background image

SPARE PARTS DIAGRAM FOR 

First Choice Group 
Blakeney Way, Kingswood Lakeside 
Cannock, Staffs, WS11 8LD 
TEL: 01543 577778  FAX: 01543504141 
Email: [email protected] 
Web: www.firstchoice-cs.co.uk 

Gas Oven Range

LMR9 

Summary of Contents for Lincat LMR9

Page 1: ...RTS DIAGRAM FOR First Choice Group Blakeney Way Kingswood Lakeside Cannock Staffs WS11 8LD TEL 01543 577778 FAX 01543504141 Email enquires firstchoice cs co uk Web www firstchoice cs co uk Gas Oven Ra...

Page 2: ...IS329 ECN3592 Medium Duty Gas Oven Range LMR9 User Installation and Servicing Instructions...

Page 3: ...afety and operating instructions carefully before using this product Please pay particular attention to all sections of this User Guide that carry warning symbols and notices WARNING This is a Warning...

Page 4: ...he installation instructions and should conform to the following requirements Do not obstruct or block the appliance flue Installation must include sufficient ventilation to prevent the occurrence of...

Page 5: ...kW Hob rating per burner Propane Gross 4 6 kW Hob Low Rate all gasses 1 1kW Connection and Operating Pressures Gas inlet connection BSPT Male when nipple is fitted Supply Pressure Natural 20mbar Opera...

Page 6: ...LOSURES Please ensure the following items are included with this piece of equipment Model LMR9 Tick Warranty Card 1 Pressure Governor 1 Natural gas only Pan Supports 3 Connection Nipple 1 2 BSP 1 User...

Page 7: ...dically inspected and replaced as necessary When making the connection to the appliance an isolating cock should be fitted into the supply line close to the unit for emergency shutdown or servicing pu...

Page 8: ...r dependent on gas type Replace data plate Conversion of Gas type Model Gas Pressure Injector Mark Part No Regulated LMR9 G20 20 mbar B 1 75 175 JE151 15 3 mbar H 0 85 85 JE116 Z 2 50 250 JE64 G31 37...

Page 9: ...as through to the burner Depress the ignitor button on the control panel to light the gas at the oven burner On establishing a flame at the burner keep the knob depressed for approximately 15 seconds...

Page 10: ...p of the oven insulation against the intlet manifold and the top of the oven surface FASCIA PANEL REMOVAL Remove the screws DD situated each end of the underside of the fascia panel AA Remove the cont...

Page 11: ...thermocouple whilst feeding through the new thermocouple Re assemble in the reverse order Control Valve and Oven Thermostat Remove the control knobs and fascia panel Remove the nuts P from the contro...

Page 12: ...or Propane JE152 Hob bypass injector Natural JE116 Hob bypass injector Propane JE117 Thermostat bypass injector Natural JE116 Thermostat bypass injector Propane JE117 Oven injector Natural JE64 Oven i...

Page 13: ...aged Check injector for blockages Tighten connections Replace valve Yes Yes Yes No No No Replace thermocouple Recheck system Piezo oven ignitor not sparking Burner s will not light or stay lit FAULT F...

Page 14: ...nnot accept responsibility for work carried out by other persons Please quote both the model and serial numbers from the data plate attached to the unit Give brief details of the service requirement I...

Page 15: ...IS329 ECN3592 14 Notes...

Page 16: ...IS329 ECN3592 15 Notes...

Page 17: ...IS329 ECN3592 16...

Reviews: