background image

E3830 and E3860 

DOMINATOR

PLUS

Fryers

INSTALLATION and 
SERVICING INSTRUCTIONS

IMPORTANT

The installer must ensure that the installation of the appliance is in conformity with these instructions
and National Regulations in force at the time of installation. Particular attention MUST be paid to:

BS7671 IEE Wiring Regulations
Electricity at Work Regulations
Health And Safety At Work Act
Fire Precautions Act

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC
Directives for the voltages stated on the data plate.

WARNING

THIS APPLIANCE MUST BE EARTHED.

On completion of the installation, these instructions should be left with the Engineer-in-Charge for
reference during servicing. Further to this, The Users Instructions should be handed over to the User,
having had a demonstration of the operation and cleaning of the appliance.

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING
AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED
PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.

PREVENTATIVE MAINTENANCE CONTRACT

In order to obtain maximum performance from this unit we would recommend that a maintenance
contract be arranged with 

SERVICELINE

. Visits may then be made at agreed intervals to carry out

adjustments and repairs. A quotation will be given upon request to the contact numbers below.

WEEE Directive Registration No. WEE/DC0059TT/PRO

At end of unit life, dispose of appliance and any replacement 
parts in a safe manner, via a licenced waste handler.
Units are designed to be dismantled easily and recycling of all 
material is encouraged whenever practicable.

Falcon Foodservice Equipment

HEAD OFFICE AND WORKS

Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.

SERVICELINE CONTACT

Phone: 01438 363 000

Fax: 01438 369 900

T100774 Ref. 5

Summary of Contents for E3830

Page 1: ...of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDU...

Page 2: ...on systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where...

Page 3: ...ricity supply it must be correctly positioned and levelled Levelling is effected by turning the lower area of the adjustable legs If desired feet that allow floor fixing may be specified at time of or...

Page 4: ...ll glands which must not be overtightened The phial must be fixed in position within pan before tightening gland The phial tip should protrude from protective tube by 33mm Thermostat capillary tube mu...

Page 5: ...E3830 WIRING DIAGRAM...

Page 6: ...E3860 WIRING DIAGRAM 4 Element Version...

Page 7: ...6 3 2 1 19 26 AMBER NEON 15 21 RED NEON 17 21 OPERATING STAT 18 20 CONTACTOR A1 A2 7 9 8 10 15 17 28 18 11 TERMINAL BLOCK 28 14 TILT SWITCH SAFETY STAT 20 14 ELEMENT 9 ELEMENT 8 ELEMENT 7 ELEMENT BOX...

Page 8: ...5kW 230V 14 13 5 RED NEON 12 15 A1 A2 10 SAFETY STAT TRIP POINT 230 C OPERATING STAT 0 C 190 C 9 16 11 TILT SWITCH LOWERED POSITION 18 6 15 AMBER NEON 1 2 3 4 5 6 7 5 2 1 9 16 11 6 18 12 15 10 13 14 7...

Page 9: ...AFETY STAT TRIP POINT 230 C 16 17 A1 A2 17 21 RED NEON 19 23 26 7 8 CONTACTOR IMO MC 24 S 00 1 3 1 3 5 6 4 2 N L2 L1 L3 2 2 18 25 10 24 9 9 10 16 23 24 25 26 ELEMENT POSITIONS ARE WHEN VIEWED FROM FRO...

Page 10: ...17 21 RED NEON 19 23 25 8 10 CONTACTOR IMO MC 24 S 00 1 3 1 3 5 6 4 2 N L2 L1 L3 2 2 18 26 11 24 9 9 24 ELEMENT POSITIONS ARE WHEN VIEWED FROM FRONT OF APPLIANCE H1 OUTSIDE LH ELEMENT 3 65kW 230V H2 I...

Reviews: