background image

1

02/20 | 

036865-001

A. INSPECTION

Inspect the carton and water cooler for evidence of rough handling and concealed damage. Damage claims should be filed  

with carrier.

B. TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE

1.  NOTE: Provincial and local plumbing codes may prohibit use of saddle taping valves for water line connection in some applica-

tions. All connections must conform to applicable plumbing codes.

2.  Locate and install plumbing and electrical service if required, in accordance with the Rough-in Drawing. Filter units have  

additional instructions on a label inside the access panel. Read these before installing unit.

3.  FLUSH BUILDING WATER SUPPLY LINE BEFORE INSTALLING UNIT.

4.  Install unit on the wall hanger. 

Wall hanger is shipped fastened to the back of the unit.

5. 

Install a trap in the waste line and a shut off valve in the water supply line.

 An in-line strainer is furnished in the “Water Sup-

ply” tube. Connect the “Water Supply” tube to the shut off valve. This connection should not be a solder joint or flare connection 

to allow access to the strainer for service. To ease removal of the strainer, a sheet metal screw may be lightly threaded into the 

open end. When the unit has an internal waste trap, the trap should be wrapped with the insulating tape to prevent sweating. Use 

of the 1 3/4" diameter knockout for a waste line is not recommended because of a potential conflict with ADA* toe space clear-

ance requirements. Check your local building code inspector for approval.

6.  Rotate the fan blade by hand to see that it is free of obstructions.

7.  Check the available power supply against the water cooler data plate to assure the correct electrical service. This drinking water 

cooler is intended to be connected to a 20A minimum ground fault circuit interrupting (GFCI) device to meet UL requirements. 

Plug power supply cord into wall outlet. The rear most 1 3/8" diameter knockout in the frame bottom is for an externally located 

electrical supply. Make sure the knockout hold edge is smooth and free of any burrs. Use of a Heyco bushing #2184 in the 

knocked out hole is recommended in order to prevent damage to the service cord and to close up excess opening around the 

cord. Route the cord so it does not interfere with ADA* space requirements. 

8.  To fill cold water tank on water cooler versions, open water supply line shut-off and push any one of the front or side pushbuttons 

to allow water to flow to the bubbler. Run water until stream free of bubbles.

9.   To Adjust Bubbler:

a)  All Pushbutton models are equipped with a Cartridge Regulator. The KEP8AC and KEPAC have a slot in the shelf below the 

Pushbuttons. Insert a screwdriver in the slot to adjust regulator. Turn adjustment clockwise to increase stream height. To ac-

cess the KEPV8AC adjustment, remove the Bezel and Button from the front of the cooler.

C. MAINTENANCE

The only maintenance operation required is the removal of dirt and lint from the condenser where used. Inspection should be made at 

3-month intervals. Disconnect the power supply cord, then clean the condenser with a small stiff non-wire or vacuum cleaner attach-

ment brush when required. Observance if this procedure will insure adequate air circulation through the condenser so operation is 

efficient and economical.

D. OVERLOAD PROTECTION

The compressor motor, where used, is equipped with an automatic reset protector which will disconnect the motor from the line in 

case of an overload.

E. LUBRICATION

This unit is equipped with a hermetically sealed compressor and requires no additional lubrication. The fan motor, where used, on this 

unit seldom needs oiling, but if required, a few drops of SAE 10 oil should be used.

DRINKING FOUNTAIN INSTALLATION

For All Universal KEP( )AC Series Drinking Fountains

Summary of Contents for KEP AC Series

Page 1: ...terrupting GFCI device to meet UL requirements Plug power supply cord into wall outlet The rear most 1 3 8 diameter knockout in the frame bottom is for an externally located electrical supply Make sur...

Page 2: ...E ANTICIPATED AND BEFORE SHIPPING THE WATER COOLER American With Disabilities Act WARNING The warranty and the Underwriters Laboratory Listing for this machine are automatically voided if this machine...

Page 3: ...359 27 686 25 32 20 3 8 WATER SUPPLY OPTIMUM LOCATION STUB OUT 1 25 INCH ELECTRICAL OUTLET OPTIMUM LOCATION 1829 32 480 T15 DRIVE SIZE TORX HEAD SCREWS 1 1 4 IPS WASTE OPTIMUM LOCATION STUB OUT 1 25 I...

Page 4: ...t blade screwdriver into the slotted hole as shown The screwdriver will engage the stream height adjuster in the cartridge plunger Turn clockwise to increase stream height or counter clockwise to redu...

Page 5: ...trol 027040 039 027040 039 Not applicable 23 Relay 036056 003 036056 003 Not applicable 24 Overload 036055 003 036055 003 Not applicable 25 Start capacitor 60 MFD 027956 008 027956 008 Not applicable...

Page 6: ...el KEP __ series SPECIFICATIONS CHILLED DRINKING FOUNTAIN Split Level KEP _ ACSL Series Single KEP _ Series WIRING DIAGRAM DRINKING FOUNTAIN Voltage 115 VAC 10 1 PH 60 Hertz Size 17 5 8 W 18 5 8 D 18...

Page 7: ...V rifier que la pale du ventilateur n est pas bloqu e en la faisant tourner la main 7 V rifier que les caract ristiques de l alimentation lectrique correspondent bien celles inscrites sur la plaque s...

Page 8: ...nt automatique qui coupe l alimentation lectrique du moteur en cas de surcharge E LUBRIFICATION L appareil est quip d un compresseur enti rement tanche qui ne n cessite aucune lubrification suppl ment...

Page 9: ...12 3 4 324 6 3 8 162 5 1 4 133 3 15 16 84 1 1 2 38 14 1 8 359 27 686 25 32 20 ALIMENTATION EN EAU DE 3 8 EMPLACEMENT OPTIMAL DE LA TUBULURE DE SORTIE 1 25 POUCE EMPLACEMENT OPTIMAL DE LA PRISE LECTRIQ...

Page 10: ...8 po dans le trou avec fente tel qu illustr Le tournevis p n tre dans le dispositif de r glage de la hauteur du jet situ dans le plongeur de la cartouche Tourner dans le sens horaire pour augmenter la...

Page 11: ...ment isol 035469 055 SP 035469 055 SP Ne pas applicable 22 R glage du refroidissement 027040 039 027040 039 Ne pas applicable 23 Relais 036056 003 036056 003 Ne pas applicable 24 Surcharge 036055 003...

Page 12: ...en eau froide 8 GPH Compresseur 1 4 HP Compresseur pleine charge 4 4 amp res Fluide frigorig ne 134a Charge de fluide frigorig ne 3 95 oz Temp rature ambiant 90 F Temp rature d eau d alimentation 80 F...

Reviews: