Getting Started

 

 

 

 

PN 2340639 
January 2005 

© 2005 Fluke Corporation, All rights reserved. Printed in USA 
All product names are trademarks of their respective companies 

.

Summary of Contents for 396

Page 1: ...396 397 Waveform Generators Getting Started PN 2340639 January 2005 2005 Fluke Corporation All rights reserved Printed in USA All product names are trademarks of their respective companies ...

Page 2: ...rvice center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepaid FOB Destination If Fluke determines that failure was caused by neglect misuse contami...

Page 3: ...tor is used for controlling the Instrument and generating editing and downloading waveforms from a remote computer The following highlights the Instrument and the ArbExplorer features Feature Highlights 397 Dual output configuration with independent waveform control 397 Tight phase offset control between channels 1 point resolution 14 bit vertical resolution Nearly 19 bit offset resolution 396 1 M...

Page 4: ...e each channel can be controlled separately to generate different waveform amplitude and waveforms sequence Having a single sample clock source is an advantage in a dual channel configuration because it allows tight control over inter channel synchronization and leading edge start phase where the initial skew between the two channels is just a few nanoseconds Output Functions The Instrument is com...

Page 5: ...ge from 8192 to 8191 14 bits Using a high speed clocking circuit the digital contents of the arbitrary waveform memory are extracted and routed to the Digital to Analog Converter DAC The DAC converts the digital data to an analog signal and the output amplifier completes the task by amplifying or attenuating the signal at the output connector Memory Segmentation There is no need to use the complet...

Page 6: ...trol There is no limit to the number of units that can be daisy chained multiple unit synchronization is built into each Instrument Safety Considerations The Instrument has been manufactured according to international safety standards The Instrument meets EN61010 VDE 0411 03 81 and UL 1244 standards for safety of commercial electronic measuring and test equipment for instruments with an exposed me...

Page 7: ...The correct fuse to use is Littelfuse Cat No 218500 T 250VAC 0 5A All other devices connected to or in proximity to this instrument are properly grounded or connected to the protective third wire earth ground Supplied Accessories The Instrument is supplied with this Getting Started Manual a disk containing the Getting Started Manual and the Users Manual and a disk containing a Windows version of t...