background image

User Manual IN14-6-V2 Nixie Clock 

 

Power for your Nixie Clock 

 

The clock does not include a wall adapter. You should get a universal adapter yourself, these 

are not very expensive. The preferred voltage is 12VDC, but often 9VDC – 15VDC will do 

nicely too. The middle pin of the plug is the positive. Universal adapters often come with a set 

of various plugs, choose one that fits. If none them fits, you can use the dc-plug is included 

with the clock. If the clock does not work, you may have gotten the polarity wrong. Change 

the polarity and try again. 

 

Setting the Nixie Clock 

 

Turn on the clock by plugging in the wall adapter. The time will start at 12:00:00 and blinks. 

Press and hold the set button, for about 5-6 seconds until the first tube will turn on its decimal 

point and starts blinking. Release the button.  

 

Now, with each short press of the button, you can advance the first digit. The format is 24 

hours, so the first tube only changes from 0-1-2 etcetera. After the digit is set correct, press 

the button again for 2 seconds, and see that the second tube will turn on its decimal point. Set 

all the other tubes in the same way.  

 

Once you have set all digits, press and hold the button for 5-6 seconds, and the clock will 

resume normal operation. 

 

At first, this may seem a bit of a hassle, but after a while you will notice that it is remarkably 

easy to set the clock. 

  

Calibrating the Nixie Clock 

 

The clock comes calibrated. There’s a label on the bottom with the correct calibration value 

for use at normal room temperature. If you use the clock in extreme cold or warm places, you 

may want to recalibrate it. Press and hold the set button, for about 7-8 seconds. While you 

hold it, you will first see that the first tube turns on its decimal point, and then the second tube 

will turn on its decimal point. Now release the button. There should be 4 digits displayed now. 

Here you can set a new calibration value for the timing of the clock. First set this value at 

5000. After setting this value, press and hold the button for 5-6 seconds, to return to normal 

mode. This value will be stored inside the microcontroller. Turn off the clock, and turn it on 

again. 

 

Now set the clock, using a reliable time reference. Set the clock as described earlier, and wait 

until your time reference matches the time you have set. Now press and hold the set button for 

5-6 seconds, and notice that the clock now runs synchronous with your reference, both 

displaying the same time. 

 

Using the standard calibration value of 5000, the clock should run with a better accuracy than 

+/- 10 seconds per day. Let the clock run for a couple of days, and note the time difference 

between the nixieclock and the reference clock you have used. Calculate the number of 

milliseconds per hour the clock runs too fast or too slow.  

 