background image

 

 

 

Flightcell Iridium Extreme Cradle 

 

Installation and Operation Manual 

 
MAN_CR5_001 
Document version 1.0 
Date 05 November 2014 
 

www.flightcell.com 

Содержание CRP 05001

Страница 1: ...1 Flightcell Iridium Extreme Cradle Installation and Operation Manual MAN_CR5_001 Document version 1 0 Date 05 November 2014 www flightcell com ...

Страница 2: ...2 ...

Страница 3: ...ection 7 3 5 Antenna connection 7 3 6 Data connection 8 3 7 Power supply to the Iridium phone 8 4 Using the Iridium phone with the Flightcell Iridium Extreme Cradle 9 4 1 Installing and releasing your Iridium satellite phone 9 4 2 Automated power on and off 9 5 Warranty and contact details 10 5 1 Limited warranty for your Flightcell Iridium Extreme cradle 10 5 2 Flightcell International contact de...

Страница 4: ... use with the Flightcell DZMx voice data and tracking system The DZMx integrates the Extreme phone into the aircraft communications system The cradle may also be used to connect an Iridium Extreme phone direct to an aircraft audio panel This manual is intended for use by engineers installing and maintaining the Flightcell Iridium Extreme Cradle It describes the physical mechanical and electrical c...

Страница 5: ...0mVrms to 1 15Vrms adjustable 775mVRMS nominal Input impedance 600Ω SPKR audio Output levels Up to 3Vrms into 150Ω adjustable 775mVRMS nominal Output impedance 150Ω Satphone data RS 232 levels 9600bps Dimensions Width Overall 70mm 2 76 Depth with or without phone 65mm 2 58 Height including satphone 236mm 9 30 excluding satphone 222mm 8 74 Weight Including satphone 956g 33 7oz Excluding satphone 68...

Страница 6: ...ed For example M27500 24SB2T14 Screened pairs should be used for MIC SPK RS232 Tx Rx The other flow control lines RTS CTS DSR DTR RI DCD can utilise either screened or unscreened cables in any groupings Where screened cable is used we recommend that it be grounded at one end only to minimize ground loops Where the GPO signal is used we recommend using a single screened cable with GPO GND connected...

Страница 7: ...ection to the audio panel without using a Flightcell DZMx The cradle can be interfaced directly to an audio panel provided that audio levels are compatible If connected to an audio panel the cradle always provides mic bias and sidetone 3 5 Antenna connection The Flightcell Iridium Extreme Cradle has a single TNC antenna connector to connect the phone to an approved Iridium antenna Please contact F...

Страница 8: ...serial data connection is configured for 9600 baud 3 7 Power supply to the Iridium phone The Iridium phone cradle contains a power supply that manages the voltage supplied to the phone to levels required to safely charge and operate the phone Power is supplied via the connector on the base of the Iridium phone ...

Страница 9: ...hone down against the locating pins rotate it backwards until it is hard against the back of the cradle note that it is necessary to press the phone downwards against the resistance of the rubber cushioning around the phone 4 Release the latch To release the phone depress the latch and rotate the phone out of the cradle 4 2 Automated power on and off The Iridium phone cradle is designed to power t...

Страница 10: ...lts Connected with reverse polarity Installed in direct contravention to the guidelines outlined in the technical installation manual Physically damaged or a fault has occurred due to the product being used beyond what is considered normal use causing unusual deterioration of the product If the product is deemed to be faulty or in need of repair please contact Flightcell International Ltd to obtai...

Страница 11: ...11 6 Version history Release version Date Author Change note number Description Issue 1 5 November 2014 J Mace FCN0646 Document created ...