background image

DuraTech Cable SRL

User Instruction Manual

CMSRD15 Rev A

022120

FallTech  1306 S. Alameda Street  Compton, CA 90221, USA  Tel: 800-719-4619  Fax: 323-752-5613

This manual is intended to meet the Manufacturer’s Instructions as required by the Canadian Standards Association 

(CSA) Z259 and should be used as part of an employee training program.

Содержание DuraTech Cable SRL

Страница 1: ...llTech 1306 S Alameda Street Compton CA 90221 USA Tel 800 719 4619 Fax 323 752 5613 This manual is intended to meet the Manufacturer s Instructions as required by the Canadian Standards Association CS...

Страница 2: ...Tech SRL the SRL the SRD the self retracting device the equipment the device the product or the unit CMSRD15 Rev A 022120 1 0 Warnings and Important Information 2 0 Description 3 0 Application 4 0 Sys...

Страница 3: ...o falls because of increased fall arrest forces placed on the user s body In addition the onset of suspension trauma after a fall even may be accelerated for heavy users The user of the equipment disc...

Страница 4: ...ials specifications Figure 1 About FallTech DuraTech Cable SRL 1 2 3 4 5 1 Anchorage Connecting Handle 2 SRD Unit Housing 3 Product Warning Labels 4 Cable Stop Handle Assembly 5 Load Indicting Snap Ho...

Страница 5: ...ners to a single D ring at the same time C Never connect in a way that would produce a condition of loading on the gate D Never attach to a object in a manner whereby the gate of the snap hook or cara...

Страница 6: ...ght Training and equipment are the tools of fall hazard management There are several closely related facets of fall hazard management with a PFAS Anchorage Minimum Required Fall Clearance MRFC Swing F...

Страница 7: ...racting Lifeline C Walking Working Surface D Swing Fall Impact after fall event E Next Lower Level or Obstruction Figure 4 Calculating Required Fall Clearance Overhead Anchorage Figure 5 Swing Fall Ha...

Страница 8: ...xis Lateral Work Zone m Using Chart 1 to Find Additional Fall Clearance Overhead Non Leading Edge 0 6 m 2 ft increments along the X Axis represent the distance the user is working away from being dire...

Страница 9: ...own in Figure 7 indicates the reserve portion of the lifeline has been breached The SRD is no longer safe to use Remove the SRD from service DANGER DO NOT USE IF RED INDICATOR APPEARS REMOVE FROM SERV...

Страница 10: ...the lifeline to freewheel back into the housing Use a tag line to maintain tension and rewind the lifeline during periods of inactivity Use the tag line to retrieve the leg end connector for the next...

Страница 11: ...ust remove the SRD from service immediately This Secondary Red Visual Indicator signals the SRD unit s Reserve Line has been deployed or the SRD has experienced a fall event and is no longer in workin...

Страница 12: ...t not longer than intervals required by the manufacturer 7 2 Inspection Frequency CSA Z259 2 require an inspection by a competent person at least once a year by a person other than the user of the sys...

Страница 13: ..._______________________ Date of Manufacture _________________________ INSPECTION DATE INSPECTOR COMMENTS PASS FAIL CORRECTIVE ACTION NEEDED APPROVED BY 7 5 Inspection Document Record inspection result...

Страница 14: ...8 0 Labels The labels must be present and legible CMSRD15 Rev A 022120 14...

Страница 15: ...LE C7268C 3 16 Diameter Galvanized Steel Cable 15 2 m 50 ft Housing Cast Aluminum Anchorage Carabiner 22 2 kN 5 000 lbs Min 16 kN 3 600 lbs Gate Strength Leg End Connector 22 2 kN 5 000 lbs Min 16 kN...

Страница 16: ......

Страница 17: ...eda Compton CA 90221 U T l phone 800 719 4619 T l copieur 323 752 5613 Le pr sent manuel est con u pour r pondre aux consignes du fabricant telles qu exig es par l Association canadienne de normalisat...

Страница 18: ...SRL le SRL le DAR le dispositif autor tractable l quipement le dispositif le produit ou l unit CMSRD15 R v A 022120 1 0 Avertissements et informations importantes 2 0 Description 3 0 Utilisation 4 0...

Страница 19: ...essures graves ou de mort en raison de l impact plus important des forces antichute sur le corps de l utilisateur De plus l apparition d un choc de suspension ou d un traumatisme physique apr s une ch...

Страница 20: ...duit et du mat riel Figure 1 propos du c ble SRL DuraTech de FallTech 1 2 3 4 5 1 Poign e de connexion d ancrage 2 Bo tier pour l unit du DAR 3 tiquettes de produit mise en garde 4 Ensemble but e de c...

Страница 21: ...composants actifs mousquetons un seul anneau en D C Ne jamais brancher d une mani re qui entra nerait une charge sur le port D Ne jamais attacher un objet d une mani re qui emp cherait le mousqueton d...

Страница 22: ...en hauteur La formation et l quipement sont les outils les plus importants dans la gestion des risques de chute La gestion des risques de chute avec un SAP comporte plusieurs aspects li es Ancrage D g...

Страница 23: ...e secours rappel automatique C Surface de marche et de travail D Impact de la chute balanc e E Niveau inf rieur suivant ou obstacle Figure 4 Calcul du d gagement de chute requis Ancrage au plafond Fig...

Страница 24: ...dessus sans bord d attaque Les incr ments de 0 6 m 2 pi le long de l axe X repr sentent la distance laquelle l utilisateur se trouve directement sous le DAR Les incr ments de 1 5 m 5 pi vers le haut d...

Страница 25: ...ouge galement illustr e la figure 7 indique que la portion de r serve de la ligne de vie a t franchie Le DAR n est plus s r utiliser Mettre celui ci hors service DANGER NE PAS UTILISER SI L INDICATEUR...

Страница 26: ...rembobiner la ligne de vie pendant les p riodes d inactivit Utilisez la ligne d tiquette pour r cup rer le connecteur d extr mit de la jambe pour une prochaine utilisation NE PAS laisser la ligne d i...

Страница 27: ...et indicateur visuel rouge secondaire signale que la ligne de r serve de l unit a t d ploy e ou que le DAR a subi une chute et n est plus en tat de marche V rifiez qu il n y a pas de vis ou d crous ma...

Страница 28: ...striellement semi annuellement Au moins une fois par an mais pas plus longtemps que les intervalles exig s par le fabricant 7 2 Fr quence des inspections la norme CSA Z259 2 exige une inspection par u...

Страница 29: ...__________ Date de fabrication _________________________ DATE D IN SPECTION INSPECTEUR COMMENTAIRES SUCC S CHEC MESURES CORRECTIVES N CES SAIRES APPROUV PAR 7 5 Inspection du document inscrire les r s...

Страница 30: ...8 0 tiquettes Les tiquettes doivent tre pr sentes et lisibles CMSRD15 R v A 022120 30...

Страница 31: ...alvanis de 3 16 po de diam tre 15 2 m 50 pi Bo tier Fonte d aluminium Mousqueton d ancrage 22 2 kN 5 000 lb minimum 16 kN 3 600 lb R sistance de la vanne Connecteur d extr mit de la jambe 22 2 kN 5 00...

Отзывы: