mode ses sion...

Page 437: ... that the upper limit value depends on the memory size that is installed in the controllers ETERNUS DX90 S2 512MB ETERNUS DX410 S2 4096MB ETERNUS DX440 S2 8192MB ETERNUS DX8100 S2 DX8700 S2 8192MB Syntax Parameter Receive and Send REC buffers must both be independently defined if the REC buffer is to be used bi directionally set rec buffer partition 0 1 2 3 4 5 6 7 remote boxid storage_system_box_...

Page 438: ...must be specified for the initial setup If omitted this parameter value is not changed The size of each REC buffer can be selected as follows ETERNUS DX90 S2 128MB 256MB and 512MB ETERNUS DX410 S2 DX440 S2 128MB 256MB 512MB 1024MB and 2048MB ETERNUS DX8100 S2 DX8700 S2 128MB 256MB 512MB 1024MB 2048MB buffer type Optional This parameter specifies the REC buffer type This parameter must be specified...

Page 439: ...halted to allow priority processing of the server responses This parameter must be specified for the initial setup If omitted this parameter value is not changed 0 Disabled 1 15 1 to 15 minutes 5 minutes is recommended io response mode Optional Specifying enable for this parameter may improve the Write I O response during initial copying of an REC Consistency mode copy session If heavy load Write ...

Page 440: ...lay 4 2 Advanced Copy Management set rec buffer ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 440 The following example changes the defined size of partition 2 to 256MB CLI set rec buffer partition 2 buffer size 256mb ...

Page 441: ...efinition Syntax Parameter Example s delete rec buffer partition 0 1 2 3 4 5 6 7 partition This parameter specifies the REC buffer group number that is to be deleted This number starts from 0 Two or more numbers cannot be specified at the same time The selectable range is as follows ETERNUS DX90 S2 0 to 3 ETERNUS DX400 S2 Series 0 to 7 ETERNUS DX8000 S2 Series 0 to 7 The following example deletes ...

Page 442: ... G H I J K A Assigned partition number B REC buffer Usage C Box ID of a storage system that uses an REC buffer D REC buffer status E REC buffer size F Forwarding interval unit second G Monitoring time unit minute H HALT wait timer unit second I I O response priority mode J Immediate Halt mode K REC buffer volume copy type When the GS License is registered The following example displays the REC buf...

Page 443: ...disks This parameter specifies which disks will form the RAID group For details refer to 1 2 3 Disk Syntax page 19 Specify four disks that are not used with other RAID groups encryption Optional This parameter specifies whether the encryption by a CM is performed The following parameters can be specified enable The REC disk buffer data is encrypted disable The REC disk buffer data is not encrypted...

Page 444: ...odule 6 CPU 1 cm7cpu0 Controller module 7 CPU 0 cm7cpu1 Controller module 7 CPU 1 auto Automatically default stripe depth Optional This parameter specifies the stripe depth for the REC Disk Buffer that is to be created If omitted it is handled as if 64kb is specified 64kb 64k Byte 128kb 128k Byte Only for RAID 5 configurations of 10 or more disks RAID 0 configurations and RAID1 0 configurations 25...

Page 445: ... can be specified for each storage system model are as follows ETERNUS DX90 S2 0 to 3 ETERNUS DX410 S2 DX440 S2 0 to 7 ETERNUS DX8100 S2 DX8700 S2 0 to 7 rg number or rg name This parameter specifies the RAID group identifier of the REC disk buffer for assignment of the REC buffer One to four parameter s can be specified For details refer to 1 2 8 RAID Group Syntax page 22 The following example as...

Page 446: ... REC disk buffer Syntax Parameter Example s delete rec disk buffer rg number rg_numbers rg name rg_names rg number or rg name This parameter specifies the RAID group identifier of the REC disk buffer for assignment of the REC buffer One or more RAID groups can be specified For details refer to 1 2 8 RAID Group Syntax page 22 The following example deletes the REC disk buffer that was created as RAI...

Page 447: ...hecked by using the show raid groups command Syntax Parameter show rec disk buffer partition partition_numbers partition Optional This parameter specifies the REC buffer partition number for REC disk buffers One or more numbers can be specified If this parameter is specified the CM CPU information is also displayed This number starts from 0 The selectable range is as follows ETERNUS DX90 S2 0 to 3...

Page 448: ... used this REC disk buffer F Elapsed time of between last copy worked time to current time G Total REC disk buffer capacity H Total REC disk buffer size which used to send data stored I Total REC disk buffer remain size J Number of RLU that associated RLU REC disk buffer K Associated RAID group 1 L Associated RAID group 2 M Associated RAID group 3 N Associated RAID group 4 O CM CPU number indicati...

Page 449: ...sk buffer s Syntax Parameter Example s format rec disk buffer rg number rg_numbers rg name rg_names rg number or rg name This parameter specifies the RAID group identifier of the REC disk buffer for assignment of the REC buffer One or more RAID groups can be specified For details refer to 1 2 8 RAID Group Syntax page 22 The following example formats the REC disk buffers that are assigned to RAID g...

Page 450: ... One or more parameters can be specified at the same time The number of partitions available depends on the system model as follows ETERNUS DX90 S2 0 to 3 ETERNUS DX410 S2 DX440 S2 0 to 7 ETERNUS DX8100 S2 DX8700 S2 0 to 7 rg number or rg name This parameter specifies the RAID group identifier of the REC disk buffer that is assigned to the REC buffer One or more RAID groups can be specified For de...

Page 451: ...UJITSU LIMITED P2X0 1030 09ENZ0 451 4 3 Network Management This section explains commands related to the following network operations System network configurations SNMP configurations SMI S configurations Secure server keys 4 3 1 Network Settings This section explains the commands related to network connectivity ...

Page 452: ...aster connect ip ip_address slave connect ip ip_address netmask netmask subnet prefix length length gateway gateway allow ip1 ip_address netmask allow ip2 ip_address netmask allow ip3 ip_address netmask allow ip4 ip_address netmask allow ip5 ip_address netmask allow ip6 ip_address netmask allow ip7 ip_address netmask allow ip8 ip_address netmask allow ip9 ip_address netmask allow ip10 ip_address n...

Page 453: ...isabled the port becomes disabled This does not apply to the ETERNUS DX80 S2 DX90 S2 Both the maintenance port and the remote port must be enabled for the ETERNUS DX410 S2 DX440 S2 slave ip Optional This parameter specifies the IP address of the slave CM The format is IPv4 standard notation a base 256 d d d d string This parameter cannot be specified for a single controller type If omitted the exi...

Page 454: ...ique local unicast addresses can be specified for the connect IP address If omitted the existing setting is not changed This parameter can only be specified when v6 is specified for the ip format parameter and disable is specified for the ipv6 set auto parameter Example slave connect ip 2003 120 84d 7ac 45 netmask Optional This parameter specifies the subnet mask for the specified Ethernet port Th...

Page 455: ...ecified The types of IPv6 addresses that can be specified are global unicast addresses including 6to4 addresses and unique local unicast addresses If omitted no changes are made to the table of allowed addresses This setting is not required to allow connection from the local sub network sub network to which the system network addresses belong This parameter can only be specified when v6 is specifi...

Page 456: ...sses must be specified in IPv6 address format This parameter cannot be specified when port fst is specified secondary dns ip Optional This parameter specifies the secondary DNS IP address for the Ethernet port The format is IPv4 standard notation a base 256 d d d d string or IPv6 format The types of IPv6 addresses that can be specified are global unicast addresses including 6to4 addresses and uniq...

Page 457: ...nance master ip 10 10 10 1 netmask 255 255 0 0 gateway 10 10 10 250 allow ip1 10 11 0 0 255 255 0 0 allow ip2 192 168 1 1 The following example changes the Ethernet speed of the maintenance port MNT port to 100Mbit s full duplex CLI set network port maintenance speed 100full The following example sets the IP address in IPv6 address format CLI set network port maintenance ip format v6 ipv6 set auto...

Page 458: ...dress Speed and Duplex Auto Negotiation Connection speed of MNT port Allowed IP1 192 168 2 0 255 255 255 0 Allowed IP2 10 10 10 0 255 255 255 0 IP address Subnet mask IP address Subnet mask Allowed IP15 192 168 9 0 255 255 255 0 Allowed IP16 10 10 17 0 255 255 255 0 IP address Subnet mask IP address Subnet mask The list of Allowed IP1 16 is accessible terminals through MNT port Wake on LAN Disable...

Page 459: ...sk of RMT port Gateway 192 168 128 250 Gateway address of RMT port Primary DNS 192 168 128 253 Secondary DNS 192 168 128 254 Primary and secondary DNS IP address of RMT port Speed and Duplex Auto Negotiation Connection speed of RMT port Allowed IP1 192 168 129 0 255 255 255 0 Allowed IP2 10 10 10 1 255 255 255 0 IP address Subnet mask IP address Subnet mask Allowed IP15 192 168 136 0 255 255 255 0...

Page 460: ...Pv4 settings are enabled or disabled Enable Disable Master IP 192 168 128 1 IP address of the FST port on master CM Slave IP 192 168 128 1 IP address of the FST port on slave CM This is not displayed for a single controller type Subnet Mask 255 255 255 0 Subnet mask of the FST port Speed and Duplex Auto Negotiation Connection speed of the FST port MAC Address CM 0 41 42 43 44 45 46 CM 1 51 52 53 5...

Page 461: ...4 5 6 7 8 Master Connect IP 1 2 3 6 7 8 Slave Link Local IP fe80 b c d e f 10 11 Slave Connect IP a b c d Length of Subnet Prefix 64 Gateway c0 a8 1 fa ff ff ff 0 Primary DNS c0 a8 1 fd Secondary DNS c0 a8 1 fe Allowed IP1 c0 c8 2 64 Allowed IP2 0 Allowed IP3 0 Allowed IP4 0 Allowed IP5 0 Allowed IP6 0 Allowed IP7 0 Allowed IP7 0 Allowed IP9 0 Allowed IP10 0 Allowed IP11 0 Allowed IP12 0 Allowed I...

Page 462: ... Secondary DNS Allowed IP1 0 Allowed IP2 0 Allowed IP3 0 Allowed IP4 0 Allowed IP5 0 Allowed IP6 0 Allowed IP7 0 Allowed IP7 0 Allowed IP9 0 Allowed IP10 0 Allowed IP11 0 Allowed IP12 0 Allowed IP13 0 Allowed IP14 0 Allowed IP15 0 Allowed IP16 0 MAC Address CM 0 21 22 23 24 25 26 CM 1 31 32 33 34 35 36 FST port Enable Ipv4 Enable Master IP 192 168 134 1 Slave IP 192 168 134 2 Subnet Mask 255 255 2...

Page 463: ...is used For the ETERNUS DX80 S2 DX90 S2 the initial all ports open state can be restored by pushing the IP RESET switch of the system However it should be noted that this will also clear all the network information For further information refer to ETERNUS DX80 S2 DX90 S2 Disk storage system User s Guide Installation When any settings except for ICMP are changed the CLI session is automatically dis...

Page 464: ...t is opened or closed If omitted the existing setting is not changed The initial state is open open Application port telnet is opened close Application port telnet is closed ssh Optional This parameter specifies if the SSH Secure Shell application port is opened or closed If omitted the existing setting is not changed The initial state is open open Application port SSH is opened close Application ...

Page 465: ...orts for both GUI and CLI connections This parameter must be specified in either of the following cases When disabling all of the service ports for both GUI and CLI connections HTTP HTTPS telnet and SSH When disabling both of the service ports for CLI connections telnet and SSH In all other cases this parameter is ignored For example if a command such as set firewall port remote icmp close confirm...

Page 466: ...direct Test Closed RMT Port http Closed https Closed telnet Closed SSH Open Maintenance Secure Closed ICMP Closed SNMP Closed FST Port http Closed https Closed telnet Closed SSH Open Maintenance Secure Closed ICMP Closed MNT port Maintenance Ethernet port RMT port Remote Ethernet port FST port FST Ethernet port The port status of application service http https telnet SSH ETERNUS Maintenance Secure...

Page 467: ...he status of each application service port CLI show firewall MNT Port http Closed https Closed telnet Closed SSH Open Maintenance Secure Closed ICMP Closed SNMP Closed RCIL Closed IP Redirect Test Closed RMT Port http Closed https Closed telnet Closed SSH Open Maintenance Secure Closed ICMP Closed SNMP Closed FST Port http Closed https Closed telnet Closed SSH Open Maintenance Secure Closed ICMP C...

Page 468: ...is section explains the commands that are related to SNMP settings MIB view controls community controls and SNMP trap controls ETERNUS DX Disk storage system supports SNMP v1 v2c and v3 SNMP configuration settings SNMP manager settings SNMP MIB view settings SNMP user settings SNMP community profile settings SNMP trap settings Exporting enhanced SNMP MIB files ...

Page 469: ...nce MNT port default remote RMT port authentication failure Optional This parameter specifies if the SNMP authentication failure function is enabled This function is used to notify the operator of Authentication Failure by an SNMP trap when this system is accessed from a undefined SNMP community If omitted the existing setting is not changed The initial value is enabled enable An SNMP trap is noti...

Page 470: ...nmp function disable The following example uses the Remote port RMT port for SNMP CLI set snmp port remote The following example uses the specified engine identifier CLI set snmp engine id 0x800102030405060708090a0b0c0d0e0f101112131415161718191a1b1c1d1e1f The following example uses the default engine identifier CLI set snmp engine id default The following example uses MIB II RFC4293 CLI set snmp m...

Page 471: ...d from undefined SNMP communities D It shows an engine identifier E It shows when the engine identifier is the default Even if the engine identifier is the same as the default value when using the set snmp command with a engine id parameter that is not default it does not appear F It shows the version of MIB II that is used by the ETERNUS DX Disk storage system The following example displays the S...

Page 472: ...le s create snmp manager ip address ip_address ip address This parameter specifies the SNMP manager IP address To specify the SNMP manager IP address use IPv4 standard notation a base 256 d d d d string or the IPv6 format The SNMP manager IP address cannot be specified with a fully qualified domain name FQDN The types of IPv6 addresses that can be specified are global addresses including 6to4 addr...

Page 473: ...nager settings number This number can be confirmed by using the show snmp manager command ip address This parameter specifies the SNMP manager IP address To specify the SNMP manager IP address use IPv4 standard notation a base 256 d d d d string or the IPv6 format The SNMP manager IP address cannot be specified with a fully qualified domain name FQDN The types of IPv6 addresses that can be specifi...

Page 474: ...p Syntax Parameter Example s delete snmp manager manager number manager numbers manager number This parameter specifies the SNMP manager settings to delete One or more numbers can be specified by using or Example manager number 1 2 4 manager number 6 9 The following example deletes the 4 SNMP manager setting CLI show snmp manager No IP address 1 10 0 0 1 2 172 20 235 1 3 192 168 0 21 4 172 20 235 ...

Page 475: ... snmp manager This command displays the SNMP manager settings Syntax Parameter No parameters Output Example s show snmp manager No IP address 1 10 0 0 1 A B A SNMP manager setting number B SNMP manager IP address The following example displays the SNMP parameters CLI show snmp manger No IP address 1 10 0 0 1 2 172 20 235 1 3 192 168 0 21 5 192 168 10 11 6 192 168 0 254 ...

Page 476: ... with 0 cannot be specified Example 1 01 1 is NG create snmp view view view_name subtree1 subtree1 subtree2 subtree2 subtree3 subtree3 subtree4 subtree4 subtree5 subtree5 subtree6 subtree6 subtree7 subtree7 subtree8 subtree8 subtree9 subtree9 subtree10 subtree10 include subtree subtree_numbers exclude subtree subtree_numbers view This parameter specifies the MIB view name A maximum of 10 MIB views...

Page 477: ...ed by using or If this parameter and the include subtree parameter are omitted include is used as the default for subtree The following example creates the MIB view named 1 3 It includes one sub tree named 1 3 6 1 2 1 in the MIB view CLI create snmp view view xview4 subtree1 1 3 6 1 2 1 include subtree 1 The following example is specified without the subtree2 parameter when subtree1 subtree3 inclu...

Page 478: ...subtree7 subtree8 subtree8 subtree9 subtree9 subtree10 subtree10 include subtree subtree_numbers exclude subtree subtree_numbers view This parameter specifies the name of the MIB view that will be changed Only one view can be specified at the same time Up to 32 characters can be specified for a view name and at least one character must be specified subtree1 subtree10 Optional These parameters spec...

Page 479: ... by using or If this parameter and the include subtree parameter are omitted include is used as the default for subtree The following example adds the sub tree named 1 3 6 1 2 8 to the MIB view named xview4 CLI set snmp view view xview4 subtree2 1 3 6 1 2 8 The following example deletes the sub tree 1 from the SNMP view named xview5 For example sub tree 2 is newly relocated as sub tree 1 CLI set s...

Page 480: ...rameter specifies the MIB view name to be deleted The wildcard asterisk can be to be used to specify the view names of two or more MIBs Specify each part of a view name followed by an asterisk or only use an asterisk The asterisk cannot be specified before the part of each view name Examples are shown below Correct part of view name Correct part of view name Incorrect The following example deletes...

Page 481: ...ws can be specified by both a combination of a part of name and asterisk a wildcard at the same time and just scribing names The wildcard rules are shown below Examples are shown below Correct part of view name Correct part of view name Incorrect When the parameter is omitted xview1 MIB view name When requesting the SNMP MIB view When requesting the SNMP MIB view View name xview4 A Subtree1 Includ...

Page 482: ...ee1 Include 1 3 6 1 2 1 1 1 Subtree2 Include 1 3 6 1 2 1 1 2 Subtree3 Exclude 1 3 6 1 2 1 1 3 The following example displays all the registered MIB views and their sub trees CLI show snmp view view View name ViewALL Subtree1 Include 1 View name View mib2 Subtree1 Include 1 3 6 1 2 1 View name View exmib Subtree1 Include 1 3 6 1 4 1 211 1 21 1 View name xview4 Subtree1 Exclude 1 3 6 1 4 1 211 1 21 ...

Page 483: ...s specified the authentication method and encryption options can be specified In addition the ETERNUS DX Disk storage system confirms the authentication password Between 8 and 64 characters can be used for the password If omitted it is enabled enable Authentication is enabled default disable Authentication is disabled authentication method Optional This parameter specifies which authentication met...

Page 484: ...ITSU LIMITED P2X0 1030 09ENZ0 484 The following example creates the MIB user name FooVar with view xview4 and authentication is disabled CLI create snmp user name FooVar view xview4 authentication disable The following example creates the SNMP user name FooUser without specifying a view name CLI create snmp user name FooUser view ...

Page 485: ... parameter specifies whether to enable authentication If it is specified the authentication method and encryption options can be specified In addition the ETERNUS DX Disk storage system confirms the authentication password Between 8 and 64 characters can be used for the password If omitted the existing setting is not changed enable Authentication is enabled disable Authentication is disabled authe...

Page 486: ...ng example user FooVar is set to SNMP view xview4 the authentication method is set to MD5 and encryption is enabled CLI set snmp user user FooVar view xview4 authentication enable authentication method md5 Current Authentication Password New Authentication Password Confirm Authentication Password Current Encryption Password New Encryption Password Confirm Encryption Password ...

Page 487: ... entry When using number one or more users can be specified using or When number all is specified all of the users are deleted The user number can be confirmed by using the show snmp user command Example name Foo number 1 number 2 3 number 1 4 The following example deletes the SNMP user named FooVar CLI delete snmp user user FooVar The following example deletes SNMP users number 2 and 4 CLI show s...

Page 488: ...ollowing example deletes the SNMP users from number 1 to 3 CLI show snmp user No User name Authentication Encryption MIB view 1 FooVar1 MD5 enable xview4 2 FooVax SHA disable xview5 3 BUZZ disable disable view11 4 snmpuser1 MD5 enable view13 CLI delete snmp user number 1 3 CLI show snmp user No User name Authentication Encryption MIB view 4 snmpuser1 MD5 enable view13 ...

Page 489: ... the registered SNMP users are listed Example name Foo number 1 number 2 3 number 1 4 No User name Authentication Encryption MIB view 1 FooVar1 MD5 enable xview4 A B C D E A User number B User name C Authentication method or disable D Encryption enable or disable E MIB view name The following example displays a list of all the registered SNMP users CLI show snmp user No User name Authentication En...

Page 490: ...SNMP users numbering from 2 to 4 CLI show snmp user number 2 4 No User name Authentication Encryption MIB view 2 FooVax SHA disable view4 3 BUZZ disable disable 4 snmpuser1 MD5 enable view13 The following example displays the SNMP users numbering from 1 and 5 CLI show snmp user number 1 5 No User name Authentication Encryption MIB view 1 FooVar1 MD5 enable xview4 5 snmpuser2 SHA enable View exmib ...

Page 491: ...he information that a manager can retrieve from the agent Read Only authority is granted to SNMP manager requests that match a community profile It is not possible for a profile to grant any authority other than read only Syntax Parameter create community profile community community_name view view_name manager number manager_numbers none community This parameter specifies the SNMP community name w...

Page 492: ... xview4 The following example creates the SNMP community in which the SNMP community is named community2 the SNMP manager number is 2 and the SNMP MIB view is able to access all MIB views CLI create community profile community community2 manager number 2 view xview5 The following example creates an SNMP community that is used only for traps CLI create community profile community community3 manager...

Page 493: ...community that already exists view Optional This parameter specifies the SNMP MIB view name that is accessible by members of the community If the specified community is changed to be used for traps only specify double quotation marks instead of a view name manager number Optional This parameter specifies the number of SNMP managers Any value between 1 and 10 can be specified This number can be con...

Page 494: ...TSU LIMITED P2X0 1030 09ENZ0 494 The following example sets an SNMP community that is used only for traps CLI set community profile community community3 manager number 3 view The following example sets an SNMP community for which unlimited access is specified CLI set community profile community community4 manager number none view xview6 ...

Page 495: ...esult is the same as when community community4 is specified delete community profile community community_name manager number manager_numbers community This parameter specifies the SNMP community name of profiles to be deleted Only one community name can be specified at the same time manager number Optional This parameter specifies the manager number Any value between 1 and 10 can be specified This...

Page 496: ...e specified at the same time No Name Manager No MIB View 1 community1 1 2 3 4 5 6 7 8 9 10 view1 A B C D Manager list No IP address 1 192 168 0 10 2 17 20 56 101 3 10 0 0 1 4 172 101 235 221 5 192 168 0 11 6 144 72 48 100 7 192 168 100 1 8 192 168 100 2 9 192 168 100 3 10 192 168 100 4 E F A Community number B Community name C Manager number list D MIB view name E Manager number F Manager IP addre...

Page 497: ...s 2 17 20 56 101 6 144 72 48 100 The following example displays an SNMP community profile named community5 with 1 2 and 3 registered for the manager number that is only used to TRAP CLI show community profile community community5 No Name Manager No MIB View 5 community5 1 2 3 Manager list No IP address 1 192 168 0 10 2 17 20 56 101 3 10 0 0 1 The following example displays an SNMP community profil...

Page 498: ... SNMP version 3 default community Optional This parameter specifies the SNMP community name which can contain up to 32 alphanumeric characters A single command cannot define multiple traps This should be specified for SNMP version 1 or 2c This is not necessary for SNMP version 3 If double quotation marks are specified the associated community is removed from this trap setting user Optional This pa...

Page 499: ...Management set snmp trap ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 499 The following example sets the v3 SNMP trap corresponding to the SNMP user named user4 and SNMP manager number 3 CLI set snmp trap user user4 manager number 3 ...

Page 500: ...es the setting trap number The trap number can be confirmed using the show snmp trap command The following example deletes SNMP trap numbers 2 4 CLI show snmp trap Trap SNMP Manager IP Community User Port No Version Number Address Name Name Number 1 v1 1 192 168 100 250 community1 162 2 v2c 2 192 168 2 1 community2 162 3 v3 3 10 0 0 1 User1 162 4 v3 4 192 168 100 101 user_four 8162 5 v3 1 192 168 ...

Page 501: ...1 1 192 168 100 250 community1 User1 162 A B C D E F G A Number of the entered SNMP traps B SNMP version v1 v2c v3 C Manager number D IP Address E SNMP community name This is not displayed if the version is not v1 or v2c F SNMP user name This is not displayed if the version is v1 or v2c G Trap sending port number The following example displays a list of all the defined SNMP trap CLI show snmp trap...

Page 502: ...No parameters Example s test snmp trap The following example sends the SNMP trap for testing CLI test snmp trap The following example sends the SNMP trap to the SNMP Managers CLI show snmp trap Trap SNMP Manager IP Community User Port No Version Number Address Name Name Number 1 v1 1 192 168 100 250 community1 162 2 v2c 2 192 168 2 1 community2 162 3 v3 3 10 0 0 1 User1 162 4 v3 4 192 168 100 101 ...

Page 503: ...andard notation a base 256 d d d d string IPv6 address format or a fully qualified domain name Example server 192 168 1 20 Example server fd80 abd0 223 ad Example server foo bar user This parameter specifies the user account name for access to the FTP server This command displays an FTP server password prompt server view Optional This parameter specifies whether a file defined for use by ServerVie...

Page 504: ...ions which begin with a percent character are replaced by their corresponding value at the time of execution If other conversion strings are specified this command terminates abnormally with an error message s Serial number of the system Example MIB s mib bin MIB123456789012 mib bin d Current date Example MIB d mib bin MIB20080819 mib bin t Current time Example MIB t mib bin MIB144855 mib bin Perc...

Page 505: ...m Settings and Display 4 3 Network Management ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 505 4 3 3 E mail Notification This section explains the commands related to setting up e mail notification ...

Page 506: ...d or not If this parameter is omitted the status is not changed The initial value is disabled All necessary parameters to send E mail must be specified when enabling this parameter enable E mail notification is enabled disable E mail notification is disabled default port Optional This parameter specifies the Ethernet port to connect to an SMTP Server If omitted the existing setting is not changed ...

Page 507: ...g AUTH SMTP authentication This command displays a password prompt When authentication none is specified this parameter is unnecessary If omitted the existing setting is not changed from Optional This parameter specifies the from address field of E mail sent from the system If omitted the existing setting is not changed to1 to2 to3 to4 to5 Optional This parameter specifies up to 5 e mail addresses...

Page 508: ...clude a double quotation mark precede it by the back slash character Back slash characters are not include in the word count Example text1 abc def ghi 11 letters Result of this example abc def ghi retry count Optional This parameter specifies the number of retries that are performed when an e mail fails to send Specify 0 or 1 for the retry count If omitted the existing setting is not changed The d...

Page 509: ...ail is 64KB send log Optional This parameter is only available for the ETERNUS DX Disk storage system that does not have the REMCS support function If this parameter is specified for an ETERNUS DX Disk storage system that has the REMCS support function this command terminates This parameter specifies whether the E mail log notification function is enabled or not If omitted the existing setting is ...

Page 510: ...oo2 bar2 and the e mail receiver address is foo bar The fixed message is the following test line 1 test line 2 CLI set email notification send enable port maintenance server foo1 bar1 authentication cram md5 user profile1 from foo2 bar2 to1 foo bar text count 2 text1 test line 1 text2 test line 2 Password Confirm Password The following example sets up the parameters of the SMTP server The Ethernet...

Page 511: ...eters of E mail notification functions Syntax Parameter No parameters Output show email notification Send E Mail Enable A Port MNT B SMTP Server foo1 bar1 C SMTP Port No 25 D Authentication Auto E User Name profile1 F From foo2 bar2 G To1 foo1 bar1 H Text1 Hello I Retry Count 1 J Retry Interval sec 4 K Timeout sec 30 L Partial mode Enable M Partial size KB 64 N Send Log Enable O I O Module Log Ena...

Page 512: ...tial size KB O E mail log send mode It displays only the models that do not support REMCS P I O module log send mode It displays only the models that do not support REMCS Q Customer information send mode It displays only the models that do not support REMCS The following example displays the parameters related to E mail notification setup CLI show email notification Send E Mail Enable Port MNT SMT...

Page 513: ...ERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 513 test email This command sends an E mail from the system for testing Syntax Parameter No parameters Example s test email The following example tests whether the e mail can correctly be sent or not CLI test email ...

Page 514: ...ent Notification There are three categories of events that can occur Error Warning and Information When an event occurs a notification can be sent via E mail via SNMP by returning a SCSI sense to the host or by recording a syslog to syslog server This section explains the commands related to assigning what notifications are sent when various events occur ...

Page 515: ...complete redundant copy e complete rebuild e bad data e pinned data e not ready e remote path e halt path e halt overload e halt other e tp pool ratio e redundant e copy session error e sed network error w parts warning w disk warning w temperature warning w battery life i recovery module i temperature restoration i user logon logoff i operate raid group i add release hot spare i operate volume i ...

Page 516: ...the notice method e temperature error When the sensor detects an error level temperature error level events are notified Host sense SNMP E mail and syslog may be specified as the notice method e battery life When battery life expires error level events are notified Host sense SNMP E mail and syslog may be specified as the notice method only for the ETERNUS DX410 S2 DX440 S2 and ETERNUS DX8100 S2 D...

Page 517: ...pecified e sed network error When network connection errors occur with the key server error level events are notified SNMP E mail REMCS syslog and AIS Connect may be specified as the notice method e copy session error When an error occurs for a copy session or an abnormal copy session disappears error level events are notified SNMP E mail REMCS and syslog may be specified as the notice method w pa...

Page 518: ... the notice method i sdp policy level1 When the snap data pool usage reaches the Error level of the Advanced Copy policy information level events are notified SNMP E mail and syslog may be specified as the notice method i sdp policy level2 When the snap data pool usage reaches the Warning level of the Advanced Copy policy information level events are notified SNMP E mail and syslog may be specifie...

Page 519: ...omma This parameter cannot be specified in conjunction with the preset function Example method email snmp Specify E mail and SNMP email E mail snmp SNMP trap host Host sense remcs REMCS remote support syslog syslog ais AIS Connect suppression This parameter specifies the suppression mode It sets whether the specified event level and notice method are notified This parameter cannot be specified in ...

Page 520: ... not notify Do not notify Do not notify Host Login Over Do not notify Do not notify Do not notify Do not notify The following example sets the remote service default CLI set event notification preset remcs default CLI show event notification Severity Error Level E mail SNMP Host REMCS Syslog AIS Connect Parts Error Notify Notify Notify OPMSG Do not notify Notify Disk Error Notify HS 0 Notify HS 0 ...

Page 521: ...tification The notification method is E mail All events with Warning level are notified CLI set event notification severity warning method email suppression disable The following example sets up the parameters used for event notification The notification methods are Email and SNMP trap All events with Warning level or Error level are notified CLI set event notification severity error warning metho...

Page 522: ...ify Notify A B C D E F Disk Error Notify HS 0 Notify HS 0 Notify HS 0 OPMSG Do not notify Notify HS 0 G H A It indicates whether it is notified by E mail or not B It indicates whether it is notified by SNMP trap or not C It indicates whether it is notified by Host sense or not Also it means host sense as OPMSG D It indicates whether it is notified by REMCS or not E It indicates whether it is notif...

Page 523: ...fy Notify Do not notify Notify SED Network Error Notify Notify Do not notify Do not notify Notify Severity Warning Level E mail SNMP Host REMCS Syslog Parts Warning Notify Notify Notify Do not notify Notify Disk Warning Notify Notify Notify Do not notify Notify Temperature Warning Notify Notify Notify Do not notify Notify Battery life Warning Notify Notify Notify Do not notify Notify Severity Info...

Page 524: ...nged enable Warning display suppression is set for the components other than drives disable Warning display suppression is canceled for the components other than drives disk error This parameter is specified to suppress the error display for the drives on the LCD display Optional If omitted the setting is not changed enable Error display suppression is set for the drives The error display is suppr...

Page 525: ... Management set lcd suppress ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 525 Example s The following example sets up LCD suppression CLI set lcd suppress parts error enable parts warning enable disk error enable disk warning enable ...

Page 526: ...D Display Displayed Suppress Not displayed B It shows whether warning display for the components other than drives is displayed on the LCD Display Displayed Suppress Not displayed C It shows whether error display for the drives is displayed on the LCD Display Displayed Suppress Not displayed regardless of the number of hot spares left Display HS 0 Not displayed when hot spares are left D It shows ...

Page 527: ...unction System Settings and Display 4 3 Network Management ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 527 4 3 5 SMI S This section explains the commands relating to the SMI S function ...

Page 528: ...ample s set smi s function enable disable function Optional This parameter specifies whether all SMI S functions are enabled or not The initial value is disabled If omitted the existing setting is not changed To enable this parameter power cycle the system is required enable Each SMI S function is enabled disable Each SMI S function is disabled default The following example disables all the SMI S ...

Page 529: ...tions are enabled or disabled Syntax Parameter No parameters Output Example s show smi s Current Enable A After the next power cycle Enable B A It shows whether all of the SMI S functions are currently enabled B It shows whether all of the SMI S functions will be enabled after the next power cycle The following example displays the SMI S functions CLI show smi s S Current Enable After the next pow...

Page 530: ...istering a certificate that is signed by the certificate provider using CLI are as follows Procedure 1 Generate and export Certificate Signing Request CSR Use the create ssl certificate request command to generate and export a CSR for a signed certificate from the certificate provider This command generates and exports a CSR and a server key The server key should be hidden from other keys 2 Send C...

Page 531: ...the created public key file into IETF format 3 Register the public key in the ETERNUS DX Disk storage system 4 Check that CLI is available in the ETERNUS DX Disk storage system by using the public key authentication 5 Execute a CLI command using a here document in the SSH client End of procedure Settings state when ships from factory No Certificate Generate and export CSR 1 Send CSR to provider Re...

Page 532: ...68 0 101 Escape character is ETERNUS login is required 2011 11 11 11 11 11 Login foo Password CLI import ssh public key server 192 168 0 100 port maintenance user foo filename identity pub ietf account name foo Password importing identity pub ietf from 192 168 0 100 CLI exit rm identity pub ietf ssh foo 192 168 0 101 CLI exit echo show status ssh foo 192 168 0 101 CLI show status Summary Status No...

Page 533: ...rver key Only one value can be specified If this parameter is omitted 2048 default value is used for the key length 1024 Key length is 1024bits 2048 Key length is 2048bits Default value 4096 Key length is 4096bits version1 Optional This parameter specifies whether to enable connections using SSH Version 1 If this parameter is omitted it is handled as if enable is specified If connection via SSH Ve...

Page 534: ... address should be written in IPv4 standard notation a base 256 d d d d string or IPv6 address format The domain name should be written in full domain notation FQDN Only one value should be specified for this parameter Example foo var 192 168 1 1 2001 1b 430 db0 Abbreviated notations are recommended when inputting an IPv6 address This is because some browsers support only abbreviated notations sub...

Page 535: ...US CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 535 Example s The following example renews and registers the SSL server certificate CLI create ssl certificate key length 2048 common name eternus example com subject alt name eter nus example com eternusmnt example com 172 16 1 11 ...

Page 536: ...ation name organization_name organization unit name organization_unit_name common name common_name subject alt name altname1 alitname2 indicator enable disable port This parameter specifies which Ethernet port is used to connect to the FTP server For details refer to 1 11 Note for Specifying FTP Server page 31 maintenance MNT port remote RMT port fst FST port ETERNUS DX410 S2 DX440 S2 only server ...

Page 537: ...csr d Current date Example server_ d csr server_20100316 csr March 16 2010 t Current time Example server_ t csr server_123456 csr 12 34 56 Percent character Example server csr server csr key filename Optional This parameter specifies the filename to store the key file If omitted server key default file is used If the same filename already exists it is overwritten The following conversion specifica...

Page 538: ...ameter specifies an IP address or domain name that accesses HTTPS for the MNT port or the RMT port The IP address should be written in IPv4 standard notation a base 256 d d d d string or IPv6 address format The domain name should be written in full domain notation FQDN Only one parameter can be specified Example foo var 192 168 1 1 2001 1b 430 db0 subject alt name Optional This parameter specifies...

Page 539: ...generates and exports the CSR and the server key CLI export ssl certificate request port maintenance server ftp example com user tornado key length 2048 country name JP state province name Nagano locality name Nagano organization name FJL organiza tion unit name N ORCA common name eternus0001 example com Password exporting server csr to ftp example com Password exporting server key to ftp example ...

Page 540: ...ion a base 256 d d d d string format IPv6 address format or a fully qualified domain name FQDN Example server 192 168 1 20 Example server fd80 abd0 223 ad Example server foo bar user This parameter specifies a user account name for access to the FTP server This command displays an FTP server password prompt cert filename Optional This parameter specifies the filename to load the certificate file I...

Page 541: ... which is available for models in regions other than EMEA AIS Connect is not available in Japanese models This section explains the commands to set up the AIS Connect function AIS Connect environment AIS Connect environment display AIS Connect server AIS Connect remote session AIS Connect test transmission AIS Connect manual log transmission AIS Connect test event notification When performing the ...

Page 542: ...e AIS Con nect server This parameter cannot be specified when the AIS Connect function is disabled If omitted the existing setting is not changed maintenance MNT port remote RMT port send log Optional This parameter specifies whether to automatically collect logs and send them to the AIS Connect server when a failure Error Warning occurs This parameter cannot be specified when the AIS Connect func...

Page 543: ...ions can be specified If omitted the existing setting is not changed Example proxy server 192 168 1 20 Example proxy server foo bar proxy port number Optional This parameter specifies the proxy server port number Specify the port number within 1 to 5 digits The port number cannot be set above 65535 This parameter cannot be specified when the AIS Connect function is disabled or the proxy server is ...

Page 544: ... HERZEGOWINA 72 BOTSWANA 74 BOUVET ISLAND 76 BRAZIL 86 BRITISH INDIAN OCEAN TERRITORY 96 BRUNEI DARUSSALAM 100 BULGARIA 854 BURKINA FASO 108 BURUNDI 116 CAMBODIA 120 CAMEROON 124 CANADA 132 CAPE VERDE 136 CAYMAN ISLANDS 140 CENTRAL AFRICAN REPUBLIC 148 CHAD 152 CHILE 156 CHINA 162 CHRISTMAS ISLAND 166 COCOS VALUES KEELING ISLANDS 170 COLOMBIA 174 COMOROS 178 CONGO 184 COOK ISLANDS 188 COSTA RICA 3...

Page 545: ...17 KYRGYZSTAN 418 LAO PEOPLES DEMOCRATIC REPUBLIC 428 LATVIA 422 LEBANON 426 LESOTHO 430 LIBERIA 434 LIBYAN ARAB JAMAHIRIYA 438 LIECHTENSTEIN 440 LITHUANIA 442 LUXEMBOURG 446 MACAU 807 MACEDONIA THE FORMER YUGOSLAV REPUBLIC OF 450 MADAGASCAR 454 MALAWI 458 MALAYSIA 462 MALDIVES 466 MALI 470 MALTA 584 MARSHALL ISLANDS 474 MARTINIQUE 478 MAURITANIA 480 MAURITIUS 175 MAYOTTE 484 MEXICO 583 MICRONESIA...

Page 546: ...239 SOUTH GEORGIA AND THE SOUTH SANDWICH ISLANDS 724 SPAIN 144 SRI LANKA 654 ST HELENA 666 ST PIERRE AND MIQUELON 736 SUDAN 740 SURINAME 744 SVALBARD AND JAN MAYEN ISLANDS 748 SWAZILAND 752 SWEDEN 756 SWITZERLAND 760 SYRIAN ARAB REPUBLIC 158 TAIWAN PROVINCE OF CHINA 762 TAJIKISTAN 834 TANZANIA UNITED REPUBLIC OF 764 THAILAND 768 TOGO 772 TOKELAU 776 TONGA 780 TRINIDAD AND TOBAGO 788 TUNISIA 792 TU...

Page 547: ... ais connect AIS Connect Function Enable A Port MNT B Send Log Auto Enable C Country Of Installation 392 JAPAN D Service Contract Responsibility 392 JAPAN E SSL Server Certification Enable F Proxy Server foo bar G Proxy Port Number 123 H Proxy Type HTTP I Proxy User Name User1 J Remote Session Permit K Remote Session Timeout hour 3 L Trusted Root Certification Authorities Issuer Name Fujitsu Certi...

Page 548: ... of communication with the proxy server HTTP SOCKS If it is not set a hyphen is dis played J It indicates the user name for proxy authentication K It indicates whether a remote session from the AIS Connect server to the ETERNUS DX Disk storage system is allowed L It indicates the timeout interval for remote sessions A number between 1 to 24 or Unlimited is displayed M Root certification issuer N S...

Page 549: ...option the setting is automatically reversed if the AIS Connect server does not request remote sessions within the period that is specified for the timeout option permit Connections for remote sessions are permitted forbid Connections for remote sessions are not permitted timeout Optional but must be specified when permit is specified for the session parameter This parameter specifies the idle tim...

Page 550: ...I User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 550 test ais connect This command checks the connections with the AIS Connect server Syntax Parameter No parameters Example s test ais connect The following example checks the connection with the AIS Connect server CLI test ais connect ...

Page 551: ...er s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 551 send ais connect log This command is used to manually send logs to the AIS Connect server Syntax Parameter No parameters Example s send ais connect log The following example manually sends logs to the AIS Connect server CLI send ais connect log ...

Page 552: ...15 FUJITSU LIMITED P2X0 1030 09ENZ0 552 test ais connect event notification This command is used to test an event notification to the AIS Connect server Syntax Parameter No parameters Example s test ais connect event notification The following example tests an event notification to the AIS Connect server CLI test ais connect event notification ...

Page 553: ...ameter specifies the FTP server name in which the certificate file is to be stored The server name format is IPv4 standard notation as a string in the base 256 notation d d d d IPv6 address format or a fully qualified domain name FQDN Example server 192 168 1 20 Example server fd80 abd0 223 ad Example server foo bar user This parameter specifies the user name that is to be used to access the FTP s...

Page 554: ...elated to the following miscellaneous functions The main functions are as follows Date and time NTP ETERNUS DX Disk Storage System Name Box ID Power Synchronization Syslog Server Settings Shutdown Restart System 4 4 1 Date Time and NTP This section explains the commands related to setting the date and time of the system The system also supports time correction using the Network Time Protocol NTP ...

Page 555: ... is the minute 00 59 and ss is the second 00 59 If omitted the existing setting is not changed timezone Optional This parameter specifies the time difference from Greenwich Mean Time GMT The selectable preset numbers are shown below If omitted the existing setting is not changed 0 Eniwetok Kwajalein 12 00 1 Samoa 11 00 2 Honolulu 10 00 3 Alaska 9 00 4 Los Angels San Francisco San Diego 8 00 5 Ariz...

Page 556: ... changed There are two formats One format is MMDDhh MM is the starting month number 01 12 DD is the starting day number 01 31 and hh is the starting hour in 24 hour time 00 23 The other format is MM 1st 2nd 3rd 4th last sun mon tue wed thu fri sat hh MM is the starting month number 01 12 both 1st 2nd 3rd 4th last and sun mon tue wed thu fri sat are pairs and means the starting day and the starting...

Page 557: ...e following example sets the system date to 12 30 PM on January 1 2009 in the Honolulu time zone GMT 10 00 DST is set from 1 00 AM on the last Sunday of March to 1 00 AM on the last Sunday of October CLI set date time 20090101123000 timezone 2 dst enable from 03 last sun 01 to 10 last sun 01 The following example sets the system date to 12 30 PM on January 1 2009 DST is set from 2 00 AM on March 1...

Page 558: ... 2 00 AM on June 1 to 2 00 AM on September 30 2008 01 01 23 55 00 GMT 01 00 Paris Madrid Stockholm date time timezone dst DST ON 03 last Sun 02 00 10 last Sun 02 00 dst from 2 00 AM on March last Saturday to 2 00 on October last Saturday The following example displays the system date and time CLI show date 2008 10 01 10 59 59 GMT 09 00 Tokyo Osaka Kyoto Fukuoka Sapporo DST OFF CLI show date 2008 1...

Page 559: ...ified domain name The types of IPv6 addresses that can be specified are global addresses including 6to4 addresses link local addresses and unique local addresses If omitted the existing setting is not changed Example server 192 168 1 20 Example server fd80 abd0 223 ad Example server foo bar port Optional This parameter specifies the Ethernet port to connect to the NTP Server If omitted the existin...

Page 560: ...pserver com NTP Server name NTP LAN Port MNT Ethernet port to connect to NTP server Access Status 2008 02 21 08 30 00 succeeded SYNC Result of synchronization The following example displays the NTP configuration CLI show ntp NTP Enable NTP Server 10 1 1 100 NTP LAN Port RMT Access Status 2008 02 21 08 30 00 succeeded SYNC CLI show ntp NTP Enable NTP Server fd80 abd0 223 ad NTP LAN Port RMT Access ...

Page 561: ... and Display 4 4 Miscellaneous ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 561 4 4 2 ETERNUS DX Disk Storage System Name This section explains the commands used to set the ETERNUS DX Disk storage system name ...

Page 562: ...not changed installation site Optional This parameter specifies the installation site name up to 50 letters Permitted characters are described in 1 2 2 Keywords and Parameters page 19 If omitted the existing setting is not changed contact Optional This parameter specifies the administrator address up to 50 characters Permitted characters are described in 1 2 2 Keywords and Parameters page 19 If om...

Page 563: ... Syntax Parameter No parameters Output Example s show storage system name CLI show storage system name Name E2000 Series name of the system Installation Site FJ Installation site Contact xxx xxx xxxx Contact address Description admin machine Description of the ETERNUS DX Disk storage system The following example displays the ETERNUS DX Disk storage system name CLI show storage system name Name DXL...

Page 564: ... FUJITSU LIMITED P2X0 1030 09ENZ0 564 4 4 3 Encryption Mode This chapter explains the commands related to encryption mode functions Enabling encryption mode makes the encryption mode functions that are performed by a CM available Encryption related functions may not be available for some user environments ...

Page 565: ...setting When switching the encryption mode from disabled to enabled this operation is not required Syntax Parameter Example s Encryption related functions may not be available for some user environments set encryption mode fujitsu aes disable mode This parameter specifies encryption mode fujitsu Encryption mode is enabled Fujitsu aes Encryption mode is enabled AES disable Encryption mode is disabl...

Page 566: ...he encryption mode Syntax Parameter No parameters Output Example s Encryption related functions may not be available for some user environments show encryption Encryption Mode Fujitsu A A Encryption mode The following example displays whether the encryption mode is enabled or disabled CLI show encryption Encryption Mode Fujitsu CLI show encryption Encryption Mode AES CLI show encryption Encryption...

Page 567: ...er 4 Function System Settings and Display 4 4 Miscellaneous ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 567 4 4 4 Box ID This section explains the commands related to the Box ID ...

Page 568: ...ial number and additional fixed characters of the system are set as the default for the Box ID Syntax Parameter Example s set boxid id box_id id This parameter specifies a Box ID Up to 40 alphanumeric characters spaces and hash marks can be specified Each Box ID must be unique All alphabetic characters are handled as uppercase The pound key characters are automatically appended when the input char...

Page 569: ...ht 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 569 show boxid This command displays the registered Box ID Syntax Parameter No parameters Output Example s show boxid Box ID 00E2000 ET06F21AUABCPJ000000 A A Box ID The following example displays the registered Box ID CLI show boxid Box ID 00E2000 ET06F21AUABCPJ000000 ...

Page 570: ... System Settings and Display 4 4 Miscellaneous ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 570 4 4 5 Power Synchronization This section explains the commands related to power synchronization ...

Page 571: ...2 DX90 S2 and ETERNUS DX410 S2 DX440 S2 0 Controller module 0 1 Controller module 1 all Both Service Controller 0 and Service Controller 1 none No connection If selected only auto power and resume power from the parameters that follow can be selected svc Optional This parameter specifies which service controller connects to the external sensor The connection method conforms to the RS 232C standard...

Page 572: ... must be specified at the same time power fail signal Optional This parameter specifies the signal polarity of the power outage signal which indicates that the power supply has failed If omitted the existing setting is not changed The initial value is set to positive This can be set when preset manual is specified This can only be set for ETERNUS DX80 S2 DX90 S2 positive Positive is set negative N...

Page 573: ...2X0 1030 09ENZ0 573 Example s The following example sets how the shutdown function interacts with the external sensor Both controller modules are selected the shutdown time is specified as 5 minutes and the input signal that signals power outage is specified as positive CLI set power synchronization cm all shutdown time 5 power fail signal positive ...

Page 574: ...nnected to the power synchronized device This item is displayed only for the ETERNUS DX80 S2 DX90 S2 and the ETERNUS DX410 S2 DX440 S2 D It shows whether the SVC 1 is connected to the power synchronized device This item is only displayed for the ETERNUS DX8700 S2 E The setting to turn the system power on when AC power is supplied F The setting to turn the system power on when AC power is supplied ...

Page 575: ... CLI show power synchronization Controller Module 0 Enable Controller Module 1 Disable Auto Power Enable Resume Power Disable Waiting Time to Shutdown 5 min Type Power Synchronized Unit Power Fail Signal Positive Low Battery Signal Negative UPS Shutdown Signal Negative UPS Shutdown Enable The following example displays the settings that control how the shutdown function interacts with the external...

Page 576: ...ns the commands that are related to the Self Encrypted Disk SED authentication settings There are two types of authentication keys for SEDs the common key that is stored in the ETERNUS DX Disk storage system and an SED authentication key that is managed by the key server Commands for setting the common key are explained in this section Note that if an SED authentication key is used the common key ...

Page 577: ...r Self Encrypted Disks SEDs SEDs are used to prevent the leakage of data in case a disk is stolen or lost Syntax Parameter Example s set sed authentication execution yes no execution This parameter sets the authentication key for SEDs yes The authentication key for SEDs is set no The authentication key for SEDs is not set default The following example sets the authentication key for an SED CLI set...

Page 578: ...rs Output Example s show sed authentication CLI show sed authentication SED authentication Registered A A It indicates whether the SED authentication key is registered The following example shows the sed authentication command when the SED authentication key is registered CLI show sed authentication SED authentication Registered The following example shows the sed authentication command when the S...

Page 579: ...a machine to send event notification message This section explains commands related to the sending settings for the server Set up the association with Syslog server s Display settings of the association with the system and Syslog server s Syslog server 1 Syslog server 2 Set up the association with Syslog server s Refer settings of the association with Syslog server s ETERNUS DX Disk storage system...

Page 580: ...nd uses message format based on RFC5424 server1 Optional This parameter specifies syslog server 1 Only one server can be specified The server name format should be IPv4 standard notation a base 256 d d d d string IPv6 address format or a fully qualified domain name FQDN The types of IPv6 addresses that can be specified are global addresses including 6to4 addresses link local addresses and unique l...

Page 581: ...ified are global addresses including 6to4 addresses link local addresses and unique local addresses Up to 63 alphanumeric characters can be specified If this parameter is omitted this setting is not changed Example server2 192 168 1 20 Example server2 fd80 abd0 223 ad Example server2 foo bar server2 port number Optional This parameter specifies syslog server 2 s UDP port number for the syslog prot...

Page 582: ...er 517 G Server2 Port RMT H A It shows whether syslog server 1 is enabled B FQDN or IP address IPv4 or IPv6 of the syslog server 1 C UDP port number of the syslog server 1 for the syslog protocol D It shows which port is used E It shows whether syslog server 2 is enabled F FQDN or IP address IPv4 or IPv6 of the syslog server 2 G UDP port number of the syslog server 2 for the syslog protocol H It s...

Page 583: ...eer or administrator and the response from the system Logs are sent to the server by using syslog pro tocols This section explains the following commands related to the audit log settings Setting up the audit log function Displaying the audit log function Syslog server ETERNUS DX Disk storage system System administrator Log in Log out Change settings Information such as the storage system name the...

Page 584: ...be specified when the audit log function is disabled disable Syslog server 1 is disabled rfc3164 Syslog server 1 is enabled and uses message format based on RFC3164 rfc5424 Syslog server 1 is enabled and uses message format based on RFC5424 server1 Optional This parameter specifies syslog server 1 Only one server can be specified The server name format should be IPv4 standard notation a base 256 d...

Page 585: ...s of IPv6 addresses that can be specified are global addresses including 6to4 addresses link local addresses and unique local addresses Up to 63 alphanumeric characters can be specified If omitted the existing setting is not changed This parameter cannot be specified when the audit log function is dis abled Example server2 192 168 1 20 Example server2 fd80 abd0 223 ad Example server2 foo bar serve...

Page 586: ...he audit log function is enabled B It indicates whether syslog server 1 is enabled C FQDN or IP address IPv4 or IPv6 of the syslog server 1 D UDP port number of the syslog server 1 for the syslog protocol E It indicates which port is used F It indicates whether syslog server 2 is enabled G FQDN or IP address IPv4 or IPv6 of the syslog server 2 H UDP port number of the syslog server 2 for the syslo...

Page 587: ...covery from key group blockage Summary of using CLI to perform key management server linkage function settings The steps involved in setting the key management server linkage function are provided below Procedure 1 Register the SED authentication key Use the set sed authentication command to register the SED authentication key After executing this command use the show sed authentication command to...

Page 588: ...he key server status Use the show sed key groups command to check the key server status 9 Set the key group for a RAID group Use the set raid group command to enable the key management server linkage function for a RAID group End of procedure Use the create sed key group command to change a key group Use the delete sed key group command to delete a key group If no SED authentication key is registe...

Page 589: ...ponds to the machine ID in the key server Syntax Parameter Example s set sed key machine name machine name machine_name machine name This parameter specifies the key management machine name Up to 48 alphanumeric charac ters and underscores _ can be specified Only an alphabetical character can be specified as the first letter Specify consecutive double quotations to disable the specified key manage...

Page 590: ...e This command displays the key management machine name for connecting with the key server Syntax Parameter No parameters Output Example s show sed key machine name Key Machine Name A0E2000000000_ET06F21AUABCPJ000000 A A Key management machine name The following example displays the key management machine name CLI show sed key machine name Key Machine Name A0E2000000000_ET06F21AUABCPJ000000 ...

Page 591: ... d d d string IPv6 address format or a fully qualified domain name FQDN Up to 63 alphanumeric characters can be specified Specify consecutive double quotations to disable the specified server ID If omitted the existing setting is not changed Example server 192 168 1 20 Example server fd80 abd0 223 ad Example server foo bar port number Optional This parameter specifies the port number of the key se...

Page 592: ... parameter is omitted all of the server information is displayed Server ID 1 A Server 10 21 134 198 B Port Number 5696 C Port RMT D Server ID 2 Server Port Number 5696 Port MNT A Key server ID B FQDN or IP address IPv4 or IPv6 of the key server C Port number of the key server D It shows which LAN port is used The following example displays the key server information CLI show sed key servers Server...

Page 593: ...rver This parameter specifies the FTP server name in which the certificate file is to be stored The server name format is IPv4 standard notation as a string in the base 256 notation d d d d IPv6 address format or a fully qualified domain name FQDN Example server 192 168 1 20 Example server fd80 abd0 223 ad Example server foo bar user This parameter specifies the user name that is to be used to acc...

Page 594: ...be performed when communication with the key server is not available during a disk failure or disk maintenance work in a RAID group that uses the key group low Rebuild or maintenance is performed using the common key when communica tion with the key server is not available during a disk failure or disk maintenance work in a RAID group that uses the key group recovery mode Optional This parameter s...

Page 595: ...er ID for the slave server 1 or 2 can be specified When the slave server is not used specify consecutive double quotations If omitted the slave server is not set Use the same setting as the slave server that is set in the key server The following example sets up the key group CLI create sed key group name key group1 machine group name machine_group1 security level high recovery mode auto period 6 ...

Page 596: ...ed when communication with the key server is not available during a disk failure or disk maintenance work in a RAID group that uses the key group low Rebuild or maintenance is performed using the common key when communica tion with the key server is not available during a disk failure or disk maintenance work in a RAID group that uses the key group recovery mode Optional This parameter specifies w...

Page 597: ...D for the slave server 1 or 2 can be specified When the slave server is not used specify consecutive double quotations If omitted the existing setting is not changed Use the same setting as the slave server that is set in the key server The following example modifies the key group CLI set sed key group name key group2 machine group name machine_group2 security level low recovery mode manual period...

Page 598: ...d key group ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 598 delete sed key group This command deletes the key group Syntax Parameter No parameters Example s delete sed key group The following example deletes the key group CLI delete sed key group ...

Page 599: ...ver ID 1 Normal H I Master Server 10 21 134 198 J Slave Server ID 2 Normal K L Slave Server 10 21 134 199 M Server Certificate Information Issuer Name Fujitsu Certification Authority N Subject Name Key Management Server O Valid From 2012 08 17 13 04 47 P Valid To 2015 08 17 13 04 47 Q Serial Number 602199653074063 R A Key group name B Valid period of the key being used If the key server is inacces...

Page 600: ...urity Level High Recovery Mode Auto Period 7 Master Server ID 1 Normal Master Server 10 21 134 198 Slave Server ID 2 Normal Slave Server 10 21 134 199 Server Certificate Information Issuer Name Fujitsu Certification Authority Subject Name Key Management Server Valid From 2012 08 17 13 04 47 Valid To 2015 08 17 13 04 47 Serial Number 602199653074063 The following example shows when a key group is r...

Page 601: ...y This command updates the key for the key group Syntax Parameter Example s change sed key mode reuse delete mode This parameter specifies the update mode reuse The previously used key is reusable after being switched delete The previously used key is not reusable after being switched The following example updates the key for the key group CLI change sed key mode reuse ...

Page 602: ...up ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 602 recover sed key group This command recovers a blocked key group Syntax Parameter No parameters Example s recover sed key group The following example recovers the blocked key group CLI recover sed key group ...

Page 603: ...tem Settings and Display 4 4 Miscellaneous ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 603 4 4 10 Shutdown Restart System This section explains the commands related to system shutdown or restart ...

Page 604: ...restarted regardless of the power synchronization setting When power synchronization is enabled and the ETERNUS Disk storage system is shut down by this command the ETERNUS Disk storage system may automatically restart according to the power control process of the server shutdown mode off reboot mode This parameter specifies the shutdown mode off Power off the system reboot Power OFF and power ON ...

Page 605: ...ction explains performance related commands 5 1 1 Performance Information These functions display the performance information that is collected and stored by the system Information is collected for each volume each host interface port each disk and each controller module Collection must be enabled before performance information can be displayed This section explains the commands to collect and dis...

Page 606: ...150 180 210 240 270 300 interval Optional This parameter specifies the update interval for performance information A unit is second If omitted the default value 30 seconds is used 30 Updated every 30 seconds default 60 Updated every 60 seconds 90 Updated every 90 seconds 120 Updated every 120 seconds 150 Updated every 150 seconds 180 Updated every 180 seconds 210 Updated every 210 seconds 240 Upda...

Page 607: ...ser s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 607 stop performance This command stops the collection of performance information Syntax Parameter No parameters Example s stop performance The following example stops the collection of performance information CLI stop performance ...

Page 608: ...l This parameter specifies the type of performance information If omitted the performance collection status is displayed host io Host I O statistics for each volume advanced copy Advanced copy statistics for each volume disks Statistics for each disk cm Statistics for controller module port Statistics for host interface port volume number or volume name Optional This parameter specifies the volume...

Page 609: ...ntroller module 1 CPU 0 cm1cpu1 Controller module 1 CPU 1 cm2cpu0 Controller module 2 CPU 0 cm2cpu1 Controller module 2 CPU 1 cm3cpu0 Controller module 3 CPU 0 cm3cpu1 Controller module 3 CPU 1 cm4cpu0 Controller module 4 CPU 0 cm4cpu1 Controller module 4 CPU 1 cm5cpu0 Controller module 5 CPU 0 cm5cpu1 Controller module 5 CPU 1 cm6cpu0 Controller module 6 CPU 0 cm6cpu1 Controller module 6 CPU 1 cm...

Page 610: ...te Prefetch 1 VOL001 6621 5192 589 379 17055 12056 41 37 36 2 VOL002 7791 6608 613 292 12148 11045 41 37 36 A B C D E F G H I J K A Volume number B Volume name C Read IOPS D Write IOPS E Read Throughput F Write Throughput G Read Response Time H Write Response Time I Read Cache Hit J Write Cache Hit K Prefetch Cache Hit When the Advanced Copy performance information type is specified Volume IOPS IO...

Page 611: ...y residual quantity unit MB When the controller module performance information type is selected while the I O Offloading function is enabled ETERNUS DX8700 S2 Location Busy Rate ROE 0 Busy Rate ROE 1 Busy Rate Copy Residual Quantity MB CM 0 CPU 0 52 52 30 55191552 CM 1 CPU 1 1 2 0 0 A B C D E A Controller module number B Controller module busy rate C Controller module ROE busy rate ROE 0 D Control...

Page 612: ...C Received IOPS D Transmitted Throughput E Received Throughput The following example displays the status of performance information collection CLI show performance Status ON Interval 30sec The following example displays the performance information when the host I O performance information type is specified CLI show performance type host io Volume IOPS IOPS Throughput MB s Response Time msec Cache ...

Page 613: ...y Rate CE Disk 0 67 CE Disk 1 66 The following example displays the performance information when the drive performance information type is specified for disk 0 in the CE CLI show performance type disks disks 000 Location Busy Rate CE Disk 0 67 The following example displays the performance information when the controller module performance information type is specified for both CMs ETERNUS DX410 S...

Page 614: ...2 CM 4 CPU 1 30 40 10 32001532 CM 5 CPU 0 66 70 30 55191552 CM 5 CPU 1 30 40 10 32001532 CM 6 CPU 0 66 70 30 55191552 CM 6 CPU 1 30 40 10 32001532 CM 7 CPU 0 66 70 30 55191552 CM 7 CPU 1 30 40 10 32001532 For FC and iSCSI the following example displays the performance information for the host interface ports CLI show performance type port Location IOPS IOPS Throughput MB s Read Write Read Write CM...

Page 615: ...a mix of both RA and CA modes CLI show performance type port CA Port Information Location IOPS IOPS Throughput MB s Read Write Read Write CM 0 CA 0 Port 0 6621 5192 589 379 CM 0 CA 0 Port 1 7791 6608 613 292 CM 0 CA 0 Port 3 6621 5192 589 379 CM 1 CA 0 Port 3 7791 6608 613 292 RA Port Information Location IOPS IOPS Throughput MB s Transmitted Received Transmitted Received CM 0 CA 0 Port 2 6621 519...

Page 616: ... Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 616 5 1 2 Performance Tuning Parameters This section explains the commands related to performance tuning parameters The following items can be tuned RAID group performance Cache performance Disk performance Cache size for Bind in Cache ...

Page 617: ...t on the number of outstanding commands by a factor of two from the default rebuild priority Optional This parameter specifies the priority for Rebuild of the relevant RAID group The same priority is set to all of the RAID groups that are specified with the rg number parameter or the rg name parameter low Low Normal priority is given for rebuild copyback and redundant copy middle Middle Rebuild co...

Page 618: ...arameter include a RAID group that is configured with SSDs If omitted the existing setting is not changed The following example sets the performance tuning parameters for the RAID group named R1 10 is specified for DCMF 80 is specified for throttle and 1024 is specified for ordered cut CLI set raid tuning rg name R1 dcmf 10 disk tuning enable throttle 80 ordered cut 1024 The following example sets...

Page 619: ... RAID group number B RAID group name C RAID level D RAID group status E DCMF A multiplying factor which issues disk commands to disks F Rebuild Priority G It shows whether Disk Tuning is enabled H Ratio of command issues to disks I Interval for issuing the Ordered Queue command to disks The following example displays the performance tuning parameters of all the RAID groups CLI show raid tuning RAI...

Page 620: ...e Thin Provisioning Pool for the performance tuning parameter One or more Thin Provisioning Pools can be specified For details refer to 1 2 5 Thin Provisioning Pool Syntax page 20 fp Optional This parameter specifies the Force Pre fetch FP mode If this parameter is omitted the mode is not changed enable Force Pre fetch mode is enabled disable Force Pre fetch mode is disabled pl Optional This param...

Page 621: ...mory capacity that can be used by a volume If omitted then this parameter is not changed Thin Provisioning Pools cannot be specified If the Bind in Cache capacity is set in the ETERNUS Disk storage system this parameter cannot be used Volumes that are not LUN Concatenation Volumes and that are the following types can be specified Standard SDV SDPV MVV off No upper limit is set 32 5mb Up to 32 5MB ...

Page 622: ... Mode E Pre fetch Limit F Multi Write back Count Selectable range G Number of times data access Read I O is sequentially performed H Number of times data access Write I O is sequentially performed I Value of the parameter for determining data access Read I O sequentially J Value of the parameter for determining data access Write I O sequentially K Upper limit value for the cache memory capacity th...

Page 623: ...splay 5 2 Event Log Information ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 623 5 2 Event Log Information This section explains the commands for displaying information on events that have occurred in the system ...

Page 624: ...cted to information about events of the specified severity level Only one level can be specified at the same time If omitted all the events of the severity levels are displayed information Information level warning Warning level error Error level cm Optional This parameter specifies the controller module number Only events for the specified CM are displayed If omitted all the events of all CMs are...

Page 625: ...ation show events ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 625 Example s The following example displays the event information for Error level CLI show events level error 2008 01 01 12 00 05 Error P 01000000 Controller module 0 Fault ...

Page 626: ...NUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 626 delete events This command deletes all the events that have been recorded in the system Syntax Parameter No parameters Example s delete events The following example deletes all the event information CLI delete events ...

Page 627: ...intenance ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 627 5 3 Maintenance This chapter explains the commands related to maintenance 5 3 1 Hardware Maintenance This section explains the commands related hardware maintenance ...

Page 628: ...nect AC cables to both PSUs hot expansion type type_name type This parameter specifies the name of the component to be added Only one component can be specified at the same time host port Host interface port upgrading a single port model to two ports for the ETERNUS DX80 S2 DX90 S2 An additional host interface port license must be registered For details refer to Hot Expansion Procedure for Various...

Page 629: ...involved in increasing the number of usable host interface ports are as follows Procedure 1 Use the set host port license key xxxxxxxxxxxxxxxx command to register the host interface port expansion license The operand of the key parameter is the license key 2 Remove the covers of port 1 on CM XDB X 3 Attach SFPs to port 1 on CM XDB X 4 Use the hot expansion type host port command to define and inco...

Page 630: ...0 S2 the ETERNUS DX410 S2 DX440 S2 and the ETERNUS DX8100 S2 Syntax Parameter No parameters Output Example s show btu date Parts Status Replacement year month bbu0 btu ONLINE 2010 04 A B C D A Battery unit number B Battery unit status C Year of the replacement D Month of the replacement The following example displays the date of the battery replacement CLI show btu date Parts Status Replacement ye...

Page 631: ... Settings and Display 5 3 Maintenance ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 631 5 3 2 Remote Directory This section explains the commands related to displaying a directory in an FTP server ...

Page 632: ...ifying FTP Server page 31 maintenance MNT port remote RMT port server This parameter specifies the FTP server name to display a directory The server name format is IPv4 standard notation a base 256 d d d d string or a fully qualified domain name FQDN Example server 192 168 1 20 Example server foo bar user This parameter specifies the user name that can access the FTP server This command displays a...

Page 633: ...lowing example displays the file list of the directory named tmp on the server named ftp a com that is connected via the Maintenance Ethernet port The user name for the FTP server is profile1 CLI show remote dir port maintenance server ftp a com dir tmp user profile1 Password v10l10 0000 01 bin 2011 01 10 10 20 30 1048756 v10l10 0000 02 bin 2011 01 10 10 20 30 1048756 ...

Page 634: ...Settings and Display 5 3 Maintenance ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 634 5 3 3 Controller Firmware This section explains the commands related to the maintenance of controller firmware ...

Page 635: ...firmware version Version Date 1 V10L30 0000 2011 12 09 Next 2 V10L20 0000 2011 09 01 Current A B C A Controller firmware version B Created date C Status Current The currently running firmware Next The reserved controller firmware at the next booting Others are not displayed The following examples display the controller firmware version CLI show firmware version Version Date 1 V10L10 0000 2011 06 0...

Page 636: ...CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 636 5 3 4 Log Various incidents are recorded in the system logs component failures environment conditions user operations warning incidents etc This section explains the commands related to exporting logs ...

Page 637: ...FTP Server page 31 maintenance MNT port remote RMT port fst FST port not supported by the ETERNUS DX80 S2 DX90 S2 server This parameter specifies the name of the FTP server that will receive the logs The server name format is IPv4 standard notation a base 256 d d d d string or a fully qualified domain name FQDN Example server 192 168 1 20 Example server foo bar user This parameter specifies the us...

Page 638: ...d Note that both the starting time and ending time must be specified If these parameters are specified the last 24h parameter cannot be specified ending time Optional Log entries can be restricted to a specific time range This parameter specifies the ending time The format is YYYYMMDD hhmmss YYYY is the number of the year a four digit number MM is the number of the month 01 12 DD is the number of ...

Page 639: ... the logs enable Customer information is included in the logs disable Customer information is excluded from the logs indicator Optional This parameter specifies whether the progress indicator is displayed If omitted this function is enabled enable Progress indicator is displayed disable Progress indicator is not displayed The following example exports logs to the FTP server named ftp a com using t...

Page 640: ...d Display 5 3 Maintenance ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 640 5 3 5 Panic Dump The system stores a panic dump when crashing This section explains the commands related to exporting the panic dump ...

Page 641: ...ilename dump number dump_number divide no 4mb 1mb 640kb indicator enable disable port This parameter specifies which Ethernet port is used to connect to the FTP server For details refer to 1 11 Note for Specifying FTP Server page 31 maintenance MNT port remote RMT port fst FST port not supported by the ETERNUS DX80 S2 DX90 S2 server This parameter specifies the FTP server name which will store the...

Page 642: ...e s Serial number of the system Example tmp s log bin tmp 123456789012 log bin d Current date Example tmp d log bin tmp 20080819 log bin t Current time Example tmp t log bin tmp 144855 log bin Percent character Example tmp log bin tmp log bin dump number One or more panic dumps can be stored in the system They can be displayed by using the show panic dump command This parameter specifies the panic...

Page 643: ...nance server ftp a com user profile1 filename tmp dump dump number 1 Password Operator inputs password but it is hidden Panic Dump No 1 CM 0 2008 07 10 12 15 10 0x12345678 286331153 EXC Data Abort selected panic dump details in the same format as show panic dump command exporting tmp dump to ftp a com complete The following example is the same as above except that the progress indicator is not dis...

Page 644: ...10 0x12345678 286331153 EXC Data Abort 2 CM 1 2008 07 14 12 35 10 0x12345678 286331153 EXC Data Abort 3 CA 3 2009 01 23 12 34 10 0x12345678 134217728 EXC Data Abort A B C D E F A Panic dump number B Panic dump module name C Panic date D Panic code E Panic dump size unit byte F Messages The following example displays a list of the panic dumps CLI show panic dump No Module Panic Date Panic Code Data...

Page 645: ...ce ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 645 5 3 6 Configuration Information Configuration information can be stored externally in a file This section explains the commands related to manipulating configuration information ...

Page 646: ...e FTP server name that will store the configuration information The server name format is IPv4 standard notation a base 256 d d d d string or a fully qualified domain name FQDN Example server 192 168 1 20 Example server foo bar user This parameter specifies the user name that can access the FTP server This command displays a password prompt filename This parameter specifies configuration informati...

Page 647: ...ted this function is enabled enable Progress indicator is displayed disable Progress indicator is not displayed The following example exports the latest configuration information to the FTP server named ftp a com using the Maintenance Ethernet port The user name for the FTP server is profile1 and the filename is tmp config cfg CLI export config information port maintenance server ftp a com user pr...

Page 648: ...x Parameter No parameters Output Example s show config information Information Date Note Two Time Before One Time Before 2008 07 20 23 11 00 aabbccdd Latest 2008 07 22 15 26 45 A A Configuration date If the system has no configuration information a hyphen is displayed here The following example displays a list of the configuration information CLI show config information Information Date Note Two T...

Page 649: ...Settings and Display 5 3 Maintenance ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 649 5 3 7 Error Information This section explains the commands related to the error information of disks and ports ...

Page 650: ... I J K A An error Sign it shows there are some errors of both ports B Disk Number C Disk status D Disk Port Number E Media Error Count F Drive Error Count G Drive Recovered Error Count H SMART Event Count I I O Timeout Count J Link Error Count K Check Code Error Count The following example displays the disk error information CLI show disk error E Disk Status Port Media Drive Drive Recovered SMART ...

Page 651: ...ample s clear disk error disks disks disks Optional This parameter specifies the disks to clear the error information from One or more disks can be specified at the same time For details refer to 1 2 3 Disk Syntax page 19 If this parameter is omitted the error information for all the disks is cleared The following example clears the error information for all the disks CLI clear disks error The fol...

Page 652: ...es There are three ports for each expander module and four PHYs for each port For SAS there are also ports and PHYs for the host interfaces Syntax Parameter No parameters Output show port error CLI show port error Expander Port PHY Status Invalid Disparity Loss of Dword PHY Reset Dword Error Synchronization Problem FE EXP 0 Port 0 PHY 0 Link Up 1 0 0 1 A B C D E F G H A Expander Type B Port Number...

Page 653: ...ink Up 0 0 0 0 PHY 3 Link Up 0 0 0 0 Port 2 PHY 0 Link Up 0 0 0 0 PHY 1 Link Up 0 0 0 0 PHY 2 N A PHY 3 N A BE EXP 1 Port 0 PHY 0 Link Up 0 0 0 0 PHY 1 Link Up 0 0 0 0 PHY 2 N A PHY 3 N A Port 1 PHY 0 Link Up 0 0 0 0 PHY 1 Link Up 0 0 0 0 PHY 2 Link Up 0 0 0 0 PHY 3 Link Up 0 0 0 0 Port 2 PHY 0 Link Up 0 0 0 0 PHY 1 Link Up 0 0 0 0 PHY 2 N A PHY 3 N A DE 1 EXP 0 Port 0 PHY 0 Link Up 0 0 0 0 PHY 1 ...

Page 654: ... Up 0 0 0 0 Port 2 PHY 0 Link Up 0 0 0 0 PHY 1 Link Up 0 0 0 0 PHY 2 N A PHY 3 N A BRT 0 EXP 1 Port 0 PHY 0 Link Up 0 0 0 0 PHY 1 Link Up 0 0 0 0 PHY 2 N A PHY 3 N A Port 1 PHY 0 Link Up 0 0 0 0 PHY 1 Link Up 0 0 0 0 PHY 2 Link Up 0 0 0 0 PHY 3 Link Up 0 0 0 0 Port 2 PHY 0 Link Up 0 0 0 0 PHY 1 Link Up 0 0 0 0 PHY 2 N A PHY 3 N A DE 1 IOM 0 Port 0 PHY 0 Link Up 0 0 0 0 PHY 1 Link Up 0 0 0 0 PHY 2 ...

Page 655: ...gs and Display 5 3 Maintenance ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 655 5 3 8 Bad Data Information in Volumes This section explains the commands for resolving the bad data information of volumes ...

Page 656: ...r LBA LBA Count Error Type No Name 1 VOL001 Standard 0x0123456789ABCDEF 0xFEDCBA9876543210 contiguity A B C D E F A Volume number B Volume name C Volume type D Start offset LBA of the bad data E Number of LBAs of the bad data F Error type The following example displays bad data information for volume number 1 CLI show bad data info volume number 1 Volume Volume Type Error LBA LBA Count Error Type ...

Page 657: ...57 The following example displays all the volumes with bad data information CLI show bad data info Volume Volume Type Error LBA LBA Count Error Type No Name 1 VOL001 Standard 0x0123456789ABCDEF 0xFEDCBA9876543210 contiguity 3 VOL003 MVV 0x0000000089ABCDEF 0x0000000076543210 contiguity 10 VOL010 Standard 0x0000000076543210 0x0000000089ABCDEF dispersion ...

Page 658: ...TERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 658 5 4 Utility This chapter explains commands related to miscellaneous system utility functions 5 4 1 Diagnosis Utilities This section explains the commands related to system diagnosis ...

Page 659: ...ifiers to be displayed and can only be specified in conjunction with the type raid groups parameter One or more RAID groups can be specified at the same time For details refer to 1 2 8 RAID Group Syntax page 22 If omitted all the RAID groups are selected disks Optional This parameter specifies the disks to display more detailed diagnostic results of the disks and can only be specified in conjuncti...

Page 660: ...r and name Diagnosis Status Executing status Result Diagnosis result Details of the disk diagnosis Location Disk number Diagnosis Status Executing status Result Diagnosis result Progress Diagnosis progress Diagnosed Disk LBA Count Diagnosed LBA Total Disk LBA Count Total LBAs of the disks Error Information Hard Error Count Detected hard error count SMART Error Count Detected SMART count Compare Er...

Page 661: ... Detected recovered error in others target is SENSE 01 0300 and 01 1501 Recovered Error Details Head 0 7 Detected recovered error in the head 0 7 except SENSE 03 1100 and 01 1300 Other Error Count Detected recovered error in others target is SENSE 03 1100 and 01 1300 Details of the RAID diagnosis RAID Group Number RAID group number RAID Group Name RAID group name Recovery Mode Diagnosis mode ON Au...

Page 662: ...unts for restoration succeeded and restoration failed cases Bad Data Flag Error Bad data flag error counts for restoration succeeded and restoration failed cases Error Details Detailed errors in the case where restoration failed Volume Number The volume number in which errors occurred Volume Name The volume name in which errors occurred Status Recovering status Error status Medium Error CRC Error ...

Page 663: ...Mode ON RAID Group List RAID Group Diagnosis Result No Name Status 1 RLU000 Complete Normal 12 RLU002 Complete Normal 13 RLU003 Complete Normal 14 RLU004 Diagnosing Normal The following example displays the detailed results of the disk diagnosis CLI show diagnosis type disks disks 100 Location DE 1 Disk 0 Diagnosis Status Diagnosing Result Normal Progress 10 Diagnosed Disk LBA Count 0x000000000880...

Page 664: ...g Result Normal Progress 34 Diagnosed RAID Group LBA Count 0x0000000008803072 Total RAID Group LBA Count 0x0000000025182720 Succeeded in Restoration 0 Failed in Restoration 0 Error Information Error Succeeded Failed in Restoration Compare Error 0 0 Medium Error 0 1 CRC Error 0 0 Block ID Error 0 0 Bad Data Flag Error 0 0 Error Detail Information 1 1 Volume Number 1023 Volume Name VOL 001 Status Re...

Page 665: ...er 5 Information Settings and Display 5 4 Utility ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 665 5 4 2 LED This section explains the commands related to the control of the LEDs ...

Page 666: ...also be specified ce All components in the controller enclosure disk Only the specified disks svc0 Only SVC 0 Only for ETERNUS DX8700 S2 svc1 Only SVC 1 Only for ETERNUS DX8700 S2 opnl Only the operation panel Only for ETERNUS DX8700 S2 disks Optional This parameter specifies which disks LED are turned on or off Multiple disks can be specified at the same time For details refer to 1 2 3 Disk Synta...

Page 667: ...panel unit B LED status of the CM 0 This item is displayed only for the ETERNUS DX80 S2 DX90 S2 and ETERNUS DX410 S2 DX440 S2 C LED status of the CM 1 This item is displayed only for the ETERNUS DX80 S2 DX90 S2 and ETERNUS DX410 S2 DX440 S2 D LED status of the SVC 0 This item is displayed only for the ETERNUS DX8700 S2 E LED status of the SVC 1 This item is displayed only for the ETERNUS DX8700 S2...

Page 668: ...and Display 5 4 Utility ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 668 5 4 3 Other Notification This section explains the commands used for setting parameters regarding other event notification functions ...

Page 669: ... disable blink panel led Optional This parameter specifies whether the Panel FAULT LED will blink when the system is in warning status enable The Panel FAULT LED will blink disable The Panel FAULT LED will not blink redundant copy led Optional This parameter specifies whether the FAULT LED will turn on after the redundant copy is complete enable The Fault LED will turn on after the redundant copy ...

Page 670: ...d Syntax Parameter No parameters Output Example s show event parameters Blink Panel Fault LED Enable A Redundant Copy Fault LED Enable B A It shows whether the Panel Fault LED is blinked or not when the system status is warning B It shows whether the Fault LED lights up or not when the redundant copy is complete The following example displays the event parameters CLI show event parameters Blink Pa...

Page 671: ...n Settings and Display 5 4 Utility ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 671 5 4 4 Sub system Parameters This section explains the commands used to set and check the subsystem parameters ...

Page 672: ...e load balance is enabled incorrect logs may be recorded in the host enable Load balance control is enabled disable Load balance control is disabled reject inquiry Optional This parameter specifies whether an INQUIRY command that is issued from an unauthorized host is rejected Enable this parameter when VERITAS Volume Manager Dynamic Multi Pathing VxVM DMP is used If omitted the existing settings ...

Page 673: ...ckcode Enforcement mode is enabled disable The Checkcode Enforcement mode is disabled io offloading Optional This parameter specifies whether to enable I O Offloading I O Offloading performs a part of the I O processing on ROE and improves the maximum IOPS performance Rebooting the ETERNUS DX Disk storage system is required to enable the new configuration When the I O load is low I O Offloading ha...

Page 674: ...issued from an unauthorized host is accepted When an INQUIRY command is set to be not accepted the operation is the same as the response to an INQUIRY command with an Affinity Error C It indicates if the current setting of the Thin Provisioning Allocation mode is enabled D It indicates if the Checkcode Enhancement mode is enabled E It indicates if the I O Offloading is enabled for improving perfor...

Page 675: ...Settings and Display 5 4 Utility ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 675 5 4 5 Reservations This section explains the commands related to the persistent reservation status of the volumes ...

Page 676: ...Example s release reservation volume number volume_numbers volume name volume_names volume number or volume name This parameter specifies the volume identifiers to be released One or more volumes can be specified at the same time For details refer to 1 2 9 Volume Syntax page 22 The following example releases the volume named VOL001 that has been reserved by the host servers CLI release reservation...

Page 677: ...me name C Logical unit number associated with volume D When Host Affinity Mode is disabled the host interface port number assigning to the host mapping is displayed E When Host Affinity Mode is enabled an affinity group number belonging to the volume is displayed F When Host Affinity Mode is enabled an affinity group name belonging to the volume is displayed Either D or E F is displayed G The numb...

Page 678: ...32 WE Yes Yes 12 LV12 222 CM 1 Port 1 1 EA RO Yes No 13 LV13 13 1 Affinity Group 1 10 No No 111 LogicalVolume111 CM 1 Port 0 10 No The following example displays information about all the hosts with volume 1 reserved In the host information the reservation key and the reservation status of the volume corresponding to the reservation key are displayed CLI show reservation volume number 1 Volume Hos...

Page 679: ...nformation Settings and Display 5 4 Utility ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 679 5 4 6 Cache Utilities This section explains the commands related to cache control utilities ...

Page 680: ...000000000 0x00 0x00 0x00 0x00 A B C D E F G A Volume number B Volume name C Logical block address LBA of volume in which pinned data is retained D Reason code E Sense key F Additional sense code Sense code G Additional sense code qualifier Sub sense code The following example displays a list of all the pinned data CLI show pinned data Volume LBA RC SK ASC ASCQ No Name 1 VolumeNumber0001 0x00000000...

Page 681: ...play 5 4 Utility show pinned data ETERNUS CLI User s Guide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 681 The following example displays the MVV volume CLI show pinned data Volume LBA RC SK ASC ASCQ No Name 12 Vol12 0x00 0x00 0x00 0x00 ...

Page 682: ...s section explains the commands related specifically to the CLI environment itself 6 1 CLI Environment This section explains the commands relating specifically to the CLI environment itself Forcibly releasing the resources that CLI and the controller firmware control Selecting page scroll mode Logoff Viewing help ...

Page 683: ...o complete processing and then retry the failed command Or use this command to forcibly release exclusive resources This is useful when access is lost due to unexpected errors such as a terminal disconnecting suddenly This command forcibly releases resources on which CLI and RAID controller firmware have an exclusive hold Syntax Parameter No parameters Example s Do not use this command while setti...

Page 684: ...tting of this command The timeout interval that is set by this command is shared in the ETERNUS Disk storage system Syntax Parameter Example s set clienv idle timeout timeout minute timeout This parameter specifies the idle timeout interval in minutes until an idle status CLI session is automatically logged off Any value from 5 minutes to 60 minutes can be specified If omitted the current idle tim...

Page 685: ...ide Copyright 2015 FUJITSU LIMITED P2X0 1030 09ENZ0 685 logoff logout exit These commands exit the CLI session All of these commands have the same effect Syntax Parameter No parameters Example s logoff logout exit Any of the following commands exit a CLI session CLI logoff CLI logout CLI exit ...

Page 686: ...y identified is treated as a complete command Examples of incorrect parameter specifications are as follows CLI help mapping object section only CLI help sh incomplete verb section of command CLI help show m incomplete object section of command show mapping and show migration are complete commands that match the help string In this case CLI cannot identify a unique command The following example ha...

Page 687: ...RAID group name RAID level and disks create snmp view Create an SNMP Management Information Base view MIB view create ssl certificate Re create a server key and a server certificate for network security using SSH SSL create user A new user name of profile create volume Create one or more volumes on a specified RAID group The following example displays a detailed description of the create raid grou...

Page 688: ...ied is incorrect Check the parameters identified in the details of this message E0006 Inconsistent status The status of the object specified is inappropriate for the operation requested Check the status of the object identified in the details of this message E0007 Inconsistent usage The usage requested is incorrect for the specified object Check the permitted usage of the object identified in the ...

Page 689: ...rting to an earlier version is not allowed for the hot application mode Confirm the controller firmware version by using the show firmware command and use the cold application mode if necessary E0033 Not applicable to this target The specified resource cannot be applied to the specified command process Check the specified resource E0034 Mainframe resources The specified Mainframe resource cannot b...

Page 690: ... Eco mode definitions can be deleted by using the release eco raid group command E0072 Resource is temporarily insufficient Could not execute because the required resource is temporarily insufficient Wait for a while and retry the command E0080 Resource limited A resource has reached its limit Confirm the limit and the status of the specified parameter function E0081 Number of active disks has rea...

Page 691: ...available space E0101 No memory Could not allocate working memory Close other sessions and try again E0102 Not available under system disk status This message indicates that the execution condition does not match with the BUD Bootup and Utility Device status Confirm the BUD status by using the show disks command E0103 Additional host interface port license is required Could not perform host interf...

Page 692: ...his message E0132 Already stopped Resources corresponding to the specified parameter are already stopped Check the resources identified in the details of this message E0140 One or more components have failed One or more components have failed during the maintenance operation Check the reason for the failure or take log files and ask the support department to investigate E0141 At least one resource...

Page 693: ...rogress status of RAID group operations by using the show raid group progress command E0157 Remote Copy session active Could not execute while Remote Copy sessions are processing Check the status using GUI or ACM ETERNUS SF AdvancedCopy Manager E0158 Controller firmware update in process Could not execute while controller firmware update is processing Wait for a while and retry the command after t...

Page 694: ...red by another process Wait for a while and try again E0175 Competing with deleting RAID group in background process A RAID group is being deleted by another process Wait for a while and try again E0176 Competing with registering volume in background process A volume is being registered by another process Wait for a while and try again E0177 Competing with deleting volume in background process A v...

Page 695: ...ration is being performed by another process Wait for a while and try again E0197 Quick Unmap in process Quick UNMAP releasement of physical area is being performed Wait for a while and try again E0198 Flexible tier migration in process Flexible Tier Migration is being performed Wait for a while and try again E0200 Competing with setting Flexible tier mode in background process The Flexible Tier m...

Page 696: ...rrect file header A syntax error was detected in the specified REC path information file Specifically the header identifier is incorrect Check the output line given in the details of this message and amend the header identifier E0301 Syntax error in REC path information Version mismatch A syntax error was detected in the specified REC path information file Specifically the version information is m...

Page 697: ...cified REC path information file Specifically an inappropriate host interface port mode was used Check the output line given in the details of this message and amend it to the appropriate host interface port mode E0315 Syntax error in REC path information Number of storage links for one storage system over upper limit A syntax error was detected in the specified REC path information file Specifica...

Page 698: ...be set to the specified Thin Provisioning Pool RAID Migration cannot be set for the specified Thin Provisioning Pool Check the Thin Provisioning Pool by using the show thin pro pools command E0337 The specified Flexible Tier Pool does not have a Flexible Tier Sub Pool A Flexible Tier Sub Pool does not exist in the specified Flexible Tier Pool Check whether Flexible Tier Sub Pools exist by using th...

Page 699: ...hen retry the command E0359 Log Transmission of E Mail Notification is enabled Log transmission via email notification is enabled Disable the log transmission and then retry the command E0360 AIS SSL certificate is not registered A proper root certificate is not registered Register a proper root certificate E0361 AIS SSL certificate is invalid The root certificate is invalid or has expired Registe...

Page 700: ...ause a concurrent firmware update is currently being performed for a controller E5101 Check thin pro pool Status The Thin Provisioning Pool cannot be formatted Check the status of the Thin Provisioning Pool by using the show thin pro pools command E5105 Not exist unused disk enough The number of unused disks is insufficient E5107 RAID type is temporary The RAID group is temporarily being used E510...

Page 701: ...the show host port mode command E5501 iSNS server cannot be connected from the specified iSCSI CA port The iSNS server is not set for the specified iSCSI CA port E5701 The factory setup is not done The factory settings have not been performed E6000 Advanced Copy session that covers the entire volume is active An Advanced Copy session that affects the entire volume is being performed E6001 The spec...

Page 702: ...ed for another session E7106 The resource in the internal is depleted All of the internal resources are already been used E7107 State of source volume or destination volume is error An error has occurred in the source volume or the destination volume E7108 The specified volume don t have migration session during startup A migration session is not running for the specified volume E7109 The specifie...

Page 703: ... x x show hardware information x x x x x Thin Provisioning Pool Management set thin pro license x x x x delete thin pro license x x x x show thin pro license x x x x x create thin pro pool x x x x set thin pro pool x x x x delete thin pro pool x x x x show thin pro pools x x x x show thin pro pool progress x x x x expand thin pro pool x x x x format thin pro pool x x x x set eco thin pro pool x x ...

Page 704: ...x x x x set dedicated spare x x x x release dedicated spare x x x x set eco mode x x x x show eco mode x x x x x create eco schedule x x x x set eco schedule x x x x delete eco schedule x x x x show eco schedule x x x x x set eco raid group x x x x release eco raid group x x x x show eco raid group x x x x x Volume Management create volume x x x x 2 set volume x x x x 2 delete volume x x x x delet...

Page 705: ...olume x x x x set odx buffer volume x x x x delete odx buffer volume x x x x Host Interface Management set fc parameters x show fc parameters x x set sas parameters x show sas parameters x x set iscsi parameters x show iscsi parameters x x set fcoe parameters x show fcoe parameters x x create host wwn name x x set host wwn name x x delete host wwn name x x show host wwn names x x x discover host w...

Page 706: ...ost affinity x x x x x set mapping x x x x copy mapping x x x x release mapping x x x x show mapping x x x x x set host response x x x x delete host response x x x x show host response x x x x x set host sense x x x x delete host sense x x x x show host sense x x x x x set ca reset group x x x x show ca reset group x x x x x test iscsi ping x create port group x x x x set port group x x x x delete...

Page 707: ... show login users x x x x set password x x x x initialize all users x x x x import ssh public key x x x x delete ssh public key x x x x set radius x x x x show radius x x x x x Advanced Copy Management set advanced copy license x x x x delete advanced copy license x x x x show advanced copy license x x x x x set advanced copy policy x x x x show advanced copy policy x x x x x set advanced copy par...

Page 708: ...te rec disk buffer x x 3 show rec disk buffer x x 3 format rec disk buffer x x 3 release rec disk buffer x x 3 Network Management set network x x x x show network x x x x x set firewall x x x x show firewall x x x x x set snmp x x x x show snmp x x x x x create snmp manager x x x x set snmp manager x x x x delete snmp manager x x x x show snmp manager x x x x x create snmp view x x x x set snmp vi...

Page 709: ...rver key x x x x create ssl certificate x x x x export ssl certificate request x x x x import ssl certificate x x x x set ais connect x x x x show ais connect x x x x x set ais connect remote session x x x x test ais connect x x x x send ais connect log x x x x test ais connect event notification x x x x import ais ssl certificate x x x x Miscellaneous set date x x x x show date x x x x x set ntp ...

Page 710: ... sed key groups x x x x x change sed key x x x x recover sed key group x x x x shutdown x x x x Performance start performance x x x x stop performance x x x x show performance x x x x set raid tuning x x x x show raid tuning x x x x x set cache parameters x x x x show cache parameters x x x x x Event Log Information show events x x x x delete events x x x x Maintenance Operation hot expansion x x ...

Page 711: ...S2 clear disk error x x x x show port error x x x x show bad data info x x x x Utility show diagnosis x x x x set led x x x x show led x x x x set event parameters x x x x show event parameters x x x x x set subsystem parameters x x x x show subsystem parameters x x x x x release reservation x x x x show reservation x x x x show pinned data x x x x CLI Environment set clienv force unlock x x x x s...

Page 712: ...tus show status x show enclosure status x show fru ce x show fru de x show disks x x x show hardware information x Thin Provisioning Pool ECO Management set thin pro license x delete thin pro license x show thin pro license x x create thin pro pool x set thin pro pool x delete thin pro pool x show thin pro pools x x x x show thin pro pool progress x x x expand thin pro pool x format thin pro pool ...

Page 713: ...dicated spare x set eco mode x show eco mode x x create eco schedule x set eco schedule x delete eco schedule x show eco schedule x x set eco raid group x release eco raid group x show eco raid group x x Volume Management create volume x set volume x delete volume x delete all volumes x show volumes x x x x x x show volume progress x x x x x show volume mapping x x x x x x format volume x expand v...

Page 714: ...tier migration x x set odx mode x show odx mode x create odx buffer volume x set odx buffer volume x delete odx buffer volume x Host Interface Management set fc parameters x show fc parameters x x set sas parameters x show sas parameters x x set iscsi parameters x show iscsi parameters x x set fcoe parameters x show fcoe parameters x x create host wwn name x set host wwn name x delete host wwn nam...

Page 715: ...how affinity groups x create lun group x set lun group x copy lun group x delete lun group x show lun groups x set host path state x show host path state x x set host affinity x copy host affinity x release host affinity x show host affinity x x set mapping x copy mapping x release mapping x show mapping x x set host response x delete host response x show host response x x set host sense x delete ...

Page 716: ...qos group x show lu qos groups x x delete lu qos group x set host lu qos x show host lu qos x x set lu qos schedule x show lu qos schedule x x start host lu qos performance x stop host lu qos performance x show host lu qos performance x User Management create role x set role x delete role x show role x x create user x set user x delete user x show users x x show login users x x Command name User P...

Page 717: ...lize snap data volume x show snap data volume x show snap data pool x x delete snap data pool volume x start advanced copy x stop advanced copy x show advanced copy sessions x x set host port mode x show host port mode x import rec path x show rec path x x export backup rec path x show backup rec path information x convert rec path x measure rec round trip time x set rec round trip time x set rec ...

Page 718: ... x delete snmp manager x show snmp manager x create snmp view x set snmp view x delete snmp view x show snmp view x create snmp user x set snmp user x delete snmp user x show snmp user x create community profile x set community profile x delete community profile x show community profile x set snmp trap x delete snmp trap x show snmp trap x test snmp trap x export enhanced mib x Command name User P...

Page 719: ...x set ais connect remote session x test ais connect x send ais connect log x test ais connect event notification x import ais ssl certificate x Miscellaneous set date x show date x x x x set ntp x show ntp x x set storage system name x show storage system name x x x x set encryption x show encryption x x x set boxid x show boxid x set power synchronization x show power synchronization x set sed au...

Page 720: ...ey group x show sed key groups x x x x change sed key x recover sed key group x 1 x shutdown x Performance start performance x stop performance x show performance x set raid tuning x show raid tuning x x set cache parameters x show cache parameters x Event Log Information show events x delete events x Maintenance Operation hot expansion x show btu date x show remote dir x show firmware version x C...

Page 721: ...ror x show bad data info x Utility show diagnosis x set led x show led x set event parameters x show event parameters x set subsystem parameters x show subsystem parameters x release reservation x show reservation x x show pinned data x CLI Environment set clienv force unlock x set clienv idle timeout x logoff logout exit x x x x x x x x x x x x help x x x x x x x x x x x x Command name User Polic...

Page 722: ...se x x show thin pro license x x x create thin pro pool x x x set thin pro pool x x x delete thin pro pool x x x show thin pro pools x x x x x show thin pro pool progress x x x x x expand thin pro pool x x x format thin pro pool x x x set eco thin pro pool x x x release eco thin pro pool x x x show eco thin pro pool x x x x x Flexible Tier Management show flexible tier mode x x x delete flexible t...

Page 723: ... x x Volume Management create volume x x x set volume x x x delete volume x x x delete all volumes x x x show volumes x x x x x show volume progress x x x x x show volume mapping x x x x x format volume x x x expand volume x x x start migration x x x stop migration x x x show migration x x x x x start balancing thin pro volume x x x stop balancing thin pro volume x x x show balancing thin pro volu...

Page 724: ...create host wwn name x x x set host wwn name x x x delete host wwn name x x x show host wwn names x x x x x discover host wwn names x x x create host sas address x x x set host sas address x x x delete host sas address x x x show host sas addresses x x x x x discover host sas addresses x x x create host iscsi name x x x set host iscsi name x x x delete host iscsi name x x x show host iscsi names x...

Page 725: ...how host sense x x x set ca reset group x x x show ca reset group x x x x x test iscsi ping x x x create port group x x x set port group x x x delete port group x x x show port groups x x x x x create host group x x x set host group x x x delete host group x x x show host groups x x x x x set host lu qos mode x x x show host lu qos mode x x x x x set lu qos group x x x show lu qos groups x x x x x...

Page 726: ...advanced copy license x x x x x set advanced copy policy x x x show advanced copy policy x x x x x set advanced copy parameters x x x show advanced copy parameters x x x x x initialize snap data volume x x x show snap data volume x x x x x show snap data pool x x x x x delete snap data pool volume x x x start advanced copy x x x stop advanced copy x x x show advanced copy sessions x x x x x set ho...

Page 727: ...x x set firewall x x show firewall x x set snmp x x show snmp x x x x x create snmp manager x x set snmp manager x x delete snmp manager x x show snmp manager x x create snmp view x x set snmp view x x delete snmp view x x show snmp view x x create snmp user x x set snmp user x x delete snmp user x x show snmp user x x create community profile x x set community profile x x delete community profile...

Page 728: ...x send ais connect log x x test ais connect event notification x x import ais ssl certificate x x Miscellaneous set date x x show date x x x x x set ntp x x show ntp x x x x x set storage system name x x show storage system name x x x x x set encryption x x show encryption x x x x set boxid x x x show boxid x x x set power synchronization x x show power synchronization x x set sed authentication x...

Page 729: ...aid tuning x x x x x set cache parameters x x x show cache parameters x x x Event Log Information show events x x x delete events x x x Maintenance Operation hot expansion x x show btu date x x x x x show remote dir x x x x x show firmware version x x x x x Maintenance Information export log x x x x x export panic dump x x x show panic dump x x x export config information x x x show config informa...

Page 730: ...parameters x x set subsystem parameters x x show subsystem parameters x x release reservation x x x show reservation x x x x x show pinned data x x x x x CLI Environment set clienv force unlock x x x x x set clienv idle timeout x x logoff logout exit x x x x x x help x x x x x x Command name Default Role Monitor Admin Storage Admin Account Admin Security Admin Maintainer ...

Page 731: ... V10L46 V10L50 Storage System Status show status x show enclosure status x show fru ce x show fru de x show disks x show hardware information x Thin Provisioning Pool Management set thin pro license x delete thin pro license x show thin pro license x create thin pro pool x set thin pro pool x delete thin pro pool x show thin pro pools x show thin pro pool progress x expand thin pro pool x format t...

Page 732: ...le x delete eco schedule x show eco schedule x set eco raid group x release eco raid group x show eco raid group x Volume Management create volume x set volume x delete volume x delete all volumes x show volumes x show volume progress x show volume mapping x format volume x expand volume x start migration x stop migration x show migration x start balancing thin pro volume x stop balancing thin pro...

Page 733: ... parameters x create host wwn name x set host wwn name x delete host wwn name x show host wwn names x discover host wwn names x create host sas address x set host sas address x delete host sas address x show host sas addresses x discover host sas addresses x create host iscsi name x set host iscsi name x delete host iscsi name x show host iscsi names x discover host iscsi names x create affinity g...

Page 734: ...est iscsi ping x create port group x set port group x delete port group x show port groups x create host group x set host group x delete host group x show host groups x set host lu qos mode x show host lu qos mode x set lu qos group x show lu qos groups x delete lu qos group x set host lu qos x show host lu qos x set lu qos schedule x show lu qos schedule x start host lu qos performance x stop hos...

Page 735: ...rs x initialize snap data volume x show snap data volume x show snap data pool x delete snap data pool volume x start advanced copy x stop advanced copy x show advanced copy sessions x set host port mode x show host port mode x import rec path x show rec path x export backup rec path x show backup rec path information x convert rec path x measure rec round trip time x set rec round trip time x set...

Page 736: ...ser x create community profile x set community profile x delete community profile x show community profile x set snmp trap x delete snmp trap x show snmp trap x test snmp trap x export enhanced mib x set email notification x show email notification x test email x set event notification x show event notification x set lcd suppress x show lcd suppress x set smi s x show smi s x create ssh server key...

Page 737: ...ization x set sed authentication x show sed authentication x set syslog notification x show syslog notification x set audit x show audit x set sed key machine name x show sed key machine name x set sed key server x show sed key servers x import ssl kmip certificate x create sed key group x set sed key group x delete sed key group x show sed key groups x change sed key x recover sed key group x shu...

Page 738: ...anic dump x export config information x show config information x show disk error x clear disk error x show port error x show bad data info x Utility show diagnosis x set led x show led x set event parameters x show event parameters x set subsystem parameters x show subsystem parameters x release reservation x show reservation x show pinned data x CLI Environment set clienv force unlock x set clie...

Page 739: ... host This is why the host affinity setting is performed Setting host affinity with a host group a port group and a LUN group Set the parameter to control the host interface port Register a host that can be used to identify the HBA Hot Bus Adapter Create a host group 1 Create a port group 2 Create a LUN group 3 Set the relationship between a host group port group and LUN group 1 Host group A host ...

Page 740: ... Procedure 1 Creating RAID groups An example of creating a RAID group is shown below For more details refer to 3 3 RAID Group Management page 111 Procedure 1 Specify 004 and 005 for the disk drive numbers and create a RAID group that is named r1 RAID1 End of procedure 2 Creating volumes An example of creating volumes is shown below For more details refer to 3 4 Volume Management page 144 Procedure...

Page 741: ...2 HBA3 and HBA4 together and create a host group named HG01 4 Group host interface ports 000 and 100 together and create a port group named PG0001 CLI set fc parameters port 000 100 connect fabric CLI create host wwn name wwn 40000000abc80e38 name HBA1 CLI create host wwn name wwn 40000000abc80e00 name HBA2 CLI create host wwn name wwn 40000000abc80e01 name HBA3 CLI create host wwn name wwn 400000...

Page 742: ...pping host affinity mode D 2 1 Specifying a Host and Performing Mapping Host Affinity Mode page 743 1 Enable the host affinity mode of the host interface port 2 Set the parameter that controls the host interface port 3 Register a host that is used to identify the HBAs Host Bus Adapter 4 Create an affinity group 5 Set the relationship between the host host interface ports and affinity group Specify...

Page 743: ...e details refer to 3 5 Host Interface Management page 193 The example below is for a Fibre Channel interface Procedure 1 Enable the host affinity mode of host interface port 001 2 Set the connection of the host interface port 001 to fabric 3 Register a host WWN named HBA5 4 Map a volume with a LUN and create an affinity group named AG002 In this example volume v2 and LUN 20 are mapped 5 Set the re...

Page 744: ...nse number 0 End of procedure When Step 4 is performed for mapping specifying the port group the results of executing the following commands vary set lun group delete lun group set affinity group delete affinity group The set lun group and delete lun group commands change the LUN mapping that is set by specifying a port group in response to the changed setting of the LUN group Example CLI set fc p...

Page 745: ... mode of host interface ports 000 and 001 2 Set the connection topology of host interface ports 000 and 001 to fabric CLI show lun group lg name AG002 LUN Group No 0 LUN Group Name AG002 LUN Volume Status Size MB Multi Group No Name Volume 0 8 v0 Available 512 No 20 10 v2 Available 512 No CLI set affinity group ag name AG002 volume name v1 lun 1 CLI show mapping CM 0 CA 0 Port 0 Host Affinity Mode...

Page 746: ...apping 2 Deleting affinity groups LUN groups port groups host groups or registered host D 3 2 Deleting Affinity Groups page 747 D 3 3 Deleting LUN Groups page 748 D 3 4 Deleting Port Groups page 748 D 3 5 Deleting Host Groups page 748 D 3 6 Deleting Registered Hosts page 749 Delete created affinity groups LUN groups port groups host groups or registered hosts 3 Deleting volumes D 3 7 Deleting Volu...

Page 747: ...nd of procedure Releasing LUN mapping An example of deleting LUN mapping is shown below For more details refer to 3 5 Host Interface Management page 193 Procedure 1 Cancel all of the mapping definitions for host interface ports 000 and 001 End of procedure D 3 2 Deleting Affinity Groups An example of deleting an affinity group is shown below For more details refer to 3 5 Host Interface Management ...

Page 748: ...ocedure D 3 4 Deleting Port Groups An example of deleting a port group is shown below For more details refer to 3 5 Host Interface Management page 193 Procedure 1 Delete port group PG0001 End of procedure D 3 5 Deleting Host Groups An example of deleting a host group is shown below For more details refer to 3 5 Host Interface Management page 193 Procedure 1 Delete host group HG01 End of procedure ...

Page 749: ...d HBA4 End of procedure D 3 7 Deleting Volumes An example of deleting volumes is shown below For more details refer to 3 4 Volume Management page 144 Procedure 1 Delete volumes v0 v1 and v2 End of procedure D 3 8 Deleting RAID Groups An example of deleting a RAID group is shown below For more details refer to 3 3 RAID Group Management page 111 Procedure 1 Delete the RAID group named r1 End of proc...

Page 750: ... disable connect FC AL rate auto loop id assign manual loop id 0x00 frame size 2048 bytes reset scope initiator lun reserve cancel disable rec line no 0 rec transfer sync enable rec transfer stack enable rec transfer consistency enable rec transfer through enable set sas parameters host affinity disable rate auto reset scope initiator lun reserve cancel disable set iscsi parameters host affinity d...

Page 751: ...e rec transfer consistency enable rec transfer through enable set fcoe parameters host affinity disable rate 10Gbit s frame size 2048 reset scope initiator lun reserve cancel disable fcf vlan id disable fcf vlan id value 0 fcf fabric name disable fcf fabric name value 0 set host response status unit attention inquiry byte0 disable vpd type3 conflict disable timeout 25 seconds version 5 host specif...

Page 752: ...ning 70 error 99 set advanced copy parameters resolution x 1 table size 0MB sdpe 1GB ec opc priority auto warning 80 copy schedule mode session balancing import rec path indicator enable export backup rec path indicator enable convert rec path indicator enable set rec multiplicity multiplicity auto priority level auto copy schedule mode session balancing set rec buffer buffer size 128MB forwarding...

Page 753: ...authentication method md5 encryption enable set snmp trap version v3 port number 162 export enhanced mib version v1 set email notification send disable port maintenance port number 25 authentication auto retry count 0 retry interval 1 second timeout 5 seconds partial mode disable partial size 64KB send log disable iom log enable customer info enable set lcd suppress parts error enable parts warnin...

Page 754: ...cert filename server crt key filename server key indicator enable Command Parameter Default value set encryption mode disable set power synchronization auto power disable resume power disable preset pman power fail signal positive low battery signal positive ups shutdown signal negative ups shutdown disable Command Parameter Default value set event parameters blink panel led enable redundant copy ...

Page 755: ...otice This manual was prepared with the utmost attention to detail However Fujitsu shall assume no responsibility for any operational problems as the result of errors omissions or the use of information in this manual Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual The content of this manual may not be reprod...

Page 756: ......