4.

 

Connect the input of the pressure instrument under test 
to the test pressure port (item  

B

). 

5.

 

Unscrew the pressure release knob (item 

I

) to vent 

pressure from the pump. 

6.

 

Zero the pressure module. The zeroing procedure 
depends on which pressure module and calibrator you 
are using. 

7.

 

Turn the fine adjustment knob (item 

D

) to mid-range. 

8.

 

Tighten the pressure release knob finger tight. 

9.

 

Set the handle stroke length to maximum. 

10.

 

Prime pump as described under “Priming the Pump”. 

11.

 

Shorten handle-stroke length to reduce pumping force. 

W

Caution 

Pressure may rise rapidly if the 
pressurized volume is small. 

12.

 

Compress the handles to apply incrementally higher 
pressure. 

13.

 

For fine pressure adjustment, use the fine adjustment 
knob. 

Priming the Pump 

To prime the pump: 
1.

 

Connect the pressure module and calibration hose 
(Fluke HTH or equivalent) as shown in the drawing. Be 
sure to use several wraps of Teflon tape on all threaded 
connections to insure a proper seal. 

2.

 

Fill the reservoir approximately 2/3 with either de-ionized 
water or mineral oil. 

3.

 

Before connecting the other end of the calibration hose 
to the device under test, raise the open end of the hose 
to a level above the fluid in the reservoir. 

4.

 

Close the pressure release knob and begin pumping the 
HTP until fluid begins to come out of the hose. Note that 
depending on the volume of the hose this may take 50 or 
more strokes. 

5.

 

Once the fluid starts to flow out of the hose, connect to 
the unit under test. 

6.

 

When testing is complete, disconnect the hose from the 
unit under test. If using the Fluke HTH hose, place the 
plastic sealing cap back over the exposed end of the 
hose to help retain the fluid until the pump is used again. 
Retaining the fluid in the hose will greatly reduce the 
number of strokes required to re-prime the pump. 

Replacement Parts 

Rebuild Kit, Fluke PN 2812606 
Hydraulic Fluid Reservoir Rebuild Kit, Fluke PN 2844341 
Handle Assembly Rebuild Kit, Fluke PN 2844352 

 

LIMITED WARRANTY AND LIMITATION OF LIABILITY 

This Fluke product will be free from defects in material and workmanship for 
one year from the date of purchase. This warranty does not cover fuses, 
disposable batteries, or damage from accident, neglect, misuse, alteration, 
contamination, or abnormal conditions of operation or handling. Resellers are 
not authorized to extend any other warranty on Fluke’s behalf. To obtain 
service during the warranty period, contact your nearest Fluke authorized 
service center to obtain return authorization information, then send the product 
to that Service Center with a description of the problem. 

THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, 
SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR 
IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING 
FROM ANY CAUSE OR THEORY. Since some states or countries do not 
allow the exclusion or limitation of an implied warranty or of incidental or 
consequential damages, this limitation of liability may not apply to you. 

Fluke Corporation 

P.O. Box 9090 

Everett, WA  98206-9090 

U.S.A. 

Fluke Europe B.V. 

P.O. Box 1186 

5602 BD Eindhoven 

The Netherlands 

11/99 

Introduction 

The Fluke-700HTP-1 Hydraulic Test Pump (hereafter called 
the pump) is a portable source of high pressure. The pump 
has the following specifications: 

 

Maximum pressure: 690 bar (10,000 psi) 

 

Hydraulic media: distilled water or mineral based 
hydraulic oil 

 

Wetted materials: 303 stainless steel, aluminum, 
polyurethane, PTFE, nitrile, and nylon 

 

Weight:  1.29 lb (.58 kg) 

 

Dimensions: length 9.5 in (241 mm), width 6.1 in  
(155 mm), depth 2.6 in (66 mm) 

Box Contents 

 

Model 700HTP-1 Hydraulic Test Pump with 1/4 in NPT 
tee installed 

 

(2) 1/4 in NPT male to 1/4 in BSP female adapter 

 

1/4 in NPT male to 1/4 in NPT male fitting 

 

Instruction Sheet 

Contacting Fluke 

To contact Fluke or for service, call one of the following 
telephone numbers: 

USA: 1-888-44-FLUKE (1-888-443-5853) 
Canada: 1-800-36-FLUKE (1-800-363-5853) 
Europe: +31 402-675-200 
Japan: +81-3-3434-0181 
Singapore: +65-738-5655 
Anywhere in the world: +1-425-446-5500 
Or, visit Fluke's Web site at 

www.fluke.com

®

 

Fluke-700HTP-1

 

 

Hydraulic Test Pump

 

Instruction Sheet

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Reviews: