background image

1.

    Using a mud ring or a junction box as a guide, mark the holes and cut out the 

  material within the marked area. 

If installing a junction box, allow enough depth for 
the wall plate and cables. 
The box should be at least 2.0” (5.1 cm) deep to 
accommodate the connectors, plate, and cables.

2

.    Either

    • Insert the mud ring into the opening, rotate

 

      the dog legs, and secure with the screws provided, 

    or
   

 Insert the wall box and secure with 10-penny nails

 

      or screws.

3.

    Run the RS-232 and IR signal cables behind the wall

 

  and thread them through the mud ring or wall box.

  N

  Extron recommends using a good quality, low 

capacitance, shielded cable such as an Extron 
CTL or SPL Control cable.

Decora

Faceplate

Extron
WP CTL D 

Wall

Wall Mounting

Bracket

G

S

IR

G
Rx
Tx

Serial

WP CTL D Installation Guide

The Extron WP CTL D is a Decora style 1-gang wall plate which passes RS-232 control signals

 

from a computer or control system, and IR signals from an IR source.

 

Install it directly into the wall using a mud ring, or in a 1-gang junction box (not supplied),

 

following the steps below.

4. 

Connect the IR cable to the rear panel IR 

connector by inserting the signal wire into 

the hole marked "S" , and the ground wire 

into the hole marked "G" (see inset, step 4).

N

 

The recommended driving distance from 

an MLC controller is 100 feet.

5. 

Connect the RS-232 cable to the rear panel RS-232

 

connector by inserting the ground wire into the hole

 

marked "G", the transmit wire into the hole marked  

"Tx", and the receive wire into the hole marked

 

"Rx" (see inset, step 5).

6

.  Mount the device into the mud ring or wall box.

7

.  Attach the supplied Decora faceplate.

N

  If applicable, repeat steps 

1-7

 to install additional wall plates.

8

.    Connect the RS-232 control device and/or IR input device to the front of the WP CTL D.

Extron 

USA - West

 

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517

 

FAX

Extron 

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797

 

FAX

Extron 

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 

FAX

Extron 

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664

 

FAX

Extron 

Japan

+81.3.3511.7655

+81.3.3511.7656

 

FAX

Extron 

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566

 

FAX

Extron 

Dubai

+971.4.2991800

+971.4.2991880

 

FAX

68-1618-01

Rev B 08 08

WP CTL D Installation Guide, cont’d

Step 5

Step 4

G

Tx

Rx

WP CTL D

IR Out

White striped wire

S = Signal (IR)

G = Ground

G S

IR Emitter

100'

(30.5 m)

Reviews: