MIMO2+, Multiple Input – Multiple Output 
Module User Manual                                                                          

 

 

 

                         1080 Centre Rd.  Ste C 

Auburn Hills, MI 48326   

www.fortrezz.com 

Phone: (248) 481-7092 

         [email protected]  

Made in USA 

072916

  

INTRODUCTION 

The MIMO2+ (Multiple Input - Multiple Output) Module is an interface / bridge module that has two voltage inputs and two dry contact relays.   
The MIMO2+ is a Security Enabled Z-Wave

TM

 Plus Wireless device compatible with other Z-Wave

TM

 certified products. 

            

 

SPECIFICATIONS 

Power:  

12  to  16  volts  DC  from  regulated  Power  supply  @~  500mA 
capability

 

Frequency Range: 

908.4MHz (US);   868.4MHz (EU) 

Distance Range: 

Max 100ft line of sight in unobstructed environment 

PCB Size (LxW): 

3.55" (90.2mm) x 3.3" (84mm)  

Enclosure Size (LxWxD): 

3.8" (96.5mm) x 3.8" (96.5mm) x 1.15" (29.3mm) 

Weight: 

6 OZ  (170 gram)

 

Operating Temperature: 

-10⁰C (14F) to +70⁰C (158F) 

 

 
Input Signals 1, 2 (SIG1 & SIG2):   Digital or Analog Input 0 to 16V DC.  The trigger levels and 

hysteresis can be set independently via the Configuration 
Command Class for each input. 

 
Input Signal Impedance: 

Z=66 ohm at 10KHz (for SIG1 or SIG2).  This impedance is = 
66 ohm = 34 ohm + j 540uH.

 

Output Relays 1, 2 (REL1 & REL2): SPDT, Max. Switching power of 120W; 10uA to 10A; High Dielectric strength coil-contacts: 1,000 VAC; Open 

contacts: 750 VAC; Conforms to FCC Part 68 requirements; Ag + Au clad bifurcated contacts fully sealed. 

 
System Requirement:  

Any Z-Wave

TM

 -enabled network and controller. 

 
 

WARNINGS AND PRECAUTIONS 

 

The  dry  contact  relays  are  not  capable  of  supporting  higher-than-specified  loads. 

Exceeding  the  specified  switching  power  will  cause 

damage to the unit and may cause damage to property and/or personal injury, including loss-of-life.

  

 

o

 

WARNING – Do not attempt to use the relays to switch residential or industrial Alternating Current (AC) lines.  
The relays are to be used for low-power load control only.  Refer to above electrical specifications for relays. 
 

 

Do not store highly flammable items such as oily rags or other combustibles near your MIMO2+.  

 

Do not apply electrical power to the unit unless the unit is fully assembled.  

 

Install unit in accordance with electrical codes and regulations. In case you are unsure about any parts of these instructions consult an 
electrician or Z-Wave

TM

 home automation specialist. 

 

Disconnect power source before working on or servicing the unit. Failure to do so could result in personal injury. 

 

Eye protection should be worn while installing or servicing the system.  Failure to do so could result in personal injury.  

 

MIMO2+  functionality  is  based on  wireless  (RF)  transmissions.     Any  wireless  transmission can  be  subject  to  RF  interference  or  loss-of-
communication.    This  interference  or  loss-of-communication  may  cause  the  unit  to  not  operate  as  intended.    You,  the  end-user,  are 
responsible for ensuring that the MIMO2+ functionality and installation meets your desired requirements. 
 

o

 

WARNING - The MIMO2+ must not be used in life support and / or safety applications. 
 

 

Do not place MIMO2+ on or near metal objects. This decreases range and/or blocks wireless transmissions.   

 

Information provided in this manual is for your convenience and may be superseded by updates.  The specifications and this manual are 
subject to change without notice.  It is your responsibility to ensure that the MIMO2+ functionality meets your needs and specifications. 

Summary of Contents for MIMO2+

Page 1: ...ge to the unit and may cause damage to property and or personal injury including loss of life o WARNING Do not attempt to use the relays to switch residential or industrial Alternating Current AC lines The relays are to be used for low power load control only Refer to above electrical specifications for relays Do not store highly flammable items such as oily rags or other combustibles near your MI...

Page 2: ...ically activated by Z WaveTM commands However the user can override Z WaveTM control by configuring the input trigger conditions to be mapped to the output relays via logical AND OR functions DIAGRAM The MIMO2 features two inputs and two outputs in the form of relays Wire connections can be made to the Normally Open NO or Normally Closed CO relay terminals Control and monitoring is available via Z...

Page 3: ...efault every 20 minutes SIG2 Multilevel Sensor Report Multichannel upon change of trigger or periodically Default every 20 minutes 2 2 One of the following depending on whether Endpoint 1 or Endpoint 2 SIG1 Basic Set upon change of trigger SIG2 Basic Set upon change of trigger 3 4 REL1 REL2 1 Lifeline the controller should automatically set up this association 2 One of the following depending on w...

Page 4: ...CONFIGURATION SIG1 and SIG2 Endpoints 1 and 2 The default trigger configuration for the analog inputs SIG1 and SIG2 simulates a Digital threshold around 1 6V voltage falling or 2V voltage rising That is the inputs will trigger when the input is untriggered and the level goes above approximately 2V and will reset when the level is triggered and the level goes below approximately 1 6V The trigger ra...

Page 5: ...equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to...

Page 6: ...y nature FORTREZZ LLC expressly disclaims all implied warranties including but not limited to the implied warranties of merchantability and fitness for a particular purpose FORTREZZ LLC does not warrant guarantee or make any representations regarding the use or the results of the use of the products or any accompanying materials in terms of their correctness accuracy reliability or otherwise In no...

Page 7: ... REL1 COMMAND_CLASS_SWITCH_BINARY Sets or resets REL1 COMMAND_CLASS_SENSOR_MULTILEVEL General Purpose Value type for 12 bit ADC analog SIG1 input COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_SECURITY COMMAND_CLASS_MULTI_CHANNEL_V4 allows Endpoints to be commanded status ed COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 Device Type Supported Command Classes Endpoints 1 2 SIG1 SIG2 Generic Device Type GENERIC_TYP...

Page 8: ...alues over 127 to their signed numerical value 1 REL1 Configuration b7 b5 Input to Relay Mapping REL1 Basic Binary Switch commands ignored see Relay Mapping section below b4 b0 Momentary latch count resolution 100ms 0 non momentary 5 00000101b No relay mapping moment latch for 0 5s 1 128 127 0x00 0xFF 2 REL2 Configuration b7 b5 Input to Relay Mapping REL1 Basic Binary Switch commands ignored see R...

Page 9: ...Lower Threshold Low 128 Unsigned Value 128 1 128 127 0x00 0xFF 12 SIG2 Upper Threshold High 1 Unsigned Value 255 1 128 127 0x00 0xFF 13 SIG2 Upper Threshold Low Unsigned value must be greater than Lower Threshold High and less than Upper Threshold High 2 Unsigned Value 254 1 128 127 0x00 0xFF Analog Input Voltage Conversion SIG1 and SIG2 and Triggering The input signal voltage conversion to Multil...

Page 10: ...vel Sensor Command class to verify that configured trigger points correspond to the desired input voltage levels The default trigger configuration for the analog inputs SIG1 and SIG2 is a threshold around 1 85V That is the inputs will trigger when the input is untriggered and the level goes above approximately 1 85V and will reset when the level is triggered and the level goes below approximately ...

Page 11: ...48 481 7092 sales fortrezz com Made in USA 072916 The following diagrams illustrate another way of considering this triggering capability The X axis in these diagrams represent time passing from left to right The diagrams show the triggering state as the input voltage rises from zero to a certain point and then falls back to zero ...

Page 12: ... REL1 is set if SIG1 is triggered or if SIG2 is triggered cleared otherwise 2 If only bit 7 is set for the REL2 configuration then the mapping equation is REL2 state SIG1 AND SIG2 REL2 is set if SIG1 and SIG2 are both triggered cleared otherwise 3 If only bit 5 is set for the Relay 1 configuration then the mapping equation is REL1 state SIG1 REL1 is set if SIG1 is triggered cleared otherwise POWER...

Reviews: