129-145 REMOTE MOUNTING KIT

The 129-145-1, -2 and -3 mounting kits provide an easy, efficient method to panel mount the ED510
display module. Each kit contains a mounting plate, gasket, two (2) 8-32 x 1 1/4" mounting screws,
and connection cable: ED580-4 (4 foot cable) with the 129-145-1, ED580-8 (8 foot cable) with the
129-145-2, and ED580-2 (2 foot cable) with the 129-145-3.

ED610 MULTI-PORT CABLE CONNECTOR WITH TERMINAL STRIP

The ED610 is a multi-port adapter with two RJ45 and one RJ12 (4P4C) telephone jack connectors
and a 10-connector terminal strip. It facilitates remote cable connections between the E110 control,
ED510 Display Module, and the E500 Communication Interface. The ED610 is mounted on a flat
surface with two screws and is recommended where cable runs greater than eight (8) feet are required.

ED580 REMOTE DISPLAY CABLES

The ED580 remote display cable is a cable in varying lengths (2', 4', and 8') with an RJ45 connector
on each end of the cable. The ED580 is used to mount the ED510 display module remote from the
Flame-Monitor control (with EP programmers, Engineering code 28 or later or EPD programmers,
Engineering code 02 or later).

ED512 REMOTE MOUNTING CABLES

The ED512 remote mount cable is a cable in varying lengths (2', 4', and 8') with an RJ12 (4P4C) con-
nector on each end of the cable. The ED512 is used with the ED610 multi-port connector for connect-
ing the Flame-Monitor control (with EP programmers, Engineering code 28 or later or EPD
programmers) to the E500 Communication Interface. The ED512 cables are also used to customize
E300 messages. Refer to bulletins E-3001 and EC-3451.

ED150 REMOTE RESET CABLES

The Remote Reset Cables are 10 conductor flat ribbon cables with a connector on one end and with
two stripped and tinned conductors on the opposite end. Maximum length available is 25 feet
(7.62m). A momentary contact switch connected to the stripped end of the cable will allow for remote
reset of the FLAME-MONITOR.

See CAUTION on Page 3.

FLAME-MONITOR™

SYSTEM ACCESSORIES

129-145 Remote Display Mounting Kit

                  ED610 Multi-port Cable Connector

and Terminal Strip

ED580 Remote Display Cables

ED512 Remote Mounting Cables

ED150 Remote Reset Cables

E-8002

MARCH 27, 2015

Summary of Contents for 129-145-1

Page 1: ...splay module remote from the Flame Monitor control with EP programmers Engineering code 28 or later or EPD programmers Engineering code 02 or later ED512 REMOTE MOUNTING CABLES The ED512 remote mount cable is a cable in varying lengths 2 4 and 8 with an RJ12 4P4C con nector on each end of the cable The ED512 is used with the ED610 multi port connector for connect ing the Flame Monitor control with...

Page 2: ... immunity of the FLAME MONITOR system The connector nearest to the ferrite core must be plugged into the EP Programmer TO ENSURE THE SYSTEM IS PROPERLY GROUNDED 1 Connect the back plane of the mounting cabinet to a proper earth ground 2 Ground the FLAME MONITOR wiring base to the mounting cabinet by using mounting screws with star washers to ensure proper electrical contact 3 Connect the green gro...

Page 3: ...osition of the ferrite core is not critical on the ED580 cable connected between the ED510 dis play and ED610 adapter The Flame Monitor control will drive two 2 ED510 display modules The Belden cable 9554 has 4 twisted pairs with an overall shield Conductor pairs are color coded red and black and numbered at one 1 inch intervals e g 1 black 2 red Maximum cable distance of the ED510 from the Flame ...

Page 4: ...ING BOX ON PAGE 2 TO ENSURE THE SYSTEM IS PROPERLY GROUNDED Ground the shield at one end only of each individual wiring run Total maximum cable distances shall not exceed 4 000 feet NOTE Cable should be routed within the cabinet so that it doesn t come in close proximity with ignition wires high energy contactors or solenoids ED610 10 9 8 7 6 5 4 3 2 1 J5 J1 ED510 REMOTE E110 FLAME MONITOR ED580 2...

Page 5: ...d EPD programmers hav ing and engineering code of 4 or greater MAKE SURE THE FLAME MONITOR SYSTEM IS PROPERLY GROUNDED REFER TO THE WARNING BOX ON PAGE 2 TO ENSURE THE SYSTEM IS PROPERLY GROUNDED Ground the shield at one end only of each individual wiring run Total maximum cable distances shall not exceed 4 000 feet NOTE Cable should be routed within the cabinet so that it doesn t come in close pr...

Page 6: ...nd ED510 as shown using the ED580 cables Wire a normally open momentary push button switch across termi nals 8 4 Jumper J4 on the ED611 must be in position 1 to 2 Refer to Figure 8 REFER TO CAUTION FOR REMOTE RESET ON PAGE 3 ED610 10 9 8 7 6 5 4 3 2 1 J5 J1 ED610 10 9 8 7 6 5 4 3 2 1 J5 J1 E110 OPTION 1 TO PC PLC ETC ED512 2 4 8 FLAME MONITOR BELDEN 8761 E110 ED512 2 4 8 FLAME MONITOR CLEAR BLACK ...

Page 7: ...ication software program P N E720 running on an IBM compatible PC is required for communication with the E340 controls Fireye recommends using the E500 Communication interface when communicating with the E340 controls since the E500 provides communication with the Flame Monitor flame safeguard con trols as well However the EC485 converter can be used to communicate only with the E340 con trols FLA...

Page 8: ... NO WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY EXPRESS OR IMPLIED Except as specifically stated in these general terms and conditions of sale remedies with respect to any product or part number manufactured or sold by Fireye shall be limited exclusively to the right to replace ment or repair as above provided In no event shall Fireye be liable for consequential or special dam ages of any na...

Reviews: