background image

www.fastech.co.kr

Summary of Contents for Ezi-STEP-BT-42 Series

Page 1: ...www fastech co kr...

Page 2: ...www fastech co kr Operating Manual...

Page 3: ...gram 13 7 Setting and Operating 14 7 1 Status monitor LED 14 7 1 1 Status LED Function and Condition 14 7 1 2 Protection functions and LED blinking times 15 7 2 Setting Up Parameters 15 7 2 1 Resoluti...

Page 4: ...ver needed This manual divides safety precautions into Warning and Attention Contents of this manual are subject to change without prior notice for functional improvement change of specifications or u...

Page 5: ...off Otherwise an electric shock or a fire may occur All parameters of the Ezi STEP were accordingly set in the factory To change these parameters read the manual carefully first Otherwise the machine...

Page 6: ...phase of the current according to the pole position of the motor drastically suppressing vibration As reducing the vibration of the motor it is possible to operate in high speed regime EZi STEP can d...

Page 7: ...the speed of a stepping motor Ezi STEP automatically increases the supply voltage and prevents the torque lowering due to the low effective operating voltage on a motor from the back emf voltage in t...

Page 8: ...00 4000 5000 6400 8000 10000 20000 25000 36000 40000 50000 Set by RS232C Communication Default 10000 500 KHz Duty 50 Step Out Over Current Over Heat Over Voltage Power Status Green Alarm Status Red 10...

Page 9: ...BT 42 L No of phase 2 Excitation method Micro Step Max 50 000 P R Rated Torque A ph 1 5 1 5 1 5 Max HoldingTorque mN m kgf cm 270 2 8 400 4 1 490 5 0 Rotor Inertia g cm2 38 54 76 Power Supply DC 24V...

Page 10: ...p BT 56 M No of phase 2 Excitation method Micro Step Max 50 000 P R Rated Torque A ph 3 0 3 0 Max HoldingTorque mN m kgf cm 810 8 3 1300 13 3 Rotor Inertia g cm2 189 250 Power Supply DC 24V 4 0A 24V 4...

Page 11: ...L EzStep BT 56 XL No of phase 2 Excitation method Micro Step Max 50 000 P R Rated Torque A ph 3 0 3 0 Max HoldingTorque mN m kgf cm 2490 25 4 3540 36 1 Rotor Inertia g cm2 493 737 Power Supply DC 24V...

Page 12: ...11 5 Motor Torque Characteristics EzStep BT 42 S EzStep BT 42 M EzStep BT 42 L EzStep BT 56 S EzStep BT 56 M EzStep BT 56 L EzStep BT 56 XL...

Page 13: ...i STEP has been designed for indoor uses 2 The ambient temperature of the room should be 0 50 3 If the temperature of the case is higher than 50 radiate heat of the outside to cool down the case 4 Do...

Page 14: ...FG CW Pulse CW Pulse CCW Dir CCW Dir Alarm Run Stop 24VDC GND 24VDC Alarm Reset Motor Free Twisted Pair Shield Cable Alarm Reset signal line is also used for Motor FREE signal For details please refe...

Page 15: ...ing and Operating Status Color Function Blinking Condition Power Green Power input indication Lights when power is ON Alarm Red Alarm indication Blinking when protection function is activated Identifi...

Page 16: ...up exe from the folder Please select an appropriate Prot No and press icon Then it will display the various parameter values previously stored in the driver Display the parameter values stored in the...

Page 17: ...7 2 3 Pulse Mode As the pulsed inputs a user can choose One pulse mode Pulse Dir or two pulse mode CW CCW Select a desired pulse mode by pressing in icon on EzStep Setup screen 7 2 4 Rotation Directi...

Page 18: ...ted The power led green is blinking to show the status of Motor Free Press button to store the value selected into the driver The default factory setting is Normal 7 2 5 Polarity Run Signal Run Stop o...

Page 19: ...ame Ground NC Signal Connector CN2 Number 1 2 3 4 5 6 7 8 9 10 Function CW PULSE 9 1 10 2 CW PULSE CCW DIR CCW DIR ALARM 24 VDC GND 24 VDC ALARM RESET RUN STOP Frame Ground Input Output Input Input In...

Page 20: ...ram Motion Controller Power Control Unit DC Power Supply PC Network Motion Controller PLC Type For enlanging the length have to use the extensicn cable Power Cable Control Cable 30Cm 30Cm 20m 2m Stand...

Page 21: ...e used only to adjust the position by manually moving the motor shaft from the Ioad side By setting the signal ON the driver cuts off the power supply to the motor Then one can manually adjust output...

Page 22: ...to OFF blinks the Alarm LED disconnects the power to a motor and stops the motor simultaneously It operates reversely compare to Normal mode when you set Inverse mode It operates reversely compare to...

Page 23: ...Fastech Co Ltd MEMO...

Page 24: ...MEMO...