Check the label affixed to the side of the drive and make sure the 
input and output power specifications match the available power 
source and motor.

PRODUCT: E510-2P5-H-U

 

MOTOR RATING: 0.5 HP

INPUT

: AC 3PH 200-240V (+10%,-15%) 50/60Hz 4A

OUTPUT : AC 3PH 0-599 Hz 2.6A   

         IP20/NEMA 1

ENCLOSURE : IP20

P/N BARCODE

      S/N BARCODE

TD200-20P5-3PH

1

2

���

4

5

4.8” / 12cm

2” / 5cm

4.8” / 12cm

2” / 5cm

Enclosure

Cooling Fan

Vent

Operating 
Temperature:

-10°C - +50°C (14-122 °F) 

If AC Drive is placed in an enclosure, provide 
additional cooling and ventilation to maintain 
ambient temperatures below 50°C (122 °F)

AC Drive Label

Minimum Spacing Requirements

Adequate thermal management is key to extending the life of the AC 
drive. Overheating and excessive dust/debris will shorten the life of 
the drive significantly.

Identify Drive Specifications

Enclosure

Cooling Fan

2” / 5cm

Vent

1

 Verify receipt of proper drive model 

2

 Verify Input Power 

3

 Provide adequate circuit provision 

      • Ensure proper wire size 
      • Provide proper circuit protection 
      • Comply to all local codes and regulations 

4

 Output Amperage 

      • Ensure output is adequate to meet the full load amps of the 

motor or application 

5

 Verify Environment 

      • Provide proper environmental protection 
      • Install drive in a clean and cool environment protected from 

contaminants and debris

QUICK START 
GUIDE

STEP  

1

Mounting / Spacing Requirements

STEP  

2

Applicable Models: 
• 120V (1PH): 0.25 – 1HP 
• 240V (1PH): 0.25 – 3HP 

• 240V (3PH): 0.5 – 3HP 
• 480V (3PH): 1 – 3HP

CAUTION

 

 

Installation and wiring must be performed by qualified personnel 

Do NOT remove any protective covers or attempt any wiring while input 
power is applied. Connect all power wiring and control wiring before 
applying input power. Always turn OFF the power supply before 
attempting AC Drive installation and terminal wiring. 

Internal capacitors hold a charge after power supply has been removed. 
After disconnecting power, wait at least 10 minutes before touching any 
wiring, circuit boards, or components.  

Check all wiring to ensure all connections are correct after installation of 
AC Drive and any other devices. Failure to comply could result in serious 
injury, death, fire, or damage to the AC Drive. 

Do not use an improper voltage source. Failure to comply could result in 
in serious injury, death, fire, or damage to the AC Drive. Verify the rated 
voltage of the AC Drive matches the voltage of the incoming power 
supply before applying power. 

Do not connect a contactor or switch in series with the AC Drive and the 
motor.

WARNING

 

 
This document is intended to provide a short guide on the installation 
and setup of a FMX Tough Drive. Refer to the user manual for all safety 
precautions and further details regarding installing, wiring, operating, 
servicing, or inspecting the AC Drive.