background image

Page 1 

 

OWNER’S MANUAL

 

Category I or II

 

Model: 300G-3PT w/814 (5300653) 

(300 Gallon 3-Point Sprayer w/8-Row Boom & Agitator

)

 

www.fimcoindustries.com 

1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD  57049      

Toll Free Phone: 800-831-0027 : Toll Free Fax: 800-494-0440 

[5008145   

 

 

 

 

 

(10/20)] 

BEFORE RETURNING THIS PRODUCT

FOR ANY REASON, PLEASE CALL

1-800-831-0027

MONDAY-FRIDAY, 8:00 AM TO 5:00 PM CST

If you should have a question or experience a problem with

your Fimco Industries Product: Visit our website @ 

www.fimcoindustries.com or call the Toll free number above. Our 

technical support representatives will be happy to help you. 

In most cases a customer service rep. can resolve

the problem over the phone.

To obtain prompt, efficient service, always remember to give the 

following information....

• Correct Part Description and/or part number

• Model number and Serial Number

Part descriptions and numbers can be obtained from the

illustrated parts list section(s) of this manual.

General Information 

Thank you for purchasing this product. The purpose of this 

manual is to assist you in operating and maintaining your  

3 Point sprayer.  

Retain a copy of your receipt for your unit, as it will be required 

to validate any warranty service. 

 

Warranted against manufacturer or workmanship defects from 

date of purchase with copy of receipt: 

 

Homeowner Usage: One Year 

 

Commercial Usage: 90 Days.

 

Assembly Instructions 

1. 

Install the preassembled tee valve sub-assembly to the 3-point 

carrier valve mount and position as shown. 

2. 

Slide a hose clamp on to the 

bypass hose (from the relief 

valve), then with a twisting 

motion, slip the bypass hose 

over the fitting on the top of 

the tank. Slide the hose clamp 

to the end of the hose and 

secure. 

Summary of Contents for 300G-3PT w/814

Page 1: ... the following information Correct Part Description and or part number Model number and Serial Number Part descriptions and numbers can be obtained from the illustrated parts list section s of this manual General Information Thank you for purchasing this product The purpose of this manual is to assist you in operating and maintaining your 3 Point sprayer Retain a copy of your receipt for your unit...

Page 2: ...e output side of the pump and securing with the hose clamp 5 The roller pump is NOT included with the assembly Attach the adapter the torque chain and S hook to the pump as needed It is intended for your pump to be mounted directly to the tractor PTO The torque chain needs to be secured to the tractor to keep your pump from spinning 6 Using sealant thread the gauge into the top of the tee valve as...

Page 3: ...cure with a 3 8 x 1 flange screw Level the outer booms by moving the slide clamps in or out as needed Tighten the bolts in the slide clamps to hold the clamps in place Slide in or out to level 14 Starting with the center section attach the appropriate hose assemblies onto each of the three boom sections Center the center hose assembly on the boom working outward to the ends of the booms the center...

Page 4: ...art the pump and open the valve to the boom nozzles Check the spray pattern Usually you can see the coverage better on a solid concrete surface such as a driveway Spraying Solutions Other Than Water Since all the tabulations are based on spraying water which weighs 8 34 lbs per USA gallon conversion factors must be used when spraying solutions which are heavier or lighter than water To deter mine ...

Page 5: ... the chemical into the tank You may use the handgun to spraying into the solution in order to mix the chemical and water The tips supplied as standard with the sprayer can be used for a wide variety of spraying applications Other tip sizes are available for different coverages The speed and pressure charts shown indicate the rates can be changed considerably by changing speed and pressure The pump...

Page 6: ...ressure setting firmly held in place by locknut Extra large passages to handle large flows Polypropylene with stainless steel spring Excellent chemical resistance EPDM O Rings Fore pressure to 150 p s i 1 4 port for pressure gauge 3 4 NPT M inlet F outlet connections Available ONLY in Repair Kit ONLY Available in Complete Assembly RH boom is activated Black 1 8 Orifice Red 5 32 Orifice Blue 3 16 O...

Page 7: ...ts list next page for part numbers IN to Pump Valve Detail Strainer Detail See Strainer Detail Available ONLY in complete assembly OUT to Valve Assy Out to Bypass Hose See Valve Detail Refer to pages 9 10 For Boom breakdown Part Numbers Cut View Of Inside Tank ...

Page 8: ...RH Nozzle Harness H o s e t o L H N o z z l e H a r n e s s Hose to Center Nozzle Harness H o s e t o V a l v e f r o m P u m p Available ONLY in complete assembly Parts List 300 3PT w 814 5300653 Hose to Agitator Out to Bypass Hose ...

Page 9: ...7 and 1 8 followed with jam locknut Ref 1 10 For the eyebolt thread the first nut Ref 1 13 onto the eyebolt then feed it through the hole in the angle under the lower center section Use the next nut for adjusting and the first nut for locking the eyebolt into position Detail B Detail C See Detail B Model 257 8 8 Row Boom Assembly 5300658 See Detail A Detail A See Detail C Opposite side has typical...

Page 10: ...truction which provides excellent chemical resistance including acids as well as excep tional wear life Compact size to prevent tip damage Removable pre orifice Excellent for systemic products and drift management Ref 20 1 257 8 Center Nozzle Harness 5277761 Ref 20 2 257 8 LH Nozzle Harness 5277806 Ref 20 2 257 8 RH Nozzle Harness 5277806 Nozzle Assemblies consist of Elbow Tee Cross style nozzles ...

Page 11: ...r Back Rack Mounted In High Position Center Back Rack Mounted In Low Position Mounting Angles ARE Used Mounting Angles are NOT Used Dimensions 73 000 37 500 58 063 47 500 9 500 54 000 Boom Width Folded Out 28 38 000 ...

Page 12: ...ited Warranty you must 1 provide written notice to Fimco Inc of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Inc 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Inc or an authorized dealer within a reasonable period of time For more information a...

Reviews: