Page 1: ...INSTRUCTION MANUAL FOR INSTALLATION MAINTENANCE AND USE ELECTRIC KETTLES PMDE100 PMDE150 ...

Page 2: ...00 31 01 2005 Tutti Prima emissione First issue Erste Ausgabe Première émission Budel 01 09 02 2005 Pag 18 Mod schema elettrico Modify Wiring Diagram Veränderfe Elektrischer Schaltplan Mod schéma électrique Budel 02 30 06 2005 Tutti Aggiunto Termostato digitale Added Digital thermostat Zuschlag Digital thermostat Ajout du Thermostat digital Budel 03 21 03 2006 Pag 20 Mod schema elettrico Modify Wi...

Page 3: ...tial bonding 8 2 2 2 Connection to waterworks 9 2 3 Commissioning and testing 9 2 3 1 New setting parameters work s digital thermostat 9 2 3 2 New setting parameters safety digital thermostat 10 2 4 Maintenance of the appliance 10 2 4 1 Possible failures and their elimination 10 Part 3 Use and cleaning 3 1 Warnings and hints for user 11 3 2 Instructions for use 11 3 2 1 Details regarding the opera...

Page 4: ...Instruction manual for installation maintenance and use Electric Kettles PMDE GB Page 4 di 16 Part 4 Figures and details 4 1 Wiring diagram Mod 100 150 lt 14 4 2 View of appliance 15 4 3 Controls 16 ...

Page 5: ...gned other uses are improper and hence dangerous During operation surfaces can become hot and require special operation Unplug the appliance in case of failures or improper operation Apply exclusively to a service centre for repairs or maintenance Any important information about the appliance required for technical service is contained in the technical data plate see figure View of appliance If te...

Page 6: ...45 135 PM9DE100 PM9DE100 A 900 Models With A as end letter pressare kettle PM8DE100 PM8DE100 A 800 900 900 600 415 110 100 3N AC 400 V 50 60Hz 13 1 5X6 10 10 mm mm mm mm mm l l kW mm 2 mm mm Specifications Description Width A Depth B Height C Vat diameter Vat height Total volume Usable volume Voltage Input Power Power cable Hot water connection Cold water connection ...

Page 7: ...he following regulations current regulations on the matter any hygienic sanitary regulations concerning cooking environments municipal and or territorial building regulations and fire prevention prescriptions current accident prevention guidelines electricity board regulations concerning safety the regulations of the electrical power supply company or agency any other local prescriptions 1 5 SPECI...

Page 8: ...iance has been designed for these supplies 2 2 1 ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL BONDING Warning The appliance is supplied to operate according to the power supply indicated on the data plate As mentioned the appliance must be connected to the power supply by way of a multiple pole main isolating switch and protection device that must be proportioned to the power of the appliance 1 mA per...

Page 9: ...he electrical connection has been performed according to standards In addition check that once the appliance has been installed the power cord is neither subject to stretch nor in contact with nor surfaces Now proceed to light the appliance as directed in the instructions for use While the appliance is in use voltage should not differ from the nominal voltage more than 10 The test report must be c...

Page 10: ... the need for other maintenance calls and unexpected failures It is also advisable to apply for a maintenance contract with the customer 2 4 1 POSSIBLE FAILURES AND THEIR ELIMINATION Warning Only technically qualified service centres can perform the operations described below Caution Before switch off and on the equipment operation necessary to re set the safety thermostat remove always the reason...

Page 11: ...e all outputs electrical power supply and water must be cut off instantly In case of recurrent failures contact a service technician 3 2 INSTRUCTIONS FOR USE Before cooking with the appliance for the first time wash the interior of the cooking vat thoroughly Warning Fill the cooking vat up to a maximum of 40 mm under the overflow border according to the maximum level mark including the food to be ...

Page 12: ...eft During the cooking time to display the set temperature press SET for a second After 5 sec it comes back automatically to the actual temperature Just reaching the set temperature the equipment keeps the cooking conditions required Switch off the equipment by the external master switch Cooking stop press SET for 6 sec appears OFF the heating set functions are deactivated pressing it again for 6 ...

Page 13: ...lectrical power supply and water Air the room appropriately 3 5 SPECIAL PROCEDURES IN CASE OF FAILURES If the appliance should not work properly during use turn it off immediately and close or cut off all supplies electrical power supply and water Apply to a service centre for help The manufacturer shall not be held responsible nor has any warranty commitments for damage caused by non compliance w...

Page 14: ...tles PMDE GB Page 14 di 16 4 1 WIRING DIAGRAM MOD 100 150 LT LEGEND C1 Electromagnetic switch MAX R1 Heating element Re Relay 230v F1 Fender fuse 3 15A Tc K Temperature feeler TL Operating thermostat MA Line terminal board TS Temperature limiting device C2 Safety meter ...

Page 15: ...allation maintenance and use Electric Kettles PMDE GB Page 15 di 16 4 2 VIEW OF APPLIANCE LEGEND 1 Water cock A Hot water connection 2 Digital thermostat B Cold water connection 3 Cooking vat drainage tap E Electrical connection ...

Page 16: ...Page 16 di 16 4 3 CONTROLS WORKING THERMOSTAT AND SAFETY THERMOSTAT 1 button ARROWS used to modify the values 2 button SET on off 3 DISPLAY 4 LED heating in function 5 LED settino temperature phase Only for pressure kettles Valve and position of relief valve Closed valve Open valve ...